| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for : or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 4 | Suspended floors, roofs, landings, balconies and access platform. |
| 5 | Edges of slabs and breaks in floors and walls Under 20 cm wide. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 9 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 10 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 11 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 12 | Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete. as per direction of Engineer in Charge and as per MORD specification including carriage of all labour equipment and materials to various location of site through all modes of transportations in all leads lifts and all incidental charges. |
| 13 | Providing and laying vitrified floor tiles (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 14 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 16 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-incharge.Second class teak wood 35 mm thick shutters |
| 17 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood.or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 18 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 20 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : |
| 21 | 125x65x2.12 mm |
| 22 | 75x47x1.70 mm |
| 23 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 24 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 25 | 200x10 mm |
| 26 | 100x10 mm |
| 27 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 28 | 125 mm |
| 29 | 100 mm |
| 30 | Providing and fixing bright finished brass hard drawn hooks and eyes :150 mm or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 31 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 32 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes.or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 34 | 110 mm diameter |
| 35 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 36 | Coupler 110 mm diameter |
| 37 | Bend 87.5° 110 mm bend |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 39 | 110 mm |
| 40 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 41 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. |
| 42 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture or as directed by the Engineer-in-Charge including carriage of materials with in all leads and lifts and other incidental charges. Please Enable Macros to View BoQ information |