|
| 1 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 2 | Dismantling brick work tile, masonry or tile lining In cement |
| 3 | Dismantling Reinforced Cement Concrete work |
| 4 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled |
| 5 | Dismantling asbestos cement celotax or other hard board ceiling or partition walls including supporting timber |
| 6 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation |
| 7 | Cement concrete 1:5:10 with 40 mm gauge stone ballast using mechanical mixer |
| 8 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering infoundation and plinth |
| 9 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 10 | Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded |
| 11 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 12 | Extra rate at first floor |
| 13 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 14 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 15 | Centring and shuttering for columns (Square or rectangular or polygonal in plain) |
| 16 | Extra rate at first floor |
| 17 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 18 | Extra rate at first floor |
| 19 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc |
| 20 | Extra rate at first floor |
| 21 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering insuperstructure |
| 22 | Extra rate at first floor |
| 23 | Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete. |
| 24 | Extra for steel work done at first floor |
| 25 | Re-barring ( Chemical Anchor) of 8mm dia bar, hole size 12mm, depth 100mm with 10ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect |
| 26 | Re-barring ( Chemical Anchor) of 10mm dia bar, hole size 14mm, depth 100mm with 10 ml injectable mortar epoxy adhesive (Hybridurethane methacrylate adhesive) re-baring chemical complete in all respect |
| 27 | Re-barring (Chemical Anchor) per hole for 16mm dia bar, hole size 20mm, depth 160mm with injectable mortar epoxy adhesive (Hybridurethane methacrylate adhesive) rebaring chemical 24 ML |
| 28 | Re-barring (Chemical Anchor) of 20mm dia bar, hole size 25mm, depth 200mm with 47 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 29 | Re-barring (Chemical anchor) of 25mm dia bar, hole size 32mm, depth 250mm with 100 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 30 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 |
| 31 | 20 mm thick cement plaster 1:5 on walls |
| 32 | 12.5 mm thick cement plaster 1:4 on walls |
| 33 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 34 | Terracing consiting of tiles 22.86x11.43 x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. |
| 35 | Extra rate for tile terracing at first floor |
| 36 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) |
| 37 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 38 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 39 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling. |
| 40 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 41 | Extra rate for screed at first floor |
| 42 | Udaipur Green Marble tile flooring with 15-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Slabs sizes above 0.50 sqm |
| 43 | Extra rate for marble work at first floor |
| 44 | Providing and fixing of floor mat of construction level loop plain Ployprophlence sholution dye of 5 mm thickness of wieht 3350 gsm with bituman+felt of size 50X50 cm |
| 45 | Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions make approved by Engineer in Charge ,(Glazing and paneling to be paid for separately)Fixed portion |
| 47 | Moveable Portion |
| 48 | Providing polyster powder coating 50 micron any colour specified to aluminium section of various sizes including carriage of material from maket to workshop. |
| 49 | Providing and fixing glazing 5mm thick in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 50 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side |
| 51 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete. ISI designation no I (Size of door up to 700mm) |
| 52 | Providing and fixing commercial plywood 18mm thick |
| 53 | Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra) 6mm thick decorative ply wood teak faced on one side |
| 54 | Spirit polishing two coats including a coat of wood filler on wood work |
| 55 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 56 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade |
| 57 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied@ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 58 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but excluding cost of lead jointing. (Type - B)110mm o/d SWR UPVC pipe line laid complete |
| 59 | 90mm o/d SWR UPVC pipe lines laid complete |
| 60 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipesDoor Elbow 90 Degree (Door Bend) |
| 61 | Elbow 90 Degree (Bend Plan) |
| 62 | Coupler |
| 63 | P Trap/Floor Trap 110mm x 75mm |
| 64 | For 90mm o/d pipes Elbow 90 Degree (Bend Plan) |
| 65 | Coupler |
| 66 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge )110mm o/d |
| 67 | 90mm o/d |
| 68 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 69 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 70 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. |
| 71 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect |
| 72 | Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and ofrequired shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect |
| 73 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects |
| 74 | Cleaning of building Rubbish from site to outside building premises lead 5 kms. |
| 75 | Add Electrical Services (Item as per CSR 2020) |
| 76 | Add Public Health Services (Item as per CSR 2020) Please Enable Macros to View BoQ information |