Tender For Providing Installing And Commissioning Of Residual Chlorine Indicator Alongwith Full Mechanism To Link With Scada System Including 3 Years O&M At 6 Mld Stp Jaitu Town, District Faridkot (Under Jal Hi Amrit Scheme), Moga-Punjab
TDR : 54386982
Tender Notice
BOQ
1 Days Left
Moga
Punjab
Tender For Providing Installing And Commissioning Of Residual Chlorine Indicator Alongwith Full Mechanism To Link With Scada System Including 3 Years O&M At 6 Mld Stp Jaitu Town, District Faridkot (Under Jal Hi Amrit Scheme)
Name of Work:- Providing installing and commissioning of Residual Chlorine indicator alongwith full Mechanism to link with SCADA System including 3 Years O&M at 6 MLD STP Jaitu Town, District Faridkot (Under Jal Hi Amrit Scheme)
Sl. No.
Item Description
1
Providing, Fixing, Testing & Commissioning of Residual Chlorine Analyzer, Electrical control panel for Automation system & integration of Data with the existing sewer of required specification.
2
Residual Chlorine Analyzer: 5 ppm, Sample pH range:8.5, Marerials of Construction: Body Material PVC, Membrane, Cap Material PVC housing, Proprietry Membran, Measuring Water Temprature & Pressure: 0 to 45° C % 14.7 psig (1 Bar), Sensor Protection: IP-65, Cross Sensitivity Chlorine dioxide, Ozone, iodine with 1x4-20mA output, 1xRS-485, Display 4 Digit, 7 Segment, Red Character height of 0.56, pH Compensation Manual. PH Value entry through keypad, Transmitter Power Supply 85 to 230 VAC, 50/60HzMake: Forbes Marshal, Horiba, E&H
3
Power Coated and CNC fabricated electric control panel for Automation System of 14 SWCG CRCA sheet thickness and which includes PLC (Programmable Logic Controller) with appropriate digital and analog inputs and outputs to give automatic commands to field equipment, Electronic relay card 8 channel, SMPS 4.5 Amps to energise PLC system, HMI (Human Machine Interface) 7\\" display for Monitoring and Controlling. Mobile App (Android/lOS) with user ID and password to monitor and control the pumping operation of chlorinator and also to analyze the history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, etc,Make: Aarmation Electric.
4
Integration of Data with existing Server
5
The scope includes providing comprehensive operation and maintenace services for the Residual Chlorine Analyzer installed at the Sewerage include:
6
Residual Chlorine Analyzer Maintenace-1. Monthly Maitenance: Perform routine Maintenance tasks, including cleaning and inspecting the analyzer, to ensure optimal performance.2. Calibration:- Calibrate the residual Chlorine Analyzer on a monthly basis to ensure accurate reading. - Use calibrated standards and follow the manufacture's instructions for calibration.3. Functionally Check: - Verify that the analyzer is functioning correctly and providing accurate readings. - Identify and troubleshoot any issues or faults with the analyzer.4. Record Keeping: - Maintain detailed records of* maintenance activities, calibration, and repair of the Residual Chlorine Analyzer. - The Scope of work shall be for a period of 3 years from the date of commencement. Please Enable Macros to View BoQ information