| 1 | Clearance of Site incl platform cutting if any , removing of Debris, Vegetation , bushes and cutting of trees and disposal of rubbish complete job |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres in All kinds of soil : |
| 3 | Providing & Laying of stone soling (duly hand packed) including watering dressing and ramming to achieve desired compaction incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 4 | Providing & laying in position cement concrete of specified grade including curing but excld. the cost of centring and shuttering all work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 6 | Reinforced cement concrete work in Columns, beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo Mechanically treated bars incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 8 | Providing & laying in position cement concrete of specified grade including curing but excld. the cost of centring and shuttering all work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 9 | Providing & laying in position cement concrete of specified grade including curing but excld. the cost of centring and shuttering all work upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 10 | Centring and shuttering of kit ply including propping, strutting & removal of the same in Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. complete job |
| 11 | Centring and shuttering of kit ply including propping, strutting & removal of the same in Suspended floors, roofs, landings, balconies and access platforms. complete job |
| 12 | Centring and shuttering of kit ply including propping, strutting & removal of the same in Edges of slabs and breaks in floors and walls Under 20 cm wide complete job |
| 13 | Centring and shuttering of kit ply including propping, strutting & removal of the same in Lintel, beams, plinth beams, girders, bressumers and cantilevers complete job |
| 14 | Centring and shuttering of kit ply including propping, strutting & removal of the same in Stairs (excluding landings) except spiral staircases complete job |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 16 | Providing & Laying of Nallah muck in layers of 15cm including watering dressing and ramming to achieve desired compaction incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) incl Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length incl cost of hold fast lugs in First Class Imported Wood incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 19 | Providing and fixing of Ist class Imported wood 30mm thick glazed Shutters for doors, window using 4mm thick float glass panes including ISI mark MS pressed Butt hinges bright finished of required size with necessary screws of size and make as directed by Engineer In Charge with necessary screws incl all costs and carriages of all the materials involved upto site of work complete |
| 20 | Providing and fixing 30mm thick panelled or Panelled and glazed Shutters of Ist class Imported wood for doors using panelling of 1st class Imported wood Panels including ISI marked MS pressed Butt hinges bright finished of required size of size and make as directed by Engineer In Charge with necessary screws incl all costs and carriages of all the materials involved upto site of work complete |
| 21 | Providing and fixing 30mm thick wire gauze shutters of Ist class Imported wood using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge incl all costs and carriages of all the materials involved upto site of work complete |
| 22 | Providing and fixing 4mm thick glass panes with putty and glazing clips or wooden fillets in doors, windows, clerestory windows, all complete with incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 23 | P/F Aliminium anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. of reputed make and model as directed and approved by Engineer in charge incl cost of necessary screws nails etc complete in all respects |
| 24 | Tower Bolts (150mm ) |
| 25 | Tower Bolts (100mm ) |
| 26 | Handles (100mm) |
| 27 | Wind Hooks |
| 28 | Ornamental/Fancy brass Handles of required colour and shade 300mm |
| 29 | Ornamental/Fancy Al Drop of required colour and shade 300mm |
| 30 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost and carriage of all materials to site of work, with all leads, lifts, loading, unloading, stacking, haulage, and octori taxes. |
| 31 | 12 mm thick cement plaster in 1:6 mix (1 Cement : 6 Fine Sand) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job Interior Walls |
| 32 | 6 mm thick cement plaster in 1:3 mix (1 Cement : 6 Fine Sand) incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 33 | Providing and applying 2mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. incl all costs and carriages of all the materials involved upto site of work complete |
| 34 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all leads, lifts, costs and carriages upto site of work complete job |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required shade and colour to give smooth finish with two or more coats on new wood and based surfaces including all leads, lifts, costs and carriages upto site of work complete job |
| 36 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturer's specifications Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture incl all costs and carriages |
| 37 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) incl all costs and carriages |
| 38 | P/F of anchor bolts 450mm in length 16mm dia with threads on both ends and Nuts on Both sides embedded in RCC Slab properly as per the approved location on the slab complete job |
| 39 | Structural steel work welded in built up sections, hollow sections etc incl. cutting,hoisting and fixing in position and applying a priming coat of approved steel primer and two or more coats of synthetic enamel paint incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 40 | P/F precoated galvanized Hihg rib iron profile sheets (Size, Shape and pitch of corrugation as approved by Engineer in Charge) 0.5mm (+0.05%) total coated thickness with Zinc coating 120gms per sqm as per IS :277 in 240 mpa steel grade , 5-7 micron epoxy primer on both sides of the sheet and polyester top coat 15-18 micron. Sheet should have protective guard film of 25 micron minimum to avoid scratches during transportation and should be supplied in single length upto 12 metere or as desired by Engineer in Charge. the sheet shall be fixed using self drilling / self tapping screws of size 5.5x5.5mm with EPDM seal complete including ridges/hips/ valleys of high tensile SMP steel of required width as directed with all necessities complete incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 41 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, including fixing accessories such as nuts, bolts, fasteners etc. complete job |
| 42 | Providing and laying vitrified floor tiles (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (600x600mm) including all leads, lifts, costs and carriages upto site of work complete job |
| 43 | Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge with Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 44 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge for Granite Work incl all leads, lifts, loading, unloading, stacking, costs and carriages incl Head load if any upto site of work complete job |
| 45 | Lighting Points :- One Lighting point shall incl. Wiring for lighting points in 1.5Sq mm PVC insulated Copper wire & 2.5Sq mm PVC insulated multi-strand Copper wire for lighting Sub –mains, 6 Amp one way switch , 2mm thick PVC conduit/ Channel with bends , Junction boxes etc, 6Amp S pole MCB,10 Amp DP MCB , 2 way DB for Housing MCB and Hylem Sheet with wooden box recessed in walls with accessories. |
| 46 | Heating points :- One Heating point shall incl. Wiring for heating points in 2.5Sq mm PVC insulated Multi-Strand Copper wire & 4 Sq mm PVC insulated multi-strand Copper wire for heating Submains, 16 Amp switch socked combined , 2mm thick PVC conduit/ Channel with bends , Junction boxes etc, 10Amp S pole MCB, 2 way DB forHousing MCB and Hylem Sheet with wooden box recessed in walls with accessories |
| 47 | Fan Point: One Fan Point shall incl. Wiring for fan points in 1.5Sq mm PVC insulated multi-strand Copper wire for 1200mm ceiling/225mm Exhaust fan with ceiling roses and PVC square block 350W electronic fan dimmer 2mm thick PVC conduit/Channel with bends , Junction boxes etc, 6Amp S pole MCB,10 Amp DP MCB , 2 way DB for Housing MCB and Hylem Sheet with wooden box recessed in walls with accessories. Please Enable Macros to View BoQ information |