| 1 | I-रा.उ.मा.वि. खुंटिया में किचन शेड निर्माण कार्यEarth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming disposal of surplus excavated soil as directed with a lead in a 50 mtr.All kinds of soil. |
| 2 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
| 3 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for foundation, footings, strap beam, raft, base of column etc UPTO PLINTH |
| 4 | Steel Reinforcement:-P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor three level TMT bars . |
| 5 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 6 | STONE MASONARY FOR FOUNDATION:- Random Rubble Stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in cement sand mortar 1:6 (1 cement : 6 sand) |
| 7 | Supply transporation etc. & Stacking good earth at site complete including loading unloading & transporation etc.Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 8 | Stone Kharanja: RR Dry stone kharanja under floor |
| 9 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level M 10 grade nominal Mix1:3:6 (1 cement:3 Coarse sand : 6 gradeed stone aggregate 20 mm nominal size). |
| 10 | Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 11 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor three level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. ABOVE PLINTH LEVEL |
| 12 | Providing and laying in position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement for : beams, suspended floors, griders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills,staircase and spiral staircase : M 20 grade nominal mix (with graded stone aggregate 20mm nominal size) |
| 13 | Providing and fixing M.S. sheet 1mm thick double leaf door shutter windows in angle iron frame 35x35x5 mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 14 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33%] |
| 15 | Wire Gauge Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at nut exceeding 150mm distance. |
| 16 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 17 | Guard Bars: P&F square bars or other flat welded to window/ventilators etc. |
| 18 | INTERNAL PLASTER Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick |
| 19 | External PLASTER Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick |
| 20 | Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand) |
| 21 | Grading roof for water proofing treatment with water proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
| 22 | Gola Providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. |
| 23 | Polishing Blue Kota stone flooring skirting laid over 20mm thick base of CM 1;4 and jointed with gray cement slurry to match the shade of the slab including rubbing and polishing complete : For area of each slab from 901 to 2000 Sq.Cm : (a) 25 mm thick slab |
| 24 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110mm dia |
| 25 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). 15 mm dia nominal bore B CLASS |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). 20 mm dia nominal bore B CLASS |
| 28 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 300 Litre capacity |
| 29 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : WVC Lab sink (IS:2556 mark) size 530 x 430 x 180 mm |
| 30 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : Brass 400 gm. 15 mm nominal bore. |
| 31 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: Brass 400 gm. 15mm nominal bore. |
| 32 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 400 gm, 15 mm |
| 33 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 34 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete .New Plastered Surface (three or more coats) |
| 35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 36 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 37 | PANTING ON DOORS & WINDOWS :- Painting with Synthetic enamel paint of approved brand and manufacture in all shade to give an even shade new steel work (2 or more coat on new work). |
| 38 | Lettering with black Japan paint of approved brand and manufacture. |
| 39 | II-रा.उ.मा.वि. नाहरी में किचन शेड निर्माण कार्यकार्यEarth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming disposal of surplus excavated soil as directed with a lead in a 50 mtr.All kinds of soil. |
| 40 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
| 41 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for foundation, footings, strap beam, raft, base of column etc UPTO PLINTH |
| 42 | Steel Reinforcement:-P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor three level TMT bars . |
| 43 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 44 | STONE MASONARY FOR FOUNDATION:- Random Rubble Stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in cement sand mortar 1:6 (1 cement : 6 sand) |
| 45 | Supply transporation etc. & Stacking good earth at site complete including loading unloading & transporation etc.Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 46 | Stone Kharanja: RR Dry stone kharanja under floor |
| 47 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level M 10 grade nominal Mix1:3:6 (1 cement:3 Coarse sand : 6 gradeed stone aggregate 20 mm nominal size). |
| 48 | Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 49 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor three level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. ABOVE PLINTH LEVEL |
| 50 | Providing and laying in position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement for : beams, suspended floors, griders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills,staircase and spiral staircase : M 20 grade nominal mix (with graded stone aggregate 20mm nominal size) |
| 51 | Providing and fixing M.S. sheet 1mm thick double leaf door shutter windows in angle iron frame 35x35x5 mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 52 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33%] |
| 53 | Wire Gauge Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at nut exceeding 150mm distance. |
| 54 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 55 | Guard Bars: P&F square bars or other flat welded to window/ventilators etc. |
| 56 | INTERNAL PLASTER Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick |
| 57 | External PLASTER Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick |
| 58 | Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand) |
| 59 | Grading roof for water proofing treatment with water proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
| 60 | Gola Providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. |
| 61 | Polishing Blue Kota stone flooring skirting laid over 20mm thick base of CM 1;4 and jointed with gray cement slurry to match the shade of the slab including rubbing and polishing complete : For area of each slab from 901 to 2000 Sq.Cm : (a) 25 mm thick slab |
| 62 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110mm dia |
| 63 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). 15 mm dia nominal bore B CLASS |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). 20 mm dia nominal bore B CLASS |
| 66 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 300 Litre capacity |
| 67 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : WVC Lab sink (IS:2556 mark) size 530 x 430 x 180 mm |
| 68 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : Brass 400 gm. 15 mm nominal bore. |
| 69 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: Brass 400 gm. 15mm nominal bore. |
| 70 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 400 gm, 15 mm |
| 71 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 72 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete .New Plastered Surface (three or more coats) |
| 73 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 74 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 75 | PANTING ON DOORS & WINDOWS :- Painting with Synthetic enamel paint of approved brand and manufacture in all shade to give an even shade new steel work (2 or more coat on new work). |
| 76 | Lettering with black Japan paint of approved brand and manufacture. |
| 77 | III-राउप्रावि डिकाणी में रिनोवेशन कार्यDismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead : : Of area 3 Square meter and below. |
| 78 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 79 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint Add extra for double leaf shutters. |
| 80 | Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at nut exceeding 150mm distance. |
| 81 | P&F square bars or other flat welded to window/ventilators etc. |
| 82 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 83 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 84 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 85 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 86 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 87 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25 MM THICK |
| 88 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1:3:6 or richer mix. |
| 89 | Random rubble dry stone Kharanja under floor. |
| 90 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level M 10 grade nominal Mix1:3:6 (1 cement:3 Coarse sand : 6 gradeed stone aggregate 20 mm nominal size). |
| 91 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 901 to 2000 Sq.Cm : |
| 92 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 93 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 94 | Distempering with oil bound washeble distemper of approved brand and manufacture to give an even shade including all scaffolding Old work (one or more coats) including scrapping surface and necessary repairs. COLOUR CHANGE |
| 95 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 96 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 97 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work Please Enable Macros to View BoQ information |