| 1 | Fabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-Shackle etc. of following type of towers:132kV D/C “DA” KRR Design type Tower |
| 2 | i) +6mtr extn. Only |
| 3 | 132kV D/C “DB” KRR Design type Tower |
| 4 | 132kV D/C “DC” KRR Design type Tower |
| 5 | i) +3mtr extn. Only |
| 6 | 132kV D/C “DD” KRR Design type Tower |
| 7 | i) +3mtr extn. Only |
| 8 | Fabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-Shackle etc. of following type of towers:66kV D/C “DA” KRR Design type Tower |
| 9 | i) +3mtr extn. Only |
| 10 | 66kV D/C “DB” KRR Design type Tower |
| 11 | i) +3mtr extn. Only |
| 12 | ii) +6mtr extn. Only |
| 13 | 66kV D/C “DC” KRR Design type Tower |
| 14 | 66kV D/C “DD” KRR Design type Tower |
| 15 | ii) +6mtr extn. Only |
| 16 | 220kV D/C DC R.S Infra Design type tower |
| 17 | ii) +12mtr extn. Only |
| 18 | 220kV D/C R.S Infra Design Gantry |
| 19 | 66kV M/C MA KRR Design type tower |
| 20 | 66kV M/C MD KRR Design type tower |
| 21 | 66kV M/C MD KRR Design type tower with extra cross arm (set of 3) |
| 22 | Design, Vetting, Fabrication, Supply & commissioning including its foundation of following Monopole at Ground (Raft/Pier/Pile) with all parts like cross arms, bolts & nuts, step bolts, U-bolts, D-shackle, Hanger etc. with RL-1, WZ-5, Normal Span length of 300M for ACSR Zebra (0.4 sq”) Conductor.132kV D/C Cable Termination Monopole (0-15D)/DE type _BXA@14 M suitable for termination of 132KV D/C 1600 sqmm Single Core Aluminum Conductor Milliken type XLPE Insulated cable (6+2 configuration) with following provisions:-i) 8 No. x-arms monopole for D/C cable termination arrangement.ii) Provision of Extra-x-arms on monopole for use of 2 no. spare cables.iii) Arrangement shall be made for connecting these 2 no. spare cables to any phase conductor through existing 6 no. LAs. |
| 23 | Supply of Earthing of towersPipe type |
| 24 | Supply of following Tower accessoriesi) Danger Plate |
| 25 | ii) Number Plate |
| 26 | iii) Phase Plate (set of 3) |
| 27 | iv) Circuit Plate (set of 2) |
| 28 | v) Bird Guard (set of 3) |
| 29 | vi) Anti climbing device |
| 30 | Line Material Conductor (0.4 Sq” ACSR Zebra) |
| 31 | *132KV Anti-Fog type Disc Insulator or 132KV Silicon Rubber Polymer Insulator stringsi) 70 kN |
| 32 | ii) 120 kN |
| 33 | *66KV Anti-Fog type Disc Insulator or 66KV Silicon Rubber Polymer Insulator stringsi) 70 kN |
| 34 | ii) 120 kN |
| 35 | Hardware Fittings for 0.4 sq inch ACSR Zebra Conductor i. Single ‘I’ Suspension String |
| 36 | ii.Single Suspension Pilot String |
| 37 | iii.Single Tension String |
| 38 | iv. Double Tension String |
| 39 | 0.4 sq inch ACSR Zebra Conductor Accessoriesi. Mid Span Compression Joint for ACSR Zebra Conductor |
| 40 | ii) Repair sleeves for ACSR Zebra Conductor |
| 41 | iii) Vibration damper for ACSR Zebra Conductor |
| 42 | iv) Connector suitable for connecting of 0.4 sq. inch ACSR conductor of LILO of 66kV D/C Sonta-Jansui at 66kV Nalvi with existing 0.4 sq inch ACSR conductor of existing 66kV D/C Sonta – Jansui line. |
| 43 | BoQ of OPGW & Communication EquipmentsOPGW (48 fiber) (DWSM, G.652D) (equivalent to Earth wire: 7/3.15mm in all respect) which includes Section –Lilo point to 132 KV S/Stn IIHM Gannaur |
| 44 | OPGW (24 fiber) (DWSM, G.652D) (equivalent to Earth wire: 7/3.15mm in all respect) which Includes LILO of one circuit of 66 KV Sonta – Jansui D/C line at 66 KV S/Stn., Nalvi. |
| 45 | Hardware set for above 48 Fiber OPGW fiber optic (equivalent to Earth wire: 7/3.15mm in all respect) cabling including all cable fittings & accessories except joint box. |
| 46 | Hardware set for above 24 Fiber OPGW fiber optic (equivalent to Earth wire: 7/3.15mm in all respect) cabling including all cable fittings & accessories except joint box. |
| 47 | FODP 96 F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each) |
| 48 | FODP 48 F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each) at 66 KV Nalvi. |
| 49 | Joint Box 3-Way (48/24/24 fiber) OPGW to OPGW |
| 50 | Joint Box (24 fiber) OPGW to OPGW |
| 51 | Detailed Survey, Supply, Laying, testing & commissioning of armored Underground Fiber Optic cable (24 Fiber) in PLB HDPE ducts of suitable size & strength alongwith accessories (as per requirement) in above mentioned sections, installation of Joint boxes, interfacing with existing OPGW on through rate basis as per technical specification. |
| 52 | Joint Box (48 fiber) OPGW to UGFO |
| 53 | Fiber optic Approach cable, 48 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories |
| 54 | Fiber optic Approach cable, 24 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories |
| 55 | Joint Box (48 fiber) UGFO to FOAC |
| 56 | Joint Box (24 fiber) OPGW to FOAC |
| 57 | Wideband Communication equipment and spares:Telecom Equipment as required SDH Equipment (STM - 16 MADM upto 5 MSP protected directions):Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. |
| 58 | Optical Interface Cards/SFPS16.1 SFP (the quantities will be decided at the time of detail engineering) |
| 59 | Tributary cardsE1 Interface card ( Min. 32 interfaces per card) |
| 60 | Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) |
| 61 | Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) |
| 62 | Equipment Cabinet with DDF and all installation accessories |
| 63 | VOIP telephone instrument with one common switch (min. 8 port) compatible with SLDC at required substation. |
| 64 | Integration of the Equipment with existing network |
| 65 | Mandatory SparesTelecom Equipment as required SDH Equipment (STM - 16 MADM upto 5 MSP protected directions)Optical Interface Cards/SFPS16.1 SFP (the quantities will be decided at the time of detail engineering) |
| 66 | Tributary cardsE1 Interface card ( Min. 32 interfaces per card) |
| 67 | Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) |
| 68 | Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) |
| 69 | Pre Connectorized Optical Fiber Patch Cords (10 Mtrs.) -Pack of six Patch cords |
| 70 | Supply of 132KV 1600 mm2 Single Core Aluminium Conductor Milliken type XLPE Insulated cable as per technical specification |
| 71 | Detailed survey including GPR (Ground Penetration Radar survey), Supply, Laying, Testing & Commissioning of 132kV XLPE cable, 1600 sqmm Aluminum Milliken Conductor in Flat formation with one spare cable for each circuit (3+1) alongwith loops and riser in flat formation including Civil works complete in all respect, on through rate basis as per technical specification in Open Cut/Directly Buried Method.Note: - All the work for laying of cables till its commissioning shall be carried out under the supervision of the cable manufacturer and a certificate in this regard shall be issued by the concerned TS wing of HVPNL. |
| 72 | Detailed survey including GPR (Ground Penetration Radar survey), Supply, Laying, Testing & Commissioning of 132kV XLPE cable, 1600 sq. mm Aluminum Milliken Conductor in Flat formation with one spare cable for each circuit (3+1) including loops and riser in flat formation including Civil works complete in all respect at road crossing on through rate basis as per technical specification in Trenchless HDD Method, if required. |
| 73 | Supply and Erection/Laying of 200MM HDPE Pipe for above |
| 74 | Indicative quantity of Supply, Erection, Testing & Commissioning of 1x300mm sq. copper conductor PVC insulated, unarmoured, 6.6 kV sheath bonding cable (to be decided as per requirement) |
| 75 | Supply, Erection, Testing & Commissioning of Outdoor End Termination kit for terminatio of cable on Cable Termination Monopole with all accessories as per technical specification suitable for above cable as per bidder standard design |
| 76 | Supply, Erection, Testing & Commissioning of Outdoor End Termination kit for termination of cable on cable support structure at S/stn end with all accessories as per technical specification suitable for above cable as per bidder’s standard design |
| 77 | Supply, Erection, Testing & Commissioning of 120 kV Polymeric Lightning Arrestor on cable termination tower, complete in all respects as per Latest relevant standard and technical specification of HVPNL. |
| 78 | Earthing of 120 kV Polymeric Lightning Arrestor to be installed on cable termination Monopole including its all allied material. |
| 79 | Indicative quantity for Supply, Erection, Testing & Commissioning of Single-phase Link Box with SVL for each cable (to be decided as per requirement) (Approx) |
| 80 | Indicative quantity for Supply, Erection, Testing & Commissioning of Single-phase Link Box without SVL for each cable (to be decided as per requirement) (Approx) |
| 81 | Supply and Erection of Warning Tape |
| 82 | Supply and Installation of Cable Cleats and other miscellaneous material like all terminal connectors, Trefoil clamps, Nuts & bolts etc for mounting of cables at cable termination Lattice towers and at cable termination structures as per technical specification |
| 83 | Complete Earthing material Set for earthing at all cable terminations, cable joints, LAs, equipment structures and S/Stn. end (as per technical specification) |
| 84 | DISMANTLEMENT WORK TO BE INCLUDED IN ERECTION PART OF BOQi) Dismantlement of following design of towers including its transportation: -The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris as per satisfaction of field office along with their transportation & proper stacking at any dedicated store of HVPNL.i. 66kV S/C A Type Tower (HESB Design) |
| 85 | ii) 66kV S/C B Type Tower (HESB Design) |
| 86 | iii) 66kV S/C C Type Tower (HESB Design) |
| 87 | iv) 4 Pole |
| 88 | iv) H Pole |
| 89 | ii) Dismantlement of existing ACSR Wolf conductor complete with H/W fittings and accessories along with their transportation & proper stacking at designated Dedicated Store of HVPNL. (approx.) |
| 90 | iii) Dismantlement of existing Earth wire complete with H/W fittings and their transportation & proper stacking at designated Dedicated Store of HVPNL. (approx.) |
| 91 | Any other item/items left out but required to complete the work |
| 92 | Civil BOQDetailed Survey |
| 93 | Furnishing bore log data |
| 94 | Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.i) 132kV D/C 'DA' type Tower (KRR Design) classified as - Wet |
| 95 | ii) 132kV D/C 'DB' type Tower (KRR Design) classified as - Wet |
| 96 | iii) 132kV D/C 'DC' type Tower (KRR Design) classified as - Wet |
| 97 | iv) 132kV D/C 'DD' type Tower (KRR Design) classified as - Wet |
| 98 | i) 220 kV D/C Gantry (RS Infra Design) |
| 99 | Construction of fencing arrangement around the Cable termination towers/ Monopole /gantries complete in all respect including excavation,back filling of earth, supply of all fencing & construction material i.e. cement, steel, aggregates and water or any other type of material required to complete the job etc. |
| 100 | Construction and installation of RCC route markers as per Drg. No. HCD/TS-1417 complete in all respect including supply of all construction material i.e. cement, steel, aggregates and water or any other type of material required to complete the job etc |
| 101 | Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 66kV D/C 'DA' type Tower (KRR Design) classified as - Wet |
| 102 | ii) 66kV D/C 'DB' type Tower (KRR Design) classified as - Wet |
| 103 | iii) 66kV D/C 'DC' type Tower (KRR Design) classified as - Wet |
| 104 | iv) 66kV D/C 'DD' type Tower (KRR Design) classified as - Wet |
| 105 | v) 66kV M/C 'MA' type Tower (KRR Design) classified as - Wet |
| 106 | vi) 66kV M/C 'MD' type Tower (KRR Design) classified as - Wet |
| 107 | Construction of tower foundations as per HVPNL Drgs & Specifications for above 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.i) 220kV D/C 'DC+12' type Tower (RS Infra Design)classified as - Wet |
| 108 | Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and disposal of extracted mud/water to suitable location as decided by engineer-in-charge irrespective of type of tower including extensions if any. Please Enable Macros to View BoQ information |