| 1 | Taking down old treatment including PCC padding if any, plastering, removing existing bitumen felt treatment including brushing, cleaning top surface of roof slab, brooming etc complete all as specified and directed. |
| 2 | Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound on fair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra lime or cement ) all as specified and directed.(Water proof compound shall be measured and paid separately under relevant item of BOQ.) |
| 3 | Roof treatment :- Water proofing treatment to RCC roof slab including parapet shall be carried as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (Aluminium paint shall be measured and paid separately under relevant item of BOQ (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only. |
| 4 | Preparation of old painted surfaces of concrete or surfaces of any description and applying two coats of aluminium paint over roof surfaces over 10cm grith or width, not otherwise described complete all as specified and directed. |
| 5 | Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets GI framework complete all as specified and directed. |
| 6 | False ceiling grid galvanzed steel tee/ angle (Powder coated ) of grid size 600x600mm comprising of main and secondry tee ( weight not less than 240gm /RM) and wall perimeter angle (weight of section not less than 217gm/RM) all around of walls suspended with 4mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels insert of any type including 4mm thick designer ceiling boards size 595x595mm fixed in position all as specified and directed. |
| 7 | Dismantling of AC corrugated or semi-corrugated sheets in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed. |
| 8 | Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 9 | Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 10 | Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed. |
| 11 | Dismantling timber scantling under 40sqcm in section unframed work as in fillets, rails, posts, rafters, purlins etc , complete all as specified and directed. |
| 12 | Dismantling mild steel work of any description complete all as specified and directed. |
| 13 | Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as specified and as directed. |
| 14 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 15 | Walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified and as directed. |
| 16 | Diito all as per item no 15 above here-in-before but except stone in CM 1:4 complete all as specified and directed. |
| 17 | Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 18 | Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed. |
| 19 | Rendering 15 mm thick cement plaster with cement mortar(1:4) on other than fair faces of brick or stone masonry surfaces using water proofing compound & finishing the surface even and smooth without using extra cement, complete all as specified and as directed.Note : WPC shall be measured and paid seperately under relevant item of schedule |
| 20 | Rendering 10 mm thick cement plaster with cement mortar(1:6) on other than fair faces of brick or on one side of lathing or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 21 | Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified. |
| 23 | GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required complete all as specified and as directed. |
| 24 | Applying 3mm thick wall care putty over newly plastered surfaces of wall in two layers, complete all as specified and directed. |
| 25 | Supply only liquid water proofing compound. |
| 26 | Complete removal of existing treatment of old surfaces of walls complete all as specified and directed. |
| 27 | Preparation of newly plastered and unplastered surfaces of walls and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed. |
| 28 | Preparation of old plastered surfaces on walls and applying two coats of oil bound distemper complete all as specified and directed. |
| 29 | Preparation of new plastered and unplastered surfaces of walls and applying two coats of interior plastic emulsion paint 1st quality (white/tinted) incl priming of surface with alkali resistant primer complete all as specified and directed. |
| 30 | Preparation of old plastered and unplastered surfaces of walls and applying two coats of interior plastic emulsion paint 1st quality (white/tinted) complete all as specified and directed. |
| 31 | Preparation of new plastered and unplastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall complete all as specified and directed. |
| 32 | Preparation of old plastered and unplastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall complete all as specified and directed. |
| 33 | Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed. |
| 34 | Preparation of old decorated surface of ceiling and applying two coats of oil bound distemper complete all as specified and directed. |
| 35 | Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:3 including formwork/scaffolding work upto height 7.00mtr & applying two coats of exterior emulsion weather proof paint (Apex) as reqd over one coat of primer above ground level of bldg complete all as specified and as directed. |
| 36 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as directed. |
| 37 | Reinforced cement concrete (nominal mix) type B1 1:2:4 using (20mm graded crushed stone aggregatge) for Chajjas/kitchen slab complete all as specified and directed. |
| 38 | Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified. |
| 39 | Reinforced cement concrete (nominal mix) Type B-1 1:2:4 (20mm graded crushed stone aggregate) for cooking platform , slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, Deck slabs and in shelves and the like complete all as specified and as directed. |
| 40 | Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed. |
| 41 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed. |
| 42 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 43 | Plain cement concrete type B0 1:2:4 (12.5mm graded aggregate) 25mm thick as in sub base of floors complete all as specified and directed. |
| 44 | Vitrified ceramic tiles light shade 10mm thick (square /rectangular) polished, area of each tile n.exceeding 0.36 sqm laid as in floors etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match in light shade incl 15mm thick screed bed/back coat in cement and sand mortar 1:4 complete all as specified and directed. |
| 45 | Vitrified ceramic tiles light shade 10mm thick (square /rectangular) polished, area of each tile n.exceeding 0.36 sqm laid as in skirting etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match in light shade incl 15mm thick screed bed/back coat in cement and sand mortar 1:4 complete all as specified and directed. |
| 46 | Non skid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces including 15mm thick screed bed/bedding layers in cement and sand mortar 1:4 complete all as specified and directed. |
| 47 | Glazed ceramic coloured tiles 450x300mmx7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 48 | Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like including pointing in white cement (1:2) using marble dust with admixure of pigment to match with shade of granite including 15mm thick screed of CM 1:4 after applying cement slurry@3 kg/sqm of cement per sqm, complete all as specified and directed.(Note : A hole shall be drilled in the Granite after fixing for gas pipe all as directed). |
| 49 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 Sqm and n.exc 4.00 Sqm each complete all as specified and as directed. |
| 50 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed. |
| 51 | Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 01 Nos 25x3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 as in back filling of pressed steel frame, complete all as specified & directed. |
| 52 | Factory made Pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 01 Nos 25x3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 as in back filling of pressed steel frame, complete all as specified & directed. |
| 53 | Solid PVC (Door/almirah/cupboard) frames of size 50 x 47mm (wooden texture) made out of 5mm dia plain colour PVC Sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified and directed. |
| 54 | Factory made solid Panel PVC( door/almirah shutter/cupboard) shutter 30mm thick (style) consisting of frames made out of MS tubes for tip and bottom rails M.S frames shall be covered with heat channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rails, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/slealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side all as specified and directed. |
| 55 | Steel window /ventilator (Box type factory made with single shutter with or without dovetailed bar (glass shutter) of size 79mmx39mm,16 gauge rectangular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid seperately under respective item |
| 56 | Description all as per Item No.55 above, but only fixed glass pane shutter without glazing bars. |
| 57 | Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 58 | Powder coated aluminium anodised door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. |
| 59 | Powder coated anodised aluminium window / ventilator( glazed / gauged skeleton shutter ), (minimum thickness of powder coating 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No. ) suitable handle (1 No.) complete all as specified and as directed. |
| 60 | Door closer hydraulically regulated, aluminium extruded section body designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed. |
| 61 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around opening complete all as specified and directed. |
| 62 | 35mm thick flush shutters, solid core with particle board exterior grade as per IS 2202 of 199 (Part-I) flush door shall be internally lipped as per clause .8.52.2 of SSR Part-I 2009, complete all as specified & as directed. |
| 63 | 35mm thick 2nd class soft wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc devided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed. |
| 64 | 300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked, fixed in repairs complete all as specified and as directed. |
| 65 | Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed. |
| 66 | Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and as directed. |
| 67 | 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked fixed in repairs complete all as specified and as directed. |
| 68 | Aluminium anodised sliding door bolts with hasp and stapple extruded section or cast aluminium alloy with length of bolt as 300 mm including fixing bolts complete all as specified and directed. |
| 69 | Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed. |
| 70 | 4mm thick glazing sheet ordinary quality with glazing and glazing pins in squares not exc 0.5sqm in each pane complete all as specified and directed. |
| 71 | Figured glass pin headed type, 4mm thick, glazing with oil putty in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed. |
| 72 | 5.5 mm thick tinted sheet glass, selected quality and glazing with aluminium beads and rubber packing in square not exceeding 0.5 square metre in each pane fixed in repairs, complete all as specified and as directed. |
| 73 | 5.5 mm thick tinted sheet glass, selected quality and glazing with aluminium beads and rubber packing in square exceeding 0.5 square metre in each pane fixed in repairs, complete all as specified and as directed. |
| 74 | Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 75 | Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,anodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and as directed. |
| 76 | Curtain rail ,20 mm dia Stainless steel ,chromium plated fixed with CP bracket, incl taking down of old curtain rods, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 77 | Curtain rail ,20 mm dia Stainless steel ,chromium plated fixed with CP bracket, incl taking down of old curtain rods, complete all as specified and directed. Please Enable Macros to View BoQ information |