| 1 | ( Civil Work)Stripping and stacking slate or tiles of a roof.(2nd floor) |
| 2 | Dismantling concrete Reinforced cement concrete (Existing parapets columns) |
| 3 | Dismantling brick work tile, masonry or tile lining In cement |
| 4 | Re-barring (Chemical Anchor) of 20mm dia bar, hole size 25mm, depth 200mm with 47 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect |
| 5 | Re-barring (Chemical anchor) of 25mm dia bar, hole size 32mm, depth 250mm with 100 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 6 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) (for 2nd floor) |
| 7 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. for 2nd floor |
| 8 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) (for 3rd floor) |
| 9 | extra rate for 3rd floor |
| 10 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 11 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. for 2nd floor |
| 12 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 13 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. for 3rd floor |
| 14 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 15 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. for 2nd floor |
| 16 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 17 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to theroof top level of that storey. for 3rd floor |
| 18 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 19 | Extra Rate for 2nd floor |
| 20 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (for 3rd floor) |
| 21 | Extra Rate for 3rd floor |
| 22 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level |
| 23 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. for 2nd floor |
| 24 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level |
| 25 | Extra Rate for 3rd floor |
| 26 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : (for 2nd floor) |
| 27 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : (2nd floor) |
| 28 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : (for 3rd floor) |
| 29 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and othersections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : (3rd floor) |
| 30 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 31 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 32 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thicknessfor 3rd floor |
| 33 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 |
| 34 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 35 | Extra for work done in each subsequent storey above the first storey |
| 36 | Extra Rate for 3rd floor |
| 37 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 38 | Extra rate for 2nd floor |
| 39 | Extra rate for 3rd floor |
| 40 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps |
| 41 | extra rate for 2nd floor |
| 42 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps |
| 43 | Extra rate for 3rd floor |
| 44 | Plastering on underside of ceiling 10mm thick cement plaster 1:3 (2nd floor) |
| 45 | Plastering on underside of ceiling 10mm thick cement plaster 1:3 (3rd floor) |
| 46 | 20mm thick cement plaster 1:5 in two coat work |
| 47 | 20mm thick cement plaster 1:5 in two coat work for 3rd floor |
| 48 | 12.5 mm thick cement plaster 1:5 (for 2nd floor) |
| 49 | 12.5 mm thick cement plaster 1:5 (for 3rd floor) |
| 50 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 51 | Extra rate for 2nd floor |
| 52 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 53 | Extra rate for 3rd floor |
| 54 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 55 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 56 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing CementPaint applied @ 2.20 Kg/10 Sqm |
| 57 | Terracing consiting of tiles 22.86x11.43x3.83 cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 58 | Extra rate for 3rd floor |
| 59 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 60 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 61 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 2.50 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes. U-PVC pipes (working pressure 2.5 kgf. / sqcm) Single socketed pipe 110 mm dia. |
| 62 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 63 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 64 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 65 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 66 | Electrical WorkSupply & erection of wiring light point 34.02 ii (579.00 + 25% =Rs.723.75 + 5.35 % = Rs.762.47) |
| 67 | Supply & erection of wiring Fan point (with Fan Box ) 34.02 I (b) (919 +25% = Rs.1148.75 + 5.35% = Rs.1210.20) |
| 68 | Wiring 6Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES 34.02 (V) (282.00 + 25% = Rs.352.50 + 5.35% = Rs.371.35) |
| 69 | Supply & erection of wiring 16Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES 34.02 (VI) (363.00 + 25% =Rs.453.75 + 5.35% = Rs.478.02) |
| 70 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 1.5 sq.mm (Un-sheathed) 34.09 ii (18 + 60 % = Rs.28.80 + 5.35% = Rs.30.34) |
| 71 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 4 sq.mm (Un-sheathed) 34.09 iv (39 + 60 % = 62.40 + 5.35% = Rs.65.73) |
| 72 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 34.12 (x) (48.00 + 40% = Rs. 67.20 + 5.35% = Rs.70.79) |
| 73 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 6-32amp. (10kA, Curve-C) CSR 34.16 A (ii) (134 +50 % = Rs.201.00 +5.35% = Rs.211.75 ) |
| 74 | MCB Double Pole 50, 63amp. . (10kA, Curve-C) CSR 34.16 A (viii) (654 +50 % = Rs.981.00 +5.35% = Rs.1033.48 ) |
| 75 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated Copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 8 way each CSR 34.17 (ii) ( 1169 +15 % = Rs.1344.35 +5.35% = Rs.1416.27 ) |
| 76 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminum with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 77 | Supply and erection of Ceiling Fan 1200mm (48\\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High Speed Opel White, Anchor XL code14067 WH, Havell's Velocity HS BFUHS/UWD/2021/25524-30 Dt 20/12/2021 |
| 78 | OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS,CLAMPS, JUMPERS & JOINT KITS:Wiring over-head line in PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia. (14 SWG) with brass/ aluminium link clips complete in all respect as approved and desired by the Engineer In-Charge at site.PVC insulated & PVC sheathed aluminium conductor cable Overall Size 16mm² (1/1.40mm) Twin Core CSR 34.34 (i) d (68+ 50 % = Rs.102+5.35% = Rs. 107.45 ) |
| 79 | SHEET METAL IRON CLAD SWITCHES: Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-ICDP Switch 63amp., 415volts CSR 34.18 (ii) (2008+ 35 % = Rs.2710.80+5.35% = Rs.2855.82 ) Please Enable Macros to View BoQ information |