| 1 | Taking out existing unserviceable water roof treatment membrane of any description from RCC roof slab, parapet etc complete all as specified and directed . |
| 2 | M&L PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course to roof surfaces finished even and fair including demoliation of existing unserviceable PCC padding complete all as specified and directed . |
| 3 | M&L Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried and applying cement slurry @ 3Kg/Sqm over RCC slab complete all as specified and directed . |
| 4 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, complete all as specified and directed:-(i) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(ii) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm. Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iii) Two coats of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/ rubbish from the site complete all as specified and directed. |
| 6 | M&L Glazed ceramic coloured tiles in vertical surfaces 450x 350x 7 mm thick set and jointed in cementitious tile adhesive & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 7 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed. |
| 8 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed. |
| 9 | M&L Granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in flooring including 20 mm thick Screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 10 | S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with inlet ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 11 | S&F in repair Vitreous China wash down water closet pan, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 12 | S&F in repair, Vitreous China squatting pan \\"Orissa\\" pattern size 630x450mm white with integral foot rest , including S or P traps (Excluding flushing cistern & flush pipe), laid over and including 150mm thick cement concrete (1:5:10) type E2 using (40mm graded aggregate) complete all as specified and directed. |
| 13 | S&F in repair, vitreous China wash basin, white, flat back, size 550x400mm including brackets cutting for and pinning in ends of brackets or erecting stand, and 32 mm bore Waste coupling of PTMT (half or full hreaded) .(Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 14 | S&F in repair, PVC connection 15mm size with PTMT nuts, 450mm long complete all as specified and as directed. |
| 15 | S&F in repair, Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 16 | S&F in repair, 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 17 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 18 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 19 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 20 | S&F 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 21 | S&F 110mm bore PVC (SWR) junction single,(Single T) equal or unequal of any radius, with access door complete all as specified and as directed. |
| 22 | S&F 110mm bore PVC (SWR) Cowl complete all as specified and as directed. |
| 23 | S&F 50mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed. |
| 24 | M&L in repair, PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all as specified and as directed |
| 25 | M&L in repair, 75mm dia of outlet, PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and as directed. |
| 26 | S&F in repair, 32mm Waste fittings, brass,chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 27 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, including taking out old unserviceable 15mm bore GI pipe complete all as specified and as directed. |
| 28 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors including taking out old unserviceable 20mm bore GI pipe complete all as specified and as directed. |
| 29 | Supplying and laying of 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors including taking out old unserviceable 25mm bore GI pipe complete all as specified and as directed. |
| 30 | S&F in repairs 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type), screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. |
| 31 | S&F in repair 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 32 | S&F in repair, two way, 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 33 | S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 34 | S&F in repair, health faucet suitable for 15mm dia pipe, 1.25 meter long easy flexible tube in chrome finish & wall hook all as specified and as directed |
| 35 | S&F in repair, 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 36 | Taking down Chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames)complete all as specified and as directed. |
| 37 | S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 38 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised paneldesign with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, & fixing in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 39 | S&F 75mm MS butt hinges medium weight, complete all as specified and directed. |
| 40 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 41 | S&F 100 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 42 | Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as directed |
| 43 | M&L 15mm thick plaster of cement mortar (1:3) rendering on brick work or concrete surfaces of sunken slab mixed with and including water proofing compound as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. |
| 44 | M&L applying two coats of PU based liquid single component elastomeric water proofing menbrane on sunken slab complete all as specified and as directed. |
| 45 | M&L PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and as directed. |
| 46 | S&F Powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directedNote:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 47 | S&F anodised aluminium three track sliding window,side/top/shutters (weight of section not less that 0.55 Kg/RM) aluminium section without sash bar aluminium section including all necessary joining cleats,hold fast, rubber gasket anodised snap beading, anodised aluminium fittings, suitable aluminum handle and locking arrangement etc, two track for glass shutter,one track for wire mesh shutter including powder coated of any colour (thick of power coating not less than 50 micron) complete all as specified and directed.. Note:- (i) Wire cloth /glass shall be measured and paid separately under appropiate items. (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed (iii) Fixing of shutters with fittings shall be as per manufacturers instructions. |
| 48 | S&F Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and directedNote:- (i) Glass/Wire Guage shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed (iii) Fixing of shutters with fittings shall be as per manufacturers instructions. |
| 49 | S&F 4mm thick plain sheet glass, ordinary quality fixed with Aluminum frame work exc 0.5 sqm in each pane complete all as specified and as directed. |
| 50 | S&F 4mm thick frosted on one side glass, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 51 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Aluminum frame work complete all as specified and directed. |
| 52 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 53 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 54 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 55 | M&L preparation of surfaces, applying two coats of damp proof paint in wall, ceiling surfaces complete all as manufactures instruction and as directed. |
| 56 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the site complete all as specified and as directed. |
| 57 | M&L rendering 20mm thick with cement mortar 1:4 on fair faces of brick work in two layers (10mm and 10mm) seperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 58 | M&L Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed. |
| 59 | M&L rendering 5 mm thick on ceiling or concrete Surfaces in cement mortar 1:3 finished even and smooth. (without using extra cement), complete all as specified and directed. |
| 60 | Supply only intergral water proofing compound complete all as specified and directed. |
| 61 | M&L preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of primer complete all as specified and directed. |
| 62 | M&L complete removal of existing old finishes of wall, preparation of old wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of primer complete all as specified and directed. |
| 63 | M&L preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 64 | M&L preperation of new plastered surfaces of Ceilings and applying three coats of white wash,complete all as specified and as directed |
| 65 | M&L preperation of old plastered surfaces of wall and applying one coats of white wash,complete all as specified and as directed |
| 66 | M&L preperation of old plastered surfaces of Ceilings and applying one coats of white wash,complete all as specified and as directed |
| 67 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as directed. |
| 68 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 69 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 70 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. complete all as specified and directed. |
| 71 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 72 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 73 | M&L PCC (1:2:4) type-B2 with using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. Please Enable Macros to View BoQ information |