| 1 | 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 2 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 4 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | 6.3 Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : 6.3.1 With F.P.S.(non modular) bricks |
| 6 | 11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:6 (1cement : 6 coarse sand) |
| 7 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 8 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns etc. for mass concrete |
| 9 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Coulumns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Stairs (excluding landing) except spiral staircase |
| 12 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges |
| 13 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform |
| 14 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 15 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | 13.10 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 17 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 18 | 11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 19 | 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge: Profile B 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb |
| 20 | 9.145 Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing andfixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin- charge. |
| 21 | 9.146 Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles afterinserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge. |
| 22 | 9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering ith vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 23 | 16.88 Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge |
| 24 | 21.20 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 25 | 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.1 Fixed to steel windows by welding |
| 26 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick |
| 27 | 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 28 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 30 | 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash................ specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 31 | 13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :13.43.1 Water thinnable cement primer |
| 32 | 13.50.3 With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/steel works |
| 33 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 34 | 2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 2.28.1 All kinds of soil |
| 35 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 36 | 9.73 Providing and fixing bright finished brass Parliamentary hinges with necessary screws etc. complete. 150x125x27x5mm |
| 37 | 9.74 Providing and fixing bright finished brass tower bolts with necxessary screws etc. complete 250x10mm |
| 38 | 9.62 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete 300x16mm |
| 39 | 9.75 Providing and fixing bright finished brass door latch with necxessary screws etc. complete 300x16x5mm |
| 40 | 9.76 Providing and fixing bright finished brass 100mm mortice latch and lock with 6 levers and apair of lever handles of approved quality with necxessary screws etc. complete |
| 41 | 9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 42 | 9.82 Providing and fixing bright finished brass hanging type floor door stopper with necxessary screws etc. complete |
| 43 | 9.92 Providing and fixing chromium plated brass handles with necxessary screws etc. complete 125 mm |
| 44 | 5.2 Reinforced cement concrete in walls(any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth upto floor five level excluding the ost of centering, shuttering , finishing and reinforcement (1 cement:1.5 coarse sand(zone-III) derived from natural source : 3 graded stone aggregate 20mm nominal size derived from natural sources) |
| 45 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in -charge. 100 mm nomonal dia pipes |
| 46 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in -charge. 80 mm nomonal dia pipes |
| 47 | 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid 10litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid |
| 48 | 17.4.1 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cisteern with fittings, standard size C.P. brass flush pipe, speaders with unions and clamps. Range of three half stall urinals with 10 litres PVC automatic flushing cistern. |
| 49 | 17.6 Providing and fixing one piece construction white vitreous china squating plate with an intregal longitudinal flushing pipe , white PVC automatic flushing cistern, with fittings, standard size G.I./PVC flush pipe for back and front flush with standard speader pipes with fittings, G.I. clamps and C.P. brass coupling complete, including painting of fittings and cutting and make good the walls and floors etc. Range of three squatting plates with 10 litre PVC automatic flushing cistern |
| 50 | 17.7 Providing and fixing wash basin with C.I. brackets, 15mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required Stainless Steel AISI-304(18/8) wash basin 530x345 with single 15mm C.P. brass pillar tap |
| 51 | 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective hright 0f 88mm, weighing not less than 190gms |
| 52 | 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Square shape 450mm internal dimension |
| 53 | 19.33 Construction of soak pit 1.2 x1.2x1.2 m filled with brickbats including S.W. drain pipe 100mm dia and 1.20m long complete as p[er standard design. |
| 54 | 5.3.2 Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost). FIRST TEST BOARING =120.00 RM |
| 55 | Providing water supply facility (PHED) approved . Total = 2 job |
| 56 | Driling with Rig Bit in overburden portion of soil foundation including ........ As directed (Rate as per PHED deptt. approved rate ). Total depth upto rock =120.00 |
| 57 | Lowering of well assembly welding of pipe joints of 200 mm dia G.L./ M.S. Casing pipe as directed. T.D.=120.00 For gap of soil =6.00 total 126.00m (Rate as per PHED deptt. approved rate ). |
| 58 | Driling with rig with usuing the DTH hammer in all classes of rock including collection of sample...etc complete. Total depth= 120.00 (Rate as per PHED deptt. approved rate ). |
| 59 | 5.3.9 Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE SUPREME / PRINCE / FUSION /SFMC Brand ix) 200mm diameter |
| 60 | 5.3.12 Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained |
| 61 | 3.39.69 Supplying including installation of submersable pumpset with all accessories including pannel board on Cc foundation … 5HP |
| 62 | 5.3.6 Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. B) PVC PIPE iv) 50mm diameter |
| 63 | 5.3.11 Supplying fitting and fixing check valve (non return valve) including thread to pipes. vii) 100mm diameter |
| 64 | 3.17.1 Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. a) 50mm dia |
| 65 | 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engeneer-in-charge. Internal work-Exposed on wall 15 mm dia |
| 66 | 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engeneer-in-charge. Internal work-Exposed on wall 20 mm dia |
| 67 | 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engeneer-in-charge.Internal work-Exposed on wall 25mm dia |
| 68 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engeneer-in-charge. External work 32mm dia |
| 69 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engeneer-in-charge. External work 40mm dia |
| 70 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engeneer-in-charge. External work 50mm dia |
| 71 | 18.15 Providing and fixing brass bib cock of approved quality 15mm dia |
| 72 | 18.16 Providing and fixing brass stop cock of approved quality Code No. 7259 C.P. Brass long body bibcock 15mm |
| 73 | 18.18 Providing and fixing ball valve (brass) of approved quality, gigh or low pressure, with plastic floats complete. 20mm dia |
| 74 | 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms |
| 75 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. |
| 76 | 1.1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP A |
| 77 | 1.1.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP B |
| 78 | 1.1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C |
| 79 | 1.3.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP A |
| 80 | 1.5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulatedcopper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 81 | 1.6 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 82 | 1.7.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 83 | 1.7.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 84 | 1.7.4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 85 | 1.7.5 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 86 | 1.7.10 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 87 | 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required GROUP B |
| 88 | 1.55.3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLSPVC insulated copper conductor single core cable etc. as required. GROUP C |
| 89 | 2.1.2 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N |
| 90 | 2.12.2 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63 A |
| 91 | 4.1.3 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness |
| 92 | 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Supplying and laying 6 SWG G.I. wire at 0.50 metre below |
| 93 | 11.2 Erection of RCC/ PCC pole strut in brick ballast and ramming the foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 94 | 19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper inding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 74-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 95 | AN Supplying with installation testing and commissioning of the following capacity with cordless remote complete with indoor and outdoor unit copper pipe and electrical connection as approved by the department up to 5m between the room unit and outdoor unit as directed by the deptt. 1.5 Ton Capacity (Market Prise Rs. 43400.00) |
| 96 | AN Supplying with installation testing and commissioning of the following capacity with cordless remote complete with indoor and outdoor unit copper pipe and electrical connection as approved by the department up to 5m between the room unit and outdoor unit as directed by the deptt. 2 Ton Capacity (Market Prise Rs. 49800.00) |
| 97 | ASEB Connection & Load Security (Rs. 8000/KVA) |
| 98 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 99 | 13.50 Applying priming coat:13.50.1 With ready mixed pink or Grey primer of approved brandand manufacture on wood work (hard and soft wood) |
| 100 | 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work |
| 101 | 13.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 102 | 17.32 Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing :17.32.4 Rectangular shape 1500x450 mm |
| 103 | 17.41 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 17.41.1 100x100x100x100 mm Please Enable Macros to View BoQ information |