| 1 | Schedule 'A' Section - I |
| 2 | Rough excavation not exceeding 1.50 metre deep and getting out in soft/disintegrated rock complete all as specified and as directed. |
| 3 | Rough excavation exceeding 1.50 metre deep but not exceeding 3.00m in depth getting out in soft/disintegrated rock complete all as specified and as directed. |
| 4 | Excavation over areas not exceeding 1.50 metre deep and getting out in hard/dense soil complete all as specified and as directed. |
| 5 | Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed. |
| 6 | Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed. |
| 7 | Material and Labour for raised pointing to random or polygonal rubble, uncoursed or brought upto course in Cement mortar 1:4 , complete all as specified. |
| 8 | Material and Labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate) as in fixing of hold fasts, copings, bed plates,kerbs or mud stops, lintels upto 1.50m span, plinth courses , seismic and other bands and the like, finished the surface fair and even, including necessary form work complete all as specified and directed. Note- If reinforced concrete, reinforcement shall be measured and paid for separately. |
| 9 | Material and Labour for pre-cast cement concrete type C-1 1:3:6 (using 20 mm graded mechanically crushed stone aggregate), as in bond stone, etc. set in cement mortar (1:6), complete all as specified and directed. |
| 10 | Material and labour for dry hand packing (any thickness) of broken stone or boulders, at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and as directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.. |
| 12 | Removing excavated soil to a distance exceeding 250 metre but not exceeding 500 metre and deposited where directed complete all as specified and as directed. |
| 13 | Supply and fixing 75mm dia UPVC, soil waste drain pipe, type ‘B’ , conforming to IS 13592-1992, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wall, complete all as specified and directed. |
| 14 | Excavating in posts holes (or similar holes) each n.exc 0.50 cum getting out and removing surplus soil to a distance exc 50 metre but n.exc 100 metre and making good surface complete all as specified and directed. |
| 15 | Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation, filling and mass concrete, complete all as specified and directed. |
| 16 | Supply and fixing roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (web, tee, angle, channel or flat sections) including distance pieces, cleats etc fixed in position,conforming to Fe-410(Gde 250), complete all as specified and as directed. |
| 17 | Material and labour for two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified. |
| 18 | Supply and fixing of Pre-painted galvalume aluminuim zinc coating GI based corrugated steel sheet 0.50mm thick, conforming to IS-15961 of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and as directed.Note- The sheets shall have (150 gm/sqm total on both sides) with super durable polyester quality paint of approved colour, suitable for exterior application conforming to IS-15965. |
| 19 | Material and labour for brick work with sub class ‘B’ bricks burnt, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified |
| 20 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 21 | Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 22 | Material and labour for broken stone hard core of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 23 | Material and labour for 100 mm thick plain cement concrete, 1:2:4 type B1 using 20mm graded stone aggregate as in floor laid in alternate bays finishing cement concrete surface and making impressions of expended metal while the concrete is green complete all as specified and directed . |
| 24 | Supply and fixing chequered cement concrete tiles, rubber moulded with laquer polish for extra shine, size 300 mm x 300 mm x 22-25 mm thick, ISI marked, coloured, set jointed and pointed in neat cement slurry over cement screed complete all as specified |
| 25 | Material and labour for cement screed bed 15mm thick in cement mortar (1:6) base for laying floor finish complete all as specified and as directed. |
| 26 | Material and labour for rendering 15 mm thick on surface of any description of brick work or concrete wall surfaces in cement mortar 1:4 mixed with water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed.( Note- Supply only integral WPC shall be measured and paid separately) |
| 27 | Material and labour for preparation of plastered or unplastered new surfaces of walls of and applying two coat of cement base paint over a coat of cement priming coat of any approved tint complete all as specified & as directed. |
| 28 | Supply only integral water proofing compound complete all as specified and as directed. |
| 29 | Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/disintegrated rock complete, all as specified and as directed. |
| 30 | Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate) as in surface channels and drains, complete all as specified and ditected. |
| 31 | Material and Labour extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds , mitred /stopped ends etc., complete all as specified and directed. |
| 32 | Material and Labour for form work to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work rough finished flat surfaces of concrete complete all as specified and as directed. |
| 33 | Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only.b) Switch, socket outlet and fan regulators to be measured and paid for separately . |
| 34 | Description Same all as per item No. 32.00 but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Description Same all as per item No. 32.00 but for One 3 pin 6 Amps socket outlet controlled by one switch on Same board, complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Supply & fix modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | Supply and fixing indoor decorative LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient aluminium housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed. |
| 40 | S&F LED Bldg Security Light Fittings of capacity 20 -25 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver, service bracket of mild steel pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed. |
| 41 | Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. |
| 42 | Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'C' curve as per site requirement complete all as specified and as directed by the Engineer-in-Charge. |
| 43 | Supply and fix MCB SPN, 40 Amps, 240 volt,10 KA , 'C' curve as per site requirement complete all as specified and as directed |
| 44 | Supply, laying, commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 10 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed. |
| 45 | Material & labour for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and light grade GI wire protection pipe 15mm bore up to main board complete as shown in electrical plate No. 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unserviceable earthing complete all as specified and testing on completion complete all as specified and directed.Note - The units rate includes the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (medium grade) for watering 40mm GI pipe for protection of wire (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. Please Enable Macros to View BoQ information |