Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | DEVELOPMENT OF NRO Khejurhati P&M |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widt h as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place a nd lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 3 | EXC. OVER AREAS IN ALL KINDS OF SOIL |
| 4 | EXC. OVER AREAS IN ORDINARY ROCK |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1. 5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excav ated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. |
| 6 | EXC. IN ALL KINDS OF SOIL |
| 7 | EXC. IN ORDINARY ROCK |
| 8 | EXC.EXTRA LIFT EVERY 1.5M ALL KIND SOIL |
| 9 | EXC. - EXTRA LIFT EVERY 1.5M HARD ROCK |
| 10 | FILLING AVAILABLE EARTH |
| 11 | SUPPLY AND FILLING IMPORTED EARTH |
| 12 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of a ttached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming inc luding watering, consolidating and dressing complete. |
| 13 | SUPPLY FILLING LOCAL SAND ZONE IV |
| 14 | 1 CEMENT:2 COARSE SAND:4 AGG. 20MM |
| 15 | 1 CEMENT:3 COARSE SAND:6 AGG. 20MM |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 17 | CENT.& SHUT.FOR PCC-FOUND,FOOTING ETC |
| 18 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 19 | RCC 1:1½:3 UP TO PLINTH LEVEL W/O C&S |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 21 | CENT.& SHUTT. FOR RCC FOUNDN,FOOTING |
| 22 | CENT.& SHUTT. FOR RCC COLUMNS |
| 23 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 24 | TMT BARS FE- 500 GRADE |
| 25 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 26 | BRICK WORK IN CM 1:6 IN FOUNDN & PLINTH |
| 27 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 28 | POLISHED GRANITE - KITCH.CUNTR<0.50SM |
| 29 | POLISHED GRANITE - KITCH.CUNTR>0.50SM |
| 30 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. |
| 31 | EXTRA FOR EDGE MOULDING TO GRANITE WORK |
| 32 | EXTRA FOR OPENING FOR WASH BASIN ETC. |
| 33 | STRUCTURAL STEEL WORK IN SINGLE SECTION |
| 34 | STR.STEEL IN BUILT UP SECTION |
| 35 | Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in posi tion and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. |
| 36 | HOT FINISHED WELDED TYPE TUBULAR TRUSS |
| 37 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 38 | 12MM CEMENT PLASTER,1:4 WITH FINE SAND |
| 39 | ACRYLIC SMOOTH EXTERIOR PAINT |
| 40 | DELUXE MULTISURFACE PAINT-STEEL SURFACE |
| 41 | Providing and fixing B class G.I. pipes complete with G.I. fittings including trenching and refilling etc for WATER and AIR, Externa l work |
| 42 | 15 MM DIA. NOMINAL BORE |
| 43 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 44 | 15MM BRASS BALL VALVES-PLASTIC FLOAT |
| 45 | S/L OF 50 MM DIA SINGLE WALL FLEXIBLE PI |
| 46 | S/L OF 80 MM DIA SINGLE WALL FLEXIBLE PI |
| 47 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Sta ndards and as approved by Engineer-in-charge : |
| 48 | FOUND.BOLT 16MMDIAX400MM L,75X5MM PLATE |
| 49 | FOUND.BOLT 25MMDIAX1.0M L,100X8MM PLATE |
| 50 | Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gaske t for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever menti oned shall be of grade M20 |
| 51 | 20KL TANK IN EARTHPIT WITH RCC STRIPRAFT |
| 52 | S/L U/G MS THREADED 40 MM DIA PIPE |
| 53 | S/L A/G MS THREADED 40 MM DIA PIPE |
| 54 | S/L U/G MS WELDED 80 MM DIA PIPE |
| 55 | S/L U/G MS WELDED 50 MM DIA PIPE |
| 56 | Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld ins ide the flanges as per specifications and standard Drg.enclosed herein |
| 57 | S/W SLIPON FLANGES OF 80 MM DIA. |
| 58 | S/W SLIPON FLANGES OF 50 MM DIA. |
| 59 | Making flanged joints between flanges slip on, blind and flange etc. including providing/supplying 3 mm thick permanite oil gasket, nuts, bolts, bonding with 3 mm dia copper wire etc.complete as per IOCL specifications. |
| 60 | MAKING SLIPON / BLIND FLANGE JOINT 80MM |
| 61 | MAKING SLIPON / BLIND FLANGE JOINT 50MM |
| 62 | Supplying and installation of the following threaded |
| 63 | 80 MM DIA AL. CAMLOCK COUPLING - MALE |
| 64 | Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wi re mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. |
| 65 | S/I U TYPE 40MM CS BEND ON VENT PIPES |
| 66 | Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve |
| 67 | S/I SCREWED GM BALL VALVE 50MM DIA |
| 68 | INSTALLATION OF SD/HD DISPENSING PUMPS (MONO /DUAL) Installation of supplied standard duty/heavy duty dispensing pump on existing pu mp island as per IOCL's drawings and instructions including supplying /filling required quantity of dry sand in the pit(s) below th e pump |
| 69 | INST.OF DU WITH ANCHOR BOLT & CC FOUND. |
| 70 | Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, includi ng supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump |
| 71 | 2 PRODUCT - 4 NOZZLE MPP/MPD |
| 72 | Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pre ssure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard a ccessories, including civil works: |
| 73 | S/I OF 5 HP (160-220 LITRES) COMPRESSOR |
| 74 | S/I DIGITAL TYRE INFLATOR |
| 75 | Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a s uitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) |
| 76 | TRANSPTN OF 15/20 KL TANK : 0 - 30 KM |
| 77 | TPT/KM OF 15/20KL TANK: EXTRA > 30KM |
| 78 | T-MONO/DUO/AIRCOMP/STP/PUMPS:3-6, <30KM |
| 79 | T/KM-MONO/DUO/AIRCOMP/STP/PUMPS:3-6, >30 |
| 80 | TPT - MPD/MPP:1-2, <30KM |
| 81 | TPT/KM - MPD/MPP:1-2, >30KM |
| 82 | S & F FRESH WATER IN U/G TANK |
| 83 | REMOVING WATER FROM U/G TANK |
| 84 | Re-installing the dispensing pump on existing foundation including connecting pipelines, electrical connections, tightening nuts of the foundation bolts etc. complete. |
| 85 | RE-INSTALLING MPD / MPP UNIT |
| 86 | S/F 2\\" PV VALVES |
| 87 | ALTERATION TO MANHOLE COVER FOR STP |
| 88 | INSTALLATION OF STP |
| 89 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipe s, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 90 | S&L 3X2.5 SQMM,1.1KV FRLS CU ARMD CABLE |
| 91 | S&L 4X2.5 SQMM,1.1KV FRLS CU ARMD CABLE |
| 92 | SUPPLY AND LAYING OF FLAT CABLES |
| 93 | S&L 3X4SQMM CU FLAT CABLE -SUBM PUMP |
| 94 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade ar moured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 95 | CABLE TERM,NON FLP DC GLAND 3X2.5SQMM |
| 96 | CABLE TERM,NON FLP DC GLAND 4X2.5SQMM |
| 97 | CABLE JOINTING Cable Jointing : Providing straight through joint of following 1.1 KV grade XLPE insulated armoured cable with M-Seal make jointing kit, and other jointing material, etc. all complete including supply of all materials as per specification & directio n of Engineer In-charge. |
| 98 | CABLE JOINTING KIT FOR 3X2.5SQMM |
| 99 | CABLE JOINTING KIT FOR 4X2.5SQMM |
| 100 | CABLE ROUTE MARKER WITH 100X100X5MM |
| 101 | S&F OF FLP JUNC. BOX (4 WAY ENTRY) |
| 102 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and light ning protection under or aboveground complete as per specification for the following : |
| 103 | EARTHING WITH 50 X 10MM G.I. STRIP |
| 104 | EARTHING WITH 32 X 6 MM G.I.STRIP |
| 105 | EARTHING WITH 50 X 6 MM G.I. STRIP |
| 106 | EARTHING WITH 25 X 3 MM GI STRIP |
| 107 | 16SQMM CUCABLE INCL.CROCDILCLIPIN LT PNL |
| 108 | Supply of chemical earthing technology (pipe in pipe) for Electrode Design of specified Current Carrying Capacity in kA for 1 second . Crystaline Conductive mixture which is machine pressed in the pipes should not disintegrade or collapse when the outer pipe corrod es. Resistivity of the Material shall be less than 0.2ohm meter when tested by making a 20cm Cube of the Material & checking the res istance across the opposite faces of the cube. Necessary Test certificate shall be submitted. Concentric Earth Electrode Pipe should be MS of IS:1239 quality & hot Dip galvanised of 150 micron. Electrode Material Selection should be as per Clause 9.3: IS-3043. |
| 109 | CHEM EARTHING - PIPE IN PIPE 15KA |
| 110 | Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc |
| 111 | S&F RUBBER MAT 33KV GRADE (2MX1M SIZE) |
| 112 | S&F 6MM THICK CHEQUERED PLATE |
| 113 | S&F SHOCK TREATMENT CHART |
| 114 | S&F 11 KV GRADE HAND GLOVES, ISI MARK |
| 115 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor us e having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both in comers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, over load and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equip ment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All t he metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provide d with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neopren e type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos eart h terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be pr epared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
| 116 | PANEL & DISTRIB. BOARDS - MEDIUM RO |
| 117 | Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. |
| 118 | S&F MCB+ELCB UPTO 32A DP MCB |
| 119 | Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs |
| 120 | S&F MCB DB WITH 4 WAY (4+12) TPN |
| 121 | S & I OF FLP ESD PUSH BUTTON |
| 122 | Supplying and fixing 12 volt Charged LA battery of approved make for Electronic dispensing pumps including giving necessery electric al connection for the following AH ratings. |
| 123 | 12V , 7AH CHARGED LA BATTERY WITH STAND |
| 124 | CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transfo rmer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and havi ng automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA r atings. |
| 125 | S/I SINGLE PAHSE AIRCOOLED 500VA CVT |
| 126 | SINGLE SERVO VOLTAGE STABILISER Supply and fixing of 230V, Single phase, AC Servo voltage stabilizer of approved makes,(Range - 180 - 250 minimum) shall be provided for Individual dispensing pump as per IE Regulation and as per specification |
| 127 | S/I SINGLE PHASE SERVO STABILISER-5 KVA |
| 128 | THREE PHASE SERVO STABILIZER Supplying and fixing of 3 phase air cooled servo stabilizer for balanced and unbalanced load shall be i ndependent correction of each phase (Range 300 - 460 V minimum) and as per specification |
| 129 | 3PHASE,30 KVA AIRCOOLED SERVO STABILISER |
| 130 | Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. |
| 131 | S&E ARM \\" Y BRACKET 38/50MM DIA. ON POLE |
| 132 | Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole ba se (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-cha rge. |
| 133 | S&D 3CX2.5SQMM PVC CU WIRE IN L POLE |
| 134 | OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : |
| 135 | S&E 7M HIGH GALVANISED OCTAGONAL POLE |
| 136 | YARD LIGHTS: 100W WITH IP66 PROTECTION |
| 137 | PANEL BOARD STICKERING WORK |
| 138 | PANEL BOARD MARKING |
| 139 | PREPARATION OF SLD - ELECTRICAL LAYOUT |
| 140 | PREPARATION OF SLD - EARTHING LAYOUT |
| 141 | Supply and Installation of 16 SWG MS/GI powder coated weather proof Earthing Box of following size with door and locking arrangement with lock and key. Box to be mounted on ISA 40x40x5 (Painted with black synthetic enamel paint) frame having 2 legs of length 800 m m (500 mm above ground and 300 mm below ground which is to be grouted with PCC 1:2:4). Bottom of box should have opening for incomin g earth GI strips all complete, as per specification and direction of Engineer-in-charge. Note: EARTHING BOX in RED should be boldly written over the box. The box should have a hood at the top extending outwards such that no water should seep through inside the bo x during rainy season to avoid rusting. |
| 142 | i) 450 X 300 X 250 mm |
| 143 | DEVELOPMENT OF NRO Khejurhati Non-P&M |
| 144 | SURFACE EXCAVATION |
| 145 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widt h as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place a nd lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 146 | EXC. OVER AREAS IN ALL KINDS OF SOIL |
| 147 | EXC. OVER AREAS IN ORDINARY ROCK |
| 148 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1. 5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excav ated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. |
| 149 | EXC. IN ALL KINDS OF SOIL |
| 150 | EXC. IN ORDINARY ROCK |
| 151 | EXC.EXTRA LIFT EVERY 1.5M ALL KIND SOIL |
| 152 | EXC. - EXTRA LIFT EVERY 1.5M HARD ROCK |
| 153 | FILLING AVAILABLE EARTH |
| 154 | SUPPLY AND FILLING IMPORTED EARTH |
| 155 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of a ttached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming inc luding watering, consolidating and dressing complete. |
| 156 | SUPPLY FILLING LOCAL SAND ZONE IV |
| 157 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 158 | 1 CEMENT:2 COARSE SAND:4 AGG. 20MM |
| 159 | 1 CEMENT:3 COARSE SAND:6 AGG. 20MM |
| 160 | 1 CEMENT:4 COARSE SAND:8 AGG. 40MM |
| 161 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 162 | CENT.& SHUT.FOR PCC-FOUND,FOOTING ETC |
| 163 | PRE-CAST CC 1:2:4 KERB STONE,..WITH C&S |
| 164 | 40MM DAMP PROOF COURSE |
| 165 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 166 | RCC 1:1½:3 UP TO PLINTH LEVEL W/O C&S |
| 167 | Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth an d string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excludin g cost of centering, shuttering, finishing and reinforcement : |
| 168 | RCC 1:1½:3 WALLS ..UPTO 5 LVL W/O C&S |
| 169 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 170 | CENT.& SHUTT. FOR RCC FOUNDN,FOOTING |
| 171 | CENT.& SHUTT. FOR RCC WALLS ETC. |
| 172 | CENT.& SHUTT. FOR RCC SLABS, ROOFS |
| 173 | CENT.& SHUTT. FOR RCCLINTELS, BEAMS |
| 174 | CENT.& SHUTT. FOR RCC COLUMNS |
| 175 | CENT.& SHUTT. FOR RCC FINS |
| 176 | CENT.& SHUTT. WITH PLY FOR RCC BEAMS |
| 177 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 178 | TMT BARS FE- 500 GRADE |
| 179 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per ap proved design mix manufactured in fully automatic batching plant & transported to site of work in transit mixer for all leads havin g continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing & reinforcement including co st of admixtures in recommended proportions as per IS:9109 to accelerate/ retard setting of concrete, improve workability without im pairing strength & durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/cum . Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable. |
| 180 | M25 GRADE RMC UPTO PLINTH LEVEL |
| 181 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 182 | BRICK WORK IN CM 1:6 IN FOUNDN & PLINTH |
| 183 | BRICKWORK IN CM 1:6 IN S/STR UPTO LVL V |
| 184 | HALFBRICK MAS IN CM1:4 S/STR UPTO LVL V |
| 185 | DRY BRICK ON EDGE FLOOR IN MUD MORTAR |
| 186 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 187 | POLISHED GRANITE - KITCH.CUNTR<0.50SM |
| 188 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. |
| 189 | EXTRA FOR EDGE MOULDING TO GRANITE WORK |
| 190 | EXTRA FOR OPENING FOR WASH BASIN ETC. |
| 191 | MS GRILLS TO WINDOWS |
| 192 | CHROME PLATED FLOOR DOOR STOPPER |
| 193 | AL. HYDRAULIC DOOR CLOSER |
| 194 | 100X72MM CHROME PLATED MORTISE LOCK |
| 195 | FACTORY MADE PVC DOOR FRAME |
| 196 | Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on t he hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 1 7mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the he lp of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and dir ection of Engineer-in-charge |
| 197 | FACTORY MADE NON DECO. PVC SHUTTERS |
| 198 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or w ith fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with w ith required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanical ly wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws includin g fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 199 | POWDER COATED AL.SECN,FIXED GLAZING |
| 200 | POWDER COATED AL.SECN, SHUTTERS |
| 201 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass/stainless steel screws etc. complete as per directions of Engineer in charge |
| 202 | PRE-LAM BOTH SIDE DECO.BOARD IN AL.SEC. |
| 203 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket e tc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be pa id in basic item): |
| 204 | FLOAT GLASS 6.0MM IN AL.SEC. |
| 205 | FLOAT GLASS 8.0MM IN AL.SEC. |
| 206 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in f loors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single pie ce M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 207 | DBL ACTION FL.SPRING- BRASS COVER PLATE |
| 208 | FILLING GAP BY SILICON SEALANT |
| 209 | 100MM BRASS LOCKS OF APPD.MAKE |
| 210 | Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in- c harge |
| 211 | POWDER COATED AL.ROUND SHAPE HANDLE |
| 212 | P/FIXING 12MM FRAMELESS TOUGHENED GLASS |
| 213 | STRUCTURAL STEEL WORK IN SINGLE SECTION |
| 214 | STR.STEEL IN BUILT UP SECTION |
| 215 | ROLLING SHUTTERS |
| 216 | Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in posi tion and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. |
| 217 | HOT FINISHED WELDED TYPE TUBULAR TRUSS |
| 218 | MS 16MM DIA FAN CLAMPS |
| 219 | MS GRATINGS,FRAMES,LADDER ETC. |
| 220 | CHEQUERRED PRECAST CC TILES IN FOOTPATH |
| 221 | 25MM KOTA STONE FLOORING |
| 222 | 25MM KOTA STONE IN STEPS |
| 223 | CERAMIC GLAZED TILES FOR WALLS |
| 224 | CERAMIC GLAZED TILES FOR FLOORING |
| 225 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% a nd conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sa nd jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified |
| 226 | 60X60 CM VITRIFIED FLOOR TILES |
| 227 | 60X60 CM VITRIFIED TILES FOR SKIRTING |
| 228 | Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge ) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Micr ons (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. To tal Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scra tches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 229 | KLIPPON GALVALUME PLAIN SHEET RIDGES |
| 230 | KLIPPON GALVALUME PLAIN SHEET FLASHING |
| 231 | KLIPPON GALVALUME SHEET GUTTER |
| 232 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with sea l ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 233 | 110MM PVC RAIN WATER PIPE |
| 234 | 160MM PVC RAIN WATER PIPE |
| 235 | Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes confo rming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. |
| 236 | 110MM UPVC COUPLER |
| 237 | 110MM UPVC SINGLE PUSHFIT COUPLER |
| 238 | UPVC SINGLE T WITH DOOR 110X110X110MM |
| 239 | UPVC SINGLE T WITHOUT DOOR - 110MM.. |
| 240 | UPVC 87.5 DEGREE BEND OF 110MM |
| 241 | UPVC PLAIN SHOE OF 110MM |
| 242 | Providing & fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm h ard wood plugs, screwed with M.S. screws of required length including cutting brick work & fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 243 | 110 MM UPVC PIPE CLIPS |
| 244 | 150F/200F FALSE CEILING |
| 245 | PROVIDING & FIXING BARE KLIPPON GALVALUM |
| 246 | S & F 18 GAUGE GI PLAIN SHEET |
| 247 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 248 | 12MM CEMENT PLASTER,1:6 WITH FINE SAND |
| 249 | 20MM CEMENT PLASTER,1:6 WITH FINE SAND |
| 250 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. |
| 251 | 6MM CEMENT PLASTER WITH FINE SAND |
| 252 | NEAT CEMENT PUNNING |
| 253 | 2MM THK POP PUNNING OVER PLASTER |
| 254 | ACRYLIC SMOOTH EXTERIOR PAINT |
| 255 | DELUXE MULTI SURFACE PAINT SYSTEM |
| 256 | DELUXE MULTI SURFACE PAINT -WOOD WORK |
| 257 | DELUXE MULTISURFACE PAINT-STEEL SURFACE |
| 258 | SYNTHETIC ENAMEL PAINT |
| 259 | Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable pla ce as per direction of Engineer-in-charge. |
| 260 | DEMOLISHING CC 1:3:6 |
| 261 | DEMOLISHING BRICK WORK |
| 262 | DEMOLISHING STONE MASONRY |
| 263 | DISMANTLNG STEELWORK IN BUILTUP SECTION |
| 264 | Dismantling manually/by mechanical means including stacking of serviceable material & disposal of unserviceable material outside si te at unobjectionable place as per direction of Engineer-in-charge : |
| 265 | DISMANTLING WBM ROAD |
| 266 | DISMANTLING BITUMENOUS ROAD |
| 267 | DEMOL.CC/RCC WORK LEAD OF 1000M |
| 268 | Carriage charge for disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, stacking, unloading to approved municipal dumping ground/unobjectionable place as/direction of Eng g- in-Charge beyond IOCL Premises for all leads and including all lifts |
| 269 | MALBA & WASTE CARRIAGE > 1 km < 3 km |
| 270 | MALBA & WASTE CARRIAGE > 3 km < 5 km |
| 271 | PREPARATION OF SUB GRADE |
| 272 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plan t at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform laye rs of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired dens ity, complete as per specification & direction of Engineer-in-charge. |
| 273 | GRANULAR SUB BASE -75MM TO 0.75MM |
| 274 | WET MIX MACADAM |
| 275 | Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufactur ers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658 , maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thorough ly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joi nts at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) |
| 276 | P/L REFLECTIVE LAQUERED M40 80MM THK PAV |
| 277 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x41 0x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 278 | 1 URINAL - 5 L WHITE PVC AUTO-CISTERN |
| 279 | 100MM SCI GULLY TRAP |
| 280 | 600X450 BEVELLED EDGE MIRROR |
| 281 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including a ll CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & f ittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Expo sed on wall |
| 282 | CPVC PIPES 40MM INTRNAL EXPOSED ON WALL |
| 283 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including al l CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fitting s with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. |
| 284 | CPVC PIPES 15MM CONCEALED |
| 285 | CPVC PIPES 20MM CONCEALED |
| 286 | CPVC PIPES 25MM CONCEALED |
| 287 | CPVC PIPES 32MM CONCEALED |
| 288 | Providing and fixing brass bib cock of approved quality : |
| 289 | 15MM BRASS BIB COCK |
| 290 | 20MM BRASS BIB COCK |
| 291 | Providing and fixing brass stop cock of approved quality : |
| 292 | 15MM BRASS STOP COCK |
| 293 | 20MM BRASS STOP COCK |
| 294 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 295 | 25MM GUN METAL VALVE WITH CI WHEEL |
| 296 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 297 | 150MM DIA CP BRASS SHOWER ROSE |
| 298 | PROVIDING POLYETHYLENE TANK ON TERRACE |
| 299 | 15MM CP BRASS LONG BODY BIB COCK |
| 300 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C. I.cover with frame of 300 x300 mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 301 | 100X100MM GULLY TRAP WITH COMMON BRICKS |
| 302 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in th e proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty |
| 303 | 150MM DIA NP2 CLASS RCC PIPES |
| 304 | SOAK PIT 2.5M DIA X 3M DEPTH |
| 305 | ATACTIC PP 5 LAY W.PROF TREAT-GLAS FIB. |
| 306 | WATER PROOFING WITH BRICK BAT COBA |
| 307 | Writing name of Retail Outlet and location/ Indian Oil Corporation monogram, other sign / slogans on building / glass of show windo w etc. of the following heights / diameters with vinyl sticker of approved quality and shade. 150 micron thick Non Reflective Vinyl sticker 3M or Equivalent Brand |
| 308 | LETTER SIZE UPTO 5CM |
| 309 | LETTER SIZE 6-15CM |
| 310 | LETTER SIZE 16-25CM |
| 311 | LETTER SIZE 26-70CM |
| 312 | FOUND.BOLT 25MMDIAX1.0M L,100X8MM PLATE |
| 313 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipe s, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 314 | S&L 3X2.5 SQMM,1.1KV FRLS CU ARMD CABLE |
| 315 | S&L 4X2.5 SQMM,1.1KV FRLS CU ARMD CABLE |
| 316 | S&L 4X16 SQMM,1.1KV ALUMINIUM CABLE FRLS |
| 317 | S&L3.5X35 SQMM,1.1KV ALUMNM CABLE FRLS |
| 318 | S&L3.5X50 SQMM,1.1KV ALUMNM CABLE FRLS |
| 319 | S&L3.5X70 SQMM,1.1KV ALUMNM CABLE FRLS |
| 320 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade ar moured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 321 | CABLE TERM,NON FLP DC GLAND 3X2.5SQMM |
| 322 | CABLE TERM,NON FLP DC GLAND 4X2.5SQMM |
| 323 | CABLE TERM,NON FLP DC GLAND 4X16SQMM |
| 324 | CABLE TERM,NON FLP DC GLAND 3.5X35SQMM |
| 325 | CABLE TERM,NON FLP DC GLAND 3.5X70SQMM |
| 326 | CABLE BRICK DUCT Providing & constructing underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, comple te with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils |
| 327 | U/G 225MM WIDE BRICK DUCT FOR CABLE |
| 328 | 50MM, CLASS B GI PIPE FOR CABLES |
| 329 | Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers , tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams o r any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil |
| 330 | PERFTD GI CABLE TRAY 150MM X 50MM X 2MM |
| 331 | S&F OF FLP JUNC. BOX (4 WAY ENTRY) |
| 332 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and light ning protection under or aboveground complete as per specification for the following : |
| 333 | EARTHING WITH 25 X 3 MM GI STRIP |
| 334 | PROVIDING INTERNAL WIRING |
| 335 | LIGHT/FAN/5A POINT, WIRING, MOD SWITCH |
| 336 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit eithe r on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the followin g Make of Insulated wires shall be as per approved make |
| 337 | SUBMN WIRE-2X1.5SQMM,EARTHWIRE 1X1.5SQMM |
| 338 | SUBMN WIRE-2X2.5SQMM,EARTHWIRE1X2.5SQMM |
| 339 | SUBMN WIRE-2X4SQMM,EARTHWIRE 1X4SQMM |
| 340 | SUBMN WIRE-2X16SQMM,EARTHWIRE 1X16SQMM |
| 341 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per f ollowing details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's sp ecification and direction of Engineer In-charge. |
| 342 | S&F SWITCH WITH 1 OR 2 MODULE FRAME |
| 343 | S&F SWITCH WITH 3 MODULE FRAME |
| 344 | S&F SWITCH WITH 4 MODULE FRAME |
| 345 | S&F SWITCH WITH 6 MODULE FRAME |
| 346 | S&F SWITCH WITH 8 MODULE FRAME |
| 347 | S&F SWITCH WITH 12 MODULE FRAME |
| 348 | S&F 6A MODULAR SWITCH |
| 349 | S&F 15 A MODULAR SWITCH |
| 350 | S&F 6A, 3 PIN MODULAR SOCKET |
| 351 | S&F 15 A 6 PIN MODULAR SOCKET |
| 352 | S&F FAN REGULATOR OF STEPPED MODULAR |
| 353 | Supply & fixing of 300mA RCCB of approved Make of following ratings: |
| 354 | S&F RCCB - 4 POLES, 63A |
| 355 | Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. |
| 356 | S&F MCB+ELCB UPTO 32A SP MCB |
| 357 | S&F MCB+ELCB UPTO 32A DP MCB |
| 358 | Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs |
| 359 | S&F MCB DB WITH 4 WAY (4+12) TPN |
| 360 | SWITCH FUSE UNIT WITHOUT FUSE Supply & fixing switches/accessories in sheet metal enclosure including providing of required connec tions with supply of necessary cable/conduits as required in case of existing control switch panel/ switch board etc. all complete as per specification and direction of Engineer-In-Charge.( SFUs shall be of approved make and SFUs shall be without fuse) |
| 361 | S&F 100AMP TPN SWITCH FUSE UNIT |
| 362 | HOARDING LIGHTS:30W WITH IP65 PROTECTION |
| 363 | LED TUBE LIGHT: 18W WITH IP65 PROTECTION |
| 364 | LED TUBE LIGHT: 8W WITH IP20 PROTECTION |
| 365 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 366 | S&I 1200 MM SWEEP CEILING |
| 367 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). |
| 368 | S&I 9\\" LIGHT DUTY EXHAUST FAN KHAITAN/EQ |
| 369 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make |
| 370 | Providing and fixing H type double tone SS Pull handle of GODREJ (7268) or equivalent make |
| 371 | Providing and fixing Chrome Finish SS Health faucet with 8mm dia, 1 meter long |
| 372 | Stainless Steel Handrail:Providing and fixing |
| 373 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-c hambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corne rs, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjace nt finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all co mplete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shal l be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth and width of profile shall be a cceptable. |
| 374 | Two track two panels sliding window made of (small series) frame |
| 375 | Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi- chambered frame, sash and mullion (where ever required) extruded. profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel sect ion made from roll forming process of required length (shape and size according to uPVC profile), uPVC extruded glazing beads of app ropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion weld ed including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacen t finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all com plete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid se parately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account account shall be mad e. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth and width of profile shall be acceptable. |
| 376 | Casement window single panel with S.S. friction hinges |
| 377 | WALL HUNG COMMODE |
| 378 | Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes confo rming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. |
| 379 | 160MM UPVC COUPLER |
| 380 | 160MM UPVC SINGLE PUSHFIT COUPLER |
| 381 | UPVC SINGLE T WITH DOOR 160X160X160MM |
| 382 | UPVC SINGLE T WITHOUT DOOR - 160MM |
| 383 | UPVC 87.5 DEGREE BEND OF 160MM |
| 384 | UPVC PLAIN SHOE OF 160MM |
| 385 | S/F UNDER CANOPY RECESS MOUNTED 80W LINEAR LIGHT (2.4 m) |
| 386 | COUNTER SUNK WASH BASIN Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
| 10 | Click here to download tender document | Tender Documents |
| 11 | Click here to download tender document | Tender Documents |
| 12 | Click here to download tender document | Tender Documents |
| 13 | Click here to download tender document | Tender Documents |
| 14 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail