| 1 | Taking down carefully aluminium point wiring with PVC casing capin and conduit (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets as required complete all as specified and directed. |
| 2 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor 1.5 sqmm using colour coding drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia, ISI marked ivory colour with all conduit fittings / fixing incl with modular sunken box of suitable size for the following:- One light/ fan (CF & EF) point controlled by one switch. |
| 3 | All as per item No 2 above but One bell point controlled by one bell push |
| 4 | All as per item No 2 above but One light point controlled by two, two way switches |
| 5 | All as per item No 2 above but One 5 pin socket outlet 6 Amps on independent board controlled by one switch. |
| 6 | All as per item No 2 above but One 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch. |
| 7 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm and earth continuity conductor 2.5 sqmm using colour coding drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories for 3 pin 16 amps socket outlet point controlled by one switch incl with modular sunken box of suitable size complete all as specified and directed. |
| 8 | S&F Switch Modular 6A single pole, one way, 1 module complete |
| 9 | S&F Switch Modular 16A single pole, one way, 1 module complete |
| 10 | S&F Socket, 6A - 2/3 pin combined 2 module complete |
| 11 | S&F Socket 6A/16A - 2/3 pin combined 2 module complete |
| 12 | S&F Modular White cover plate with frame,12 module complete . |
| 13 | S&F Modular White cover plate with frame,8 module complete |
| 14 | S&F Modular White cover plate with frame,4 module complete |
| 15 | S&F Modular White cover plate with frame,3 module complete |
| 16 | S&F Modular White cover plate with frame,2 module complete |
| 17 | S&F Calling bell , AC, 230 Volts, single phase complete |
| 18 | S&F bell push , AC, 230 Volts, 1 module complete |
| 19 | Supply and fix lamp holder, PVC / Polycarbonate type with back plate complete all as specified and directed. |
| 20 | S & F in repairs decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL complete all as specified and directed. |
| 21 | S & F in repairs integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed. |
| 22 | S & F in repairs LED surface mounted batten 20 watt, powder coated die cast/ extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED Driver & electrical circuitary), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 23 | Ditto all as per item No 22 above but 10 watts and system efficacy 105 lm/watt or above |
| 24 | Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified and directed. |
| 25 | Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II for BER procedure complete all as specified and directed. |
| 26 | M & L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable using colour coding drawing into and including concealed rigid non metallic PVC conduit 25 mm dia, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x6 sqmm + 1x6 sqmm earth wire including taking down of old unservicable sub main wiring complete all as specified and directed. Note : (i) Cost of cutting & chasing for concealltion of conduit and making good as existing to distrubed surface shall be deemed inclusive in quoted unit rate. (ii) Three runs of 6sqmm copper conductor and 01 run of PVC conduit shall be measured as one unit. |
| 27 | M & L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable using colour coding drawing into and including concealed rigid non metallic PVC conduit 20 mm dia, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x4 sqmm + 1x4 sqmm earth wire including taking down of old unservicable sub main wiring complete all as specified and directed. Note : (i) Cost of cutting & chasing for concealltion of conduit and making good as existing to distrubed surface shall be deemed inclusive in quoted unit rate. (ii) Three runs of 4 sqmm copper conductor and 01 run of PVC conduit shall be measured as one unit. |
| 28 | S & F in repairs 20 amp, single pole and neutral socket outlet, with 2 poleand earth, metal enclosed plug top in powder coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and incl one number single pole 'C' series MCB 16 amp as required complete all as specified and directed. |
| 29 | S & F in repairs MCB distribution board , SPN 240 volts, 8 ways powder coated , CRCA steel sheet degree of protection IP 43 -IK 09 with double door, recessed mounted having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plate, in unused spaces as required complete all as specified and directed. Note : DB and MCB incorporated in DB shall be of same make / brand. |
| 30 | S & F in repairs MCB distribution board VTPN , 4 way, powder coated CRCA steel sheet suitable for MCCB incomer 125 Amp , 4 way 415 volt degree of protection IP 43 -Ik-09 with double door, recessed mounted having 250 amp insulated tinned copper bus bar , neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plate, in unused spaces wherever required comprising of the following:- Incoming:- one number MCCB, 125 Amp, 04 pole, AC, 415 Volt, 50 Hz 16 KA ( Icu=Ics), thermally adjustable between 70 % to 100 %. Outcoming:- Twelve numbers MCB, SP, AC, 240 volt, 50 Hz, 10 KA, 32 A, 'C' series ISI marked. Note : Cost of above mentioned MCCB and MCBs shall be inclusive in quoted unit rate. |
| 31 | S & F in repairs MCB, SP, AC, 240 volt of 06 to 32 Amp capacity \\"C\\" Series, ISI marked, incl making connections by using suitable copper lugs as required complete all as specified and directed. |
| 32 | S & F in repairs MCB, DP, AC, 240 volt of 32 Amp capacity \\"C\\" series, ISI marked, incl making connections by using suitable copper lugs as required complete all as specified and directed. |
| 33 | Material and labour for earthing in replacement complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete. |
| 34 | Supply and fixing ceiling fans 1200 mm sweep, BEE star rated 5 with brush less direct current (BLDC) motor, class of insulation B, 3 Nos blades, up to 90 cm long down rod, canopies, shackels, kit, safty rope, copper winding, power factor not less then 0.9 service value ( CM/M/W) min 6.00, air delivery min 210 cum/min, 350 RPM ( tolerance as per IS: 374- 2019) THD less then 10 % remote unit for speed control and all remaining accessories incl safty pin, nut bolts, washers , tempr rise 75 degree C (max) , insulation resistance more then 2 mega ohm, suitable for 230 V, 50 Hz complete all as specified and directed. |
| 35 | S&F of exhaust fan single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible cable from ceiling rose to exhaust fan incl cutting suitable of exhaust fan as required. |
| 36 | S&F Fresh air fan of size 200 mm sweep PVC body complete with louvers connection up incl suitable size three core flexiable copper cable from ceiling rose to Fresh air fan as required incl cutting suitable of exhaust fan complete. |
| 37 | Supply and fix in repairs 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75000 buring Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as perIEC 61000-4-5 complete all as specified and directed. |
| 38 | Taking down electric meter and refixing on same board after rewiring all as specified and directed. |
| 39 | Supply and fix in replacement 15 watt rechargeable bulb with min 2 hrs backup , 230v, 50 Hz complete. |
| 40 | M&L for applying two coats of oil bound distemper over a coat of primer on walls with 1 mm thick putty after complete removal of existing treatment complete. |
| 41 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete. |
| 42 | Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete . |
| 43 | M & L Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete. |
| 44 | M & L Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete. |
| 45 | Supplying and laying of fixing DWC HDPE pipe alongwith all accessories like socket, bend, couplers etc. ISI marked as per IS-16205 ( part-24) incl cutting/ jointing cutting/ jointing laid in tranches ( excavation not incl) wall floor etc. as required 50mm outer dia and 38 mm inner dia 38 mm ( for cable protection) complete all as specified and directed. Please Enable Macros to View BoQ information |