| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 5 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing all as specified. |
| 6 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 7 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 8 | Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 9 | Dismantling wooden boarding (eaves board, purlin, rafter etc) of any description fixed in any position with nails complete all as specified and as directed |
| 10 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed. |
| 11 | Dismantling asbestos cement/PVC pipe 50/75/100 mm dia including clamps complete all as specified and directed. |
| 12 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 13 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 14 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 15 | Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 16 | Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 17 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft / lose soil complete all as specified |
| 18 | M&L for Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 19 | M & L sand filling under floors or in foundation , base for precast concrete interlocking paver block including watering levelling and consolidation complete all as specified . |
| 20 | M & L for Plain Cement Concrete (1:3:6) type C1 using 20mm graded stone aggregate as in surface channel and drain all as specified and directed. |
| 21 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends for etc complete all as specified and directed. |
| 22 | Add or deduct for each 25 mm girth or part thereof over or under 30cm (For adjustment in girth of item mention above) |
| 23 | M & L for 75mm thick cement concrete 1:3:6 type C-2 (using 20mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid in panels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 24 | M & L for plain cement concrete 1:2:4 type B1 using 20mm graded aggreagate as in coping , benching incl necessary formwork complete all as specified and directed. |
| 25 | M & L for 150mm thick Plain Cement Concrete (1:2:4) type B2 using 40mm graded stone aggregate for base in floor complete all as specified and directed. |
| 26 | M & L Providing and laying 80mm thickness factory made precast concrete interlocking paver block of M-40 grade any size and shape confirming to IS 15658-2006 with approved colour, design & pattern as in hardstanding, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified & as directed.Note : Item of Sand filling will be paid seperatly in relevant item. |
| 27 | M & L for 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 28 | M & L for 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 29 | M & L for Mild Steel TMT Bar 5mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 30 | M & L for brickwork with subclass 'B' or locally available best quality old size bricks, straight or curved on plan exc 6 m mean raduis, built in CM (1:6) complete all as specified and directed. |
| 31 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 32 | M & L 10mm thick rendering in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified. |
| 33 | M & L for 10 mm thick rendering in cement mortar (1:6) on other side of lathing surface finished fair and even complete all as specified. |
| 34 | M & L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on one side of lathing in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified. (Note :WPC measured separately). |
| 35 | M & L for Rendering/plastering, 15 mm thick (10mm+5mm) in two layers in cement mortar (1:4) on any face of brick walls or concrete surfaces, using WPC, surfaces finished finished even and smooth without using extra cement complete all as specified. (Note :WPC measured separately). |
| 36 | Supply only integral water proofing compound WPC complete all as specified. |
| 37 | M & L Non Skid ceramic tiles coloured 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified |
| 38 | M & L Non skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed or bedding layers in cement mortar 1:6 complete all as specified and directed. |
| 39 | M & L Non skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm as in skirting including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed. |
| 40 | M & L Glazed ceramic coloured tiles in vertical surface size 350 x 250 x 7mm/450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed. |
| 41 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 42 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 43 | S & F of mild steel rolled sections (Fe-290, Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and other misc brackets, fixed with angle cleats for fixing of eaves board or other connecting plates complete all as specified. |
| 44 | S&F for GI wire netting 0.71 mm dia and 12 mm mesh lathing to wood or metal studding joints etc in walls ceiling stanchion, beams etc included all laps cutting and wastes complete all as specified and directed. |
| 45 | M & L for second class harwood in scantlings wrought timber framed and fixed in position complete all as specified and directed. |
| 46 | S &F Powder coated aluminium (mirtimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with requiredEPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 47 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for Door shutters with frame, Three track sliding windows ( 2 x glazed & 1 x Gauzed shutter), ventilator & cup board including necessary jointing cleats, screws etc & fixed complete all as specified & directed. |
| 48 | S&F 18/19mm thick MDF boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on both face fixed with screws to Aluminium frame work complete all as specified and directed. |
| 49 | S&F 12mm thick prelaminated MDF boards, exterior grade, prelaminated on both side with decorative choice lamination & other side balencing white lamination complete all as specified and directed. |
| 50 | Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 51 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified. |
| 52 | S & F 8.0mm thick glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes, fixing of glazing clips required all as specified and directed by Engr-In- Charge. |
| 53 | Supply and fix Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 54 | S&F 4.00 mm thick tinted glass ordinary quality and glazing with oil putting square n.exc 0.5 sqm in each pane complete all as specified. |
| 55 | S&F 4.80 mm thick tinted glass ordinary quality and glazing with oil putting square exc 0.5 sqm in each pane complete all as specified. |
| 56 | Supply and fix stainless steel butt hinge 100 mm long size medium weight cold rolled fixed with steel screw or welded to steel frame where required complete all as specified & directed. |
| 57 | Supply and fix Rubber beading for securing glass of suitable size complete all as specified. |
| 58 | Supply and fix Door brush in vertical style for air insulation complete all as specified. |
| 59 | S&F PVC roller in Aluminium body of suitable size for sliding shutters complete all as specified. |
| 60 | S&F side locks of Aluminium body, suitable size for sliding shutters complete all as specified. |
| 61 | S&F Mortice lock, vertical type size 100mm, of brass 04 levers vertical type complete all as specified. |
| 62 | Supply and fix 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified. |
| 63 | Supply and fix Aluminium anodised, 200mm barrel tower bolts of extruded section and fixed complete all as specified. |
| 64 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified and directed. |
| 65 | S&F as in repairs 25 mm dia and 1mm thick MS chromium plated curtain rods with fixing side fancy type brackets end knobs & steel screws etc all as specified and directed . |
| 66 | S&F Door closer hydraulically regulated, designation No 1 universal type, aluminium (extruded body) suitable for door shutters upto 700mm in width and weight n. exc 35 kg, fixed complete all as specified and directed. |
| 67 | Supply and fix in repair Vitreous China urinals, bowl type urinal flat back large size of 465mm x 355mm x 265mm white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 68 | S&F as in repair vitreous china wash basin, white, counter top, size 560 mm x 461 mm ovel shape including waste coupling but excluding taps, waste chain and plug and porcelain stopper complete all as specified and directed.Make: Hindware Cat Part No 10017 or equivalent as per make approved list. |
| 69 | Supply and fix as in repair vitreous china Squatting pan, 'Orissa' pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl necessary lime concrete and 100 mm bore cast iron 'P' trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints complete all as specified & as directed . |
| 70 | Supply & Fixed as in repairs Vitreous china wash down water closet pan ( pedestal pattern ) , white with P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 71 | S & F in repairs PVC valveless,syphonic action type,low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified. |
| 72 | Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 73 | S & F as in repairs 15mm bore pillar tap cast copper alloy with capstan head,chromium plated concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed. |
| 74 | S&F as in repairs 15mm bore bib taps fancy type, long neck, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed. |
| 75 | Supply and fix in repairs 15mm bore stop valves/angle valve of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) fixed complete all as specified. |
| 76 | Supply and fix Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 77 | Supply and fix 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass as in repair complete all as specified. |
| 78 | S&F of Corner /glass shelf complete all as specified and directed. |
| 79 | S&F as in repair swivel mirror 6.0mm thickness complete all as specified and directed. |
| 80 | Supply and fix 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 81 | Supply and fix 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified. |
| 82 | Supply and fix 110mm dia PVC (SWR) bend suitable for pipe complete all as specified. |
| 83 | Supply and fix 75mm bore PVC (SWR) bends any radius, fitted with oval access door complete all as specified. |
| 84 | Supply and fix 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified. |
| 85 | M & L PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified. |
| 86 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 87 | S&F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 88 | Refixing of 15mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.Note: Old serviceable GI tube obtained from relevant taking down items mentioned above shall be used. |
| 89 | Refixing of 20mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.Note: Old serviceable GI tube obtained from relevant taking down items mentioned above shall be used. |
| 90 | Cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified. |
| 91 | Supply and fix as in repair 20 mm bore dia, Gun-metal, gate valves, with iron wheel head, screwed both ends on GI pipes with GI union fixed in existing/ new location including removing old unserviceable ones complete all as specified and directed. |
| 92 | M & L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement designer Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid all as specified and directed. Make:Everest Industries Ltd or equivalent as per IS 14862. |
| 93 | M & L for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of white wash complete all as specified and directed. |
| 94 | M & L for preparation of new or previously untreated ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 95 | M & L preparation of new plastered surface of walls and applying wall care putty of 1 mm thickness over prepare plastered surface with the surface even and smooth complete all as specified. |
| 96 | M & L preparation of new plastered surface of walls and applying two coat of oil emulsion distemper over one coat of primer with using roller complete all as specified. |
| 97 | M & L for complete removal of existing treatment on wall surface and applying two coat of oil bound distemper (white or tinted ) over a coat of primer complete all as specified and directed. |
| 98 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using roller complete all as specified and directed. |
| 99 | M & L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 100 | M & L preparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 101 | M & L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 102 | M & L for preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint complete all as specified and as directed. |
| 103 | E & M Division items |
| 104 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 105 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 106 | Taking out old U/s XLPE cable of any size/type taking out of olf bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 107 | Taking out old U/s GI PIPE of 25/32mm size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 108 | Dismantling of U/s GI pipe of size 40 mm bore complete all as specified and directed. |
| 109 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 110 | Taking out old unserviceable light fittings any type complete all as specified and as directed. |
| 111 | Taking out old existing earthing set complete all as specified and as directed. |
| 112 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 113 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 114 | M & L for point wiring with FRLS stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 115 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 116 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 117 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 118 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 119 | M & L for point wiring with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 120 | M & L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 121 | S&F switch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 122 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 123 | S&F switch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 124 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 125 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 126 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 127 | M & L for submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC casing caping Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed.Note: Two run of single core cable, one run earth wire and one run PVC Casing caping will be measured as one length. |
| 128 | M & L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC casing caping with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Casing caping will be measured as one length. |
| 129 | M & L for submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed.Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 130 | M & L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 2.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 131 | M & L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 132 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 133 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 134 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 135 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 136 | S&F plastic body exhaust fan 300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 137 | S&F bldg security light, LED luminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. |
| 138 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 139 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 140 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 141 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 142 | S&F MCB TPN of capacity 63 Amps, 240 V, 10 KA 'B' curve complete all as specified and directed. |
| 143 | S&F MCB SPN of capacity 40-63 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 144 | S&F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 145 | M & L for new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 146 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 147 | Material & labour GI tube light grade 40 mm bore for protection of cable complete all as specified and directed. |
| 148 | M & L for steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 149 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 150 | M & L 100mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 151 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 152 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 153 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 154 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 155 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. |
| 156 | M & L for cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail