| 1 | Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 240 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and directed at site by Engr-in-charge.Note:- Excavation and earth work will be measured and paid separately. |
| 2 | Description all as per Srl items No.1 here-in-before but of size 95 sqmm x 3.5 core |
| 3 | Description all as per Srl items No.1 here-in-before but of size 70 sqmm x 3.5 core |
| 4 | Description all as per Srl items No.1 here-in-before but of size 50 sqmm x 3.5 core |
| 5 | Description all as per Srl items No.1 here-in-before but of size 25 sqmm x 4 core |
| 6 | Description all as per Srl items No.1 here-in-before but of size 16 sqmm x 4 core |
| 7 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft soil all as directed.Note - Excavation/earth work shall be done by manually manner with the safety of Data/OFC/telephone cable. If any cable damaged during the excavation to be repair same time and cost to be included in qouted rates, all as specified and directed by engineer-in-charge. |
| 8 | Excavation of Soft soil in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr upto 3 mtr for foundation ect. Or for shafts, well, cesspits, mainholes ect. For foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge |
| 9 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 10 | Supply and laying unreinforced precast cement concrete cable covers, Class LV, Type-1, with peak, size 250 mm x 150 mm x 40 mm in trenches for cable protection complete all as specified and as directed by the Engineer - in -Charge. |
| 11 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 12 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 13 | Taking down/dismantling LT Steel tubular poles and complete all as specified and directed at site by Engr-in-charge. |
| 14 | Supply and fix steel tubular swaged poles type 410 SP-31 (9.0 meter long) Swan Neck Type complete with CI base plate and final and swan neck, (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer,including two coats of black bituminous paint throughout internally and externally upto planting depth and two coats of synthetic enamel paint of alternate White and black strips, 30 cm high over one coat of red oxide primer upto 1.5m height from ground level/coping. The remaining portion shall be painted with two coats of aluminium paint over coat of red oxide primer complete all as specified and directed by Engr-in-charge. Note : Necessary earthwork, PCC shall be measured and paid for separately. |
| 15 | S&F energy saving LED Security light fittings, 90 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gasket and energy efficient LED 5700K and including all accessories etc complete all as specified and as directed.Make:Crompton TRP-412-90-30-SL-NSG or equivalent in Philips/Bajaj/Havells |
| 16 | Providing PCC 1:4:8 type D:2 using 40mm graded crushed stone aggreate as foundation for pole foundation all as specified and directed. |
| 17 | Providing PCC 1:2:4 type B:1 using 20mm graded crushed stone aggreate as in for pole coping all as specified and directed. |
| 18 | Supply and fix in replacement of 80 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc, complete all as specified and directed at site by Engr-in-charge. |
| 19 | Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc,complete all as specified and directed at site by Engr-in-charge. |
| 20 | M&L for trenchless boring 100 mm dia under road crossings/foot paths by manual / Boring machine,complete all as specified and directed at site by Engr-in-charge. |
| 21 | Taking down outdoor type LT Panel with by disconnecting all connections very carefully with necessary switchgear,complete all as specified and directed at site by Engr-in-charge. |
| 22 | Supply, installation testing and commissioning of LT Panel out door type, water and vermin proof CPRI approved protection IP-54 of minimum size 1500mm x 1400mm x 500 mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of ht 600mm from ground level suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories and also including removing old exisisting one complete all as specified and as directed.Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories and CPRI certificate for approval before execution of the work. (a) Copper strip busbar of 500 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB 4P, 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu, 400 Amps with breaking capacity 36 KA- 01 No (Incoming )(c) MCCB 4P 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu,160 Amps with breaking capacity 25 KA-04Nos (outgoing)(d) MCCB 4P 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu, 100 Amps wirh breaking capacity 25 KA-02Nos (outgoing) (e) MCCB 4P 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu, 63 Amps wirh breaking capacity 25 KA-02Nos (outgoing)(f) MCB TPN 63 Amps Outgoing -01 Nos |
| 23 | Supply, fabricating, installation, testing and commissioning of LT Panel out door type, water and vermin proof CPRI approved protection IP-54 of minimum size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of ht 600mm from ground level suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories and also including removing old exisisting one complete all as specified and as directed.Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories and CPRI certificate for approval before execution of the work. (a) Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB 4P, 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu,160 Amps with breaking capacity 25 KA- 01 No (Incoming )(c) MCCB 4P 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu, 100 Amps wirh breaking capacity 25 KA-04Nos (outgoing)(d) MCCB 4P 415 volt adjustable thermal magnetic release type with rotary handle,Ics=100%Icu, 63 Amps wirh breaking capacity 25 KA-04Nos (outgoing)(e) MCB TPN 63 Amps Outgoing -01 Nos |
| 24 | Supply and installation testing and commissioning of LT Panel out door type, water and vermin proof CPRI approved protection IP-54 of minimum size 1400mm x 1000mm x 500 mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories and also including removing old exisisting one complete all as specified and as directed.Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories and CPRI certificate for approval before execution of the work. (a) Copper strip busbar of 200 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB 4P, 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu, 160 Amps with breaking capacity 25 KA- 01 No (Incoming )(c) MCCB 4P 415 volt adjustable thermal magnetic release type with rotary handle, Ics=100%Icu, 63 Amps wirh breaking capacity 25 KA-06Nos (outgoing)(d) MCB TPN 63 Amps Outgoing -01 Nos |
| 25 | Supply and installation outdoor type loop in loop out junction box totally enclosed double door weather and vermin proof, suitably ventilated, 440 Volts, 50 HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel and powder coating including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including 4 Nos copper bus bar of 200 Amps with indicating lamps of R,Y,B and MCCB 4P, 415 volt adjustable type, 100 Amps with breaking capacity 25 KA- 01 No at incoming side complete all as directed and specified by Engr-in-charge. |
| 26 | Supplying & fixing in replacement of terminal panel box of outdoor pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system. The Board/Panel shall be made out of moduler THERMOPLASTIC ENCLOSURES. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. The manufacturer of board/panel shall submit a copy of test report in accordance with IEC 60529. The Panel Should be assembled at manufactures factory of THERMOPLASTIC ENCLOSURES.and Panel box having 1x 6 Amp MCB (Make -Indo Asian(optipro /Havells/Legrand), 16 Sq.mm Terminal Block (04 Nos) , 6 Sq.mm Disconnected Terminal (01 No) ,4 Sq.mm Earth Terminal (01 No) including MS clamp flat 20 mm x3 mm in suitable fixed to pole with nut bolts and PVC gland in suitable for 6 to 16 Sq mm cable complete all specified. |
| 27 | Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FRLS cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through steel conduit for street light pole including connection from junction box to street light fittings qincl fixing of existing old street light fitting complete all as specified and directed. Please Enable Macros to View BoQ information |
| 28 | Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FRLS cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through steel conduit for street light pole including connection from junction box to street light fittings qincl fixing of existing old street light fitting complete all as specified and directed. Please Enable Macros to View BoQ information |