| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)---(a) With earth obtained from excavation of foundation. |
| 3 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 4 | Cement concrete with graded stone ballast (40 mm size excluding shuttering). In ground floor and foundation.(A) Pakur Variety. 1:3:6 proportion. |
| 5 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).--- a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.In Gr. floor. |
| 6 | 25 mm to 30 mm shuttering without staging in foundation etc. |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bennding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.i) JSW /JSPL /SHYAM /SRMB /BMASL/ ELECTROSTEEL/SSL(a) In Ground Floor and Foundation. |
| 8 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm.nominalsize) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.--a) Pakur Variety. i) 2nd Floor |
| 9 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. (i) Pakur Variety.( I ) In Ground Floor & Foundation. |
| 10 | Brick work with 1st. Class bricks in C.M. ( 1: 6) In foundation and plinth |
| 11 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. ( a ) Gr. Floor. |
| 12 | Labour for Chipping of concrete surface before taking up Plastering work. In ceiling, beam sides & soffit, column faces, staircase etc. |
| 13 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Exxcluding cost of chipping over concrete surface.] With 1:6 cement mortar 20 mm. thick plaster . In ground floor. |
| 14 | In first floor. |
| 15 | In Second floor. |
| 16 | In Third floor. |
| 17 | 15 mm. thick plaster. In ground floor. |
| 18 | In first floor. |
| 19 | In Second floor. |
| 20 | In Third floor. |
| 21 | With 1:4 cement mortar. 10 mm. thick plaster In ground floor. |
| 22 | In first floor. |
| 23 | In Second floor. |
| 24 | In Third floor. |
| 25 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu. M. per sq.m. |
| 26 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick). |
| 27 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper / acrylic emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C One coat. i) Water based interior grade acrylic primer. |
| 28 | Applying Acrylic emulsion paint of approved make and brand on walls and ceiling including sand papering in intermidiate course including putty (two coats). Standard Quality. |
| 29 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.--- a) Normal Acrylic Emulsion .(Two Coat). In ground floor. |
| 30 | In first floor. |
| 31 | In Second floor. |
| 32 | In Third floor. |
| 33 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C (One coat on new surface.) In ground floor. |
| 34 | In first floor. |
| 35 | In Second floor. |
| 36 | In Third floor. |
| 37 | Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original..removal of old paint.) |
| 38 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 39 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (a) On timber or plastered surface : With other than (hi-gloss) -(iv) Two coats (with any shade except white) |
| 40 | On steel or other metal surface : : With other than (hi-gloss) -(iv) Two coats (with any shade except white) |
| 41 | 18 mm to 22 mm thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @ 2.0 kg/Sq.m]. In ground floor. |
| 42 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3)including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]i) Ground Floor |
| 43 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone. |
| 44 | Extra cost of labour for grinding Kota stone Floor in treads and riser of steps. |
| 45 | Supplying, fitting and fixing Marble Slab/Tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av0 thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in- charge. (White cement and Pigment to be supplied by the Agency)-- (a) With Makrana plain pink/ Adranga Pink/ Makrana plain pink/ Garbh Gulabi/ Udaypur Green/ Black Bhaslana.--Area of EACH Slab/ tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m.(i)In ground Floor |
| 46 | In first floor. |
| 47 | In Second floor. |
| 48 | In Third floor. |
| 49 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps,railing, window sill etc. of Marble Stone. |
| 50 | Extra cost of labour for Marble Stone Floor in treads of Steps |
| 51 | Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curingcomplete. White cement, Pigment to be supplied by theAgency (a) With Makrana plain pink/ Adranga Pink/ Makrana plain pink/ Garbh Gulabi/ Udaypur Green/ Black Bhaslana.--(i) Area of each Slab/tile upto 0.3 sq.m. i)in ground floor |
| 52 | In first floor. |
| 53 | In Second floor. |
| 54 | In Third floor. |
| 55 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-inCharge.(White cement, synthetic adhesive and grout material to be supplied by the contra conc.II) With Polymerised Adhesive [6 mm thick] & epoxy grouting materials for filling joints including spacer-2 mm.(A) Light Colour. (i) In ground floor. |
| 56 | In firsrt floor. |
| 57 | In Second floor. |
| 58 | Supplying and laying chequered tiles of any shade & ofapproved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety(i) 25 mm. thick |
| 59 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.--Flash butt welded windows and ventilators--(no shop priming will be allowed to facilitate inspection of workmanship) Without integrated grills Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bar (i) In Ground floor |
| 60 | In first floor. |
| 61 | In second floor. |
| 62 | Fixed type steel windows as per IS sizes with horizontal glazing bars.i) In Ground floor |
| 63 | In first floor. |
| 64 | In second floor. |
| 65 | M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. |
| 66 | Two point nose steel handle including fitting and fixing. |
| 67 | steel peg stay 300 mm long including fitting and fixing. |
| 68 | Supplying best Indian sheet glass panes set in .. with nails and putty complete. (In all floors for internal wall.. for external wall).(i) 4 mm thick (weighing 7.4 kg/Sq.m) |
| 69 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S. clamps. (The quantity shoud be corrected upto three decimals).--- Sal : Local. (i) In Ground Floor |
| 70 | In first floor. |
| 71 | In second floor. |
| 72 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide EACH and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood vveneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings . 35 mm thick shutters (single leaf)--(i) In Ground Floor |
| 73 | Supplying, fitting and fixing M.S. clamp for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction.(Cost of cement concrete will be paid separately)--(The concreting will have to be done for equivalent thickness of 2 layers of brick work and for the entire width of the wall. No deduction on brick work will be made).40mm. X 6mm, 125mm. Length. |
| 74 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vi) 100mm. X 50mm. X 1.25mm. |
| 75 | Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge.(a) 250 mm long |
| 76 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. |
| 77 | Supplying 125 mm. Dia. Acrylic handle for aluminium door as per approved make and brand. (a) natural colour. |
| 78 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..--(ii) 66mm x 70mm I) In Ground Floor |
| 79 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.----(i) 32 mm thicki)In ground floor. |
| 80 | In first floor. |
| 81 | In second floor. |
| 82 | Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for EACH vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer‟s specification and direction of Engineer-in-Charge. |
| 83 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-chargei) In Ground Floor |
| 84 | In first floor. |
| 85 | In second floor. |
| 86 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracigs properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. ---In ground floor.--(Payment will be made on the area of the gate covered by two guard rails and two extreme channels)---(a) In ground floor. |
| 87 | Labour charge for fabrication and installation of composite door, window, partition made from extruded alloy aluminium sections for the following units:-(A) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge.(The rate includes the hire charge of all tools and plants, adhesive, joineries such as screw, cleate angle etc. but excluded the cost of extruded sections, glass, panel boards, neoprene / EPDM gasketing, locking arrangement, weather gasketing / wool pile, floor spring, top pin, handle tower bolt, glazing clips etc. ) i) In ground floor. |
| 88 | In first floor. |
| 89 | In second floor. |
| 90 | Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (A) Partly glazed and partly panelled partition or fixed glazing made of extruded and anodised alloy aluminium sections, fabrications after cutting to proper shape and size, drilling and aligning fitted with inbuilt locking arrangement cutting the glass / board (prelaminated / particle / block) to requisite shape and size moulding the edges fitted and fixed glazing clips and dry set neoprine /EPDM gasket, along with all other necessary arrangements for fixing the partition to walls, floors, beams,columns polysulphide sealant for water proofing if necessary complete in all respect as per drawing and specifications and direction of the Engineer in charge.The rate includes the hire charge of all tools and plants, adhesive,joineries such as screw, fastener but excluding the cost of extruded aluminium sections, EPDM gasket, glass, board, glazing clips, locking arrangement, etc.I) For partitions using section of size:a) 63.50 mm x 38.10 mm. i) in Gr floor |
| 91 | In first floor. |
| 92 | In second floor. |
| 93 | Supplying profiles of required section(approx. 2.0 mm or above as required) made of Aluminium Alloy Extrusions conforming to IS 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified color / natural) matt finished conformating to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work)..(A) In 10-12 Micron thickness Annodizing film. Natural white.I) Movable door shutter.---i)Door frame. (Top & sides). |
| 94 | Shutter. Top Rail (50x44.50x2.5mm) |
| 95 | Bottom Rail (100x44.50X2.5mm) |
| 96 | Lock rail (100x44.50X2.5mm) |
| 97 | Door vertical (85x44.45x2.0mm) |
| 98 | Glazing clip |
| 99 | Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.). Top , bottom & side member. |
| 100 | Intermediate member. |
| 101 | Glazing clip. |
| 102 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.--For Openable/ Casement windows..'U' shaped EPDM gasket for frames. |
| 103 | Weather gasket / Wool pile for door vertical. |
| 104 | Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -charge.--I) 100 mm. |
| 105 | Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. (b) Medium (I.S.I. size 2) |
| 106 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.i) 6mm thick clear glass. |
| 107 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of clipping the sides for better attachment as per direction of Engineer-in-charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. Glossy/Matt/Suede excluding surface texture or metallic lustre. (i) Thickness of laminate 1.5mm |
| 108 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:--(a) With continuous plate base (hexagonal/round rod)(v) 125mm grip x 12mm dia rod. |
| 109 | Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge.(a) 300 mm long |
| 110 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket reducing tee, short piece etc. fitted with holder bats clamps, including, cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) PVC Pipes(Dia)20 mm Dia |
| 111 | 25 mm Dia |
| 112 | 40 mm Dia |
| 113 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only) 40 mm. dia. |
| 114 | 25 mm. dia. |
| 115 | Supplying, fitting and fixing bib cock or stop cock (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand |
| 116 | Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand). |
| 117 | Supplying, fitting and fixing pillar cock of aooroved make.a) (i) CP Pillar Cock - 15mm dia(Equivalent to Code No. 507 & Model - Tropical / Sumthinhg Special of EESCOor similar brand). |
| 118 | Wash basin white vitreous china of approvedmake (without fittings) supplied, fitted and fixed in position on 75mm X 75mm X 75mm. Wood blocks and C.I. brackets including two coats of painting of C.I.brackets.550 mm X 400 mm. |
| 119 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm. x 75 mm. X 75 mm. wooden blocks complete..(ii) 470 mm X 280 mm X 340 mm |
| 120 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specificatioons with P.V.C. fittings completre, C.i. brackets including two coats of painting to bracket etc. |
| 121 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete i) Polythene Flush Pipe |
| 122 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm. thick with silvering as per I.S.I specifications supported on fiber glass frame of any colour, frame size 550mm x 400mm. |
| 123 | Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass(i) 25 mm. dia. and 600 mm. long. |
| 124 | Supplying, fitting and fixing porcelin soap tray of approved make.(i) Recessed soap tray of size 150 mm. X 150 mm. |
| 125 | Supplying fitting & fixing UPVC Pipes A type and fitttings conforming to IS 13592-1992 with all necessary clamps, nails including making holes in walls, floors etc cutting trenches in any soil through masonary concrete structures etc, if necessary, and mending good damages including joining with jointing materials.(for rain water draining) UPVC Pipes of 110 mm dia. |
| 126 | Plain Tee (UPVC), 110mm dia. |
| 127 | UPVC Shoe, 110mm dia. |
| 128 | Bend 87.5 degree of 110mm dia. |
| 129 | Stripping off worn out plaster and raking out joints of walls, ceillings etc. upto any height and in any floor including removing rubbish and stacking anywhere within the compound as directed. |
| 130 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 131 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m In ground floor including roof. upto 150 mm. thick |
| 132 | Dismantling R.C. floor, roof, beams etc.including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. In ground floor including roof. |
| 133 | Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). |
| 134 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). (a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 135 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] |
| 136 | Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface. |
| 137 | Cleaning and removing paint mark from glass pane with spirit and removing strains etc. |
| 138 | Repairing crack in wall by cement grouting (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) and finishing off to match with adjacent surface. (Cement-69 Kg/100 m) |
| 139 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 140 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. c) Upto 50 users:-ii) Beyond a lead of 150 metre and outside the Municipal limit |
| 141 | Cleaning silt of inspection pit. |
| 142 | Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats. |
| 143 | Easing and oiling, cleaning collapsible gate and repairing to locking arrangements. |
| 144 | Labour for taking out rolling shutter (only shutter portion) dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs |
| 145 | Easing and oiling, cleaning rolling shutters excluding repair toinside locks. |
| 146 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.-----I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 147 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 148 | Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge. for Structural Glazing/Curtain wall. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work |
| 149 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5 (c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base,sub-base course & subgrade preparation.) Coloured Decorative |
| 150 | Supplying, fitting & fixing 600mm long (+/-30mm) diameter RBT (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx 6 meters length at site clipped with two nos of horizontal RBT strads which will be tensioned and fixed with the vertical M.S angle iron post by means of security fasteners. |
| 151 | (a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut conditionwith straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. Please Enable Macros to View BoQ information |