| 1 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding, laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.5 m |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation |
| 3 | Supply of local hard stone/boulder material delivered and stack within a lead of 150 mm to 225 mm |
| 4 | Carriage of brick bats, boulders stone metal, shingles or similar materials over pucca road Distance carried upto 5 km |
| 5 | Supplying and laying Polythene sheet ( 150gm / Sq.m) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches |
| 6 | Cement Concrete with 30mm down graded shingle excluding shuttering. In ground floor. a) 6:3:1 Proportion |
| 7 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge. |
| 10 | 100 mm thick Autoclave aerated concrete block Work with size 625 mm x 250mm x 100 mm- Grade-I, having drying Shrinkage less than 0.05%conforming to IS: 2185 (Part-3)- 1984 made up of fly ash (conforming to IS:3812-1981, with permissible loss on ignition upto 6%), lime , cement and laidin Cement Mortar (1:6) complete in all respect as per direction &satisfaction of Engineer-in-Charge .a) laid in Cement Mortar (1:6)-In Super Structure, Ground Floor. |
| 11 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).over concrete surface](ii) With 1:4 cement mortar(b) 20 mm thick plaster |
| 12 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).over concrete surface](ii) With 1:4 cement mortar(b) 15 mm thick plaster |
| 13 | Neat cement punning about 1.5 mm thick in wall dado, window,sills floor,drain etc. |
| 14 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (a) Fixed type steel windows as per IS sizes with horizontal glazingbars. |
| 15 | M.S or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I Flats and bars of windows, ralling etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 kg/sq.m and upto 16 kg/sq.m |
| 16 | (A) Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails,Sal : Local |
| 17 | Supplying , fitting and fixing M.S.Clamps for door & window frame made of flat bend bar, end bifurcated with necessary screws etc. by cement concrete 1:2:4 as per direction.(b) 40 mm x 6 mm, 200 mm length |
| 18 | Panel (made of single plank) of door and window shutters to design as directed: In Ground Floor (Payment to be made on area of exposed new work). (In case of non- supply of single plank penal rate of reduction to(iii) 25mm thick panel of 30cm to 45cm width(b) Ordinary Teak Wood. |
| 19 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(iv) 75mm. X 47mm. X 1.70mm. |
| 20 | Anodised aluminium barrel/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws.(iii) 100mm long x 10mm dia. bolt. |
| 21 | Anodised aluminium Aldrop/ Sliding bolt of approved manufactured from extruded section conforming to I.S. 2681/66 fitted and fixed complete.(i) 250 mm 16 mm dia. Bolt |
| 22 | Anodised aluminium 'D' type handle of approved manufactured from extruded section conforming to I.S. 230/72 fitted and fixed complete. a) With continuous plate base (Hexagonal/ Round rod)(v) 125 mm grip x 12 mm dia. Rod |
| 23 | Supplying best indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & 6 m height for external wall) (i) 3 mm thick (weighing 7.4 kg/sq.m) |
| 24 | Priming one coat to timber or plastered surface, with ready mixed primer of approved quality, including smoothening surface by sand papering etc. |
| 25 | Priming one coat to steel or metal surface, with ready mixed primer of approved quality, including smoothening surface by sand papering etc. |
| 26 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 27 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer |
| 28 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer |
| 29 | Applying Decorative cement base paint of approved quality after scraping the surface throughly as necessary on plastered, ruled or concreted surface (Manufacturers' specification to be followed).iii) Two coats. |
| 30 | A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : a) On timber or plaster surfaceWith other than hi-gloss of approved quality-(iv) Two coats (with any shade except white) |
| 31 | A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : b) On steel or metal surfaceWith other than hi-gloss of approved quality-(iv) Two coats (with any shade except white) |
| 32 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1957 & IS: 1161- 1958 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957,haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges,labour insurance charges etc. ii) For trusses spanning above 12.00 m and up to 20 .00 m |
| 33 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yieldstrength of 550 Mpa of trapizoidal profile of approved(i) In Roof:- a) With 0.5 mm thick sheet |
| 34 | Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each way |
| 35 | Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (a) 225 mm. wide gutter |
| 36 | Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat19mmx3mm as necessary,the entire frame will be painted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer-in-Charge |
| 37 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC PIPES (ii) 110 mm. Dia |
| 38 | Supplying fitting and fixing of Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).In ground floor(Toilet) |
| 39 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative |
| 40 | Add 18% GST |
| 41 | Add 1% Cess Please Enable Macros to View BoQ information |