| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | Average run 8mtr |
| 3 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. |
| 4 | On Board |
| 5 | Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [CPU Board] |
| 6 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 20A Plug Point] |
| 7 | Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Power Board] |
| 8 | Supply & Fixing 240 V 6A Piano key type switch (Brand approved by EIC)on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 9 | Supply & Fixing 240V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite / perspex top cover by screws after making housing for plug by cutting bakelite/ perspex top cover and making necy.connections with PVC wire and earth continuity wire etc. |
| 10 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.2+12Way[ Legrand ] Incoming- DP MCB Isolator 63 A- 1 noOutgoing- SPMCB 6-32 Amp- 12 nos |
| 11 | S&F 415 V, 16-32A per way, 6 way Horizontal TPN MCBDB with SS enclosure, double door with IP 42/43 protection concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment . (Make -legrand ) [14/ D-10] Incoming - FP MCB Isolator 63A-1. Outgoing :6 A -32 A SPMCB-18 nos. |
| 12 | Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required |
| 13 | 2x(1.5 sqmm)+1x(1.5 sqmm) |
| 14 | 2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug/Outdoor light) |
| 15 | 2x(4 sqmm)+1x(2.5 sqmm) (A.C) |
| 16 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [HTPN DB to SPN DB] |
| 17 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 18 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 19 | 1.5sqmm |
| 20 | 2.5sqmm |
| 21 | 4 sqmm |
| 22 | 6 sqmm |
| 23 | 10 sqmm |
| 24 | Supply of 2/3.5 /4Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Havells / Gloster] |
| 25 | 4core35 Sq. mm |
| 26 | Laying of cable from 3/3½ /4core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 27 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoringsurface duly rammed |
| 28 | Supplying and fixing compression type gland those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. |
| 29 | 4Core 35 Sq. mm |
| 30 | Supplying and fixing crimping type finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. |
| 31 | 4Core 35 Sq. mm |
| 32 | Fixing only single/twin fluorescent light fitting in the ceiling/ wall fixed with “L” type MS clamp as per GS |
| 33 | Fixing only lamp |
| 34 | Supply of 4ft LED T-8 box type batten with end cap complete with all accessories (make Crompton) |
| 35 | (i) Sigle tube fittings, Cat No- IGP161LT8-16 1 x T8 |
| 36 | (ii) Tube Light , cat No- LTT8-16 |
| 37 | Supply 9W LED lamp to the lamp point. [PHILIPS make] |
| 38 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy.connections etc. |
| 39 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS |
| 40 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS. |
| 41 | Fixing only exhaust fan after making holes in wall as per GS |
| 42 | (12\\") |
| 43 | Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS |
| 44 | (12\\") |
| 45 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 46 | Supply & Delivery of ceiling fans complete with P2 condencer & Safety wire all accessories having the following Model / Cat No. ( Make -Crompton Greaves high speed (HS)/Orient- New Breeze/ Usha Striker PWD) |
| 47 | 1200 mm Sweep ( High Speed ) |
| 48 | Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) |
| 49 | 12\\"( 300mm ) Speed 920 RPM |
| 50 | Supply & delivery of 400 mm sweep wall fans complete with full metal body & P2 type condencer with all accessories the following model. Make- EPC/ Orient. |
| 51 | Supply of 2 Core PVC/XLPE Insulated & Sheathed Armoured/unarmoured Aluminium/Copper Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Havells/Gloster/RR Cable] |
| 52 | 6 Sq. mm |
| 53 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth asbelow and mending good the damages to original finish incl. removing the rubbish |
| 54 | From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. |
| 55 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. |
| 56 | Upto 6 Sq mm For 2 core |
| 57 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 58 | Upto 6Sq mm For 2 core |
| 59 | Supply & fixing SMC Junction boxes of dimension (250 x200x105) mm with IP 67 Protection ( Sintex/Hensel) make for compound light. With 4 poole terminal stud and 6A 10KA C Curve SP MCB (make-Legrand) on wall |
| 60 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting |
| 61 | Supply & delivery of 90 Watt LED STREET Iight fittings with tafan glass aesthetically designed roadway with execellent thermal management and IP65 protection [ make- Crompton- CRP-411-90-57-SL-GL-NSG or equivalent of Transrail/Wipro). |
| 62 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: |
| 63 | By TATA-Medium GI pipe |
| 64 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 65 | Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS |
| 66 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 67 | Excavation of soil for installation of Earth Electrode and filling & ramming. For soft Soil |
| 68 | Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS |
| 69 | Supplying & Fixing 240 V AC/DC superior type Multitune ( min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW boar |
| 70 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required ISI-M 40 mm dia [ 11c/F-6 ] |
| 71 | Supply & fixing of EXIDE IMTT1500 150Ah 12 volt Tall Tubular Battery with 60*Month Warranty Tubular Inverter Battery (150Ah), Make- Exide including necessary connection of inverter by suitable copper wire after dismantling of existing battery. |
| 72 | Supply & fixing of EXIDE INVAMASTER IMTT2000, 12V 200Ah Tall Tubular Inverter Battery with Warranty - 60 Months, Make- Exide including necessary connection of inverter by suitable copper wire after dismantling of existing battery. |
| 73 | Repairing of existing 16.5 mtr high mast feeder pillar box including 1 no S&F digital time switch on din rail on existing box incl. necessary connection. L&T make crono time switch [cat no 67DDT0], S&F25A 3pole power contactor on din rail on existing box incl. necessary connection. L&T make MNX 25-2P [cat no CS 90240] & Supplying and fixing 415 V 32A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing box and necessary connection L&T make and necessary connection checking of existing flood light after bring down of light fittings. |
| 74 | providing shed for DG set by supply and Fixing galvanised corrogated G.I. sheet (1.8mm thick, Tata/Bhushan/Aarti) by suitable J hook, Nuts and bolts, washers on rectangular MS structure over 4 nos 50mm dia MS pipe(Tata/Bansal) height 3.5 meter from the DG paltform, the entire MS structure is to be painted by 1 coat RO primer and 2 coat synthetic enamel paint. Dimension -4200(L) x 2400(W) x 3500(H) in mm for 62.5 KVA DG set |
| 75 | Charges for replacement of defective indoor runner fan motor of different 2TR Split type A.C. Machine at different locations. |
| 76 | Charges for SITC & replacement of damaged condenser by new copper condenser coil. |
| 77 | Charges for replacement of defective ODU Fan Motor |
| 78 | Charges for replacement of damaged compressor of 2TR Split type AC Machine. |
| 79 | SITC of copper filter at the time of compressor and condenser replacement for smooth flow of refrigerant. |
| 80 | SITC of heat exchanger at the time of compressor and condenser replacement. |
| 81 | Fitting of new compressor by fixing of nut,bolts and gas welding with brazing,stick & other accessories to complete the re-assembling of the A.C. Machine. |
| 82 | Charges for thorough leak testing of the entire unit by gas pressure and vaccuamising for fresh gas charging. |
| 83 | Supply & filling of Refrigerant.r22 & r410 Please Enable Macros to View BoQ information |