| 1 | Dismantling wall and ceiling boards (fibre/ pulp/ insulation/ Aluminium/ MS sheet/ any type etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets. |
| 2 | Taking down door/ window shutter exc 1 sqm and not exc 2 sqm and removing the same to CIV&HY section store. |
| 3 | Taking down existing chowakts or frames exc 1.5 Sqm but not exc 4 Sqm each and removing the same to CIV&HY section store. |
| 4 | Taking down existing chowakts or frames exc 1.5 Sqm but not exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing the same to CIV&HY section store. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below or above ground level). |
| 7 | Dismantling structural steel work including doors/ gate/ windows but excluding framed truss etc. |
| 8 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key , scrubbing down with water etc. to receive plaster etc. complete. |
| 9 | Excavating over areas, n exc 1.5m deep and getting out hard/ dense soil |
| 10 | M&L for providing cement concrete type B2 1:2:4 mix (40mm graded aggregate) in foundations, filling and mass concrete. |
| 11 | M&L for rendering 30mm thick on stone masonry surfaces or surfaces other than fair faces of brickwork or on one side of lathing in CM 1:4 including rough finish the plastered surface. |
| 12 | M&L for Hard core of gauge n.exc 63mm deposited, spread, and levelled in layers n.exc 15cm thick, watered and rammed to a true surface using broken stone or boulders. |
| 13 | M&L for murum filling in pavings, laid in layers n. exc 15cm thick. Spread, levelled and rammed including watering. |
| 14 | M&L providing precast cement concrete type C1, 1:3:6 (20mm graded aggregate) in block masonry with solid blocks, exc 10cm width and setting in CM 1:6, complete |
| 15 | M&L for 15mm thick rendering with sand faced finish on fair faces of brick or concrete surfaces of walls in CM 1:4. |
| 16 | M&L for 15mm thick rendering with neeru finish on fair faces of brick or concrete surfaces of walls in CM 1:4. |
| 17 | M&L for screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:4 |
| 18 | M&L for joint free Glazed ceramic coloured tiles in vertical surface 450x350x7 mm/ 450x300x7 mm thick, joint free, coloured tiles , set and jointed in neat cement slurry and pointed in white or coloured cement to match. (Make- Johnson, Kajaria, Bell). |
| 19 | M&L for Non-skid coloured cermaic tiles 7mm to 8mm thick (joint free) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match. (Make- Johnson, Kajaria, Bell). |
| 20 | M/L for Vitrified Ceramic tiles light/ any shade 10mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 Sqm but not exceeding 1.0 sqm, in floors etc in light shade, set jointed in neat cement slurry and pointed in white or coloured cement to match. (Make- Johnson, bell, Kajaria) |
| 21 | Filleting in any position and any shape in cement mortar 1:4 n ex 25 sqcm (for filling of skirting top) |
| 22 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick/ any size, set, jointed and pointed in neat cement slurry in floors with mixture of white & grey cement in equal proportions and no pigment. |
| 23 | M&L Cutting chases in brick wall for concealed water tubing, pinning in and making good to facing with cement mortar of 1:3. cutting not exc 10cm girth. |
| 24 | M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 25 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, door frames, window-cill, cooking platform/ wash basin platform and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite. |
| 26 | M&L for providing edge moulding/ groove cutting to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish granite stone or any description etc. complete. |
| 27 | Cutting holes into or through brick wall/ stone wall bulit in cement mortar and making good in cement mortar or cement concrete 1:2:4 Type B-1 as required for superficial area of hole n exceeding 150 sqcm. |
| 28 | S&F of aluminium louvered ventilator with louvered blade of 3mm thick figured glass 100mm wide, each blade riveted to jamb & at a distance of 65mm centre to centre/ as per site requirement including provision of stainless steel mosquito net and fixing of exhaust fan. |
| 29 | S&F Powder coated Anodised Aluminium frame for doors, window, ventilators and partitions with one or more rebates including joining cleat for fixing etc all as specified. |
| 30 | S&F Powder coated Anodised Aluminium window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 Nos), suitable handle (1 Nos) complete all as specified. |
| 31 | M&L for 4.80mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5sqm in each pane. |
| 32 | S&F in repairs Stainless steel wire cloth 0.36mm nominal diamater of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples. |
| 33 | S&F Mild steel work in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165. |
| 34 | S&F 30mm thick single piece, coloured ABC (ACRYLONITRILE BRUTADINE STYRENE) coated, PUF filled door shutters with PUF (Poly Urethane Foam) insulation of minimum density 40 Kg/Cum filled in between two ABS sheets of thickness 1.2mm (min), border covered with insitu pasted ABS strips of width equal to thickness of door shutters, 1.2mm thickness, reinforced with two number 10mm CTD bars, pre embedded with wooden blocks of suitable sizes for receiving hinges, tower / sliding bolts, towel rails, handles etc, with/without embossed pattern. |
| 35 | S&F Flush shutters 30mm thick, solid core construction, with block board core and plywood face panels, and both face covered with decorative face lamination with lipping/ frame to match. |
| 36 | S&F plain, solid, straight chowkats and frames wronght framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints using Ist class hard wood. |
| 37 | S&F of Ist class hardwood 40 mm thick, Plain, framed, panelled shutters (any numbers of panels ), with panels of timber flat on both sides (feather edgesd), or of veneered particle board medium density, wood particle board with commercial face veneers. |
| 38 | S&F butt hinges, cast brass, with mild steel hinge pin, bright polished, type B-12 size 125mm. |
| 39 | S&F extruded brass handles, fabricated type polished, size of handle = 150mm |
| 40 | S&F brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed, length of bolt 300 mm. |
| 41 | S&F Brass sliding door bolts, with sand or die-cast brass hasp, staple(bolt type) and fixing bolt with rolled or drawn brass bolts, length of bolt= 375mm. |
| 42 | S&F brass Mortice lock, 4 levers, vertical type, with escutcheon plates and two keys, size 100mm |
| 43 | S&F Mild steel of grade Fe-410-W for framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete. |
| 44 | S&F mild steel sliding door bolts, plate type stove enamelled black with with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on blot plate and two on stople plate and fixed: length of bolt 375mm. |
| 45 | S&F for mild steel butt hinges, heavy weight, cold rolled. Size of hinges 125mm. |
| 46 | S&F for mild steel pressed handles, oval type, stove enamelled black. Size of handle 150mm. |
| 47 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal to store for bore of pipe 15mm |
| 48 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal to store for bore of pipe 25 or 32mm |
| 49 | S&F High density polyethylene (HDPE) pipes or pressure rating 6 kgs/sq.cm fixed complete to walls, ceiling or in floors etc. for waste pipes bore of tube 40mm. |
| 50 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. outer diameter of pipe 20mm |
| 51 | S&F 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. outer diameter of pipe 32mm. |
| 52 | S&F PP-R Gate valves (brass insert) as per requirement of the site, outer diameter of pipe 32mm. |
| 53 | S&F floor mounted ceramic one piece western toilet/ water closet/ commode with soft close toilet seat cover and gaskets inbuilt siphon flush with two options s trap outlet (white) including toilet paper holder. Make: Cera/ Hindware/ Jaquar/ Kohler |
| 54 | S & F Health Faucet (ABS body)mild steel Chromium Plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connection & fixed in position complete all respect as specified |
| 55 | S&F waste fitting brass chromium plated for galzed ware sinks, basins etc with long screwed shanks and fly nuts flange and bedded inred lead cement and other and fixed loose of pipe 32mm. |
| 56 | S&F Vitreous China wash basin (counter top) bowl type, round or oval shape. Make: Jaquar/ Cera |
| 57 | Supply & fixing of Towel Rail 600 mm long chromium plated Make: Jaquar/ Cera. |
| 58 | Supply & fixing of Towel Ring chromium plated Make: Jaquar/ Cera. |
| 59 | Supply & fixing of Acrylic sheet of size 600x600x3mm thick, white colour for ceiling boards. |
| 60 | Supply & fixing of Gypsum GRG ceiling boards reinforced with cellulose fibres for size 600x600x8mm thick. |
| 61 | S&F PVC connection 15mm size with PTMT nuts of length 450mm. |
| 62 | S&F Pillar tap brass chromium plated fancy type suitable for bowl type wash hand basin erect type fixed to granite top and screwed to pipe of bore 15 mm. Make: Jaquar, Cera, Kohler |
| 63 | S&F fancy type chromium plated brass heavy duty two way bib cock fixed to concealed pipe of bore 15 mm. Make: Jaquar, Cera, Kohler |
| 64 | S&F fancy type chromium plated brass heavy duty angle stop cock fixed to concealed pipe of bore 15 mm. Make: Jaquar, Cera, Kohler |
| 65 | S&F fancy type chromium plated brass heavy duty hot & cold mixer with concealed shower, wall mounted and screwed down to concealed pipe of bore 15 mm. Make: Jaquar, Cera, Kohler |
| 66 | S&F looking mirror of selected quality glass of size 600mm x 900mm with LED light border and hung to wall with screws. |
| 67 | S&F Anodised aluminium snap grid frame work for false ceiling all as specified size of grid 605 x 605mm |
| 68 | S&F of Flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern/wash basin/urinal. |
| 69 | S&F PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement diameter of outlet = 75mm. |
| 70 | S&F CPVC Brass elbow 3/4 x 1/2, for outer diameter of pipe 20mm |
| 71 | S&F CPVC female brass threaded adaptor (FTA/FBTA) outer diameter of pipe 20mm |
| 72 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in trenches or in floor. |
| 73 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in trenches or in floor. |
| 74 | S&F PVC (SWR) 75mm bore bends any radius with access door. |
| 75 | S&F PVC (SWR) 110mm bore bends any radius with access door. |
| 76 | S&F Rotational moulded polyethylene water storage tank capacity 1000 litres tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed. |
| 77 | M&L for providing concrete bed to drain pipes including forming cradles in cement concrete 1:3:6: type C2 (40mm graded aggregate) Bore of pipe 150 mm. |
| 78 | M&L for 150mm bore Reinforced concrete drain pipe (for sewer and drains) of class NP2 laid and jointed complete with collors. |
| 79 | M&L providing precast cement concrete type B1, 1:2:4 (20mm graded aggregate) in landings drain cover slab (for manholes etc), lintels, kerbs and similar articles etc. set in cement mortar 1:6. |
| 80 | M&L for deformed or twisted bars, 5mm Dai and over up to 10mm in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 81 | M&L for complete removal of existing treatment and applying the plastered surface with 3 mm thick wall care putty. |
| 82 | M&L for preparation new plastered surfaces of any description over 10cm girth or width not otherwise described and applying two coats of plastic emulsion over one coat of priming paints plaster coat. Make: Asian, berger, Nerolac |
| 83 | M&L for preparing plastered or unplastered old surfaces and finishing walls with Acrylic smooth exterior paint of approved make/manufacturing brand & shade new/ old work (two or more coat applied @ 1.67 ltr/10sqm over) including priming coat of exterior primer applied @ 2.20 kg/10sqm. Make: Asian- Apex, Berger- weather coat, Nerolac- excel, Jotun . |
| 84 | M&L for preparing plastered or unplastered old surfaces and applying two coats of oil emulsion distemper on walls/ceiling. Make: Asian, berger, Nerolac |
| 85 | M&L for preparing old painted surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint on wood or wood based surfaces. Make: Asian- Apcolite, Berger- luxol, Nerolac- synthetic higloss, Jotun . |
| 86 | M&L for preparing old painted surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over steel and iron surfaces. Make: Asian- Apcolite, Berger- luxol, Nerolac- synthetic higloss, Jotun . |
| 87 | S&F of Kitchen cabinet trolley & Crockery consisitng of:1) Kitchen trolley with 6 drawers and 1 cupboard of size 72\\"x30\\"x30\\". 2) Kitchen trolley with 4 storage of size 48\\"x30\\"x30\\".3) Crockery unit above kitchen platform of size 82\\"x24\\"x18\\".4) Kitchen storage under kitchen sink of size 96\\"x30\\"x30\\" with 3 storage cupboards. |
| 88 | Removing surplus excavated soil/rock and demolished material to a distance exc 250m but n exc 500m and depositing where directed. |
| 89 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to EM for keeping in safe custody and making good disturbed surfaces of walls, floors, etc. |
| 90 | Point wiring in PVC casing & Caping for one light point / one fan point /Bell point controlled by one switch with PVC insulated stranded copper conductor (FR class 2) wire 1.5 sq. mm size including material and labour. (Make of wire - Polycab, Finolex, KEI, RR Kable & PVC Casing & Caping - Modi, Pressfit only.) |
| 91 | M&L Point wiring in PVC Conduit for one light point / one fan point /Bell point controlled by one switch with PVC insulated stranded copper conductor (FR class 2) wire 1.5 sq. mm size. (Make of wire - Polycab, Finolex, KEI, RR Kable & PVC Conduit - Modi, Pressfit, Diamond only.) |
| 92 | M&L Point wiring in PVC Conduit / casing & Caping for one light point controlled by additinal on existing one switch with PVC insulated stranded copper conductor (FR class 2) wire 1.5 sq. mm size (for each additional light point on the same switch circuit ) (Make of wire - Polycab, Finolex, KEI, RR Kable & PVC Conduit /Casing & Caping - Modi, Pressfit only.) |
| 93 | M&L Point wiring in PVC casing & Caping for one 3 pin socket outlet, 5 Amps, independent with stranded copper conductor wire (FR Class 2) of 2.5 sq. mm size. (Make of wire - Polycab, Finolex, KEI, RR Kable & PVC casing & Caping- Modi, Pressfit only.) |
| 94 | M&L Point wiring with stranded copper conductor in PVC Casing & Caping for one 3 pin socket out let 5Amp. on the same board with other switches with FR Class 2, wire 2.5 sq. mm size (Make of wire - Polycab, Finolex, KEI, RR Kable & PVC casing & Caping- Modi, Pressfit only.) |
| 95 | S&F of modular switch, 1 way, 6A, 1 module. Make- Legrand/Anchor- Roma/L&T only. |
| 96 | S&F of modular socket, 6A - 2/3 pin combined, 2 module. Make- Legrand/Anchor- Roma/L&T only. |
| 97 | S&F of modular switch, 1 way, 16 Amps, 1 module. Make- Legrand/Anchor- Roma/L&T only. |
| 98 | S&F of modular socket, 6A/16A - 2/3 pin combined 2 module. Make- Legrand/ Anchor- Roma/ L&T only. |
| 99 | S&Fof modular switch, 2 way, 10 Amps, 1 module. Make- Legrand/Anchor- Roma/L&T only. |
| 100 | S&F of bell, (Ding - dong Type) AC 230V, single pole. Make- Cona, Anchor, Havells only |
| 101 | S&F of modular bell push, 6A, 1 module . Make- Legrand/Anchor- Roma/L&T only. |
| 102 | S&F of modular metal / Plastic /PVC Heavy duty flush box, 6 module. |
| 103 | S&F of modular white cover plate with frame , 6 module. Make- Legrand/Anchor- Roma/L&T only. |
| 104 | S&F of modular metal / Plastic/PVC Heavy duty flush box, 3 module |
| 105 | S&F of modular white cover plate with frame , 3 module. Make- Legrand/Anchor- Roma/L&T only. |
| 106 | S&F of modular metal / Plastic/PVC Heavy duty flush box, 2 module. |
| 107 | S&F of modular white cover plate with frame , 2 module. Make- Legrand/Anchor- Roma/L&T only. |
| 108 | S&F of modular metal / Plastic /PVC Heavy duty flush box, 1 module. |
| 109 | S&F of modular white cover plate with frame , 1 module. Make- Legrand/Anchor- Roma/L&T only. |
| 110 | S&F of Celling rose with plate/board, 3 point,, PVC/Polycarbonate, Isolated body. Make- Legrand/Anchor- Roma/L&T only. |
| 111 | S&F of Lamp holder, angular/ batten , PVC/ Polycarbonate type with plate / board suitable for batten fittings , PVC/ Polycarbonate, Isolated body. Make- Legrand/ Anchor- Roma/ L&T only. |
| 112 | Fixing only LED luminaire (Panel light) 600mmx600mm, 35/36 Watt 220V AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder, & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor case with connector of suitable size complete. Make Crompton, Orient, Philips etc. |
| 113 | S&F LED light fitting 1x20 watt, 230 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilling rose complete. Of Make Crompton, Orient, Philips etc. |
| 114 | S&F LED foot light 2 to 5 Watt, Make Crompton, Orient, Philips or equivalent etc. |
| 115 | S&F of ceiling fans complete with 3 blades, Required down road 1 to 6 feet as per requirement, electronic regulator / remote control for speed control, other accessories, 230 volt, 1200 mm sweep, Energy efficient, five star rated with brush less direct current motor (BLDC) of wattage range between 26 to 35 watt, prewired up to connection of make Automberg, Orient, Crompton, Usha only. |
| 116 | S&F Exaust fan , made of sturdy engineering plastic complete with louvers shutters, AC single phase , 230 V of size 300mm sweep, copper winding, all complete up to connection to ceiling rose. Make Usha, Crompton, Polycab, Orient, Almonard etc. |
| 117 | S&F Gate Light 12inch to 18 inch 15 to 30 watt of make Bajaj, Crompton, Wipro, Orient or equivalent. |
| 118 | Supply and fixing Gyser 10 litrs storage type, single phase, 230V AC, 5 star rated, including connection up to plug point and water inlet and out let all complete of make Crompton, AO Smith, Recold, Orient, bajaj only |
| 119 | M&L Wiring for circuit/sub main wiring along with earth wire with 2X6 Sq. mm + 1X6 sq. mm earth wire sizes of FR PVC insulated stranded copper conductor, single core cable in surface/recessed as required in PVC Casing & Caping. Make of wire- Polycab/ Finolex/ KEI/ RR Kable only. make of Casing caping - Modi, Pressfit only |
| 120 | M&L Wiring for circuit/sub main wiring along with earth wire with 2X4 Sq. mm + 1X4 sq. mm earth wire sizes of FR PVC insulated stranded copper conductor, single core cable in surface/recessed as required in PVC Casing & Caping. Make of wire- Polycab/ Finolex/ KEI/ RR Kable only. make of Casing caping - Modi, Pressfit only |
| 121 | S&F of single pole and neutral encloser with a two pin and earth plug and socket complete with one single pole 20/25 Amp MCB, Suitable for AC connection, Make - Legrand/ Indo asian/ schneider/ ABB/ L&T only. |
| 122 | S&F of sheet metal encloser, single door MCB DB (Distribution board), single phase 240 Volt, 2-way, for MCBs, with neutral link, Make - Legrand/ Indo asian/ schneider/ ABB/ L&T only. |
| 123 | S&F of sheet metal encloser, Double door MCB DB, Three phase, 415V, 4-way, for MCB / RCBO, with neutral link, Make - Legrand/ Indoasian/ Schneider/ ABB/ L&T only. |
| 124 | S&F of sheet metal encloser, single door MCB DB, 240V. single phase phase, 8-way, for MCB / RCBO, with neutral link, Make - Legrand/ Indoasian/ Schneider/ ABB/ L&T only. |
| 125 | S&F of sheet metal encloser, single door MCB DB, single phase phase, 12-way, for one RCBO /MCB, with neutral link, Make - Legrand/ Indoasian/ Schneider/ ABB/ L&T only. |
| 126 | S&F of RCBOs Earth leakage, Overload & Short- Circuit Protection 30mA, Double pole, 25-40 Amp. 240V, complete with connection testing and commissionning. Make - Legrand/ Indo asian/ schneider/ ABB/ L&T only. |
| 127 | S&F of MCB, B-Type, 10kA, Four Pole (MCB TPN) , 415V, 16-32A complete with connection testing and commissionning. Make - Legrand/ Indo asian/ schneider/ ABB/ L&T only. |
| 128 | S&F of MCB, B-Type, 10kA, Tripal Pole (MCB TP) , 415V, 25-63A complete with connection testing and commissionning. Make - Legrand/Indo asian/ schneider/ ABB/ L&T only. |
| 129 | S&Fof MCB, C-Type, 10kA, Double Pole (MCB DP)/SPN , 240V, 32A complete with connection testing and commissionning. Make - Legrand/ Indo asian/ schneider/ ABB/ L&T only. |
| 130 | S&F of MCB, C-Type, 10kA, Single Pole (MCB SP), 240V, 6A,-32A complete with connection testing and commissionning. Make - Legrand/ Indo asian/ schneider/ ABB/ L&T only. |
| 131 | S&F LED street light fitting 50 to 60 watt 230 V AC outdoor type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection complete. Make - Crompton, Orient, Philips etc. |
| 132 | S&F of Bollard fittings with LED 10 to 20 Watt, Single phase, size 60 CM to 100 CM high decorative type. Make Bajaj, Orient, Cromplton, Phillips or Equivalent. Including foundation and connection all complete. |
| 133 | M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & Screws as specified type 410 SP -22, length of pole 8.5 Mtrs. Including painting. |
| 134 | Supply and erecting three phase 415V street light control panel up to the max load of 6kW TPN MCB 40A powder coated CRCA 14 SWG sheet, outdoor type having IP54 Ik10 protection, suitable rating contractor 24 hrs astronomical time switch with minimum 5 years battery backup auto / manual selector switch, ON/OFF push buttons, indicators lamps, control wiring metering device etc. for automatic operation with overcurrent short circuit earth fault protection and additinal 6 way MBCB DB with 6 SP MCB of sitable capacity for controling varius outgoing circuits, on provided iron frame / CC foundation. including all connection of cables, control wiring etc, suitable size with powdwr coating paint, stand with foundation. |
| 135 | S&F framed brackets of pipes / angles or tees with web and flanges cut to sahpe, drilled and countersunk for screw, including bending and welding pipes/angles as necessary, n.exc 10 kg each brackets, for street light fittings on pole. |
| 136 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor , 1100V grade, cross section area 10 sq. mm 4 core of make- Polycab, Havells, KEI only. |
| 137 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor , 1100V grade, cross section area 10 sq. mm 2 core of make- Polycab, Havells, KEI only. |
| 138 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor , 1100V grade, cross section area 4 sq. mm 2 core of make- Polycab, Havells, KEI only. |
| 139 | Supply and laying DWC pipe 50mm normal duty, pliable type for protection of cables. |
| 140 | Excavation in trenches n exceeding 1.5 m wide and n exceeding 1.5 m depth and getting out in Hard soil. |
| 141 | Excavation in trenches n exceeding 1.5 m wide and n exceeding 1.5 m depth and getting out in Soft rock. |
| 142 | Excavation in trenches n exceeding 1.5 m wide and deep below the 1.5 m depth and getting out in Hard rock. (up to 2.25 meter depth) |
| 143 | M&L sand filling under floor/ cushioning of the underground cable or in foundation including watering and consolidation. |
| 144 | Supply and laying in trenches of galvanised steel tubes, medium grade size 100 mm, include for one plain socket to each length of pipe. Make:- Tata, JSPL only. |
| 145 | Supply and laying reinforced precast concrete cable cover, class LV, Type 1 flat size 250mmX150mmX40mm. |
| 146 | M&L cement concrete in foundation, filling and mass concrete. ( Type C2 1:3:6 40mm graded aggregate) |
| 147 | Earthing complete with galvanized iron earth plate electrode 60X60cmX6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI earth lead strip of size 25X4 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified with material or indicated including testing on completion. |
| 148 | Supply and fixing of galvanized tubes medium grade 15mm bore. |
| 149 | M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6. |
| 150 | M&L Rendering 10mm thick on fair faces of brickwork or concrete surface in cement plaster 1:4. |
| 151 | M&L Cast iron work grade FG 150 unmachined , in brackets ,gully traps, grating railings , frames ,manhole covers / Earth chamber cover below 5 KG , fire and soot doors, dampers, stop valve boxes, gate stops, part of ranges balusters and similar articles. |
| 152 | Returning filling in , including spreading , levelling, watering, and well ramming in layers of hard soil |
| 153 | Supply and fixing of LT Cable root marker with supporing angle painting and all Total 40CM Height |
| 154 | S&F of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanized iron or steel wire. |
| 155 | Installation and cabling wiring for the internet and telephone with gang box socket at qtr no.11 at OE as per scope of work AFK/ EM/ TE/ Dt 29-01-2028 attached. Please Enable Macros to View BoQ information |