|
| 1 | M & L surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil and disposal complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 3 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 4 | Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable etc. n exc 10sq m on plan & getting out in soft/loose soil complete all as specified and directed. |
| 5 | Demolition of Concrete in ground floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 7 | M&L for hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed. |
| 8 | M&L100mm thick PCC type B-2, (1:2:4) using 40mm graded stone aggregate Finished even & smooth without using extra cement complete all as specified and directed. |
| 9 | M&L 40mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100mm thickness, M-50 Grade fixed with grey cement and pigment laid over and including 50 mm thick sand complete all as specified and directed. |
| 11 | Material and labour RCC(Nominal Mix) Type B1 (1:2:4) (20mm graded aggregate) for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. |
| 12 | Material and labour RCC(Nominal Mix) Type B-1 (1:2:4) (20 mm graded aggregate) for Columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 13 | Use & waste of Form work to sides of pillars, posts, struts, piers,columns and stanchions,square, rectangular,with rough finished surface complete all as specified and directed. |
| 14 | Use and waste of Formwork to sides of beam and soffit of beams, lintels, cantilevers with rough finished flat surface complete all as specified and directed. |
| 15 | Material and labour for mild steel TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | Material and labour for mild steel TMT Mild steel bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | S&F galvanized iron GI square, rectangular or round pipe as in trusses, rafter, purlin, vertical pole and GI flat iron wind ties, plates (plain or chequered), channels, square cut or notched including special shaped washer etc as in framed work conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed. |
| 18 | S&F for GI plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410- W(Gde- E-250) quality-B complete all as specified and directed. |
| 19 | S&F GI flat iron fillets as in wind ties for roof including securing bolts post struits in fencing including cutting top to shape as directed drilling holes notching for wire etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling bolting riveting etc and similar work confirming to FE-290 Gde E-165 complete all as specified and directed. |
| 20 | S&F Mild steel screw bolts 11 to 15 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 21 | Material and labour for brickwork with modular flyash bricks , straight or curved on plan exc 6m mean radius, built in CM 1:6 including demolition of old brick work but in CM complete all as specified and directed. |
| 22 | Material and labour 15 mm thick rendering in cement mortar (1:4) using water proofing compound @ 3 % by weight of cement in finish coat on other than fair faces of brick wall suerfaces, finished even and smooth without using extra cement complete all as specified and directed. Note:- water proofing compound shall be measured and paid separately. |
| 23 | Material & Labour for new surfaces of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 24 | Supply only integral water proofing compound for plastering / concrete work, complete all as specified and directed. |
| 25 | M&L for applying three coats of white wash on new plastered surface of wall including preparation complete all as specified and directed. |
| 26 | M&L Plain cement concrete in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed type B1 (1:2:4) using 20 mm graded aggregate complete all as specified and directed. Note Reinforcmnet will be measured and paid separately ) |
| 27 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 28 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 29 | M&L for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 30 | M&L for 75mm thick PCC 1:3:6 type C2 in plinth protection including bituminus filler at expansion joint finishing even and smooth without using extra cement complete all as specified and directed. |
| 31 | M&L Reinforced Concrete pipe class NP2 450mm diameter laid and jointed complete with collars complete all as specified and directed. |
| 32 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in concrete bed to drain pipes of 450mm dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 33 | M&L for FRP drain cover of size 600 mm X 600 mm suitable to 5 tonne bearing capacity including frame easy to instal long life long lasting corosion free and reduce maintanance cost complete all as specified and directed. |
| 34 | M&L PCC for Cement concrete in surface channels and drains in Type B2 (1:2:4) using 40 mm graded aggregate complete all as specified and directed. |
| 35 | Material and labour 5 mm thick rendering in cement mortar (1:4) using water proofing compound @ 3 % by weight of cement in finish coat on other than fair faces of brick wall suerfaces, finished even and smooth without using extra cement complete all as specified and directed. Note:- water proofing compound shall be measured and paid separately. |
| 36 | Use & waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. |
| 37 | M&L for FRP trench drain cover having size 450 mm X 450 mm suitable to 5 tonne bearing capacity including frame easy to instal long life long lasting corosion free and reduce maintanance cost complete all as specified and directed. |
| 38 | M&L for Reinforced concrete pipes, 150MM class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 39 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in concrete bed to drain pipes of 150mm dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 40 | Supply and fixing 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 41 | Supply and fixing 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 42 | Supply and fixing 110 mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed. |
| 43 | M&L for Providing precast ce- ment concrete Type B1(1:2:4) 20mm graded aggragate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces , complete all as specified and directed. |
| 44 | S&F Fe 410 -W (GdeE- 250) quality Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 45 | Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed. |
| 46 | Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 47 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 48 | Supply and fixing 1000 ltr Rotational moulded polye- thylene water storage tanks triple layer (cylindrical vertical with closed top) and fixed in position all as specified in SSR Part I including dismantling of old unserviceable PVC tank 1000 litres complete all as specified and directed. |
| 49 | S & F tube 25 mm bore ,medium grade galvanised with all fitting fixed complete to walls and ceiling or laid in floors including taking down old unserviceable GI pipe complete all as specified and directed. |
| 50 | S&F in repair for ball valves 25 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe mimium weight for 210 grams as in repairs complete all as specified and directed. |
| 51 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150 mm dia pipes complete all as specified and directed. |
| 52 | S&F FRP manhole cover of size 900X900 mm with frame suitable to bear 2 Tonne capacity, complete all as specified and directed. |
| 53 | Material and Labour for point wiring complete with multi-stranded copper conductor 1.5 sqmm size PVC FRLSH insulated unsheathed cable 1100 Volt grade, conforming IS 694 & colour code in conduit system of wiring, drawn in and including medium grade PVC conduit not less than 20 mm dia concealed, including cutting chases and making good disturbed surface complete, including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified and directed. |
| 54 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 55 | Supply and fix ceiling rose, surface bakelite,65 x 50mm, three terminals complete all as specified and directed. |
| 56 | S&F Modular White Cover Plate with Frame and metal flush box , 8 Module complete all as specified and directed. |
| 57 | Supply and fixing 1x 20 watt LED indoor box type surface / suspended industrial luminaire with aluminium housing with PC diffuser with LED Tube,Slim integrated design efficiency-125 lumen/watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.( Make/Model No:-CCS-100-20-65-HL2-DP-NWH ( BRIGHT LINEA) of Crompton or equivalent of Bajaj/Phillips/Havells/C&S ) |
| 58 | Supply and fixing Factory made sheet metal enclosure for DBs Double door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified and directed. Make - L&T/standard/Havells. |
| 59 | Supply and fix MCB single pole and neutral, 240 volts, 32 to 40 amps breaking capacity 10KA, ‘C’ Series. etc , complete all as specified and directed. Make : Legrand /Siemens/Schneider |
| 60 | Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed. Make : Legrand or eqvt in Siemens/Scheinder |
| 61 | M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item. |
| 62 | S & F 4 mm dia GI wire to connected building earthing to MCB DB Box complete all as specified and directed |
| 63 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed. |
| 64 | Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete all as specified and directed. Note : Punned thickness will be measured for payment purpose. |
| 65 | M&L for well burnt sub class ‘B’ bricks (using old size brick) laid in trenches above sand cushioning for cable protection complete all as specified and directed. |
| 66 | Supply and fixing LED Bulding security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 67 | Supply & Fixing cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including 4 pole terminals with Suitable busbar and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including with MCB SP 10 Amps, bracing clamp,bolts,nuts & washers complete all as specified and directed. (Make Hensel/ Sintex etc. |
| 68 | Supply and fixing of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr and including two nos. MS Clamp of flat iron size 40x6 mm for PVC conduit Pipe complete with nut, bolt, washers complete all as specified and directed. (Make of GI pipe- Jindal/Prakash/Tata) |
| 69 | Supply, laying and fixing 25 mm dia CPVC pipes SDR 11 with all fittings on wall at any height of building for drain of waste water of AC complete all as specified and directed. Please Enable Macros to View BoQ information |