| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | a) Avg. Run 10mtr. |
| 3 | b) Avg. Run 8 mtr. |
| 4 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. a) On Board. |
| 5 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. |
| 6 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. |
| 7 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 8 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 9 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 10 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 11 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required |
| 12 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 13 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 14 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 15 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 16 | 2.5 sq.mm. |
| 17 | 4.0 sq.mm. |
| 18 | 6.0 sq.mm. |
| 19 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 20 | Supply & Fixing 240 V, 2 nos. 6A plug socket with separate 2 nos. 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 21 | Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 22 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 23 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 24 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 25 | Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/ Siemens) |
| 26 | Supplying and fixing 415V, 160A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make- L&T/ Siemens) |
| 27 | Supplying and fixing sheet steel (16SWG) cable end box on 160A TPN SFU/ C/O switch enclosure with nuts bolts etc incl. powder coated painting. |
| 28 | Supply and fixing 415V, 16-32A per way, 8 Way vertical TPN MCBDB with provision for DPX 125 & EIM as incommer and TP MCB as outgoing in suitable enclosure with metal door comprising of the following.a) 160A, 36KA, 4 pole MCCB -- 1 No.b) 63A, 10ka ('C'- Curve) TP MCB --6 Nosc) 32A, 10ka ('C'- Curve) TP MCB --2 Nosc) Cable entry box -- 2 No (Make- Siemens/ Schneider/ Legrand) |
| 29 | Supplying and fixing 415 V, 25-32A per way, 6 wayTPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole MCB type Isolators as incomer and 18 non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 63A FP MCB Type Isolator, 18 no. (16-32A) SPMCB. (Make- Siemens/ Legrand/ Schneider) |
| 30 | Supplying and fixing 250 V, 6-10A per way, (2+10)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 32/40A DP Isolator, 10 no. SPMCB). (Make- Siemens/ Legrand/ Schneider) |
| 31 | Supplying and fixing 250 V, 6-10A per way, (2+4)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 32 DP Isolator, 4 no. SPMCB). (Make-Legrand/ Schneider/ Siemens.) |
| 32 | Supplying and fixing 4way MCB SS enclosure with IP-20/30 protection, powder coated provision for 63A four pole MCB with S & F the same, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Make- Siemens/ Legrand/ Schneider) (for walk-in-cooler) |
| 33 | Supply and Delivery of 240V 50 Hz 48\\" sweep (1200 mm) ceiling fan complete with down rod,Canopy,fork etc. and Fixing the ceiling fan complete with blades, canopy, fork, rubber bush etc. (Make- Orient, New Breeze/ USHA - Striker PWD/ Crompton- High Speed) |
| 34 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 35 | Supply & Delivery of 450 mm Tornado II Stand-P/C Blk Guard fan as per direction of EIC. |
| 36 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 37 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 38 | S& delivery 240V. 50 Hz. 230 mm. Sweep 920 r.p.m. Heavy Duty AC Exhaust Fan (As per EPC make) |
| 39 | S& delivery 240V. 50 Hz. 300 mm. Sweep 1420 r.p.m. Heavy Duty AC Exhaust Fan (As per EPC make) |
| 40 | S& delivery 240V. 50 Hz. 450 mm. Sweep 1420 r.p.m. Heavy Duty AC Exhaust Fan (As per EPC make) |
| 41 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 42 | (i) 23 cm (9\\") |
| 43 | (ii) 30 cm (12\\") |
| 44 | (iii) 45 cm (18\\") |
| 45 | Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 46 | (i) 23 cm (9\\") |
| 47 | (ii) 30 cm (12\\") |
| 48 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. Bolts & nuts (6 mm dia x 62 mm long) |
| 49 | (i) 30 cm (12\\") |
| 50 | (ii) 45 cm (18\\") |
| 51 | Supplying and fixing 4way MCB SS enclosure with IP-20/30 protection, powder coated provision for 250V, 1no Programmable Digital timer switch-24 hrs with minimum switching of 15 minute, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Make- L&T/ ABB/ Siemens) |
| 52 | Supply & Delivery 250 volt. 4 Ft. Long LED tube fittings with LED tube complete with all accessories (Make-Philips or equivalent to wipro/crompton Make). |
| 53 | a) Single Fittings, Make- Philips, cat no.- TMC 502 1xT-LED 22W incl. 1x 18W PC body, 2100lm LED tube/ Crompton/ Bajaj/ Jaquar) |
| 54 | b) Double Fittings, Make- Philips, cat no.- TMC 502 2xT-LED 22W incl. 2x 18W PC body, 2100lm LED tube/ Crompton/ Bajaj/ Jaquar) |
| 55 | Fixing of single LED tube light fitting attached with the wall with 2 No. “V” type MS clamp whose one side inserted within the wall and other side connected with the suitable size of bolts and nuts incl. S&F\\"V” type MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm unsheathed stranded 1.5 sqmm copper wire of 0.5mt. length. incl. 2nos mounting kit. |
| 56 | Fixing of single/double LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm flexible copper wire of 1.10 mt. length. incl. 2nos mounting kit. |
| 57 | S & F of 9Watt Led lamp. (Make- Philips/ Bajaj/ Crompton) |
| 58 | Supplying & Fixing 10W LED bulk head light fitting with all accessories on wall/ceiling. (Make:- Philips, Cat No.- WT202W LED10S CW PSU S3 PC/ Crompton/ wipro) |
| 59 | Supply & Fixing of 250 volt. Ultra sleek recessed downlight for low height false ceiling in round/squre profile complete with all accessories (Philips Make-GreenLED Ultima Round- DN496 LED12S-6500 PSU WH, or equivalent make to Crompton / Wipro). |
| 60 | Supply and fixing of chain light minimum 400lm/ Mtr, 72LED/Mtr. and IP65 rated for store area using (Philips make-Marathon Rope- high-lumen LED rope light) without driver, complete in all respects as per the direction of the Engineer-in-Charge (EIC). (100m length) |
| 61 | Supply and fixing driver for above chain lightIP-65 rated for store area using (Philips make- Marathon Gen 3 accessory ), complete in all respects as per the direction of the Engineer-in-Charge (EIC). |
| 62 | Supply & Fixing of 240v, 50W LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. system efficacy 110 LPW as per direction of EIC. (Make- Crompton, Cat No.- TFS-504-50-57-NL-SL-GL-NSG/ Philips/ wipro) |
| 63 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cum-Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. ( for flood light connection inside store room)(a) 150 mm x 100 mm x 65 mm |
| 64 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. |
| 65 | Supply & Delivery of following size 1.1 kv.gr.XLPE insulated 1100V Grade as per IS 7098 (part 1) 1988 armoured sheathed Aluminium conductor cable. [Make - Polycab /Havells/Gloster / KEI / RR Kabel / MESCAB] |
| 66 | 4 core 25 sqmm (from Panel to HTPN) |
| 67 | 2 core 6.0 sqmm (for compound Light) |
| 68 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 69 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 70 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 71 | 4 core 25 sqmm |
| 72 | 2 core 6.0 sqmm |
| 73 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 74 | 4 core 25 sqmm |
| 75 | 2 core 6.0 sqmm |
| 76 | Supplying & fixing medium gauge GI Pipe (ISI-Medium) rotection with necessary fittings and jointing metarials as required 25 mm dia GI pipe |
| 77 | Supply of 240V timer DB with suitable size sheet steel enclose double door, phosphatised powder coated, neutral bar , din rail with IP-43 protection comprised with 1 no. 20/25A DP MCB (‘C’ Curve, 10KA), 1 no. 24 hours programmable timer switch and 1 no. 25A contactor complete with internal wiring by 1.1kv grade 4 sq mm. FR PVC insulated copper wire incl. 1 no auto manual by pass troggle switch and provision for earthing attachment incl. LED indicating light for running condition with locking arrangement (for controlling individual AC machine) [Make:- L&T /Cabtree/Legrand/ABB] |
| 78 | Supply & Delivery of split type fixed speed, Non-Inverter Air conditioning machine having the following specification :Rated EER: 3.89, Compressor Type: Rotary, Rated Voltage/Phase/frequency - 230V/Single/50hz, Max. Power Input (Watts) : 1295, Min. Cooling Capacity (Watts): 5050, Airflow rate for indoor unit(M3/H.): 1020, PM filter, Eco Cool 4way wide & long airflow, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, auto swing, fan speed option (low/medium/high/turbo) etc. Refrigerant- R32/R410A. Min. BEE Star rating : 3 star, minimum tonnage : 1.5 Ton or Higher[Make- Mitsubishi Electric - MS/MU-AGZ18VF-DA1-KT/ O General] |
| 79 | Installation,Commissioning and testing of 2.0/1.5 ton split type AC machine both indoor/outdoor including fixing of 40 x 40 x 5 mm MS angle iron frame and mending good the damages. |
| 80 | Supply and Fixing ofi) Copper pipe 3/8\\"/1/2\\" for liquid as required.ii) Copper pipe 5/8\\" / 1/4\\"for suction as required.iii) Insulation Foam 3/8\\" / 1/2\\" for liquid as required.iv) 5/8\\" / 1/4\\"for suction as required.v) laying of 3/4 core 2.5 sqmm 1.1kv grade xlpe insulated round flexible copper cable as required. (Make:- Havells/ Gloster/ KEI/ Carrency) |
| 81 | PVC Drain pipe for drainage of water for Split A.C. both indoor unit. |
| 82 | S & F of 32 mm UPVC hard Drain pipe for drainage of water for AC Machine. |
| 83 | Charges for dismantling the existing split AC unit along with all accessories, as per the direction of the Engineer-in-Charge (EIC) |
| 84 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as by ISI-Medium GI pipe or TATA-M GI Pipe |
| 85 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 86 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages No. 4 SWG |
| 87 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS. |
| 88 | Excavation of soil for installation of Earth Electrode and filling & ramming. For morrum soil. |
| 89 | Supply of 240 V timer DB with suitable size sheet steel enclose double door, phosphatised powder coated, neutral bar , din rail with IP-43 protection comprised with 1 no. 20/25A DP MCB (‘C’ Curve, 10KA), 1 no. 24 hours programmable timer switch and 1 no. 25A DP Power contactor complete with internal wiring by 1.1kv grade 4 sq mm. FR PVC insulated copper wire incl. 1 no auto manual by pass troggle switch and provision for earthing attachment incl. LED indicating light for running condition with locking arrangement (for controlling Compound light) [Make:- L&T / Cabtree / ABB / Legrand] |
| 90 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 91 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 92 | Supply & Delivery of 240V, 45W LED road lighting luminaire ( IP 65 or better) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system and system lumen output will be minimum 100 lumen/w suitable for use with 230Volt 50Hz AC supply etc as required. (Philips Model No. BRP331 LED54 CW R5N PC PSU S1 V1 / or equavalent product of Crompton/Wipro having similar specification) |
| 93 | Add GST @ 18% on Item no 1 to 65 |
| 94 | Add CESS @ 1% on Item no 1 to 66 Please Enable Macros to View BoQ information |