| 1 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. |
| 3 | Providing Earth filling in Foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 4 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 Coarce sand (zone-III): 6 Grade stone aggregate 40 mm nominal size)- At Foundation |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Foundation |
| 8 | Reinforcement cement concrete work in walls (any thickness), including attached pilasters, buttersses, plinth and string cource, filleets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Columns |
| 9 | Reinforcement cement concrete work in walls (any thickness), including attached pilasters, buttersses, plinth and string cource, filleets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Plinth Beam |
| 10 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specication and direction of E/I. |
| 11 | Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1 Cement : 2 Coarce sand (zone-III) : 4 Graded stone aggregate 20 mm nominal size) |
| 12 | Providing designation 75 B brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 13 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Lintel Band |
| 14 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Lintel |
| 15 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Roof Level Beam |
| 16 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Roof Slab |
| 17 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Stair Case |
| 18 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size)- At Chajja |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 25 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, applying a prim ing red lead paint over steel work,taxes all complete as per specification and direction E/I. |
| 26 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 27 | Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2:4) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/I |
| 28 | Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 29 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab beam at the time of casting all complete as per building specification and direction of E/I. |
| 30 | Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 31 | Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 32 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 33 | Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with flor, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 34 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 35 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 36 | Supplying, fitting & fixing C.A.R.W.D. pipe with necessary strips, spikes, bends, shoes etc. including cost of carriage all complete as per building specification and direction of E/I. |
| 37 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500(a) 8 mm dia. |
| 38 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 (a) 10 mm dia. |
| 39 | (b) 12 mm dia. |
| 40 | (c) 16 mm dia. |
| 41 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand . 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 42 | Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. |
| 43 | Carraige of materials by truck or any other mechnical means with all complete job (A) Briks (1+7) KM |
| 44 | (B) Local Sand (up to 3 KM) |
| 45 | (C) Coarse Sand (up to 50 KM) |
| 46 | (D) Stone Chips( upto 22 KM) |
| 47 | (E) Metal (up to 22 KM) |
| 48 | Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/M.S box etc. as required. |
| 49 | Wiring for light/power plug with 2x 4 sq.mm FR PVC insulated, copper conductor ,single core cable in and surface/recessed PVC conduitalong with 1 No. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as requried . |
| 50 | Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor , single core cable in surface/ recessed PVC coduit as required. 2X1.5 sq mm+1X1.5 sq mm |
| 51 | 2X2.5 sq mm+1X2.5 sq mm |
| 52 | 2X6 sq mm+1X6 sq mm |
| 53 | S/F 2 pin, 5amp. Ceiling rose on the existing junction box / wooden block including connection etc.as reqd. |
| 54 | S/F brass battan / angle holder including connection etc.as reqd. |
| 55 | S/F of following sizes of PVC conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required . 20 mm PVC coduit. |
| 56 | 25 mm PVC coduit. |
| 57 | Supplaying and fixing following piano type switch / socket on the existing switch box / cover including connection etc. as reqd. 5/6 amps, one way switch |
| 58 | 3 pin 5/6 amps, socket outlet |
| 59 | S/F Sheet metal ON/OFF-Load Changeover:- Providing and fixing following capacity 2 pole/4pole ON/OFF-load changeover switchs with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal board, making connection, earthing the body etc .as required |
| 60 | S/F Modular type Electronic Fan Regulator-Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 61 | Supply and fixing 1200mm BLDC 5 star rating 32W Ceiling Fan |
| 62 | Supplying and fitting and fixing 9/10 watt LED Bulb |
| 63 | Supplying and fixing metal box of following sizes(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd. 126 mm x 277 mm x 61 mm deep |
| 64 | upplying and fixing of following way single pole & neutral, sheet steel , MCB distribution board 240 volts, on surface /recess , complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder pointed including earthing etc. as reqd. 8 way double door. |
| 65 | Add cost of 18 % GST |
| 66 | Add cost of S/B and photo graphy |
| 67 | Add cost of 1 % Labour cess |
| 68 | Add cost of Ramp Please Enable Macros to View BoQ information |