| 1 | Building Renovation |
| 2 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | OD453498/2025-2026:Excavating trenches of required width for pipes, cables, etc including excavation for sockets,and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out theexcavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth,including consolidating each deposited layer by ramming, watering, etc. and disposing ofsurplus excavated soil as directed, within a lead of 50 m:(Modified 2.10.1.1)All kinds of soil . Pipes, cables etc |
| 4 | OD423388/2025-2026:Providing and fixing pvc pipes including joining of pipes with one step pvc solvent cement and testing of joints complete as per direction of engineer in charge 32 mm dia 10 kg/cm2. Excluding trenching and refilling. |
| 5 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 6 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 7 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 8 | OD453464/2025-2026:Providing and fixing precoated galvanised iron profile sheets(size,shape ,pitch of corrugation as approved by the Engineer in charge 0.35 mm(+0.05%) total coated thickness with Zinc coating 120 gm per sqm as per IS - 277 in 240 mpa steel grade 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 m or as desired by Engineer in charge.The sheet shall be fixed using self drilling /self trapping screws of size(5.5x55 mm) with EPDM seat,complete up to any pitch in horizontal/vertical or curved surface,excluding the cost of purlins,rafters,trusses and including cutting to sizeand shape wherever required. |
| 9 | 50.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall |
| 10 | OD424587/2025-2026:Supplying and erecting precast R C C pipes 60 cm outer diameter and 60 cm long or nearest size for cess pit . |
| 11 | OD424588/2025-2026:Supplying and fixing precast R C C covering slab for cesspit 60 cm or nearest diameter including all |
| 12 | OD453056/2025-2026:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Modified 8.31 |
| 13 | OD453057/2025-2026:Providing and laying semi vitrified floor tiles in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approvedmake, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarsesand), etc, complete.Size of Tile 12000 x 600 mm.(modified 11.41.2)(epoxy pointing to be paidseparately) |
| 14 | 11.50:Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles |
| 15 | 11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 16 | OD423386/2025-2026:Supplying and fixing half split PVC gutter 160 mm size with MS flat of 20 mm X 5 mm size @ 60 cm c/c fixing on roof Members (purlin or rafters) bolts,nuts and washers etc including making necessary connection with rain water pipes complete.., |
| 17 | OD423391/2025-2026:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes |
| 18 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 19 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 20 | 13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 21 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 22 | OD453465/2025-2026:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of 6 mm metal, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver blockof approved color design and pattern.(modified 16.91.2) |
| 23 | 51.2.3:Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade |
| 24 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 25 | OD453524/2025-2026:Supplying and fitting good quality P V C water tap including all Please Enable Macros to View BoQ information |