| 1 | M&L Surface dressing n exc 15 cm deep in hard /dense soil all as specified and directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in hard dense soil all as specified and directed. |
| 3 | Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, and getting out in in soft/loose soil all as specified and directed. |
| 4 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections, plates) including distance pieces, cleats etc.conforming to Fe.290.Gde-E-165 all as specified and directed. |
| 5 | M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe.290.Gde-E-165 all as specified and directed. |
| 6 | S&F Mild steel screw bolts of 11 to 15mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 10cm long but n exc 15cm long all as specified and directed. |
| 7 | M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:3:6) 20mm gde aggregate and setting in CM 1:6 complete all as specified and as directed. |
| 8 | M&L for Rendering10 mm thk in cm 1:6 on Brick / Concrete surfaces as in walls finished rough surface to receive the wall tiles without using extra cement including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 9 | M&L for Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over incl. 10 mm thick backing coat in CM 1:3 to maintaine true plumb removing rubbish off the MOD land complete all as speicified and directed. |
| 10 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10mm thick screed bed in CM 1:4, removing rubbish off the MOD land complete all as speicified and directed. complete all as speicified and directed. |
| 11 | M&L for 15mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. all as specified and directed. |
| 12 | S&F Pillar taps of fancy type high pressure screwed for 15mm dia iron pipe and fixed.(Minimum weight15mm-120gms all as specified and directed. |
| 13 | S&F 15mm dia Bib taps fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed. |
| 14 | S&F Stop valves 15mm bore fancy type chrmium plated cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed. |
| 15 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe all as specified and directed. |
| 16 | S&F PVC valveless, action type, flushing cistern, 10 ltrs capacity low level, white, with inlet, ball valve, float and handle including brackets all as specified and directed. |
| 17 | S&F toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. |
| 18 | S&F Vitreous China urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and directed. |
| 19 | S&F Vitreous China wash basin, white, flat back, size 630x450mm ) excluding taps, waste, chain and plug and porcelain stopper but including brackets all as specified and directed. |
| 20 | S&F PVC connections 15mm size with PTMT nuts of length 600mm all as specified and directed. |
| 21 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) all as specified and directed. |
| 22 | S&F looking mirror 600x450x5mm thick with aluminium channel frame, selected quality mounted on 6mm thick commercial plywood back and fixed with chromium plated brass screws and cup washers etc. , complete all as speicified and directed. |
| 23 | S&F Tubular towel rail brass chromium plated 20mm dia, D type, 60cm long between flanges all as specified and directed. |
| 24 | S & F chromium plated soap dish fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 25 | S&F 40 mm bore and 75 cm long PVC waste pipe suitable for sink complete all as specified and directed. |
| 26 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in earth of 110 mm dia. complete all as specified and directed |
| 27 | S & F of PVC (SWR) 110mm bends any radius all as specified and directed. |
| 28 | S&F in repairs cast iron Nahani trap with grating 100mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B-1 including removing old traps complete all as specified and as directed. |
| 29 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 30 | S&F 4mm thcik figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and directed. |
| 31 | M&L for 18-20mm thick polished granite (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick screed bed in CM 1:6 in flooring complete all as specified and as directed. |
| 32 | M&L for 18-20mm thick polished granite (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10mm thick rendering in CM 1:6 in wall complete all as specified and as directed. |
| 33 | S& F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 34 | M&L for preparating of new steel surfaces and applying two coats of synthetic enamel paint 1st quality over a coat of red oxide primer on steel surfaces exc.10cm width or girth all as specified and as directed. |
| 35 | M&L for 100mm thick Cement concrete in foundations,filling and mass concrete in PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete all as specified and directed. |
| 36 | M&L for Cement concrete in foundations,filling and mass concrete in PCC (1:3:6) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete all as specified and directed. |
| 37 | M&L for heavy duty endura industrial tiles of size 30cmx30cmx20mm thick in floor, path laid and jointed in cement slurry and pointed in grey cement and pigment over 20 mm thick screed bed in CM (1:6) of tiles complete all as specified and as directed. |
| 38 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed all as specified and directed. |
| 39 | M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including Non metalic rigid PVC conduit ISI marked not less than 25 mm with all fitting & other accessories concealed into wall by Cutting chases for concealed conduit wiring, pinning in and making good to surface where required and and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including MS sheet metal box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for following :- One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 40 | S&F modular switch 1 way 10 A 1 module complete all as specified and as directed. Make: Roma/Vinay/Rider |
| 41 | S&F ceiling rose surface shall comply with IS:371-1979 Bakelite 60x 25 mm two to three terminals plates and of outside diameter not less than 63.5mm complete all as specified and as directed. |
| 42 | S & F for plastic body exhaust fan, AC single phase, 240 V 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and making good the disturbed surfaces and fixing to the window with proper fasetner arrangements and all accessories all as specified and as directed. |
| 43 | S&F in replacement 1x15 watt, 230V surface mounted LED downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency, including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified . Make Luker LCL 15R SLK or equivalent in Havells/ Wipro/ Bajaj |
| 44 | S&F 18/20 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified. |
| 45 | S&F 04 way SPN DB (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 100 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete as reqd at site complete all as specified and as directed.Make - Havells / ABB/L&T/ Schneider. |
| 46 | S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing. |
| 47 | S&F MCB SPN 32 Amps C Curve working on 240 volts, 50 HZ,10 KA all as specified and directed. |
| 48 | Supply,laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of size 10 Sqmm 4 core complete all as specified and as directed. |
| 49 | Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 50 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in the following type of strata complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | (a) Soft/Loose soil |
| 52 | (b) Hard/ Dense soil |
| 53 | Returning, filling in, including spreading,levelling, watering and well ramming in layers not xceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 54 | Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed by the Engineer - in - Charge. |
| 55 | M&L for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore for fixing 50 mm dia pipe in road crossing etc. including the cost of making good the disturbed surface and matching with existing (Chequered tiles/Road/PCC) complete all as specified and directed by Engr-In-Charge. |
| 56 | S&F GI tubing medium grade 50 mm dia ISI marked with all fittings laid in trenches for cable protection complete all as specified and as directed. Please Enable Macros to View BoQ information |