| 1 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as directed. |
| 2 | M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement.all as specified and directed. |
| 3 | M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using WPC (WPC shall be measured seperetly)on wall finishing the surfaces even and smooth without using extra cement. Complete all as specified and directed. |
| 4 | M&L for 10 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for preparing newly platered surfaces and applying two coat of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint over 1mm thick wall care putty on ceiling complete all as specified and directed |
| 6 | complete removal of existing treatment and applying two coats of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint over 1mm thick wall care putty on ceiling complete all as specified and directed |
| 7 | M&L for preparing newly platered surfaces and applying two coat of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint over 1mm thick wall care putty on walls complete all as specified and directed |
| 8 | complete removal of existing treatment and applying two coats of distemper oil emulsion white or tinted over priming plastered or other surface with alkalli-resistant priming paint over 1mm thick wall care putty on walls complete o all as specified and directed |
| 9 | M&L for preparing the new plastered surfaces and applying two coats of exterior Emulsion weather proof coat white or tinted on walls/soffit of chajja surfaces complete all as specified directed. |
| 10 | complete removal of existing treatment and applying two coats of exterior Emulsion weather proof coat white or tinted on walls/soffit of chajja surfaces complete all as specified directed. |
| 11 | Supply only integral water proofing compound. ISI marked |
| 12 | Taking down chowkhats or frame n.exc 1.50 Sqm each with shutter without taking of shutter from framed complete incl removing from site |
| 13 | Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4.00 Sqm each with shutter without taking of shutter from framed complete incl removing from site |
| 14 | Resecuring or easing and adjusting without taking down shutter of any description exc 1 sqm and n exc 2 sqm each complete all as specified & directed. |
| 15 | M&L for pressed steel frames for doors (105X60MM) with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed. |
| 16 | M&L for pressed steel frames (125x60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified & directed. |
| 17 | M&L for framed work such as grills, grating doors or gates etc. of angle iron, flat iron with ends of bars shouldered and or rivetted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings for terrace, framework of water tanks and similar work confirming to Fe 290. complete all as directed. |
| 18 | M&L for cement concrete type C-0,1:3:6 (12.50 mm graded crushed stone aggregate) as in coping, bed block , water trought and similar works including rounding, chamfered and throting complete all as specified and directed. |
| 19 | S&F flush shutter (35mm thick), solid core construction, with block board core and plywood face panels, commercial type on both sides and fitted to chowkats complete all as specified and directed. complete all as specified and directed. |
| 20 | S&F factory made 35 mm thick glazed and Skelton door shutter 2nd class HW (rail and style ) open rebated and prepared to receive glass / Gauged divided in to squares with plain chamfered or rounded mitred and rebated fitted with cut and mitered beads for securing glass/ gauged etc size of members of shutters as specified in SSR Part – I section-8, clause 8.24(a) and fixed to Chowkhats, complete all as specified and directed. |
| 21 | S & F powder coated anodised alm ventilator louvre type with two separate frame of size 50.5mmx40mmx1.5mm thick (01x frame for fixing of 5mm thick coloured glass & 01x frame for fixing SS wire mesh) powder coated anodised aluminium section weighing 0.55 kg/m including 5mm thick coloured glass, SS wire mesh and necessary joining cleats, glazing clips, rubber packing, side handles fixed to wall with fastener etc, complete all as specified & directed. |
| 22 | S&F powder coated Aluminium anodised hanging type glazed window manufactured with approved aluminium section with two hang shutters each shutter width same of the length of window with the following specifiecation and making good the adjascent surfaces :-(a) Two Nos Window frame of each window of cross section 50.5mmx40mmx1.5mm thick over all size 101mmx40mmx1.5mm thick, .(b) hanging type smooth shutters of cross sections 91.80mmx31.75mmx1.1mm thick. (c) hanging shutter frame of cross section 40x18x1mm.(d) Aluminium glazing stip of size 18.2x16.66mm. (e) 4mm thick flat glass superior quality for one shutter. (f) IDPE rubber gasket for fixing glass. (g) Aluminium aldropbolt 150mm, 2 No each shutter. (h) 02 Nos Aluminium handle 150mm per shutters. (j) aluminium wire cloth 0.36mm stainless steel nominal dia of wire and average width of aperature 1.40mm for one shutter (k) 2 Nos Each shutter 100mm mild steel butt hinges .(k) Fixing screws for frame with wall 06 per window with fancy design.(Note: Window will be measured outer to outer frame and no extra to be paid. The grill will be fixed between the two window frame. window iron grill will be measured and paid separately in respective item. |
| 23 | S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube S&F in opening all as shown on drawing and specified & directed. |
| 24 | S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rail with suitable PVC sheet bending and jointed to gather with solvent cement supplying and fixing in the frame at site as per specification and drawing incl 3 Nos butt hings, alluminium of size 100 mm long for each door |
| 25 | S & F in reapirs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 26 | S & F in Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 27 | S&F butt hinges 100mm long medium weight cold rolled MS and fixed complete all as directed at site |
| 28 | S&F 150 mm long aluminum anodized barrel tower bolt extruded section. |
| 29 | S&F aluminum handles cast type anodize 150 mm long. |
| 30 | S&F aluminium alloy anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alumionium alloy and fixed 300mm long. all as specified & directed. |
| 31 | M&L for applying two coat of synthetic enamelled paint over one coat of pink primer on new wooden surfaces of any description not otherwise described over 10cm width or girth including preparation of new surface all as specified and directed |
| 32 | M&L for applying one coat of synthetic enamel paint on old painted steel surface surfaces of any description not otherwise described over 10cm width or girth including preparation of surface all as specified and directed |
| 33 | M&L for applying one coat of synthetic enamel paint on old painted wooden surfaces of any description not otherwise described over 10cm width or girth including preparation of surface all as specified and directed |
| 34 | Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of same to exceeding 1 Km but not exceeding 1.5 Km complete all as specified and directed. |
| 35 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete. |
| 36 | S&F for glazed ceramic tiles coloured of size 350x250x7mm/450x350x7mm thick fixed in verticle surfaces, set and jointed in neat cement slurry and pointed in white and colour cement to match incl 10mm thick screed bed in CM 1:4 all as directed. |
| 37 | M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exceeding 0.06 sqm but n.exc 0.11sqm infloor etc,over 15 mm thick screed bed in CM(1:4),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. |
| 38 | M&L for coloured non skid cermic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed in CM 1:6 all as directed. |
| 39 | All as item No 38 here in before but on vertical surface as skirting over and incl 10 mm thick rendering in CM 1:3 |
| 40 | Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc. |
| 41 | M & L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring finished even and fair. |
| 42 | Demolition of brick work built in cement mortar or lime mortar complete of any description all as specified and directed. |
| 43 | M&L for Brick work with flyash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 44 | M&L for Brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 45 | M&L for 100 mm thick PCC 1:4:8 Type D-2 using 40mm graded aggregate as in sub base all as specified and directed. |
| 46 | M&L for 75 mm thick PCC 1:3:6 Type C-2 using 20mm graded aggregate as in plinth protection etc, laid to slope of 1:12 and shall be laid in alternate bays n.exc 1.5 m in length, joints 20mm wide will be provided every 1.5m and filled with ceiling compound grade ‘A’ the joints between external wall and plinth protection shall also be laid with ceiling compound grade ’A’, finished cement concrete surface even and smooth all as specified & directed. |
| 47 | M&L for repair and rendering 10mm thick in cm 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed. |
| 48 | M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in sunken floor .average thickness 50mm and making adequate slop towards spout pipe etc complete all as directed at site. |
| 49 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces and finishing the surfaces fair and even without using extra cement in CM (1:4) with WPC (WPC will be measured and paid separately) complete all as directed at site. |
| 50 | M&L for PCC (1:5:10) type E2 using 40mm graded brick aggregate as in sunken portion complete all as directed at site. |
| 51 | S&F 32 mm dia GI spout light grade for sunken portion complete all as directed at site. |
| 52 | M&L for bitumen blown 85/25 applied hot two coats to concrete surfaces at rate of 1.2 Kg/sqm per coat complete all as directed at site. |
| 53 | M&L for polythene film black 200 micron laid in floors etc complete all as directed at site. |
| 54 | M&L for roof treatment over in-accissible roofs in repair by complete removel of existing old treatment and treated with following specifications:(a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab.(b) 15 mm thick cement plaster fair finished using cement mortar (1:4) with WPC (as per manufacturer instruction) on roof slab.(c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plastered surface.(d) Applying modified APP polymeric membrane 3mm thick and minimum weight 3.00 Kg / Sqm for water proofing of roof , sealing as directed at site with 100 mm over laps as per manufacture's instruction.(e) Applying two coat of aluminium paint over bituminous surface of membrane. complete all as specified and directed |
| 55 | Demolition of side wall and top of old RCC water tanks 1000/500 ltrs capacity excluding tank beam and tanks bottom slab after removing existing inlet and outlet connection with all fitting and reparing remaining structure with plastering and making the surface flat and level in CM 1:4 complete all as specified and directed. |
| 56 | Dismantling of existing water tanks and removinging to store and S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed. |
| 57 | S&F in repair for PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed. |
| 58 | Cutting chases in brickwall pinning in making good to facings where required and pointing in cement mortar 1:3 to ends and cutting chases for concealed water tubing and making good cutting n.exc. 10 cm girth. |
| 59 | Taking up or down steel tubing and connection of 15 mm bore complete all as specified directed at site |
| 60 | All as per item No 59 above but for 20 mm bore pipe |
| 61 | S&F steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site for 15 mm bore all as specified. |
| 62 | -Ditto-All as above item No 61 but for 20 mm dia |
| 63 | S&F 15 mm Angle/Stop valves, fancy type chromium plated, or butterfly handle, screwed both ends for iron pipe or for unions and fixed. Complete all as specified and directed. |
| 64 | S&F in repair, 15mm bore bib taps fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 65 | S&F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 66 | S&F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed |
| 67 | S&F in repairs for shower rose chromium plated with or without swivel joints 125 mm dia complete all as specified and directed |
| 68 | S&F in repairs for pillar tap of 15mm dia bore pipe, fancy type cast copper alloy with capstain head chromium plated with or without lettered “hot or cold” with long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified and directed. |
| 69 | S&F in repair vitreous china wash basin, white flat back size 550 x 400 mm including waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waste pipe fitted complete all as specified and directed |
| 70 | S&F in repair Vitreous China urinals, bowl type flat back, size of 465 x 355 x 265 mm (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including 32mm dia waste pipe fitted complete all as specified and directed |
| 71 | S&F for 600x450mm beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden ply with chromium plated brass screws and cup washers. |
| 72 | S&F brass chromium plated tubular towel rail 20 mm dia 'D' type 60 cm long between flanges complete all as specified and directed |
| 73 | S&F in repair for 10ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed. |
| 74 | S&F vitreous china squatting pan ORRISA Pattern of size 580x 440mm white with integral foot rest complete (excluding cistern and flush pipe) with provn of lime concrete including backing joints all as directed at site. |
| 75 | S&F in repairs CP soap dish approximate size 160x160x90mm all as directed |
| 76 | S&F in repairs decorative curtain rod made out of 25mm dia (outer dia) MS pipe having wall thickness 0.63mm, PVC coated of any colour and pattern as approved overall dia 28 to 28mm, includiing and including two nos brackets on each ends alongwith globe on each ends for earch window/door fro fixing complete all as specified and directed with fancy design |
| 77 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site |
| 78 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 79 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 80 | S&F PVC (SWR) bends 110 mm bore of any radius all as specified & directed |
| 81 | S&F PVC (SWR) bends 75 mm bore of any radius all as specified & directed. |
| 82 | S&F PVC (SWR) junction single (singleT) equal or unequal 110mm bore provided with access door all as specified & directed. |
| 83 | S&F PVC (SWR) junction single (singleT) equal or unequal 75mm bore provided with access door all as specified & directed. |
| 84 | S&F 110 mm bore PVC (SWR) vent cowl. |
| 85 | S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement. |
| 86 | S&F 110mm dia PVC (SWR) WC connector with lip ring |
| 87 | S & F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays of 100mm borer of pipe Including bolts and nuts and securing ends of stays to wall or roof |
| 88 | S & F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays of 75mm borer of pipe Including bolts and nuts and securing ends of stays to wall or roof, complete all as specified & directed. |
| 89 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed. |
| 90 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed. |
| 91 | Taking down Old/ Unserviceable MCB DBs SPN/TPN/ Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed. |
| 92 | M&L for point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new modular sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed.Note: The rate quoted is deemed to be included for modular sheet and steel terminal box, for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces. |
| 93 | All as per Ser item No 92 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 94 | All as per Ser item No 92 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 95 | All as per Ser item No 92 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 96 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 97 | S&F Switch modular single pole , one way 16 Amps complete all as specified and directed. |
| 98 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 99 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 100 | S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed. |
| 101 | S&F modular Fan step regulator 230 Volts single phase 120 watt, 2 module complete all as specified and directed. |
| 102 | M&L for submain complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLSH cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length) |
| 103 | Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. |
| 104 | Supply and fix MCCB DB VTPN 4 way with metal door suitable for Provision of incommer and out going MCCBs/MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 105 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed. |
| 106 | S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 107 | S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles. |
| 108 | S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 109 | S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. |
| 110 | S&F in repair exhaust fan steel body AC single phase, 230Volts of size 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. |
| 111 | S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old ceiling fan and deposited to store. complete all as specified and directed. |
| 112 | S&F in replacement of building LED security light fitting 25 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site. |
| 113 | Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed. |
| 114 | Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as directed. |
| 115 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as directed. |
| 116 | Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick |
| 117 | Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement . |
| 118 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed Please Enable Macros to View BoQ information |
| 119 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed Please Enable Macros to View BoQ information |