| 1 | ELECTRIFICATION |
| 2 | OD200366/2025-2026:Supply, conveyance, installation, testing and commissioning of 20KVA/16KW 1 phase D.G. set with company made acoustic canopy confirming to CPCB II norms Engine Make of Engine: Cum mins/ Greaves/ Leyland/ Kirloskar/Mahindra/ESCORTS Type of Engine: Diesel Engine No of cylinders: Suitable to develop the required BHP as per manufactures standards with KSEB SPEC AMF Control Panel/ATS (Automatic Transfer Switch for DG and EB control) Make L&T, Socomec, Elmeasure Method of cooling: Water cooling (with radiator) Aspiration: Naturally aspirated Design: Suitable for generator set application Out put: BHP ratings specified by the respective manufactures capable of delivering the required power for alternator Stan dared accessories with Diesel Engine Flywheel housing and flywheel to suit single bearing alternator (close coupled arrangement) Air cleaner Radiator with fan and fan guard Fuel pump Mechanical governor Fuel filter Lubricating oil filter Residential type exhaust silencer Battery charger / generator Electrical Starter motor 12 V DC Control panel The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for a weather-proof, long lasting finish. The control panel consists of following parts: Standard engine instrumentation Multi function meter which measures: Current (Amps) Phase voltages (V) Generator output frequency (Hz) Engine water temperature (Deg.C) Lube oil pressure (kg/cm2) and equipped with hour counter MCB of suitable rating Key switch Push button (Starter) LED: Battery charging alternator fail indication Current transformers Instrument fuses duly wired and ferrules Safety Controls for Engine Trip for low lubricating oil pressure Trip for high water temperature Providing necessary warning systems and other safeties as contemplated in relevant ISS Fuel pipe Oil resistant flexible hoses or MS pipe as per manufactures requirement for fuel line Alternator Make: Kirlosker/KEL/Greaves/Stamford Type: self excited, self regulated through an AVR Capacity: 15KVA/20 KW at 0.8 PF System Voltage: , 1 phase 240V,50 Hz Speed: 1500 RPM Voltage regulation band: + 1.0 % Voltage regulation (max.) in static conditions Insulation: Class F/H The alternator should confirm to IS 4722. Mounting arrangement Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Fuel tank Integral type fuel tank Battery Required number of suitable rated fully charged battery with leads and terminals as required as per manufactures requirements including with mode power to charge supply (SMPS) Acoustic enclosure The DG set shall be supplied along with specially designed, company fabricated (to be fabricated in the same company from where the DG set is delivered ) acoustic enclosure to meet the stringent MOEF/CPCB norms of 75 dBA @ 1m at 75% load under free field conditions. Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability. Air inlet louvers specially designed to operate at rated load. The enclosure shall be with UV resistant powder coating capable to withstand extreme environments. Insulation materials shall conform to IS 8183 specifications for better sound attenuation. Fluid drains for lube oil and fuel Fuel filling point Documents to be supplied Engine manual Spare parts book Warranty certificate Alternator manual & test certificate 1 set control wiring drawing Installation It shall be installed in the pr-constructed concrete bed complying to relevant IS standards, IE rules and as per the direction of the departmental officials Testing and commissioning The DG set shall be tested as per relevant IS standards. The load required for testing shall be made available at site by the selected agency at his own expense. Warranty The DG set shall be guaranteed for three year from the date of commissioning from any defects in manufacturing. Any of the spares/components which are found to be defective during this period shall be replaced immediately free of cost. |
| 3 | OD200369/2025-2026:Supply, conveyance and Installation of battery charger suitable for charging battery of DG SET.Input Voltage 240 V AC,output Voltage12V / 24V DC,SMPS based Battery Charger,Protections for Short Circuit / Over load,Battery Reverse Protection with Auto Recovery, LED Indication for Mains ON, Float mode, Boost mode and Battery reverse Polarity with DC operated electronic Alarm with time delay on 150x125x50mm MS box with 3mm sheet including giving connection as required (for KSEB power indication) |
| 4 | OD200374/2025-2026:Supply and providing 75 mm/equivalent size M. S. pipe -5mm thickness B class complete with suitable size 12mm flange coupling with minimum 4/5mtr using allied packing with MS bolt with washer and rising the same on the wall/ parapet using chain pulley, scaffolding's, supports with M.S angles/channels etc. including painting the pipe with one coat of zinc chromate primer over a coat of high temperature resistance aluminum paint etc. for extending the exhaust pipe of the newly erected 20 KVA D. G. sets |
| 5 | OD200368/2025-2026:Charges for conducting load test and trial run of 20 kVA/16KW DG Set |
| 6 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 7 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 8 | 90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm |
| 9 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 10 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 11 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 12 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 13 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 14 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 15 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 16 | OD200364/2025-2026:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 17 | 90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) |
| 18 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 19 | OD200365/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required. |
| 20 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 21 | 14.3:Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres. |
| 22 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 23 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 24 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 25 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 26 | OD200376/2025-2026:Providing and fixing following capacity 4 pole On-Load Change Over In the existing panel board and giving connections as required. 63A, 4 pole On-Load Change Over Switches |
| 27 | OD200378/2025-2026:Providing and fixing following multi function meter to read: V, A, F, 3 phase accuracy class 1 in existing panel and giving connection complete |
| 28 | OD200370/2025-2026:Providing and fixing following metering ct 100/5A 5VA /1A accuracy class 0.5 existing panel and giving connection complete |
| 29 | OD200371/2025-2026:Providing and fixing Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete |
| 30 | OD200367/2025-2026:Providing and fixing Blue colour LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete |
| 31 | OD200375/2025-2026:Supply and providing 6kg dry chemical powder type fire extinguisher with accessories fixed on wall inposition |
| 32 | OD200377/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clearvision.< |
| 33 | OD200379/2025-2026:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of redoxide and written with white paint 'FIRE', filled with fine sand, mounted on existing MS angle frame work / wall bracket etc. as required |
| 34 | OD200373/2025-2026:Fee to be paid to KSELB towards scrutiny & inspection , meter testing and submitting and getting approval, arranging inspection from KSEB, obtaining power allocation & permanent power connection, approval etc. and commissioning of the proposed DG set All statutory payments etc and all drawings for obtaings approval . Please Enable Macros to View BoQ information |