| 1 | DSR item no.40.6Supplying Installation Testing and Commissioning of 5/6 MP IP IR Bullet Camera having following specifications and features etc as per complete item No.1 of DNIT. |
| 2 | 5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera. |
| 3 | DSR item no.40.9Supplying Installation Testing and Commissioning of PTZ (Pan, Tilt and Zoom) IP IR Camera having following specifications and features etc :- PTZ (Pan, Tilt and Zoom) IP IR Camera having following specifications and features etc as per complete item no.2 of DNIT. |
| 4 | 2 MP IP IR motorized PTZ 25/30fps or better) camera, Triple streaming, configurable on resolution Main stream: 1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better,varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digitalzoom with angle of view 57˚–2.4˚, PAN Travel: Pan: 0° ~ 360°endless, Manual Pan: 260° /s, Preset : 300° /s, Tilt, Travel: Tilt:-20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s |
| 5 | DSR item no.40.11Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licensesto record for all channels having specifications and features etc as mentioned below as per complete item no.3 of DNIT. |
| 6 | 32 Channel Network Video Recorder (NVR) having display split: - Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 7 | DSR item no.40.12 Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 8 | 8TB (Terabytes) (4SATA for 32 channel) each NVR |
| 9 | DSR item no.39.3 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 4 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9KJumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC CE marked UL/EN RoHs and relevant MTCTE (TEC)/ BIS compliance/ certification as applicable et. completion required |
| 10 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 11 | DSR item no.39.23Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 12 | 6U Rack |
| 13 | 15 U Rack |
| 14 | DSR Item No.39.18Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy in dentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc.complete as required. |
| 15 | 1 Run of cable |
| 16 | DSR Item No. 1.20Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 25 mm |
| 18 | DSR item no.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 19 | 3 x 1.5 sq. mm |
| 20 | DSR item no.42.4LED displaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc.as required. |
| 21 | 55 inch or larger |
| 22 | DSR item no.26.1Online UPS - Input supply: Single Phase, Output Supply: Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60 db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc |
| 23 | 3 KVA |
| 24 | DSR item no.39.11Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 25 | DSR item no.39.12Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 26 | Copper Patch Cords of length 1m (3ft) |
| 27 | Supply installation Testing and Commissioning of Client Viewing system with i7 gen 10 or better, 2.4 Ghz, 16 GB RAM, 512 GB Storage, 10/100/1000 Gbps NIC, 2 GB Graphic card. Remote Client offers seamless remote access to your CCTV NVR system, enabling live monitoring, playback, and management from anywhere. Designed for reliability and ease of use, it supports multi-platform deployment, OS Compatibility: Windows 10/11 (64-bit), Live view up to 32 channels with H.265/H.264 decoding. Playback/search with timeline, event-based filters, and smart motion replay. Push notifications for motion, tamper, and line-crossing alarms. PTZ control, two-way audio, and electronic map integration. Multi-user access with role-based permissions (Admin, Operator, Viewer). Bandwidth-optimized with adaptive bitrate (64Kbps–16Mbps per channel). The work station should be of HP/Dell/Lenovo/Acer make only and the OEM of client viewing software and camera should be same make or compatible. |
| 28 | AMC under guarantee period 1 year from date of completion/ Handing over the surveillance system |
| 29 | AMC for 2nd year after completion of 1 year free mtc. under warranty period |
| 30 | AMC for 3rd year after completion of 1 year free mtc. under warranty period |
| 31 | AMC for 4th year after completion of 1 year free mtc. under warranty period |
| 32 | AMC for 5th year after completion of 1 year free mtc. under warranty period Please Enable Macros to View BoQ information |