| 1 | Construction of Hostel |
| 2 | 1/2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1: All kinds of soil. |
| 3 | 2/11.2 : Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 4 | 3/2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | 4/4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | 5/4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 7 | 6/5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 8 | 7/5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 8/5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | 9/5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | 10/5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | 11/5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 13 | 12/5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.7 Stairs, (excluding landings) except spiral-staircases |
| 14 | 13/6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 15 | 14/6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 16 | 15/11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 17 | 16/11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 18 | 17/13.5 15 mm cement plaster :13.5.1 1:4 (1 cement : 4 coarse sand) |
| 19 | 18/13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 20 | 19/13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 21 | 20/9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 22 | 21/9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :9.96.1 300x16 mm |
| 23 | 22/9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.2 250x10 mm |
| 24 | 23/9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.2 100 mm |
| 25 | 24/5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 26 | 25/9.1.2 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood |
| 27 | 26/10.17 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 28 | 27/9.147D: Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 9.147D.1 Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 29 | 28/11.47 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately).11.47.2 Size of Tile 600x600 mm |
| 30 | 29/8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 31 | SEPTIK TANK Item No 1(2.8) :Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil |
| 32 | Item No 2 (11.2): Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 33 | 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 34 | Item No 4 (5.22) : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 35 | Item No 5 (5.1.2) : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 36 | Item No 7 (5.9.1) : Foundations, footings, bases of columns, etc. for mass concrete |
| 37 | tem No 8 (5.9.5): Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 38 | Item No. 9(5.9.16.2) : Edges of slabs and breaks in floors and walls 5.9.16.2 Above 20 cm wide |
| 39 | Item No 10(6.2): Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 40 | Item No 11(11.5) : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. |
| 41 | tem No 12( 11.6.1 ) : Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 42 | Item No 13( 13.2.1 ) : 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 43 | ELECTRICAL ITEM Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A |
| 44 | Group-B |
| 45 | Group-C |
| 46 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/rcessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 47 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 48 | 3 pin 5/6 A socket outlet |
| 49 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 50 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) |
| 51 | 6 Module (200mmX75mm) |
| 52 | 8 Module (125mmX125mm) |
| 53 | Supplying and fixing following Modular base & cover plate on existing modular metal box as required. 4 Module |
| 54 | 6 Module |
| 55 | 8 Module |
| 56 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess cpmlete with tinned copper bus bar, neutral bus bar, eart bar, din bar, inter connections, powder painted including earthing etc. as required.(but excluding MCB/RCCB/Isolator). 6 way , Double door |
| 57 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 58 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 59 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 60 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. As required. |
| 61 | BEE 5 star rated, ceiling fan with Brush Les Direct Current (BLDC) Motor, Basic Price for 1200 mm sweep BLDC Ceiling fan i/c all accessories/fittings/supports etc. |
| 62 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted icluding earthing etc. as required.6 way (4 + 18), Double door |
| 63 | Supplying and fixing tube/lamp LED 5-watt including connections etc. as required. |
| 64 | Sanitary and Water supply works:-Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standardmake and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :wherever required :17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 65 | 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CPBrass single hole basin mixer |
| 66 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.17.28.2 Flexible pipe17.28.2.1 32 mm dia |
| 67 | Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing :17.32.4 Rectangular shape 1500x450 mm |
| 68 | Providing and fixing toilet paper holder :Providing and fixing toilet paper holder :17.34.1 C.P. Brass |
| 69 | Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 70 | Cutting chases in brick masonry walls for following diameter sandcast iron/centrifugally cast (spun) iron pipes and making good thesame with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6graded stone aggregate 12.5 mm nominal size), including necessaryplaster and pointing in cement mortar 1:4 (1 cement : 4 coarsesand) : |
| 71 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms. |
| 72 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms. |
| 73 | Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour.17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms18.8.4 32 mm nominal dia Pipes |
| 74 | 18.8.4 32 mm nominal dia Pipes |
| 75 | 18.8.4 25 mm nominal dia Pipe |
| 76 | Constructing masonry Chamber 60x60x75 cm inside, in brick workin cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameterand 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mmnominal size ) , i/c necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design :18.33.1 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 77 | Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms.18.51.1 15 mm nominal bore |
| 78 | Providing and fixing PTMT pillar cock of approved quality and colour.18.56.2 15 mm nominal bore, 125 mm long foam flow, weighingnot less than 120 gms |
| 79 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :18.22.1 100 mm diameter: |
| 80 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) :18.17.1A 20 mm nominal bore |
| 81 | Providing and placing in position filters of 40 mm diameter G.I. pipewith brass strainer of approved quality. |
| 82 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.18.10.2 20 mm dia nominal bore |
| 83 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :18.13.1 25 to 40 mm nominal bore |
| 84 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 85 | Providing and fixing required Stainless Steel Fitting of press fit designof grade AISI 304 conforming to JWWA G116 standard with V-profileor M-profile and with O-ring sealing gasket of EPDM material ofrequired dia as per direction of Engineer-in-chargeCoupling/Socket18.87.5 For 42.70 mm outer dia pipe |
| 86 | roviding and fixing required Stainless Steel Fitting of press fit designof grade AISI 304 conforming to JWWA G116 standard with V-profileor M-profile and with O-ring sealing gasket of EPDM material ofproviding and fixing required Stainless Steel Fitting of press fit designof grade AISI 304 conforming to JWWA G116 standard with V-profileor M-profile and with O-ring sealing gasket of EPDM material ofrequired dia as per dirction of Engineer-in-charge.Reducer18.88.6 For 34.00 mm x 28.58 mm outer dia pipe |
| 87 | 18.88.10 For 42.70 mm x 34.00 mm outer dia pipe |
| 88 | 18.88.15 For 48.60 mm x 42.70 mm outer dia pipe |
| 89 | 18.90A Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS : 6911:2017 and conforming to EN-10312 standardswith V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge.Elbow 90°18.90A.4 For 35 mm outer dia pipe |
| 90 | 18.90A.5 For 42 mm outer dia pipe |
| 91 | 18.92A Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS : 6911:2017 and conforming to EN-10312 standardswith V-profile and with O-ring sealing gasket of EPDM material of requireddia as per direction of Engineer-in-charge.Equal Tee18.92A.4 For 35 mm outer dia pipe |
| 92 | 18.93A Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS : 6911:2017 and conforming to EN-10312 standardswith V-profile and with O-ring sealing gasket of EPDM material of requireddia as per direction of Engineer-in-charge.Reducing Tee18.93A.5 For 35 mm x 22 mm outer dia pipe |
| 93 | BORE WELL Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer -in-charge, beyond 90 metre & upto 150 metre depthbelow ground level.23.2.1 All types of soil23.2.1.2 350 mm dia |
| 94 | Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, asper direction of Engineer -in-charge.23.3.2 150 mm nominal size dia |
| 95 | Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs,conforming to IS: 12818, including hire & labour charges, fittings &accessories etc. all complete, for all depths, as per direction ofEngineer-in-charge.23.4.2 150 mm nominal size dia |
| 96 | Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. |
| 97 | Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. |
| 98 | Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 99 | Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. |
| 100 | Supplying, assembling, lowering and fixing in vertical position in borewell, ERW (Electric Resistance Welded) FE 410 plain slotted (havingslot of size 1.6/3.2 mm) mild steel threaded and socketed/ plainbevel ended pipe (type A) of required dia, conforming to IS: 8110, ofreputed and approved make, having wall thickness not less than5.40 mm, including painted with outside surface with two coats ofanticorrosive bitumestic paint of approved brand and manufacture,including hire & labour charges, fittings & accessories, all complete,for all depths, as per direction of Engineer -in-charge.23.11.2 150 mm nominal size dia |
| 101 | evelopment of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well is fullydeveloped, measuring yield of well by \\"V\\" notch method or any otherapproved method, measuring static level & draw down etc. by stepdraw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, includinghire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge. |
| 102 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessarybolts & nuts of required size complete.23.14.2 150 mm clamp |
| 103 | Providing and fixing Bail plug/ Bottom plug of required dia to thebottom of pipe assembly of tubewell as per IS:2800 (part I).23.15.2 150 mm dia |
| 104 | Supplying, fitting and fixing of 5HP Submersible pump of approved brand and manufacturer with all necessary fittings. as per direction of Engineer-in-charge. |
| 105 | BOUNDARI WALL Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 106 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 107 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 108 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 109 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 110 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 111 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 112 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 113 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) |
| 114 | EMENT PLASTER (IN COARSE SAND) 20 mm cement plaster of mix :13.6.1 1:4 (1 cement: 4 coarse sand) |
| 115 | inishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 116 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 117 | IRON GATE Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 118 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 119 | Providing and laying in position cement croncrete of specifed grade excluding cost of centering and shuttering.--All works up to plinth level. |
| 120 | ReinforcementSteel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level5.22A.6:- Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 121 | 8mm dia T.S. |
| 122 | Centering and shuttering including strutting, propping etc. and removal of form for:5.9.6 - Columns, Pillars, Piers, Abutments, Posts and Struts |
| 123 | 5.9.21. : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 124 | 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 125 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 126 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 127 | 20 mm cement plaster of mix :20 mm cement plaster of mix :13.6.2 1:6 (1 cement: 6 coarse sand) |
| 128 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) contentApplying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 129 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : |
| 130 | Supplying fitting and fixing double leaf heavy duty iron gate etc. complete. |
| 131 | 1.5 Fire fighting 1.5.3 With wet riser and sprinkler system |
| 132 | Add 1.25% Civil external service connection Works (items of work must be considerd from current CPWD DSR 2021, where as the same has been directed by the concerned authority) |
| 133 | Add 3.75 % electrical external service connections Works (items of work must be considerd from current CPWD DSR 2018) |
| 134 | Furniture , as direted by the concerned authority (L/S) |
| 135 | Kitchen All utensils as direted by the concerned authority (L/S) |
| 136 | Library all books, as direted by the concerned authority (L/S) |
| 137 | DG set along with shed/Inverter, as direted by the concerned authority(L/S) |
| 138 | solar System, as direted by the concerned authority (L/S) |
| 139 | cCTV system, as direted by the concerned authority (L/S) Please Enable Macros to View BoQ information |