| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | (A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(B) Do - by fine sand |
| 3 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 4 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(A) [Pakur Variety](a) 1:3:6 proportion |
| 5 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 6 | In First Floor(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelII. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL & OTHER MANUFACTURERS NOT SPECIFIED |
| 8 | First Floor/upto 4 mII. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL & OTHER MANUFACTURERS NOT SPECIFIED |
| 9 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any,in ground flooras per relevant IS codes.(i) Pakur Variety |
| 10 | In First Floor(i) Pakur Variety |
| 11 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in For First Floor. |
| 12 | Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, First Floor |
| 13 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary In First Floor.(ii) With 1:4 cement mortar(c) 10 mm thick plaster |
| 14 | (i) With 1:6 cement mortar First Floor.(b) 20 mm thick plaster |
| 15 | (c) 15 mm thick plaster First Floor. |
| 16 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour |
| 17 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 18 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 19 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 20 | A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc.including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 21 | (b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 22 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.In In First Floor(b) Two Coats |
| 23 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material,labour,scaffolding and all incidental charges but excluding the cost of primer.In First Floor (Two Coat)a) Normal Acrylic Emulsion |
| 24 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in gFirst floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 25 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, alamoid/ Bitumen/M-Seal etc) complete.UPVC Pipes:110 mm. Dia |
| 26 | A) Bend 87.5 degree, 110 mm. Dia. |
| 27 | B) Tee, 110 mm. Dia. |
| 28 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 29 | Fixing of ceiling fan complete with blades, regulator, canopy, fork, rubber bush etc. including S & fixing 1/1.40 (1.50 sqmm) PVC wire for down rod upto 300 mm including painting the rod with approved paint and making necessary connection as required by 2 X 1.5 sqmm flexible copper wire |
| 30 | Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2mm shank thickness ceilling fan of following make. B)Havells/Crompton make (60W) |
| 31 | supply & fixing socket type fan regulator (step type) (brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. Connections etc.) |
| 32 | Supplying and fixing MS fan clamp of two piece type for R C ceiling as per approved specification, febricated from 40 mm x 9 mm MS flat including making good damagesto building roof with satisfactory finishing and painting. |
| 33 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works (PWD schedulee ) |
| 34 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as requiredg) 2 x 4 sq mm |
| 35 | Distribution of wiring in 2 x 1.5 sq.mm PVC single core standard 'FR' copper wire 1.1 K.V. grade within 19 mm PVC rigid conduit pipe in concealed system with MS switch board, perpex top cover & 5A. Piano type attachments for light, fan points. ( Average run 6 mt) with mending good damages to original finish (Wire make Havells / Finolex) |
| 36 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cum-Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 37 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection.(Legrand/Havells) 6-32A |
| 38 | Supplying and fixing Changeover switch with SheetSteel enclosure on flat iron frame on wall with nutsbolts etc 32 amp 240 V havels/L&T/strandard make |
| 39 | GST 18% =Rs. |
| 40 | Labour Cess 1 % = Rs. Please Enable Macros to View BoQ information |