| 1 | Annual Maintenance Contract |
| 2 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 3 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 4 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 5 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 6 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 7 | OD177235/2024-2025:Supply and providing 20W, 1200mm LED Tube in the existing box type fittings after providing necessary alterations in the wiring of the fittings and make it good working conditions. |
| 8 | OD177234/2024-2025:Supply and providing the following types and power rated lamps in the existing fittings as required 9W B22 - 105Lumen/watt LED bulb as required. |
| 9 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 10 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 11 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 12 | OD177237/2024-2025:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C- |
| 13 | OD177231/2024-2025:Supply, installation, testing and commissioning of 3 Ltr, 3KW instant water heater and giving connections as required. (Make: V- Guard/ Racold etc.. ) |
| 14 | OD177240/2024-2025:SITC of 1500 lumen round/square recessed fittings made of diecast aluminium having efficiency less than 1101/w pf greater than 0.95, THD less than or equal to 10% chip make cree /Osram/ Lumilled/ Nichea pre-wired light fitting of all type complete with all accessories and fluorescent lamp suspended from ceiling using 2 Nos steel chain (16 SWG or nearest available size of lenght not exceeding 30cm properly hooked to steel hook anchored to the ceiling and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to the relevant ISS or extending the original wiring and giving connection etc as required. |
| 15 | OD177626/2024-2025:SITC of 3600 lumen square (2ftx2ft) recessed fittings made of diecast aluminium having efficiency less than 1101/w pf greater than 0.95, THD less than or equal to 10% chip make cree /Osram/ Lumilled/ Nichea pre-wired light fitting of all type complete with all accessories and fluorescent lamp suspended from ceiling using 4 Nos steel chain (16 SWG or nearest available size of length not exceeding 30cm properly hooked to steel hook anchored to the ceiling and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to the relevant ISS or extending the original wiring and giving connection etc as required.( for fitting in false ceiling ) |
| 16 | OD177232/2024-2025:Supply Conveyance and installation of Wall mounting Light fixture with poly carbonate body suitable for 1X9 watts LED Lamps fixing directly on wall and giving connections as required. (Havells make (Sl.No: LHDL06160099) or equivalent) -- |
| 17 | OD177238/2024-2025:Supply and replace the existing defective heating coil of existing 10 ltr capacity storage geyser with new one and make it suitable in good working condition ( 2000W/230V) |
| 18 | OD177230/2024-2025:Supply and replace the defective thermostat with new copper thermostat suitable for 10 to 30 Liter storage type water heater (16 A, 230 V AC with re set button- 20A 230V AC), cut out, compatible with v guard, racold, crompton,orient, kenstar...etc geyser thermostat.- |
| 19 | OD177233/2024-2025:SITC of 700lm pressure die cast housing Bulk head with IP65 protection and IK 08 having efficiency not less than 105lumen/watt and giving connection with 3 core flux wire as required. ( Philips make WT140W LED7S CW PSU S1 PC or equivalent Make) - |
| 20 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 21 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 22 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 23 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 24 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 25 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 26 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 27 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 28 | 1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 29 | 1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 30 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 31 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 32 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 33 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 34 | OD177241/2024-2025:Supply and filling high speed Diesel for generator |
| 35 | OD177236/2024-2025:Charges for supplying Oil Filter, Fuel filter, Fuel Strainer, Engine Oil, and Top up Coolent etc: for Existing 62.5 KVA Diesel Generator set, check all parts of the DG set and make it good working Condition. ( Servicing charges not included). |
| 36 | OD177286/2024-2025:Supply and providing LED drive for 8 to 12W recess mount jaguar make LED fittings Please Enable Macros to View BoQ information |