| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 2 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 4 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 5 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 6 | 25 mm dia (heavy type) |
| 7 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 8 | 65 mm |
| 9 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 10 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 11 | 200 mm |
| 12 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 13 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 14 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 15 | Glazed vitrified floor tiles polished finish of size : Size of Tile 600 x 600 mm |
| 16 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 17 | Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 18 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 19 | Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 20 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity |
| 21 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the dumping ground notified by MCD Delhi within any lead as per direction of Engineer - in - charge. |
| 22 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 23 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead and disposal of malba to the dumping ground notified by MCD Delhi within any lead : |
| 24 | Of area 3 sq. metres and below |
| 25 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material within 50 metres lead and disposal of unserviceable material to the dumping ground notified by MCD Delhi within any lead. |
| 26 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 27 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 28 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 29 | Kitchen sink with drain board : 510x1040 mm bowl depth 250 mm |
| 30 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 31 | For fixed portion : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 32 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 33 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 34 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 35 | Providing and fixing 4mm thick Aluminium Composite Panel in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. all complete as per directions of Engineer-in-charge. |
| 36 | Granite work (Polished and machine cut) of thickness 16 mm for wall lining (veneer work) backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand) including pointing with white cement mortar 1 :2 (1 cement : 2 marble dust) with an admixture of pigment to match the granite shade. (To be secured to the backing by means of cramps, which shall be paid for separetely). : Granite of any colour and shade. (Sample and colour shall be approved by Enigneer in Charge) : Area of slab upto 0.50 Sqm |
| 37 | Providing and fixing heavy type blackout cotton curtain cloth 140–180 GSM or as directed and approved by Engineer-in-charge, for office doors/windows made of 100% cotton fabric of approved size, shade, colour and quality including cutting, stitching, hemming, pleating, eyelets, hooks, accessories and fixing etc. all complete as per direction of Engineer-in-Charge. |
| 38 | Manufacturing, supplying and fixing retro reflective signage boards made up of 4 mm thick ACP sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to Type-III of ASTM-D-4956-01 as approved by Engineer-in-Charge, letters, borders, logo etc. as per IRC: 67-2001 shall be printed on blue/green colour back ground and Digital Muthoo Printing with high quality white or any required colour as per direction of Engineer-in-charge and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including lamination on Retro Reflective Sheet with required thickness of PVC sheet. The rate includes the cost of rounding off the corners, and erecting the same in position all complete as per drawings, specification and direction of the Engineer-in Charge. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). |
| 39 | Overhead informatory road signage |
| 40 | Credit to the work for dismantled material received during execution of work at site. (a) Unserviceable flush/PVC/Wooden door shutters.Note: Actual quantity of the material to be measured for payment. |
| 41 | Credit and disposal of old damaged and dismantled Steel/Iron/M.S/G.I/C.I and other similar articles (The material will be the property of contractor)Note: Actual weight of the material to be measured for payment. Please Enable Macros to View BoQ information |