| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | 01-CIVIL WORKSNote: 1) The method of excavation shall be approved by the Engineer in charge before execution. 2) Excavation shall be carried out very carefully without damaging existing structures and surrounding if any.3) If required, the contractor shall provide stabilization by any means to protect the foundation of the existing structure and building without any extra cost.4) The rate shall include dewatering work (pumping out and removing slush) during execution in underwater conditions, if required.Sec.1.0 Earth work Excavation for all kinds of soil and Rock with backfillingEarthwork in excavation for all kinds of soil or rock by any means (Mechanical/Manual) including getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of the bottom, and disposal of surplus excavated earth for all lead within the site area/ plot boundary and lift upto 1.5 mt depth including dewatering and working in or under water and/or liquid mud, including pumping out water/slush as required etc complete, including back Filling available approved excavated earth (excluding rock & black cotton soil) anywhere from the site/campus etc. in trenches, plinths, sides of foundations, plot filling, etc. in layers not exceeding 20cm in depth, with optimum moisture content to achieve at least 95% of the maximum dry density (proctor density) including watering, ramming, and compacting by any means for compaction, including transportation, loading, unloading, screening, passes, etc. complete for all lead (from anywhere within the site/ plot area) and lift and as directed by the Engineer-in-charge. |
| 3 | Excavation for all kinds of soil and Rock with backfillingEarthwork in excavation for all kinds of soil or rock by any means (Mechanical/Manual) including getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of the bottom, and disposal of surplus excavated earth for all lead within the site area/ plot boundary and lift from 1.5 mt to 3.0 mt depth including dewatering and working in or under water and/or liquid mud, including pumping out water/slush as required etc complete, including back Filling available approved excavated earth (excluding rock & black cotton soil) anywhere from the site/campus etc. in trenches, plinths, sides of foundations, plot filling, etc. in layers not exceeding 20cm in depth, with optimum moisture content to achieve at least 95% of the maximum dry density (proctor density) including watering, ramming, and compacting by any means for compaction, including transportation, loading, unloading, screening, passes, etc. complete for all lead (from anywhere within the site/ plot area) and lift and as directed by the Engineer-in-charge. |
| 4 | Excavation for all kinds of soil and Rock with backfillingEarthwork in excavation for all kinds of soil or/and rock by any means (Mechanical/Manual) including getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of the bottom, and disposal of surplus excavated earth for all lead within the site area/ plot boundary and lift from 3.0 mt to 5.0 mt depth including dewatering and working in or under water and/or liquid mud, including pumping out water/slush as required etc complete, including back Filling available approved excavated earth (excluding rock & black cotton soil) anywhere from the site/campus etc. in trenches, plinths, sides of foundations, plot filling, etc. in layers not exceeding 20cm in depth, with optimum moisture content to achieve at least 95% of the maximum dry density (proctor density) including watering, ramming, and compacting by any means for compaction, including transportation, loading, unloading, screening, passes, etc. complete for all lead (from anywhere within the site/ plot area) and lift and as directed by the Engineer-in-charge. |
| 5 | Excavation for all kinds of soil and Rock with backfillingEarthwork in excavation for all kinds of soil or/and rock by any means (Mechanical/Manual) including getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of the bottom, and disposal of surplus excavated earth for all lead within the site area/ plot boundary and lift from 5.0 mt to 7.0 mt depth including dewatering and working in or under water and/or liquid mud, including pumping out water/slush as required etc complete, including back Filling available approved excavated earth (excluding rock & black cotton soil) anywhere from the site/campus etc. in trenches, plinths, sides of foundations, plot filling, etc. in layers not exceeding 20cm in depth, with optimum moisture content to achieve at least 95% of the maximum dry density (proctor density) including watering, ramming, and compacting by any means for compaction, including transportation, loading, unloading, screening, passes, etc. complete for all lead (from anywhere within the site/ plot area) and lift and as directed by the Engineer-in-charge. |
| 6 | Providing material and labour for Disposing off the un-used excavated earth (black cotton soil), debris, malba, dismantled materials for all lead and lift/ depth out side the campus at non objectional place as directed by Engineer in charge. |
| 7 | Filling of sandProviding and filling in plinth, underfloor, sunk, subbase of any elements or other locations as per the drawing with river sand/ manufactured sand, etc including, watering, ramming consolidating, and dressing complete for all lead and all lift and as directed by the Engineer-in-charge. |
| 8 | Filling of good earth/ murrum brought from outsideExcavating, supplying, and filling of good earth/ murrum brought from outside (including royalty) by any means; in trenches, plinths, sides of foundations, plot filling, etc. in layers not exceeding 20cm in depth, with optimum moisture content to achieve at least 95% of the maximum dry density (proctor density) including watering, ramming and compacting using any means for compaction, including transportation, loading, unloading, screening, passes etc. all complete for all lead and all lift and as directed by the Engineer-in-charge. |
| 9 | Anti-termite treatmentProviding and injecting Chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of the plinth filling, inside the junction of wall and floor, on top of damp proof course or on masonry at the level of plinth filling as per IS 6313 (Part-2)-2013 using a chemical like Imidacloprid 30.5% SC (CIB approved, BIS & CBRI certified). The proportion of dilution with water shall be as per manufacturer's specification. The emulsion shall be applied as mentioned below, all as per the specifications and directions of the Engineer-in-charge. A guarantee bond of 10 years shall be furnished in the prescribed proforma. The rate shall be inclusive of material required for Anti Termite Treatment, labour and equipment as required for application in any condition, as directed by the Engineer-in-Charge. (The stage of treatment may vary as per site conditions and should be approved by the Engineer-in-charge before execution.)a) Treatment of the soil below the raft or any type of foundation - before laying the PCC, the compact and leveled soil shall be treated at 5 liters per sqm. In case of soils/ sand filled above the raft, the treatment at 5 liters per sqm shall be carried out on the top surface of filled soil/sand.b) Treatment of the soil along the retaining wall - The soil retained by the walls (soil in contact with the retaining wall) shall be treated at the rate of 7.5 liters per sqm of the vertical surface in full depth. (for more description please refer PDF file) |
| 10 | 7) Any type of suitable material and/or proprietary formwork system to achieve a fair finished concrete with any shape and any size in plan and elevation including centering, shuttering, strutting, propping, and removal, etc.for all elements, all floors, all level, any heights/ depths, any lead and lift is included in the item. The height of the propping and centering below supporting floor to ceiling shall be as per requirement and removal of the same for in-situ reinforced concrete and plain concrete work, etc complete and as directed by the Engineer-in-charge. 8)In case of any type of cutout in Any RCC element, No additional payment to be made to form it. 9) Rate shall be included for dead shuttering wherever required as per design requirement. no any extra payment to be made towards it. lightweight AAC bats - filling in sunken slabProviding and filling lightweight AAC bats (of size 40-60 mm) with cement mortar mixed in the ratio 1:3:6 (1 cement : 3 coarse sand: 6 block bats) including mixing of approved waterproofing compound in recommended proportion. The laid AAC bat mix shall be well-rammed, compacted, finishing and curing as required. Further, the surfaces shall be screeded with cement concrete mix 1:1.5:3 (1 cement: 1.5 coarse sand : 3 stone grit of size 6 mm and below by volume) admixed with approved integral waterproofing compound in recommended proportion, laid to an average thickness of 25mm and finished smooth or ready to receive finish material as specified. Care shall be taken prior to filling all pipes passing through the sunk portion such that the pipes are pressure tested by maintaining pressure for 24 hours. Junctions of pipes passing through walls, and slabs shall be well grouted and sealed.This shall be tested by ponding water for the required depth and maintaining it for 72 hours. (Rate includes the cost of AAC bats, cement mortar, top screed, and labour charges for working at all levels, leads, and heights). For payment, the area of the sunken slab and the depth of filling including the thickness of the screed shall be measured. |
| 11 | Concrete (PCC) of grade - M15Providing and laying in position machine-batched, machine-mixed Plain Cement Concrete (PCC) of grade - M15, including compaction, vibration, curing, transporting, finishing, and pumping wherever necessary, dewatering (if required), formwork/ shuttering etc. complete for all levels, all heights/depths, and for all lead and lift and as directed by the Engineer-in-charge. |
| 12 | Reinforcement for R.C.C.Providing Thermo-Mechanically Treated bars Fe 500 D reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, and binding (with GI wire of required thickness or 18 SWG -1.22 mm GI wire unless otherwise specified), all complete for all leads and lifts, all levels, all floors, all heights/depths, etc complete as per drawing, specification and as directed by the Engineer-in-charge.No separate payment shall be made for chairs, pins, lifting hooks, spacers, wastage, rolling margin, and binding wire. |
| 13 | Epoxy coating on reinforcement barsProviding fusion bonded Epoxy coating not less than 175 micron thickness and upto 300 micron to reinforcement bars of any diameteer as per IS-13620-1993/ ASTM-775 M including testing of coating at the plant, transporting, loading, unloading, etc complete and as directed by the Engineer-in-charge. The actual weight of reinforcement bars for which epoxy coating has been carried out shall be measured for payment without considering wastage. |
| 14 | Providing material and labour for laying in position Ready Mixed M-20 grade concrete/ batch mix concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge. |
| 15 | Providing material and labour for laying in position Ready Mixed M-25 grade concrete/ batch mix concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge. |
| 16 | Providing material and labour for laying in position Ready Mixed M-30 grade concrete/ batch mix concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge. |
| 17 | Providing material and labour for laying in position Ready Mixed M-35 grade concrete/ batch mix concrete for reinforced cement conctere work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge. |
| 18 | Expansion joint Filler boards Providing and fixing 100/150/200 mm thick premoulded compressible, high performance closed cell, bitumen free expansion joint filler boards of specified thickness in black colour of an approved make, having a minimum density 95 Kg/ Cum, non-staining, with less than 0.08% water absorption & compression recovery of 92%, (conforming to MORTH specification clause 1015) including cutting to required size and shape, at all levels/all floors/all heights, etc. complete, as per the issued drawings/ specifications and as directed by the Engineer-in-charge. |
| 19 | Polysulphide sealantProviding and filling the expansion joints up to required depth & width, with polysulphide sealant with the application of primer including scraping/removing the expansion filler materials from the joints, cleaning, repairing the edges with epoxy mortar of approved color and make, placing backup material (polyethylene backer rod), fixing of abro masking tapes on the edges to protect the adjoining surface, at all levels/ all floors/all height etc. complete as directed by the Engineer-in-charge. The Polysulphide sealant shall conform to BS-4254:1983 and ASTM C920, and be resistant to water, diluted alkalis, cement grout, water-dispersed detergents, etc. The Contractor shall furnish a performance guarantee of 10 years against leakage, and debonding from the edges. |
| 20 | Providing material and labour for Cutting holes of required size in brick/ block masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 21 | Providing and fixing of expansion/ seismic joint system for 100 /150 /200 mm wide expamsion joint gap of approved make related with floor location (floor to floor or floor to wall corner) with stone fixing arrangement (minimum 20mm recess depth for receiving stone) as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning/ self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and match with finish floor treatments.The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of edge preparation, moisture barrier, polyester powder coating (min 50 micron) on aluminum of approved shade and make if required. Cost of flooring stone/ tile shall be paid in relevant tender item. Expansion joint system shall be as approved for all floor all level including scaffolding etc complete. |
| 22 | Providing and fixing of expansion/ seismic joint system for 100 /150 /200 mm wide gap of approved make related with wall joint (internal wall to wall/ ceiling to ceiling/ wall to corner/ any angle) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall or ceiling at corner/ ceiling application, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multi cellular to facilitate movement. Expansion joint system shall be with all mandatory requirement as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of edge preparation, moisture barrier, polyester powder coating on aluminium of approved shade and make if required. Expansion joint system shall be as approved for all floor all level including scaffolding etc complete. |
| 23 | Providing and fixing of expansion/ seismic joint system for 100 /150 /200 mm wide gap of approved make related with External wall joint location (wall to wall/ wall to corner) as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall or ceiling at corner/ ceiling application, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multi cellular to facilitate movement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of edge preparation, moisture barrier, polyester powder coating on aluminium of approved shade and make if required. Expansion joint system shall be as approved for all floor all level including scaffolding etc complete. |
| 24 | Sec 3.0: Centering & Form worksExposed concrete formworkExtra for providing and fixing formwork for exposed concrete surfaces with any pattern (vertical or horizontal surface of any shape) to achieve the desired finish for any element in the desired pattern and size as per the issued drawings and specifications. This includes using any type of formwork material/suitable proprietary formwork system (material/ system shall be approved by the Engineer-in-charge before procurement) to achieve the desired finish as per the approved sample for any type of RCC element including neat cleaning, grinding, rendering the exposed concrete surface, as directed by the Engineer-in-charge, However, Black film plywood of required thickness and approved make of required size & shape to be used as a formwork material with required framing for exposed concrete work to acheive satisfactory finishing. The rate shall be applicable for all levels, all places, and all shapes and shall include all necessary specialized centering/shuttering materials. The Contractor shall submit a shuttering pattern/ shop drawing including tie-rod hole positions, and Architectural grooves and cutout based on the Architectural intent with the control line. this item shall be executed only after the shuttering pattern is approved by the Architect and the Engineer-in-charge. The same kind of shuttering material should be used for standard as well as residual sizes. These areas shall be entirely free from honeycombing, stains, fins, lipping, nail or screw marks, raised grain marks, air holes, or any other imperfections; bulging, offsets, misalignment of the concrete and shall have an even shade, texture, and level throughout. At the construction joints, the formwork should be tightly fixed and securely anchored, close to the joints for seamless construction. Number of repetation of shuttering shall be minimum enough to acheived satisfactory finish of concrete, and no any additional cost to be paid for it. The Contractor shall get prior approval for the reuse of the shuttering material for repetition from the Engineer-in-charge. Mock-ups for all exposed work (with concrete & TMT, however Concrete & TMT for mock up work shall be paid in relevant tender item, however exposed shutering for mock up work shall not be payable) to be prepared by the Contractor and approved by the Architect before mass execution work. Required number of exposed work mock up shall be prepared as per design intent untill satisfactory finish is not recived without any extra cost for shuttering work. The Architect reserves the right to reject part or all of the work that is substandard or not conforming to the approved sample as per the mock up. The rate shall also include the cost of providing Architectural grooves, rendering, buttons(including finishing the groves/button with approved grouting material wherever required) of required size and pattern in concrete work as per the issued drawing, cut-out of any size in concrete elements as per drawing, etc in formwork. In case of round window opening in exposed RCC wall, for payment of expose shuttering opening cutout shall not be deducted (both side). Rate shall be applicable for all floors, all levels, all places and all shapes. The contractor shall submit shuttering pattern including tie-rod hole position based on architectural conceptual drawings. (Same kind of shuttering material should be only used for standard and residual sizes.) Tie-rod hole shall be filled with polymer mortar/ polymer concrete as per manufacturer's specification. |
| 25 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 4.0 mt & upto 5.0 mt. |
| 26 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 5.0 mt & upto 9.0 mt. |
| 27 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 mt. Between supporting floor two ceiling including temporary brick or stone pillars for supporting as required. (I) Height more than 9.0 mt & upto 13.50 mt. |
| 28 | Sec.4.0 Masonry worksProviding material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. |
| 29 | Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in superstructure above plinth level for all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. |
| 30 | Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. |
| 31 | Providing and laying block masonry for jali works using 200mm thick hollow concrete blocks of different sizes, having M25 grade strength, from an approved manufacturer to create a pattern as per the issued drawings, confirming to IS 2185 Part I grade A (7.0). Block Jali wall shall be constructed in cement mortar 1:2 (1 cement: 2 coarse sand) with 2 no. 5 mm dia. GI bars at every three layers vertically as well as horizontally. GI rods shall be anchored in the adjoining surface with rebar grout including finishing, curing, scaffolding, racking/flush jointing, pointing, rendering with cementitious grout of an approved make and shade, roughening, cleaning, fixing, in line, level and pattern, complete for all levels, all floors, all heights, as per the issued drawings and as directed by the Engineer-in-charge.The rate shall be inclusive of the precast block, GI rod, rebar grout, cementitious grout, mortar, joining chemical (if required) etc. A loose sample of the material shall be approved by the Architect before execution. The Contractor shall prepare the shop drawings including the framing system and get approval from the Engineer-in-charge and prepare a mock-up as per the concept drawing and approved shop drawing for approval from the Architect before execution. The installed area (one side) of the block jali shall be measured for payment, without deducting the hollow gaps.The Contractor shall be responsible for the structural stability and safety of the jali works. |
| 32 | SEC:5 Doors and Windows workALUMINIUM WORKS -Providing material and labour for fixing in position frames, shutter for any type of aluminium work for any type of door, window, partition, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors, all levels, all heights, all shapes, all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections (for using fabrication without considering any wastage) shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame; 2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of approved make for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of section for connecting style and horizontal rails; 6) providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required. and excluding the cost of necessary hardware and Glazing or Infill material. |
| 33 | Fix Louvers and Fins (made out of Aluminium Section)Providing, fixing, designing aluminium fixed louver of any type of louver section of approved make having minimum 50 micron polyster powder coating on all the surfaces of approved shade, texture & make as per manufacturer's specifications. Contractor shall submit the shop drawing for louver/ fins based on concept design/ drawing and as per elevation. Aluminium louver section shall be fixed on aluminium framing/ carrier/ panel/ GI clip and necessary sub structure with required fastners, hardware as per approved shop drawing etc complete for all floor, all height including scaffolding as directed by engineer in charge. Louver, framing and sub structure shall be in proper line, level and plumb. Necessary MS work shall be paid in relevant tender item. |
| 34 | Alumium Openable/Operable Louvers Providing and fixing aluminum operable system (hand-operated) louvers for door/window/opening sizes as per issued drawings of an approved make, having 50-micron polyester powder coating of approved shade & color and texture including operating mechanism louver frame with gasket and piles. The corner joints of the frame shall be made at 45 degrees using die-cast solid aluminum corner cleats fixed with a spring for rapid and secure joint assembly. Gaskets shall be of micro waved EPDM material. Work shall be carried out in the door/window frame as per the sample approved by the architect and Engineer-in-charge. The operating panel shall be provided as per the issued drawing. the out-to-out dimension of the operable louver system shall be measured for payment. The rate shall be inclusive of the aluminum frame for the louver operating system. The sample/mockup shall be by contractor approved before the execution of the work based on the approved shop drawing. Work shall be carried out as per the approved shop drawing, and approved sample/mock-up. |
| 35 | Glass Louvers VentilationProviding and fixing standared extruded of alluminium section of size 63mm x 38.10mm x 1.2mm (Jindal Section:2434, @Wt.0.643Kg/mt) or euivalant with colour Powder Coated alluminium frame for ventilation with 5mm thick frosted glass as details etc complete for Ventilation |
| 36 | Providing and fixing 6mm thick Clear Toughen Glass in the door, window, ventilation, fixed glazing, partitions, etc. with necessary cutting of the glass & edge tretament of the glass for all levels, all floors, all heights with required size/thickness/dimension EPDM rubber/neoprene gasket/silicon sealant/ structural sealant/Adhesive tap on periphery of the glass all of approved make, etc. complete as per the issued drawings and directions of the Engineer-in-charge. (Cost of beading shall be covered under basic item). Glass shall be of any shade, any size, any shape of approved make as per issued drawing and confirm to IS:2835 or IS:2553. The sample shall be approved before execution of the work. The installed area shall be measured for payment without considering any wastage. |
| 37 | Providing and fixing 8mm thick Clear Toughen Glass in the door, window, ventilation, fixed glazing, partitions, etc. with necessary cutting of the glass & edge tretament of the glass for all levels, all floors, all heights with required size/thickness/dimension EPDM rubber/neoprene gasket/silicon sealant/ structural sealant/Adhesive tap on periphery of the glass all of approved make, etc. complete as per the issued drawings and directions of the Engineer-in-charge. (Cost of beading shall be covered under basic item). Glass shall be of any shade, any size, any shape of approved make as per issued drawing and confirm to IS:2835 or IS:2553. The sample shall be approved before execution of the work. The installed area shall be measured for payment without considering any wastage. |
| 38 | Providing and fixing 10mm thick Clear Toughen Glass in the door, window, ventilation, fixed glazing, partitions, etc. with necessary cutting of the glass & edge tretament of the glass for all levels, all floors, all heights with required size/thickness/dimension EPDM rubber/neoprene gasket/silicon sealant/ structural sealant/Adhesive tap on periphery of the glass all of approved make, etc. complete as per the issued drawings and directions of the Engineer-in-charge. (Cost of beading shall be covered under basic item). Glass shall be of any shade, any size, any shape of approved make as per issued drawing and confirm to IS:2835 or IS:2553. The sample shall be approved before execution of the work. The installed area shall be measured for payment without considering any wastage. |
| 39 | Providing and fixing 12mm thick Clear Toughen Glass in the door, window, ventilation, fixed glazing, partitions, etc. with necessary cutting of the glass & edge tretament of the glass for all levels, all floors, all heights with required size/thickness/dimension EPDM rubber/neoprene gasket/silicon sealant/ structural sealant/Adhesive tap on periphery of the glass all of approved make, etc. complete as per the issued drawings and directions of the Engineer-in-charge. (Cost of beading shall be covered under basic item). Glass shall be of any shade, any size, any shape of approved make as per issued drawing and confirm to IS:2835 or IS:2553. The sample shall be approved before execution of the work. The installed area shall be measured for payment without considering any wastage. |
| 40 | Providing and fixing 06 mm thick wired Glass in the door, window, ventilation, fixed glazing, partitions, etc. with necessary cutting of the glass & edge tretament of the glass for all levels, all floors, all heights with required size/thickness/dimension EPDM rubber/neoprene gasket/silicon sealant/ structural sealant/Adhesive tap on periphery of the glass all of approved make, etc. complete as per the issued drawings and directions of the Engineer-in-charge. (Cost of beading shall be covered under basic item). Glass shall be of any shade, any size, any shape of approved make as per issued drawing and confirm to IS:2835 or IS:2553. The sample shall be approved before execution of the work. The installed area shall be measured for payment without considering any wastage. |
| 41 | Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color (single side, double side coloured), any texture of approved make and as per approved sample (approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, provision of groove, filling of groove (both side) as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid. |
| 42 | Providing material and labour for fixing in position SS 304 - 18 x 16 mesh and 32gauge Mosquito net of any size any shape having 50 micron pure polyster powder coating of approved make and shade for aluminium sliding shutter/ fixed shutter or in front of aluminium louvers as per approved shop drawing prepared by contractor. Jali shall be fixed with SS304 grade screws and fasteners required to tighten the Jali/ Net including fxing channel, EPDM quality rubber/ silicon sealant etc complete for all floors, all levels, all heights as directed by engineer in charge. Only installed area of mosquito net shall be measured and paid in Sqm without considering any westage. All aluminium sections shall be paid under relevant tender item. |
| 43 | Flush Door - 35mm thicknessProviding and fixing door shutter made out of factory-made and pressed laminated/veneer finish 35mm thick (without finish) flush door shutter, made of ISI marked non-decorative type flush door shutters conforming to IS:2202 (Part I), the core of block board construction with the frame of 1st class hardwood, pine filler and well matched commercial 3 ply veneer with vertical grains or cross bands and face veneers (IS 710 Grade) on both faces of shutters having laminates/veneer of an approved make, shade, finish (which would be paid separately) as approved by the Engineer-in-charge on both faces of the shutter fixed with phenol formaldehyde synthetic resin type adhesive conforming to IS 848, including providing and fixing 12mm thick peripheral external lipping made out of first class teak wood, on all edges of the door shutter with 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing with primer on all exposed faces of lipping including fixing shutters etc complete for all levels, all floors, all heights as per the issued drawings and as directed by the Engineer-in-charge. The rate shall be inclusive of flush door shutter, teak wood lipping with Paint/polish of approved make and specifications, necessary consumables ,provision of hardware, accessories, etc but excluding the cost of veneer/laminates, all required hardware like hinges, pivot, handle, tower bolts, locks etc and polishing on veneer, etc complete as per the issued drawing, design & direction of the Engineer-in-charge. The out-to-out area (one side) of the flush door shutter shall be measured for payment without considering any wastage. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. Cost of laminates/veneer shall be paid in relevant tender item. |
| 44 | Providing material and labour for fixing 1 mm thick Laminate sheet of any size, any shape, any color, any texture of approved make and as per approved sample (approved by architect) on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge. Actual laid area shall be measured and paid without considering any westage. Laminates and ply shall be factory pressed. |
| 45 | Providing material and labour for fixing vision panel made out of 5mm thick clear toughen glass of any shape any size in all type/ thickness of flush doors shutter. Glass shall be fixed with teak wood lipping (Lacquer polished of approved make and shade) on both side the door of required size as shown in drawing and direction of Engineer-In-Charge. Rate shall be includes the cost of cutting door, provision of glass with both side polished lipping, making good etc complete or all levels, all floors, all heights. The actual installed area of vision panel shall be measured for payment without considering any wastage. |
| 46 | Providing material and labour for fixing 6mm thick frame less mirror of approve make in any shape and sizes as per drawing. Mirror shall be fixed on 6mm thick cement bonded particle board (Bison panel) backing. Cement bonded particle board shall be fixed to wall with approved SS 304 fastener. All edges of glass shall be grinded (as required), cute corner and polished. Glass shall be fixed with silicon sealant/ 3M tape etc complete at all floors/ all levels/ all heights as directed by engineer in charge. Installed area of mirror shall be considered for payment without wastage. |
| 47 | Providing material and labour for Extra charges for machined Perforation/round holes of required dia and pattern in flush door shutter-plywood (finished with laminate or veneer)/ compact sheet of any thickness by machine or any means for without damaging the surrounding surface of the shutter air circulation for all floor, all height all level as per drawing and as directed by Engineer in charge. Edges of perforation shall be finished and sharpen. Out to out area of perforations on compact sheet/door shutter shall be considered for payment. |
| 48 | Floor SpringProviding and fixing double action hydraulic floor spring of an approved make with SS 304 cover plate having SS matt/ brush finish (with outer box) & adjustable concealed cast top pivot (two-piece), bottom strap, with back check, adjustable closing speed, and hold open function, with a minimum one-year guarantee for any type of door of specified capacity for all levels, all floors, and all heights. The rate shall be inclusive of cutting of floor neatly, fixing the floor spring, grouting, cleaning, polishing the floor and maintaining it in good working condition. In the case of an aluminium shutter, the bottom arm of the floor spring & the top pivot shall be firmly fixed to the aluminum members using required sized teak wood by making a rebate in the wood which is included in this item. Selection of floor spring shall be as per the size and weight of the door, as per the manufacturer's recommendation without any extra cost , and as directed by the Engineer-in-charge. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass execution. a) Floor spring for any type of door with cover plate and extended spindle to hide the floor spring cover plate. Closing force complying with EN 1154 2 - 5, as per the manufacturer's specifications, and/or compatible with the shutter weight. |
| 49 | Rack and pinion door closerProviding and fixing rack and pinion door closer of an approved make with a minimum one-year guarantee and approved finish for all levels, all floors, and all heights with a standard arm with hold open feature and with two independent closing valves and latching speed adjustable by arm, without mounting back plate, to any type of door, with screws for specified door width. All adjustment screws to be face fixed. The rate shall be inclusive of fixing using the template as per the manufacturer’s specifications and maintaining it in good working condition. The door closer shall conform to EN 1154 standard. Selection of door closer shall be as per the size and weight of the door, as per the manufacturer's recommendations, and as directed by the Engineer-in-charge. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass execution.a) Door closer conforming to EN 2-4 for any type of the door, as per the manufacturer's specifications, and/or compatible with the shutter weight. |
| 50 | Providing and fixing SS 304 butt hinges in matt stainless steel finish of specified size of an approved make for all levels, all floors, and all heights for any type of door, with required SS 304 screws, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before procurement and execution.b) 100 x 75 x 3 mm - With ball bearing |
| 51 | Providing and fixing SS 316 butt hinges in matt stainless steel finish of specified size of an approved make for all levels, all floors, and all heights for any type of door, with required SS 304 screws, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before procurement and execution.b) 100 x 64 x 2.5 mm - Without ball bearing |
| 52 | Mortise Deadlock for single/double door shutterProviding and fixing a set of mortise deadlock (without latch) for single/double shutter door, with 50mm backseat, 20mm square for end with 72 mm centers, including strike plate SS 304, and prepared for 60/70 mm length of standard Euro profile pin cylinder/Half pin cylinder as per DIN 18251-1, grade 2 of an approved make with both side key, one side key/one side knob, one side key/slot operation with pair of SS 304 matt finish escutcheons (keyhole plate) in any approved shape for any type of doors (wooden/ aluminium/ metal doors) with necessary SS 304 screws, etc complete as per the issued drawing and as directed by the Engineer-in-charge.The rate shall be for all heights, all floors, and all places. The lock shall have 3 number computerized keys. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 53 | Narrow stile deadlock for single/double door shutterProviding and fixing a set of narrow stile mortise deadlock (without latch) for single/double shutter door, with 25mm /35 mm set back including strike plate SS 304, and prepared for 60/70 mm length of standard Euro profile pin cylinder as per DIN 18251-1, grade 2 of an approved make with both side key, one side key/one side knob, one side key/slot operation with pair of SS 304 matt finish escutcheons (keyhole plate) in any approved shape for any type of doors with necessary SS 304 screws etc complete as per the issued drawing and as directed by the Engineer-in-charge.The rate shall be for all heights, all floors, and all places. The lock shall have 3 number computerized keys. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 54 | SS 304 Indicator boltProviding and fixing SS 304 material indicator bolt in matt finish of specified size for the Toilet door with a thumb turn inside & emergency release & indicator on the outside, of an approved make, for all levels, all floors, and all heights for any type of door, with required SS 304 screws and accessories of required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. Item shall not be used for doors for modular toilet cubical partition system. |
| 55 | SS 304 Grade Push-Pull handleProviding and fixing SS 304 grade push-pull pair of handles of size 200 mm long x 19mm dia in made out of satin (brush)/matt finish hollow pipe of minimum 1 mm thick of specified size, specified shape i.e. H-shape/D-shape/offset shape (C or D shape) (dent free at the bending point) for door, window, etc. of an approved make for all levels, all floors, and all heights for any type of door (wooden doors/ aluminium doors/ metal doors/glazed door), with required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. Elevation length shall be considered for length of handle. |
| 56 | SS 304 Grade Push-Pull handleProviding and fixing SS 304 grade push-pull pair of handles of size 300 mm long x 22 mm dia in made out of satin (brush)/matt finish hollow pipe of minimum 1 mm thick of specified size, specified shape i.e. H-shape/D-shape/offset shape (C or D shape) (dent free at the bending point) for door, window, etc. of an approved make for all levels, all floors, and all heights for any type of door (wooden doors/ aluminium doors/ metal doors/glazed door), with required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. Elevation length shall be considered for length of handle. |
| 57 | SS 304 Grade Push-Pull handleProviding and fixing SS 304 grade push-pull pair of handles of size 600 mm long x 32 mm dia made out of satin (brush)/matt finish hollow pipe of 1.5mm thick of specified size, specified shape i.e. H-shape/D-shape/offset shape (C or D shape) (dent free at the bending point) for door, window, etc. of an approved make for all levels, all floors, and all heights for any type of door (wooden doors/ aluminium doors/ metal doors/glazed door), with required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. Elevation length shall be considered for length of handle. |
| 58 | SS 304 Grade Push-Pull handleProviding and fixing SS 304 grade push-pull pair of handles of size 1200 mm long x 38 mm dia made out of satin (brush)/matt finish hollow pipe of 1.5mm thick of specified size, specified shape i.e. H-shape/D-shape/offset shape (C or D shape) (dent free at the bending point) for door, window, etc. of an approved make for all levels, all floors, and all heights for any type of door (wooden doors/ aluminium doors/ metal doors/glazed door), with required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. Elevation length shall be considered for length of handle. |
| 59 | SS 304 handleProviding and fixing SS 304 grade 150mm long D shape hollow tube handle in matt finish of specified size, specified shape for door, window, etc. of an approved make with both end bracket with necessary screws etc. SS 304 for all levels, all floors, and all heights for any type of door, with required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass execution. |
| 60 | Providing material and labour for fixing 25mm diameter (1.5mm thick) SS 316 satin (brush) finish Disabled Grab Rails/ handle of 600mm long of approved make with necessary SS 304 grade screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass execution. |
| 61 | SS 304 Tower boltProviding and fixing SS 304 grade 450 mm height tower bolts (barrel type with minimum rod size shall be 10mm) in brush finish/matt finish of specified size, and specified shape (with or without flap) for doors, windows, transom, etc. of an approved make for all levels, all floors, and all heights for any type of door, with required SS 304 screws and accessories of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 62 | SS 304 Tower boltProviding and fixing SS 304 grade 250 mm height tower bolts (barrel type with minimum rod size shall be 10mm) in brush finish/matt finish of specified size, and specified shape (with or without flap) for doors, windows, transom, etc. of an approved make for all levels, all floors, and all heights for any type of door, with required SS 304 screws and accessories of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 63 | SS 304 Flush Tower bolt(Concealed tower bolt for double door shutter)Providing and fixing SS 304 grade flush tower bolts with extended rod of 600 mm length and 19mm projecting bolt in brush finish/matt finish of specified size, and specified shape for doors, windows, transom, etc. of an approved make for all levels, all floors, and all heights for any type of door, with required SS 304 screws and accessories of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 64 | SS 304 baby latchProviding and fixing SS 304, 100 mm long baby latch in matt finish including required bracket, of an approved make for all levels, all floors, and all heights for any type of door, with required SS 304 screws and accessories of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 65 | Providing material and labour for fixing SS 304 brush finish solid Door Stopper with magnet, fixed type, wall mounted (square/ round) of approved make with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 66 | Providing material and labour for fixing SS 304 grade brush finish solid Door bufer with pvc base, wall mounted (square/ round) of approved make with necessary screws etc. complete as approved by Engineer-in-charge in Charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 67 | Adjustable sliding friction windows stayProviding and fixing stainless steel (SS 304 grade) adjustable sliding friction window stays of size 355 X 19 mm (for easy cleaning) for aluminum top hung or side hung door and window shutter in the approved finish, color, and shade of required size and capacity of an approved make, for internal/external shutter as per the approved sample with necessary SS 304 screws, handle, connector, extension, nib, nib holder, counter plate, fork, pawl, polyamide strip, connection pin, rod terminal, locking point, striker and corner transmission etc. complete for all levels, all floors, and all heights as directed by the Engineer-in-charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before procurement and execution. |
| 68 | Providing and fixing powder coated single point lock with mortise handle (without lock) of approved make with heavy gear mechanism of required capacity including all required accessories like handle, fork, connector, extensior, polyamide, locking point, corner transmission and striker etc as per approved manufacturer recomendatation for aluminium casement door and window (top hung or side hung) with necessary screws etc complete as directed by engineer in charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 69 | Providing material and labour for fixing powder coated two point lock with mortise handle (without lock) of approved make with heavy gear mechanism of required capacity including all required accessories like handle, fork, connector, extensior, polyamide, locking point, corner transmission and striker etc as per approved manufacturer recomendatation for aluminium casement door and window (top hung or side hung) with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 70 | Providing material and labour for fixing powder coated inbuilt flush handle (without lock) of approved make of required capacity including all required accessories like nib, counter plate etc as per approved manufacturer recomendatation for aluminium sliding window with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 71 | Providing material and labour for fixing powder coated multi point lock with mortise handle (without lock) of approved make of required capacity with heavy gear mechanism including all required accessories like nib, nib holder, counter plate, fork, pawl, polyamide strip, dummy handle etc as per approved manufacturer recomendatation for aluminium sliding doors and window with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 72 | Providing material and labour for fixing adjustable/ fixed Teflon roller bearing set with reinforced nylon casing of approved make (twin or single wheel according to weight and size) for sliding window/door as per drawing etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. The rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before mass procurement and execution. |
| 73 | Providing material and labour for fixing of Hollow metal fire rated doors of approved make and shade as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI against Test Schedule Ref No FR/0490 or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single & double leaf doors and Hardware should pass European certificate \\"CE\\" of conformity / UL with required fire ratings. Any deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer subject to architect’s approval and should be ISO Certified company.Providing material and labour for fixing Fire rated Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and SS 304 anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening. Frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of anchore fastner and rubber silencer for all floor all level but excluding of SS ball bearing hinges). |
| 74 | Providing material and labour for fixing Fire rated Door shutter shall be 46mm thick fully flush double skin door with or without vision lite. Door shutter shall be manufactured from 1.2mm (18guage) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beading and screws from inside. EPDM open cell sponge seal and bottom seal shall be provided at periphery and bottom of shutter as per manufacturer's specificatipon. Door shutter shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of all type seal for all floor all level but excluding of vision panel and all type of hardware. |
| 75 | Providing material and labour for fixing 120 min fire rated SS 304 Ball Bearing Butt Hinges 100mm x 75mm x 3 mm CE marked for fire rated metal door of approved make with necessary screws etc. complete as recommended by manufacturer for all floor all height and as directed by Engineer in Charge. |
| 76 | Providing material and labour for fixing Fire rated (120 minutes) Rack and pinion non-handed door closer of approved make EN size 2-4, with back check and standard arm with two independent closing valves and latching speed adjustable by arm. All adjustment screws face fixed with slide plate. The door closer shall be with Silver finish cover. The door closer shall conform to EN 1154 standards and CE marked with necessary fittings etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge. |
| 77 | Providing and fixing 120 min fire rated Mortise sash lock of Dorma 281a or equivalent with 70 mm Cylinder Thumb turn with Lever TH 126 CE marked for fire rated metal door of Dorma or equivalent with necessary fittings etc. complete as recommended by manufacturer and as directed by Engineer in Charge. |
| 78 | Providing material and labour for fixing 1 point panic device in Contur design, carry bar for single door for fire and smoke check doors, with steel latch, security anti thrust latch for door widths upto 1300mm, consisting of 2102F, 2105 in silver finish of approved make. As per EN 1125, CE marked etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge. |
| 79 | Providing material and labour for fixing 1 point panic device in Contur design on active leaf and 2 point modular on inactive leaf, carry bar for rebated double door of approved make for fire and smoke check doors, with steel latch, security anti thrust latch consisting of all required accessories in silver finish. As per EN 1125, CE marked with necessary fittings etc. complete for all floor all height as recommended by manufacturer and as directed by Engineer in Charge. |
| 80 | Providing material and labour for fixing External trim with design lever handle of approved make suiting the panic bar for fire and smoke check doors for max. 60mm thick door prepared for half euro profile cylinder and in Silver finish with necessary fittings etc. complete for all floor all height as recommended by manufacturer and as directed by Engineer in Charge. |
| 81 | Providing and fixing of Non Fire rated Hollow metal door of approved make and shade at all levels from ISO 9001-2000 certified Manufacturer. All hollow metal general doors with or without vision panel. Pressed Galvanized steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Double rebate profile of size 143 x 57 mm made out of 1.20mm thick galvanized steel sheet (18 gauge). Frames should be Mitered and field assembled with self tabs. Frames should be fixed with back plate bracket and anchor fasteners of approved size and make for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonary opening.Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 gauge) minimum thick galvanized steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be as per joinery details with a screw on glass beading on the inside. The glass should be 5mm clear toughened glass. Shutter shall be fixed to frame with SS 304 Ball Bearing Butt Hinges of size 100mm x 75mm x 3 mm (no of hinge as suggested by engineer in charge).All door shutter and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate shall be include supply and installation of door i.e frame, anchor fastener, shutter with vision lite, hinge but exclude the cost of hardware (other than hinge) etc complete as directed by engineer in charge. Out to out area of door with frame shall be measured for payment. |
| 82 | Providing material and labour for process charges of Frosting the glass (any thickness of glass) as per drawing and as directed by engineer in charge. Rate shall be for only for extra cost of Forsting on Glass for all floor, all height all level. |
| 83 | Sec.7.0 Plastering & Pointing worksProviding material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for all floor, all level, all height (including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 84 | Providing material and labour for laying 15mm to 18mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for for all floor, all level, all height (including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 85 | Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for all floor, all level, all height (including all basement) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 86 | Providing material and labour for laying 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 87 | Providing material and labour for fixing G.I. hexagonal chickenmesh of size 20mm x 20mm of 22 gauge at junction of concrete and brick work or between different materials after making \\"V\\" grove between two different material surface and filled with rich cement mortar and @ 100mm on each side of surfaces including necessary \\"U\\" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge. |
| 88 | Sec.8.0 Waterproofing worksProviding material and labour for laying average 18mm thick double coat (water proof) smooth/ wired finish cement plaster on sides of masonry work/ block wall/ RCC wall, 12 mm thk first coat in CM 1:3 (1 cement : 3 coarse sand) by spraying , second coat of 6 mm of CM 1:3 (1 cement : 3 fine sand) and mixing Integral waterproofing liquid admixture for mortar in recommended proportions in both coats, finishing the surface wired finish/ smooth finish with a floating coat of neat cement slurry at 2.75 Kg/ sqm to receive the tiles for all floors, all shapes and all height including hacking to RCC surface, scaffolding, curing etc. complete for all floor, all height as directed by engineer-in-charge. Cement slurry admixed with Integral waterproofing liquid admixture for mortar in recommended proportions is to be applied before each coat and final finishing coat. |
| 89 | Providing material and labour for laying average 50 mm thick IPS, water proof cement concrete flooring in 1:2:4 (1 Cement : 2 Sand : 4 Graded Aggregate 10mm Nominal size) to RCC under ground tanks at all heights in line, level and gradient including mixing water proofing compound in recommended proportions suggested by manufacturer as approved by Engineer-in-charge and leaving the surface rough wired finish to receive any type of flooring / smooth finish etc complete for all floor all height as directed by engineer in charge. |
| 90 | Providing material and labour for laying integral cement based water proofing treatment (India type brick bat) including preparation of surface as required for treatment of roofs, balconies, terraces etc with average thickness of 120 mm and minimum thickness at khurra as 65 mm and consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with wired finish to receive china mosaic flooring.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge for all height all level. |
| 91 | Toilet waterproofingProviding material and labour for carrying out waterproofing treatment to sound concrete surface of toilets, sunken slabs, corridors, wet areas etc. after proper surface preparation to remove loose dust, dirt etc., repairing of cracks (if any) using polymer modified mortar, carry out cementitious injection grouting at leakage points modified with Plasticized Expandive Grout Admixture @ 225 gms per bag of cement, carry out 50 mm thick cement mortar (1:3) vatta/ corner modified with Styrene Butadine Polymer bonding agentat dosage of 2.5 Ltr per 50kg cement, Pre-dampening concrete surface, mixing and application of two coats of Elastomeric Polymer modified cementitious waterproofing coating by incorporating alkali resistance 45 gsm glass fibremesh between 1st and 2nd coat using suitable brush or roller as per coverage etc. complete for all floor al height all level as per manufacturer’s specification and as directed by engineer in charge.Cured Polymer modified cementitious waterproofing coating shall comply with ASTM D4060, ASTM D4541, ASTM D638,ASTM C836 and possess below properties: Mixed density : 1.68 g/cc, Adhesion to concrete-> 1 N/mm2, Non-toxic, Static crack accommodation-1 mmWater proofing system shall be executed by only approved applicator of approved brand and under strictly supervision of technical fellow of manufacturer. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma. |
| 92 | Hole Packing treatment on service line Providing material and labour for applying total packing treatment on any type of pipes comes into water proofing area for all floor, all height as directed by engineer in charge as follows :Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of styrene- butadiene based polymer coating using Styrene Butadine Polymer bonding agentto enhance adhesion between the packing material and other surfaces. Packing the gap using non shrink cement polymer based grout using Non-shrink cementitious grout upto the surface of the bore whilst the bonding agent is in tacky state before application of water proofing treatment. Treatment shall be executed by same agency with same manufacturer's product. Warranty includes in water proofing item. |
| 93 | Providing material and labour for applying hydrophilic crystalline based waterproofing for concrete walls, raft (basement and under ground water tank) with system In two coat application. The application to be done from + ve (positive) side on a wet open pore green concrete surface at coverage of 0.8 to 1 Kg/Smt as per manufacturer specification. It should be hydrophilic in nature, should be able to grow crystals year after year to seal microcracks.The product should confirm to DIN 1048 part 5 and should provide in depth crystallization. The product technology should be CPWD and EIL approved. Application should be done on wet surface after 3-6 hours of casting of concrete. The material and application warranty to be given by manufacturer’s authorized distributor/ applicator on prescribed format. Rate shall be inclusive of construction joint treatment, crack repair, patch repair, grouting, including cost of scafolding for all height all level as directed by engineer in charge. |
| 94 | Providing material and labour for applying of Swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge for all floor, all height all level. The product performance shall carry guaranteed for 10 years against any leakage. |
| 95 | Providing and applying 400 microns thick coal tar extended epoxy resin coating to sound concrete surface after carry out surface preparation to remove loose concrete, curing compound or any other foreign material, mixing base and hardener component of Coal tar extended epoxy resin coating, apply first coat at 200 microns DFT using suitable brush or roller, allow the first coat to dry for 6 hrs at 35°C followed by application of application of second coat at 200 microns DFT in perpendicular direction to first coat etc. complete as per manufacturer’s specification for all level all depth as directed by engineer incharge.Coal tar extended epoxy resin coating shall be having 100% solid contents by weight, specific gravity - 1.54 at 27°C, Curing efficiency – 93 % (BS 7542), Water absorption <0.01 % (ASTM D 570), Bond Strength: min 1 N/mm2 (BS 1881 Pt 207), Water Permeability: nil at @ 2 bars pressure over 3 months, Salt spray test: nil @ 200 microns DFT over 1000 hrs (BS 1881 Pt. 124:1988), Impact Resistance: passed (BS 3900 Pt E3) & Chemical resistance checked in accordance with ASTM D 453 |
| 96 | Providing and mixing Migratory Corrosion Admixture POLYALK CP 293 having Specific Gravity 1.01 to 1.04, pH value (Minimum 9.50) shall be alkaline in nature and having bipolar concrete penetrating corrosion inhibiting properties, inhabitor shall be non-nitrite based & have the ability to provide corrosion protection to both anodic and cathodic sites on the steel surface, inhibitor-steel complex shall formed polydentate complexes, having more than one bond with steel per molecule of inhibitor, with steel surface to promote proper film formation with enhenced bond to steel, inhibiting the electro-chemical corrosion reaction, inhibitor shall not have any adverse effect on concrete compressive strength, inhibitor shall have a corrosion rate of zero coulombs per ASTM-G109-2005, admixture shall be conforming to IS 9103 and in liquid form at the rate of 3Kg per one cubic meter volume of concrete admixture shall be added to the water, during mixing of cement, sand & aggregates and at the same rate admixture shall be added in case of Ready Mix Concrete at plant site, mixing of admixture during mixing of cement, sand and aggregates OR at work site the admixture shall be added in Concrete Transit Mixer before pumping / placing of concrete etc. complete. |
| 97 | Sec.9.0 Flooring worksProviding material and labour for laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Sample and mockup shall be approvd before procurement of material. The actual laid area of the tiles shall be measured for payment without considering any wastage. |
| 98 | Providing material and labour for laying Ceramic tiles 6mm thick in skrting, risers of steps and dedo laid on plastered wall with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Sample and mockup shall be approved before procurement of material. The actual laid area of the tiles shall be measured for payment without considering any wastage. |
| 99 | Providing material and labour for laying average 25mm thick machine cut semi mirror polished Green Kota stone slab of size upto 600mm in flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge. Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approved before procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 100 | Providing material and labour for laying 8 to 10 mm thick Kota stone slabs in upto 100mm high skirting, (flush with plaster) laid on average 10 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including providing 10mm wide grove between skirting and plaster, rubbing and polishing complete as directed by Engineer In charge. Sample shall be approved before execution. Kota stone shall be in uniform shade of reuired size. Sample and mockup shall be approvd procurement of material. Shade of skirting must be match with flooring stone. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 101 | Providing material and labour for laying average 40 mm thick machine cut polished Green kota stone slab of size upto 0.9mt length with uniform thickness double side polished at edges for parapeet wall coping, window sills, over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry or stone fixing adhesive and mechanical fastner of approved make including rounding of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be pencil sharped and in even thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 102 | Providing material and labour for laying average 25 mm thick machine cut polished Green kota stone slab of size upto 2.1mt length with uniform thickness for tread, window jambs & sills, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including pencil sharped exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be pencil sharped and in even thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Sample and mockup shall be approvd before procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 103 | Providing material and labour for laying average 25 mm thick machine cut polished Green kota stone slab of size upto 2.1mt length for riser of stair over 12 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 104 | Providing material and labour for laying average 30 mm thick machine cut both side polished Green kota stone slab of size upto 1.5mt length for shelves, counter, partition in walls, self, etc as per drawing of stair over 12 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. Sample shall be approved before execution. Sample and mockup shall be approvd procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 105 | Providing material and labour for laying machined cut average 25mm thick River wash finish Green Kotah stone of size upto 600mm of approved quality, selected and sorted for uniform color & texture, in floor, otta, tread, riser, ramp etc. of specified size as per design normal pattern (straight or staggered joint with square or rectangular shaped stone) and drawings. Kota stone is to be laid over cement mortar 1:6 bedding of average 20 mm thickness with keeping groove (upto 10mm wide), filling the groove with cement mortar in 1:2 (1 cement : 2 sand) with matching pigment, in 5mm less thickness of kota stone, and finishing including curing and cleaning with wire brush to remove excess cement on the sides of stone, chemphering of exposed edges having polishing up to the satisfaction of the Architect & engineer in charge etc. complete for all places/ all levels/ all heights. Sample and mockup shall be approvd procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 106 | Providing material and labour for laying machined cut average 25mm thick River wash finish Green Kotah stone of size 1500mm of approved quality, selected and sorted for uniform color & texture, in floor, otta, tread, riser, ramp etc. of specified size as per design normal pattern (straight or staggered joint with square or rectangular shaped stone) and drawings. Kota stone is to be laid over cement mortar 1:6 bedding of average 20 mm thickness with keeping groove (upto 10mm wide), filling the groove with cement mortar in 1:2 (1 cement : 2 sand) with matching pigment, in 5mm less thickness of kota stone, and finishing including curing and cleaning with wire brush to remove excess cement on the sides of stone, pencil sharped exposed edges having polishing up to the satisfaction of the Architect & engineer in charge etc. complete for all places/ all levels/ all heights. Sample and mockup shall be approvd procurement of material. The actual laid area of the Kota stone shall be measured for payment without considering any wastage. |
| 107 | Providing material and labour for laying cement concrete pavement/floor bedding (of any thickness) with 1:2:4 (1-cement : 2-coarse sand : 4-stone aggregate 20mm nominal size) including curing, finishing with floating coat of neat cement complete at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. |
| 108 | Providing material and labour for laying 8 to 10mm thick full body vitrified tile of size upto 600mm of any shade, any finish (glossy, matt, satin or anti skid finsh) of approved make in flooring and Skirting laid over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including provision of groove, grouting of joints, finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Grouting shall be paid in relevant tender item. Sample and mockup shall be approvd procurement of material. Actual laid area of tile shall be measured and paid. |
| 109 | Providing material and labour for laying 8 to 10mm thick, double charged Vitrified tiles of size upto 600mm (of any shade glossy, matt or satin finsh) of approved make, shade and finish as approved by Architect/ EIC for all floors/ any height/ any levels etc in wall tile, dado, risers of steps, jambs as per drawings. Wall tile is to be fixed over 10 to 12 mm thick smooth finish plaster in cement mortar 1:3 (1 cement : 3 coarse sand) and fixed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including provision of groove, grouting of joints, finishing of joints, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. Grouting and backing coat plaster shall be paid in relevant tender item. Sample and mockup shall be approvd procurement of material. |
| 110 | Extra for providing material and labour for Grouting the joints of any type of flooring tiles of Size upto 600mm having joints of 3mm / 4mm width and in full depth, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade and approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and finishing complete as per direction of Engineer-in-charge. |
| 111 | Providing material and labour for laying approved quality average 18mm thick mirror polished Granite stone of approved shade in floor, otta in any pattern etc size upto 600mm including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as per satisfaction of Architect and as directed by Engineer in charge at all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.) Sample and mockup shall be approvd procurement of material. |
| 112 | Providing material and labour for laying 8 to 10 mm thick machine cut polished Granite stone slabs of same shade as flooring and as per approved sample in skirting upto 100 mm high as per drawing (flush with plaster) laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including providing 10mm wide grove between skirting and plaster, rubbing and finishing complete. Shade of skirting must be match with flooring stone. |
| 113 | Providing material and labour for laying approved quality average 18mm thick River wash finish Granite of required size, approved shade in floor, otta, skirting, pavement, plaza or similar in any pattern including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, curing, finishing, cleaning etc complete as directed by EIC. Sample shall be approved before execution. Laying patern shall be as per drawing and instruction of EIC for all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.) |
| 114 | Providing material and labour for fixing average 18mm thick mirror polish Granite of uniform size and colour for treads and risers of stair, sill, jams of window, coping etc size 1200mm to 2500 mm long, of approved shade, including necessary machine - cut edges (uniform thickness) rounded edges, as per design in required sizes and shapes over 20 mm (average) thick bedding of cement mortar 1:6 (1 cement: 6 coarse sand) laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC etc complete for all floors any heights, any lead and lift as per approved sample by Architect, drawings and instruction of EIC. The rate includes machine cut edges of uniform thickness, champhering and mirror polishing of edges and maintaing upto hand over the project. |
| 115 | Providing material and labour for fixing machine cut average 18mm thick mirror polished Granite stone slab of approved shade as per approved sample for dado, cladding, skirting etc., in required design and pattern as per drawing, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, or fixed with stone fixing adhesive as per manufacturer's specifications including mirror polishing, pencil sharped edges, edge polishing, rubbing, curing, finishing, necessary scaffolding, maintaining upto handling over the project etc complete for all floors any heights, any lead and lift etc complete as directed by Engineer Incharge. Baking coat plaster for dado shall be paid in relevant tender item. Shade of skirting must be match with flooring stone. |
| 116 | Providing material and labour for fixing both side average 18mm thick mirror polished Granite stone slab as per sample approved by Engineer in charge with edges rounded and mirror polished, of required size fixed as urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) as per drawing and as per direction of Engineer-in-charge. All expose edges shall be champhered and mirror polished. Rate shall be inclusive of chasing, cutting, edge champhering, edge polishing, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge. |
| 117 | Providing material and labour for laying sandwich platform comprising of a) Sandwich of 18 mm thick single side polish Granite of approved size, shade and sample on top and 30 mm thick polished kota in bottom with 25mm thick cement mortar (1:4) in between b) At centre vertical sandwich supports of 30 mm thick two kota stone on sides and 20mm CM (1:4) in between and at both end walls vertical supports of 18 mm thick double side granite. c) 75 mm raised platform at bottom with kota on top and 50mm CM (1:4) at bottom, kota stone skirting as per design and approved sample. The rate includes rounding, champhering and mirror polishing of edges, facias of granite, MS support including necessary bonding adhesive (if required). Rate shall be also inclusive of curing, making holes & cutouts for sink, wash basin, Piller tap/ Bib tap but excluding the cost of MS work, plumbing fixtures ans sink. at all floors all height etc complete as directed by Engineer Incharge. (Only plan area shall be measured & paid for). Rate shall be included all kota & granite mentioned in above. |
| 118 | Providing material and labour for laying machine cut single polished 18mm thick Jesalmer yellow stone in flooring, band etc as per design and drawing over 20 mm thick cement mortar 1:3 and pointing in joints in white cement with matching pigment, curing etc. complete. The rate should also include for polishing with different grades of emery, daily moping with water, buffing, finishing at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. |
| 119 | Providing material and labour for roughened strip 2.5 cm wide to form antiskid surface on treads of stairs in any type of stone including forming straight deep curved gishi (groove), 6 mm wide & 4 mm deep on two sides of the roughened area, chiseling, polishing the edges, sides and bottom of gishi etc. complete as per sample approved for all floor, all height. Only one time length of tread of stair shall be measured for payment. |
| 120 | China Mosaic flooringProviding & laying china mosaic flooring for plain and curved surfaces, comprising of 20 to 25 mm size broken white/colour pieces of ceramic/glazed tiles laid over 12 to 15mm thick cement mortar, 1:6 (1 cement: 4 coarse sand) bedding including applying cement slurry at the rate of 2.75 kg per sqm on plain or sloped surfaces with joints not exceeding 5 mm, including filling the gaps with white cement mixture & mixing with synthetic polyester fiber, triangular in shape having specific gravity of 1.34 to 1.40, cross-section size ranging from 10 to 40 micron & length up to 6mm, mixing fiber @ 125 grams per 50kg of cement in cement mortar, including providing and mixing waterproofing material in mortar @ 1 kg per 50 kg of cement, all complete as per the direction of the Engineer-in-charge. The flooring shall be tampered with a wooden rammer not exceeding 2 Kg in weight to bring the mortar up to the surface, including rounding of the junctions and extending them up to 150 mm. along the parapet wall. The rate shall include bands if a different colour is used, any pattern or design as per drawing and direction, making vata/ fillet, curing, cleaning with water and oxalic acid, etc. complete. Only the Plan area shall be measured for payment. |
| 121 | Providing material and labour for laying Cement Mortar for additional floor bedding in Cement Mortar 1:6 (1-Cement: 6 - coarse sand) including curing etc for all floor, all level all height. Additional bedding thickness shall be as per drawing and as directed by engineer in charge. |
| 122 | Sec.10.0 Structural steel worksProviding material and labour for, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars , Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per approved shop drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat of epoxy primer and 2 coat of PU paint of approved make shade of paint over all the surfaces of the steel sections. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by engineer in charge. (Standard measurements will be paid for as actual cut length used at site) |
| 123 | Providing and fixing in position, interlocking rolling shutter of approved make, made of 18 gauge, 75mm wide cold rolled GI lath interlocked, including top cover (20 gauge), spring, axles (specially designed shaft), guide rails (10 gauge), tees, iron pulleys, ball bearings, handles, arrangement for inside and outside locking arrangement, with Mechanical Type (Gear Arrangement), holding down bolts embedded in CC 1:2:4 / anchor fastener of HILTI or equivalent including 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of approved make and shade over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for width and 450mm on top for drum height.) |
| 124 | Providing and fixing stainless steel (Grade 316) Railing and baluster system of approved make stair railing, hand rail, bump rail, guard rail, with knock down system made of Hollow or solid secion i.e. tubes, square, flat, plates, bar etc with base plate Cover cap, finishing accessories, infilled holding brackets, fixing accessories etc. for any type of design, shape (plain/ curvature), size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 316 grade anchor fastner of required size and as per fixing position of approved make. No Welding OR Fabrication shall be allowed at site. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Sample shall be approved before execution. Contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Architact and Engineer in charge. Contractor shall protact railing system uptill handeling over the project. |
| 125 | SS water troughProviding material and labour for, Fabricating and fixing SS 316 grade water trough of size 300mm x 450mm with 300mm high SS sheet cladding (dedo) made out of 1.2mm thick sheet and required size of angle, flat etc in satin/ brush finish including supporting fittings made out of SS 316 grade solid rods, flats, anges, compatible SS anchor fastener (mechanical or chemical) as per manufacturer's specifications, SS supporting arrangement, latth work, argon arc welding bending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour and wastage for all floor, all height, all level. Water trough shall be measured in Rmt. Installed length shall be measered. Contractor shall prepare shop drawing based on concept drawing ant get approved before execution. |
| 126 | Extra for providing material and labour for Hot dip galvanizing work confirming to IS 4759/ 2629/ 2633 with zinc of 610 GSM thickness on Cable tray, Railing, Handrail, facade framing, supports for mechanical equipments, garbage box, Street furniture and similar works etc made from solid flat, bar, RHS, SHS, tubular hollow sections etc. as per the drawing and as instructed by engineer in charge. The rate shall include preparing the surface by shot blasting/ acid washing prior to hot deep galvanizing, labor, tools, machinery etc complete (Sample to be approved). The weight of steel sections before galvanization shall be measured for payment. The cost of steel sections shall be paid for separately under relevant item. |
| 127 | Sec.11.0 Painting worksWhite washing with lime on wall and ceiling surface (two coats) to give an even shade including thoroughly booming the surface to remove all dirt, dust; mortar drops and other foreign matter etc complete for all floors, all heights, all level as directed by Engineer Incharge. |
| 128 | Providing material and labour for applying Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall and ceiling surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth etc complete for all floors, all heights, all level as directed by Engineer Incharge. |
| 129 | Providing material and labour for applying (Synthetic) Plastic emulsion paint (minimum 2 coats) having VOC (Volatile Organic Compound) content less than 50 gm/ltr on newly/ existing dry interior plastered surface including ceiling, roof etc. at all heights/ all levels/ all surfaces to give an even shade on prepared (putty and primer work) surfcae. Sample to be approved before starting of the work by Architect/ EIC. Rate shall be inclusive of the cost of scafolding but excluding the cost of primer and putty work. |
| 130 | Providing material and labour for applying required coats (min two coats) of white cement based putty after thoughly brushing the surfaces free from mortar dropping and other foreign matter. Preparing the surface even and sand papered smooth, after applying every coat of putty complete. Priming coat of alkali resistant cement primer (water or solvent based) is to be applied over prepared smooth surface (undulation free) etc. complete as directed by engineer-in-charge. After application of putty work, wall surface shall be in levelled and without undulation. The rate shall include the cost of filler for filling the cracks on surface, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding etc. as directed by engineer in charge. |
| 131 | Providing material and labour for applying Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete for all floors, all heights, all level as directed by Engineer Incharge. Product to be |
| 132 | Providing material and labour for Wall painting with anti microbial premium quality acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ liter of approved make and shade, with additional teflon surface protection, anti microbial formula & stain resistant, including applying additional coats wherever required to achieve even shade and colour over acrylic wall putty and one priming of approved make for all floor all height etc complete asdirected by engineer in charge. |
| 133 | Providing material and labour for applying external finish of average 2 to 2.5mm thick acrylic polymer based texture and pattern with standard tool and applicator as specified by manufacturer on exterior surfaces at all heights including scaffolding to give even shades including thoroughly brushing the surfaces free from mortar droping and other foreign matter and sand paper smoothed as per the manufacture specifications etc. complete for all floor, all height, all level and up to the satisfaction of Engineer in-charge/ Architect. The rate includes making of grooves, pattas and finishing as directed by Engineer in charge. Paint shall be measured and paid in seperate tender item. (Item should be executed by approved applicator only.) |
| 134 | Sec.12.0 Roofing worksProviding material and labour for fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per BS 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture of size 595 x 595 x 15 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24x28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200x600mm and secondary cross ’T’ to be interlocked at middle of the 1200X600mm panel to form grid of size 600x600mm resting on periphery walls/ partitions on a perimeter wall with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, as per specifications, drawings and as directed by engineer-in-charge. |
| 135 | Providing & Fixing M/F Suspended 12.5mm Plain Gypsum Board which includes GI Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. GI Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the GI soffit clit with Soffit Cleat and Rawl Plug creating 1220mm x 1220mm grid. GI Intermediate channel is fixed to the GI Ceiling Angle with 2 Nos of 4.2x13 GI metal to metal screw. The GI Ceiling Section is then fixed to the GI Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. All framing and grid section shall be GI (as per IS 513) having yeild strength 300 mpa and galvanized finish of 150 GSM as per IS 277. Single layer of 12.5mm tapered edge Plain Gypsum Board (Confirming to IS 2095-Part-I, 2011) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing Compound & Joint Paper tape. The contractor should prepare shop drawings based on the concept drawing and get it approved by the Engineer-in-charge. After approval of drawings, the contractor shall prepare the sample based on the drawing and get it approved by the Engineer-in-Charge before execution. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, making grooves between wall & board or as per drawing for all floor, all level, all height etc as directed by Engineer in charge. Area of cutouts shall not be deducted and no extra payment shall be considered for additional sections provided. Only plan area shall be considered for payment. |
| 136 | Metal False Ceiling:Providing & Fixing true horizontal level suspended ceiling comprising of GI Clip-in with double pip self-leveling consisting of 600x600mm clip in tiles of galvanized steel in 0.5 mm thickness with bevel edge in pre-coated Global white color with Light Reflectance > 75% and fire performance of Class 0/Class 1 as per BS 476 Part 6 & 7 standards. Warranty Certificate of 10 Years and Test Reports for Fire rating shall be provided by Vendor.Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit using 6mm dia threaded rod connecting C- channel hanger at 1200mm C/C and anchor fastener. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm Main carriers (spring tee bars) shall be spaced at 600mm centers in a direction perpendicular to the C-channels and secured at every intersection with C channel using a hanger. Use connector to splice two pieces of main carriers. Tiles should be clipped in between two carriers (spring tee bars) from below. Perimeter trims to be of wall angles of size 3000x19x32mm in white color secured to walls at 450mm maximum centers. Installation to be carried out by trained Installation team and as per recommended procedure of approved manufacturer.Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, scafolding, making grooves between wall & board or as per drawing etc complete for all level, all height, all floor amd as directed by Engineer in charge. Only plan area shall be considered for payment. |
| 137 | Perforated Gypsum tile acoustic false ceiling : Supplying material labour for fixing of Suspended ceiling system with 12.5mm thick glass fibre perforated gypsum plaster board/ tile of any size having any type of edges and any shape, any size, any pattern perforation and GI suspended framing system. This includes ribbed frame Perimeter Channel fixed to brick wall/partition with the help of nylon sleeves and screws at 600mm centres along the perimeter of ceiling. Then suspending ribbed section used as intermediate channel from the soffit at 1220mm centres with Ceiling Angle fixed to RCC Slab with Soffit Cleat and steel expansion Fasteners @ 600mm Centres respectively. Ultra frame ribbed Ceiling Section are then fixed to Intermediate channel with the help of four point connecting clip (0.8mm thick) and in perpendicular direction to the intermediate channel at 600mm centres. All framing and grid section shall be GI (as per IS 513) having yeild strength 300 mpa and galvanized finish of 150 GSM as per IS 277. 12.5mm thick glass fibre perforated gypsum plasterboards/ tile of any size having any shape, any size, perforation of any pattern is screw fixed with 25mm long Drywall screws at 230 mm centres. 50mm thk 24kg/m3 glasswool should be placed between the frame and perforated board with the help of Glasswool tissue bag. The screw fixing of gypsum plasterboards to the metal framing at the periphery, openings and cut edges should be at 150mm centres. Finally square or tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape and two coats of Drywall Top Coat as per the drawing & approved sample. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, scafolding, making grooves between wall & board or as per drawing etc complete for all level, all height, all floor amd as directed by Engineer in charge. Only plan area shall be considered for payment. |
| 138 | Providing material and labour for Fixing of Mineral Fibre Suspended Ceiling System with Bevelled Tegular edge hygienic tile with grove (Bioguard) with 15mm Exposed grid. The tiles should have Humidity Resistance (RH) of 95%, Light Reflectance 90%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600x600 x minimum 15mm with Anti Microbial coating on the face of the tile. The tile shall be laid on any type of grid system (Silhouette/ superfine/ select grid system of Armstrong) with 15mm white flanges incorporating a 6mm central reveal in white/ black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2 & minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with suspension system of same make. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. SUSPENSION SYSTEM accessories shall be of same make and consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length, thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner.Contractor shall provide 0 year warranty against Tile & Grid system used together. Installation shall be done by approved applicatior of manufacturer all floors/ all heights/ all levels including scaffolding etc as directed by Engineer in charge. |
| 139 | Providing material and labour for fixing fabricated metal single shutter/ double shutter trap door made from 0.8 mm MS sheet, Inner Frame - 1.5 mm, Outer Frame - 2mm MS sheet and finished with powder coating of approved shade/ enamel/ acrylic paint (primer + 3 coats of paint) of approved make and shade. Door shall be installed on existing false ceiling framing with extra MS suspender with necessary hardware like allen key lock, hinges/ pivot, safety chain etc complete as directed by engineer in charge. Rate shall be inclusive for providing, loading/ unloading, transporting and installation at all floor all height but excluding the cost of extra suspender for installing the trap door. Area of trap door with frame shall be measured for payment. |
| 140 | Mineral wool insulationProviding material and labour for installing 50mm thick 48kg/cum density mineral wool (pre-wrapped) in the wall panelling and over acoustic false ceiling as per required application, for all floor, all height, all level as per drawing and as directed by engineer in charge. |
| 141 | Providing and fixing of 16 mm thick Multicell UV protected Polycarbonate Panel System with 5 cells and 6 walls structure over structural steel / MS purlins per approved colour/shade for plain or curved (dome type) roofing work. Co-extruded UV protected panels shall have width of 900mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Welding or gluing up of standing seam is not acceptable. Panels shall be fixed on purlins with Stainless steel retention clips and connectors. Snap-on connectors to interlock the panels shall have a grip-lock single tooth locking mechanism to ensure maximum uplift capability. Panels shall have End-cap/ Aluminium U-profile/ Glazing bar for ends as per requirement. The weight of the system shall not be less than 2.30 kg per square meter. Panel shall be co-extruded with specialist-glare compound to make it anti-glare/soft light to prevent glare and sun streaks. Panels shall be fixed over structural steel/ MS purlins conforming to the detail technical specifications and as per approved architectural drawings. The rate shall include the cost of above specified materials, fixing of the sheet, scaffolding and labour charges for working at all levels, leads and heights as directed by engineer in charge. Surface area of roof sheet shall be measured for payment. The supporting MS structure for panel shall be paid separately in relevant tender item. |
| 142 | Sec.15.0 General Development and Road worksProviding and laying rubble soling in plinth and sub-base of road, compacted thickness specified as following, using specified size of hard stones for average 150mm thick soling, filling, covering and leveling the surface with a layer of earth after filling the voids (upto 25%) with sand, smaller sized black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/metals or stone chips, including watering, ramming well and compacting or consolidating each layer by static roller/ vibratory roller of required capacity as directed by Engineer-in charge. |
| 143 | Vacuum dewatering Extra for carrying out vacuum dewatering & Power floater treatment in roads, pavements, floors well compacted, mechanically vibrated with screed vibrator, finished to required levels, floated with neat cement and power trowelled to get desired smooth finish / broom finish, over a leveling course, including MS channel or box shuttering, curing for 10 days with gunny bags etc complete. The size of panel should be approximately 3.75 x 5.5 m or as directed by Engineer. The Contraction joints to be formed at every 5m distance by grooving with mechanical saw within 48 hrs. Groove/sawed joints/ longitudinal joints shall be made of 6mm width and 25 mm depth min (1/3 rd depth of the pavement) as shown in the drawing. The rate shall be inclusive of labour, making the grooves and machinery cost. |
| 144 | Providing material and labour for fixing Ductile iron manhole frame and cover/ grating/ chamber cover of approved make and type. Man hole cover shall be any type (hinged type, double sealed or recess type), any shape (square/ rectangle/ square frame with round cover) any grade (light duty/ medium duty/ heavy duty) of required loading capacity having double sealed system as per manufacturing standard BS EN-124, with proper lifting arrangement, black bituminous coating, including fixing in CC and finishing etc complete as directed by engineer in charge. Cover shall be as per drawing and as per approved sample. Recess manhole cover depth shall be according to pavement/ finish as per drawing. |
| 145 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 146 | FRP UG Tank coverProviding and Fixing mediumduty double seal FRP UG Tank cover with frame of 5MT capacity, in matching shade of surrounding pavement and design according to EN - 124:1994 of HP or equivalent of clear opening size of 600mm dia having frame thickness average 50mm and cover thickness 25mm, of weight average 35 Kg with client's logo etc. complete as approved by architect and as directed by engineer in charge. Frame shall be embaded in concrete of M25 grade and top level of frame shall be flush with road level. Rate shall be inclusive of cover frame and concrete work. |
| 147 | Supplying mterial and labour for laying of following size DWC HDPE pipe of 63mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge. |
| 148 | Supplying mterial and labour for laying of following size DWC HDPE pipe of 90mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge. |
| 149 | Supplying mterial and labour for laying of following size DWC HDPE pipe of 120mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge. |
| 150 | Supplying mterial and labour for laying of following size DWC HDPE pipe of 160mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge. |
| 151 | Supplying mterial and labour for laying of following size DWC HDPE pipe of 200mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge. |
| 152 | 02-PLUMBING WORKSSection 1: Water SupplyProviding and laying in position ISI Marked (Embossed) 65mm diameter of Heavy duty “C” Class G.I . pipes as per IS: 1239, including fittings, threading the joints, fixing the joints with Teflon tapes, testing of the laid pipes as per standards, and laying underground including one coat of anticorrosive primer and wrapping material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process,overlap shall be maintained at 15mm as per specifications complete, and as approved and directed by Engineer-in-charge. (Excavation and backfilling excluded and extra as per relevant items) |
| 153 | Providing and laying in position ISI Marked (Embossed) 50mm diameter of Heavy duty “C” Class G.I . pipes as per IS: 1239, including fittings, threading the joints, fixing the joints with Teflon tapes, testing of the laid pipes as per standards, and laying underground including one coat of anticorrosive primer and wrapping material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process,overlap shall be maintained at 15mm as per specifications complete, and as approved and directed by Engineer-in-charge. (Excavation and backfilling excluded and extra as per relevant items) |
| 154 | Lowering, laying and jointing G.I. pipes with G.I. specials of 65mm diameter in proper position, grade and alignment as directed by Engineer-in-charge including conveyance from stores to site of work, labour, hydraulic testing, etc. complete. |
| 155 | Lowering, laying and jointing G.I. pipes with G.I. specials of 50mm diameter in proper position, grade and alignment as directed by Engineer-in-charge including conveyance from stores to site of work, labour, hydraulic testing, etc. complete. |
| 156 | Supplying, installation, testing and commissioning in position of ISI marked CI D/F Buttterfly Valves as per IS: 13095 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking at position with necessary material for installation. Butterfly Valves as per IS: 13095 PN 16 65 mm. |
| 157 | Supplying, installation, testing and commissioning in position of ISI marked CI D/F Buttterfly Valves as per IS: 13095 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking at position with necessary material for installation. Butterfly Valves as per IS: 13095 PN 16 50mm. |
| 158 | Supplying, installation, testing and commissioning in position of ISI marked Forged Brass Air Release Valves of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. Air Valves single type: 25mm diameter |
| 159 | Supplying, installation, testing and commissioning in position of Gun metal gate valve as per IS: 778, with C.I. wheel of approved quality having Pressure Class Rating of Class 1, Gun Metal (Forged Brass) body as per IS: 318 LTB2, Screwed bonnet, inside screw, rising stem, intergal seat of rubber (EPDM), solid wedge, Trim of Copper Alloy, Asbestos gland packing, secrewed female parallel thread as per IS: 554, body having 1.5 MPa hydraulic pressure rating and Seat having 1.0 MPa hydraulic pressure rating. (screwed end). 65mm dia nominal bore. |
| 160 | Supplying, installation, testing and commissioning in position of Gun metal gate valve with C.I. wheel of approved quality having Pressure Class Rating of Class 1, Gun Metal (Forged Brass) body as per IS: 318 LTB2, Screwed bonnet, inside screw, rising stem, intergal seat of rubber (EPDM), solid wedge, Trim of Copper Alloy, Asbestos gland packing, secrewed female parallel thread as per IS: 554, body having 1.5 MPa hydraulic pressure rating and Seat having 1.0 MPa hydraulic pressure rating. (screwed end). 50mm dia nominal bore. |
| 161 | Providing erecting and fixing Triple layered PE material ISI water tank of required capacity each with all necessary fittings and connection etc. complete on terrace. (Each tank of 500 liters capacity) |
| 162 | Providing and fixing in location MS Puddle Flange of the following diameters, having 'F' Table flanges at the inlet and outlet, and 'E' Table Puddle in the center with double welded joints, made of 150mm NB Heavy Duty (C Class) GI Pipe, tying the puddle with the Re-inforcement steel in the RCC walls at construction stage and in coordination with the structure engineers' designs, at the location as mentioned in the plumbing layouts. Size: 150mm diameter |
| 163 | Providing and fixing in location GI Threaded Flange of the following diameters, having 'F' Table threaded flanges at the inlet and outlet, and 'E' Table threaded puddle in the center with threading of pipes as required, made of 100mm NB Heavy Duty (C Class) GI Pipe, tying the puddle with the Re-inforcement steel in the RCC walls at construction stage and in coordination with the structure engineers' designs, at the location as mentioned in the plumbing layouts. Size: 100mm diameter |
| 164 | Providing and fixing in location GI Threaded Flange of the following diameters, having 'F' Table threaded flanges at the inlet and outlet, and 'E' Table threaded puddle in the center with threading of pipes as required, made of 80mm NB Heavy Duty (C Class) GI Pipe, tying the puddle with the Re-inforcement steel in the RCC walls at construction stage and in coordination with the structure engineers' designs, at the location as mentioned in the plumbing layouts. Size: 80mm diameter |
| 165 | Providing and fixing in location GI Puddle Flange of the following diameters, having 'F' Table flanges at the inlet and outlet, and 'E' Table Puddle in the center with double welded joints, made of 65mm NB Heavy Duty (C Class) GI Pipe, tying the puddle with the Re-inforcement steel in the RCC walls at construction stage and in coordination with the structure engineers' designs, at the location as mentioned in the plumbing layouts. Size: 65mm diameter |
| 166 | Providing and fixing full thread G.I. Tank Nipple (medium duty) as per IS: 1239, including drilling holes in the tanks at required levels, inserting the coupling in place, sealing the hole with silicon sealant, attaching the hex nuts on either side of the coupling as directed and approved by the Engineer-in-charge. (C) 32mm diameter |
| 167 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal Work - Exposed on wall - 20 mm nominal dia Pipes |
| 168 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal Work - Exposed on wall - 25 mm nominal dia Pipes |
| 169 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal Work - Exposed on wall - 32 mm nominal dia Pipes |
| 170 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal Work - Exposed on wall - 40 mm nominal dia Pipes |
| 171 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal Work - Exposed on wall - 50 mm nominal dia Pipes |
| 172 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete.[A] 15 mm. |
| 173 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm. |
| 174 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [C] 25 mm. |
| 175 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [D] 32mm. |
| 176 | Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Supreme / Ashirvad. a) 20 mm nominal bore |
| 177 | Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Supreme / Ashirvad. b) 25 mm nominal bore |
| 178 | Providing and fixing chlorinated polyvinyl chloride (CPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Supreme / Ashirvad. c) 32 mm nominal bore |
| 179 | Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) / XLPE insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. a) For 15mm diameter pipes |
| 180 | Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) / XLPE insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. a) For 20mm diameter |
| 181 | Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. b) For 25mm dia pipes - 19mm x 28mm Nitrile Rubber Plain Tubing |
| 182 | Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. c) For 32mm dia pipes - 25mm x 35mm Nitrile Rubber Plain Tubing |
| 183 | Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. d) For 40mm dia pipes - 25mm x 42mm Nitrile Rubber Plain Tubing |
| 184 | Providing & fixing of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation of the following diameter and thickness over hot water pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external hot water supply) all complete as per directions of the Engineer-In-Charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. e) For 50mm dia pipes - 25mm x 54mm Nitrile Rubber Plain Tubing |
| 185 | Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. complete. |
| 186 | Providing & fixing C.I. Manhole cover 0.6 x 0.45 M size having weight not less than 35 kg. |
| 187 | Section 2: SanitaryProviding & fixing Divyang toilet set with European Closet (P Trap) & wall mount wash basin & all divyang requirements with dual flush tank, seat & cover (heavy duty) with C.P. brass hinges,including WC connector of 110mm inlet x 110mm outlet, connecting the same with soil pipe using appropriate solvent cement, C.I. Brackets for wall mounting the basin, 32mm CP waste Coupling, 32mm size CP bottle trap, CP brass Spatula Faucet, etc. all Internal fittings complete with S.S grab rails etc. rubber buffers, C.P nuts, bolts etc making holes in walls & floors, & finishing for ready to use.The rate includes all necessary connection charges as per product detail to the satisfaction and as directed by the Engineer-in-charge. Make: Hindware / Cera. |
| 188 | Providing and fixing white vitreous china extended wall mounting water closet of size 530 x 330 x 390mm of approved shape including seat and cover, nuts, bolts, and gaslets etc complete. Make: Hindware - Flora / Jaquar - Florentine / Cera - Campbell Clear Rim. |
| 189 | Providing and fixing UPVC SWR WC Connector 130 x 110 mm dia. Socket type of approved make, fixed to outlet gaskets with UPVC Lubricant or Solvent Cement, all complete as per directions of the Engineer-in-charge. Make: Astral; Model No. F172005909 or Equivalent. |
| 190 | Providing and fixing Flat Back Large Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White vitreous China flat back large urinal size (355 to 420)mm x (240 to 395)mm x (535 to 635)mm. Make: Hindware - Eureka / Jaquar - URS / Cera - Carmina. |
| 191 | Providing and fixing countertop / table top wash basin having 15mm single hole in the middle for faucet fitting and 38mm hole in the bottom of the bowl for grid drain, cutting and making good the holes in the counter / table top wherever required: (i) White Vitreous China Counter Top / Table Top Wash Basin size (450 to 550) x (300 to 470) mm. |
| 192 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen Sink without drain board: Size: 510 x 430mm bowl depth 200 mm. |
| 193 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.69.2: Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60 gms. |
| 194 | Providing and fixing PTMT Bottle Trap for wash basin and sink, of approved quality and colour. 17.70.2: Bottle trap 38mm dia single piece moulded with height of 270mm, effective length of tail pipe 260mm from the center of the waste coupling, 77mm breadth with 25mm minimum water seal, weighing not less than 263 gms. |
| 195 | Providing and fixing 32mm CP Brass Full Thread Waste Coupling for wash basin, of approved quality and manufacturer's standards. Waste Coupling: 32mm dia of 83mm length, weighin not less than 60 gms. |
| 196 | Providing and fixing CP Brass Bottle Trap for wash basin, of size 250 x 190mm or nearabout, of approved quality and model. Bottle trap 32mm dia with height of 250mm, effective length of tail pipe 190mm from the center of the waste coupling, 77mm breadth with 25mm minimum water seal. |
| 197 | Providing and fixing ABS Chrome plated Brass Hand Shower (Health Faucet) of approved make and quality and as approved by Engineer - In - Charge, including 8 mm dia, 1 Meter long Flexible tube & wall hook including cutting and making good the walls wherever required complete as per directions of the Engineer-in-charge. |
| 198 | Providing and Fixing 15 mm dia. Wall mounted type CP brass pressmatic bib cock with Auto Closing System with Built-in Control Cock With Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. |
| 199 | Providing and fixing of 15mm nominal bore CP Brass Angle valve confirming to IS: 8931, for wash basins, water coolers, geyser points, etc of approved quality and as approved by and directed by the Engineer-in-charge. |
| 200 | Providing and Fixing 15 mm dia. CP brass two way bib cock with wall flange and ceramic disc cartridge complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. |
| 201 | Providing and Fixing in position 32mm CP brass Pressmatic WC (Metropole) Flush Valve Auto-closing system with built in Control Cock and Wall flange of approved or equivalent make, including 32mm UPVC pipe connection with WC, and including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. |
| 202 | Providing and Fixing in position CP brass Pressmatic Urinal Flush Valve Auto-closing system with built in Control Cock and Wall flange of approved or equivalent make, including 15mm S.S. pipe connection with Urinal and Urinal Spreader, and including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. |
| 203 | Providing and Fixing 15 mm dia. CP brass bib cock with Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. |
| 204 | Providing and Fixing 15 mm dia. Wall mounted type CP brass Sink cock with Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. |
| 205 | Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size. |
| 206 | Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet.(A) 100mm dia. Each |
| 207 | Providing and fixing C.P. brass Shower arm for over head shower of approved make and quality, and as approved by the Engineer-in-charge, and conforming to Manufacturers Standards. a) Size: Casted 190mm long light body round shape for wall mountedshower rose with flange, of approved make and as per the direction of the Engineer-in-charge. |
| 208 | Providing and fixing C.P. brass Single Lever Exposed Shower Mixer for exposed shower arm & Hand Shower , connecting legs & wall flanges, complete as per approved make and as directed by the Engineer-in-charge. |
| 209 | Providing and fixing Hand held Shower with 100mm round rose head single flow, with 1.5 meter flexible SS hose. |
| 210 | Providing and fixing PTMT grating of approved quality and colour: Rectangular type with openable circular lid: 150 mm nominal size square 100 mm diameter of the inner hinged round grating. |
| 211 | Providing and fixing SS Toilet Paper Roll Holder with Flap including SS screws & Rawl Plugs, complete as per approved make and as directed by the Engineer-in-charge. |
| 212 | Providing and fixing SS Liquid Soap Dispenser with metallic bottle having 250ml liquid holding capacity of approved make and quality and as directed by the Engineer-in-charge. |
| 213 | Providing and fixing SS Floor Cleanout (FCO) plug of approved brand and with SS Square Frame/ Round Frame with Flat Round Cover with Rubber Seal & SS Screw jointing as per manufacturer recommendation or per approval of the Engineer-in-charge.ii) 128mm x 128mm Square Top for 100 mm dia pipe. |
| 214 | Providing and fixing U.P.V.C (Type B) conforming to IS 13592, & fittings conforming to IS 14735 of approved make Multi Floor Trap Height Riser with 40mm x 50mm x 75mm inlet x 110mm dia outlet, as per specifications & at all levels & at all heights, as approved and directed by Enigeer-in-charge. |
| 215 | Providing, laying and jointing in true line and level 160 mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 216 | Providing, laying and jointing in true line and level 110 mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 217 | Providing, laying and jointing in true line and level 75mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 218 | Providing, laying and jointing in true line and level 50mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Pipe length per piece: 1.8 Mtrs |
| 219 | Providing, laying and jointing in true line and level 40mm diametre U.P.V.C (Type B) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to IS 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 220 | Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), P - Trap as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe |
| 221 | Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 75 mm Dia pipe |
| 222 | Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe |
| 223 | Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type A) conforming to IS 13592 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 224 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised-PVC rain water pipes conforming to IS : 13592 (Type A), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe Bend - 110mm dia pipe |
| 225 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes at an average distance of 1.2 meters centre to centre, by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 226 | Providing and fixing unplasticised -PVC corner gully trap of size 200mm long x 200mm wide , having 80x80x115 mm vertical connection for 75mm diameter pipe, of approved design as per IS: 14735, to unplasticised - PVC SWR (Type A) pipes at all floors and all levels as indicated in the drawings, within the floor bedding, including cutting floors and walls as required, and making good the floors and walls etc. complete as per the direction of the Engineer-in-charge. |
| 227 | Providing and fixing G.I. Rainwater spout of 50mm diameter and 30 cm length. |
| 228 | Sec.5.0 MECHANICALSHydro-pneumatic System - for Soft Water:Supply, Installation, Testing And Commissioning of Compact Self Contained Skid Mounted Hydropneumatic System as follows: Design, engineer, procure, supply, test and commission a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient pump, IE3 motors, skid mounted, complete ready-to-connect packaged variable speed water pressure booster station. The packaged variable speed water pressure booster station shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency IE 3 motors, an air-cooled external variable frequency drive, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an IP 67 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors/switches; Stainless Steel (SS 304) suction and delivery manifolds; isolation ball valves on suction and discharge of each pump; non return valve on discharge side of each pump; hot dip galvanised common base frame; and diaphragm pressure vessel. Complete (Skid mounted / wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor). All installations such as electrical wiring from Electrical Panel to Pump panel, civil foundations, etc is included in this scope. Set of accessories such as NRVs, isolating valves, Stainless Steel (SS 304) suction and delivery header, pressure gauge, MS Epoxy coated base frame, pressure switches, pressure transducers, inter connecting power and control cabling etc. complete.For Soft Water: Soft Water Supply - Set consisting of 3 pumps (2 working + 1 standby); Flow Rate (System): 334 LPM (20.04 Cu. Mtr / Hr); Pressure Vessel = 1 x 200 Ltrs; Head (each pump): 75 Mtrs. |
| 229 | Submersible Pumps for Recycled Water:Supply, Installation, Testing and Commissioning of open well vertical multi stage (submersible) pump set with Stainless-steel body, C.I. Bearings, Stainless-steel motor shaft, Stainless-steel impeller, scope also includes the Star-Delta / Soft Start starter panels, cables/wires to the pumps, the pump controller shall be mounted in a control cabinet with an IP 67 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors / switches, complete for one / three phase submersible motor having the following discharge capacity and head: Recycled Water Transfer from STP to Roof Tank: No. of Pumps: 2 (1W + 1S); System Flow: 300 LPM (18 cum / hr); Head: 75 Mtrs. |
| 230 | Hydro-pneumatic System - for Soft Water - at all Terraces:Supply, Installation, Testing And Commissioning of Compact Self Contained Skid Mounted Hydropneumatic System as follows: Design, engineer, procure, supply, test and commission a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient pump, IE3 motors, skid mounted, complete ready-to-connect packaged fixed speed water pressure booster station. The packaged fixed speed water pressure booster station shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency IE 3 motors, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an IP 67 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors/switches; Stainless Steel (SS 304) suction and delivery manifolds; isolation ball valves on suction and discharge of each pump; non return valve on discharge side of each pump; hot dip galvanised common base frame; and diaphragm pressure vessel. Complete (Skid mounted / wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor). All installations such as electrical wiring from Electrical Panel to Pump panel, civil foundations, etc is included in this scope. Set of accessories such as NRVs, isolating valves, Stainless Steel SS 304 suction and delivery header, pressure gauge, MS Epoxy coated base frame, pressure switches, pressure transducers, inter connecting power and control cabling etc. complete.For Soft Water: Soft Water Supply - Set consisting of 2 pumps (1 working + 1 standby); Flow Rate (System): 150 LPM (9 Cu. Mtr / Hr); Pressure Vessel = 1 x 50 Ltrs; Head (each pump): 25 Mtrs. |
| 231 | Water Treatment Plant: Supply, Installation, Testing and Commissioning of water treatment plant having Activated Carbon filters, Multi-grade / Pressurized Sand filters, Softeners including resin & salts, Resin Treament, Anti-scalant treatment, or any of these in a combination to provide scaling free water to all buildings within the campus, including centrifugal multistage water pump (1 working + 1 standby), connected plumbing work, control panel for auto cutoff, auto on, auto regeneration, auto rinse and auto filter mode with IP55 protection with all necessary equipment, piping and connected activities as per specification and operating conditions as mentioned by manufacturer or as directed by engineer in charge. System Capacity: 88,000 litres per day. |
| 232 | Hot Water Plant: Supplying, installing, testing and commissioning of Electrically Operated Air-to-Water Heat Pump Hot Water System capable of producing Hot water up to 60°C, at ambient temperature of 12°C to 55°C. Heat pump should have an IPX4 compatible control panel, designed and built in manufacturer's factory and compliant to norms for the same and compatible to support 9 units in parallel. Inbuilt 4 Ways valve for auto defrost function. The heat pump shall have an operational noise level of less than or equal to 65 dB(A). Model should be with tube in tube type heat exchanger Comprising of helical rotary twin compressors with direct drive motor (the compressor speed shall not exceed 3000 RPM) with shell and tube type plain tube chiller as well as shell & insulated tube type integrally finned condenser, at working efficiency of minimum 80%, having heating capacity up to 60 degree centigrade, capable to withstand up to 500 ppm water hardness. The heat pump package shall include vibration mountings, copper refrigerant piping as per the latest applicable B.I.S. codes and standards, full refrigerant charge using CFC free gas, system control wiring and accessories, installed on a fabricated mild steel base frame assembled to form a compact assembly, complete with micro-processor based control panel comprising of adaptive controls, indication lights, Star-Delta starters, over-load and under-load protection, TPN isolator for termination of incoming power cable, necessary control wiring, disconnect switch, grooved (Victaulic couplings at inlet and outlet of both heat exchangers, DP switches for both heat exchangers, vibration isolation arrangements electrical panel with starter for Heat Pumps, testing of all systems post installation at Minimum Wet Bulb Temperature of 17.7 degree Celsius in January to deliver hot water at 55 degree Celsius. The scope also includes commissioning of the entire system, commissioning certificate in the name of the Engineer-in-charge, etc. complete as per manufacturing standards and to the complete satisfaction of the Engineer-in-charge. The scope includes pre-insulated S.S. storage tanks or M.S. storage tanks with ceramic lining, of capacity as mentioned below, including making inlet, outlet heavy gauge C.P. connection, temperature guages (at inlet and outlet of storage tank). The Storage Tanks duly painted with two coats of Red-Oxide and having PUF / Rockwool insulation, outer cladding of 22 guage Aluminum Sheet, control valves at inlet and outlet of Water tank, M.S. supports for the tanks with M.S. base plate, bolts and nuts for fastening the stands and support to Cement concrete blocks, testing the tanks and the entire hot water system at a constant water pressure of 5.0 Bar (Hyd.) each, testing of the entire system for a constant flow of hot water at 60 degree Celcius during peak winter when the Wet Bulb Temperature is 17.7 degree Celcius. FOR HOSTEL BLOCK: Total System Capacity: 6000 LPD; Pre-insulated Hot Water Storage Tank with multiple inlets and outlets: 6000 Ltrs.; Heat Pump HWS: 2 sets, electrical starter panels, level sensors, temperature sensors, thermostat, temperature gauges, pressure gauge, interconnecting G.I. 'C' class pipes with nitrile rubber cladding and aluminium cladding, complete. |
| 233 | Hot Water Plant: Supplying, installing, testing and commissioning of Electrically Operated Air-to-Water Heat Pump Hot Water System capable of producing Hot water up to 60°C, at ambient temperature of 12°C to 55°C. Heat pump should have an IPX4 compatible control panel, designed and built in manufacturer's factory and compliant to norms for the same and compatible to support 8 units in parallel. Inbuilt 4 Ways valve for auto defrost function. The heat pump shall have an operational noise level of less than or equal to 65 dB(A). Model should be with tube in tube type heat exchanger Comprising of helical rotary twin compressors with direct drive motor (the compressor speed shall not exceed 3000 RPM) with shell and tube type plain tube chiller as well as shell & insulated tube type integrally finned condenser, at working efficiency of minimum 80%, having heating capacity up to 60 degree centigrade, capable to withstand up to 500 ppm water hardness. The heat pump package shall include vibration mountings, copper refrigerant piping as per the latest applicable B.I.S. codes and standards, full refrigerant charge using CFC free gas, system control wiring and accessories, installed on a fabricated mild steel base frame assembled to form a compact assembly, complete with micro-processor based control panel comprising of adaptive controls, indication lights, Star-Delta starters, over-load and under-load protection, TPN isolator for termination of incoming power cable, necessary control wiring, disconnect switch, grooved (Victaulic couplings at inlet and outlet of both heat exchangers, DP switches for both heat exchangers, vibration isolation arrangements electrical panel with starter for Heat Pumps, testing of all systems post installation at Minimum Wet Bulb Temperature of 17.7 degree Celsius in January to deliver hot water at 60 degree Celsius. The scope also includes commissioning of the entire system, commissioning certificate in the name of the Engineer-in-charge, etc. complete as per manufacturing standards and to the complete satisfaction of the Engineer-in-charge. The scope includes pre-insulated S.S. storage tanks or M.S. storage tanks with ceramic lining, of capacity as mentioned below, including making inlet, outlet heavy gauge C.P. connection, temperature guages (at inlet and outlet of storage tank). The Storage Tanks duly painted with two coats of Red-Oxide and having PUF / Rockwool insulation, outer cladding of 22 guage Aluminum Sheet, control valves at inlet and outlet of Water tank, M.S. supports for the tanks with M.S. base plate, bolts and nuts for fastening the stands and support to Cement concrete blocks, testing the tanks and the entire hot water system at a constant water pressure of 5.0 Bar (Hyd.) each, testing of the entire system for a constant flow of hot water at 55 degree Celcius during peak winter when the Wet Bulb Temperature is 17.7 degree Celcius. FOR KITCHEN BLOCK: Total System Capacity: 9000 LPD; Pre-insulated Hot Water Storage Tank: 9000 Ltrs.; Heat Pump HWS: 1 set, electrical starter panels, level sensors, temperature sensors, thermostat, temperature gauges, pressure gauge, interconnecting G.I. 'C' class pipes with nitrile rubber cladding and aluminium cladding, complete. |
| 234 | Supplying and erecting horizontal / vertical mounting type storage water heater with copper container housed in M.S./S.S./ABS body insulated with glass wool/puff complete with heating elements,adjustable thermostats 300C to 850C, indicating lamp, safety valve, fusible plug, etc.complete erected with coach bolts, nuts. washers & cementation. (For Kitchen only) - (E) 50 Ltr. with 2 / 3 KW. heating element - Premium Category (Racold,A.o.Smith,Venus) |
| 235 | Supplying and erecting chromium plated heavy duty brass valve for inlet pipe of water heater 15 mm dia.) |
| 236 | Supplying and erecting 15mm brass non-return valve for inlet pipe of storage water heater. |
| 237 | Supplying and erecting dead pressure releasing valve for storage type water heater with necessary materials. |
| 238 | Providing & erecting fibre reinforced PVC flexible pipe with brass locking nuts & washers & clips at both ends complete erected without leakage |
| 239 | R.O. Plant: Supply, Installation, Testing and Commissioning of Reverse Osmosis water treatment plant having basket filter, Micro-cartridge filters, R.O. membranes, for providing purified drinking water to all buildings within the campus, including centrifugal multistage water pump (1 working + 1 standby) as per design requirement, connected plumbing work, control panel for auto cutoff, auto on, auto regeneration, auto rinse and auto filter mode with IP67 protection with all necessary equipment, piping and connected activities as per specification and operating conditions as mentioned by manufacturer or as directed by engineer in charge. System Capacity: RO - 400 LPH (Permeate) ; Feed – 0.6 m3/hr @ 70 - 80% recovery with drinking water parameters as mentioned in relevant codes and standards. Operating pressure: 10 – 12 Bar |
| 240 | Drinking Fountains:Supply, installation, testing and commissioning of wall hanging Single level drinking water cooler & fountain with One Bottle Filling Station, having rated capacity of 8.0 GPH suitable to deliver cold water , shall include 100 micron strainer, 3 stage filtration system, single flexible bubbler guard, antimicrobial copper push pads, and and operation between 20-120 PSI, shall able to dispense ambient water & provide cold water, Continuous chilling system suitable to R-134(a) refrigerant, adjustable thermostat control suitable for 220 - 230 V / 50-60 Hz, AC supply. Stainless Steel Brushed Finish Basin shall be designed to eliminate splashing and standing water. Water saver SS bubbler reduce waste water by 50%, with UV system of 50 LPH with G.I. Skid for mounting the UV lamp, and complete instrumentation. Cabinet finish shall be brushed stainless steel. The scope includes all necessary hardware like stop valve, trap, pipe connector to waste line and supply line. |
| 241 | LEVEL SENSORS:Supplying & erecting approved make Automatic liquid level controller 6A.as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank. |
| 242 | Sewage Treatment Plants:Supply, installation, testing & commissioning of Sewage Treatment Plant MBBR Type (Package Treatment Plant) of 85 kLD with collection tank, primary, secondary & tertiary treatment also with all electromechanical equipments, interconnected piping, valves, pumps, instruments, gauges, electrification like panel, starter, cabling, earthing, pH correction dosing system, aeration blowers, feed pumps, clarifiers, hypo dosing, coagulant dosing, flocculant dosing, sludge recirculation pumps, & tertiary treatment including multi-grade filter, activated carbon filter, 38 kLD Ultra-filtration, also with all electromechanical equipments, interconnected piping, valves, pumps, instruments, gauges, electrification like panel, starter, cabling, earthing, etc. complete. The sizing of tank/equipment shall take care of average as well as peak flow. The outlet parameters shall be as per specifications.(Including civil cost of Bar Screen Chamber) (Cost of civil works for tanks not included). The entire system shall be installed, all relevant approvals from local and other authorities to be procured, submitting of the reports, certificates, etc as per norms and requirements, training of staff, handing over all relevant documents, etc complete as directed and approved by the Engineer-in-charge. |
| 243 | DRAINAGE SUMP PUMP:Providing and fixing compact monoblock dry motor submersible pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity of up to at least 30mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend complete.The pump sets shall be supplied with required accessories & as per specification with the following : (a) Water level sensing – switch type or hydraulic floats or pressure switch – with data accessible on IBMS platforms.(a) Complete piping 80 mm dia common delivery up to 12 m in heavy Duty Class 'C' G.I. – 10 meters length.(c) 80 mm dia Flap type Forged Brass Non-return valve. – 2 Nos. (d) 80mm dia Forged Brass Gate Valve. – 1 No.(e) Necessary cables from pump set to control panel (10 meters) – 1 Set (f) Electrical control panel having all necessary accessories & safety devices of standard specifications and suitable for receiving supply cable to connections within, and outlet connections for starters, and earthing outlets, complete. All best standards, as per ECBC & IS Codes to be followed and provided. Starters to be operated on cascading operations, so as to maintain maximum life cycle of each pump. – 1 Set.(g) Panels to have Modbus / BACnet connectivity, with pump performance data, pump fault data, On / Off operations, etc to be incorporated.(h) Each set consist of 2 nos. of pumps - 1 working & 1 stand by.Discharge: 25 Cu. Mtr / Hr.Head: 15 Meter (minimum). |
| 244 | SEC03 -ELECTRICAL WORKSELW 01.00 HT RMU / HT PANELSupplying, Installtion,Testing & Commissioning of outdoor duty SF6 insulated RMU with 2 nos.400A HT Load breakswitch & 1 no tapoff 400A VCB with CT & PT & lockable metering compartment as per supply company guideline.The panel should have tinned copper busbars . This should be complete with metering and protection and complete in all as per specification. - (For Supply company Metering) |
| 245 | Supplying, Installtion,Testing & Commissioning of 1 no.400A HT VCB as incomer and 2 nos 400A HT VCB as outgoings .The panel should have tinned copper busbars and extensible type for future requirements. This should be complete with metering and protection and complete in all as per specification. - (For Client side) |
| 246 | ELW 02.00 TransformerSupplying, Installtion,Testing, Commissioning & unloading at site, shifting to the erection site assembling, leveling, grouting, installing, field testing and commissioning of 500KVA Dry type Transformer with on load tape chagner with OLTC and RTCC. Scope also includes connection between OLTC and RTCC. Complete in all respect as per specification. |
| 247 | ELW 03.00 Substation Equipment and substaion AuxiliarySITC of 11 KV, 3 core Al. 240 sqmm H.T. XLPE armoured unearth cable. |
| 248 | SITC of H.T. cable indoor type end connection for 11 KV XLPE, 240 sq mm x 3 core cable with all accessories including lugs |
| 249 | Suppplying & Erecting automatic emergency light with maintenance free battery for 2 X 18 watts CFL tube. With exide make battery |
| 250 | Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (b)4mm |
| 251 | Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (c)12mm |
| 252 | Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. |
| 253 | Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for HIGH VOLTAGE installation to be erected as per IS.-2551. |
| 254 | Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\\" diagonally size. |
| 255 | Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. |
| 256 | Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes) |
| 257 | Supplying and instaling FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.. |
| 258 | Supplying & Erecting 1.5 mtr. (5') x 0.9 mtr. (3.1') x 0.6 mtr. (2.1') Floor mounted stand (For keeping 4 Nos.of buckets) made of 30 x 30 x 4 mm. angle iron welded with 4 hooks and duly painted with one coat of red lead & two coats of Approved enameled silver paints. |
| 259 | Supply installation testing and commissionning of Wall hooks of 22 to 25 cms. projection for keeping fire buckets made out of 15 mm. dia M.S. rod grouted in wall to a depth of minimum 15 cms. |
| 260 | ELW 04.00 MV Switch Gear and power PanelSupplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respectMAIN LT POWER PANELAs per Single line diagram |
| 261 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect250KVAR APFCR PANELAs per Single line diagram |
| 262 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respectUTILITY PANELAs per Single line diagram |
| 263 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL BLOCK POWER PANEL-TOP SIDEAs per Single line diagram |
| 264 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL BLOCK UPS PANEL-TOP SIDEAs per Single line diagram |
| 265 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL TERRACE PLUMBING PANEL - OUTDOOR TYPE - TOP SIDEAs per Single line diagram |
| 266 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL ADMIN PANELAs per Single line diagram |
| 267 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL BLOCK POWER PANEL-BOTTOM SIDEAs per Single line diagram |
| 268 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL BLOCK UPS PANEL-BOTTOM SIDEAs per Single line diagram |
| 269 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.HOSTEL TERRACE PLUMBING PANEL - OUTDOOR TYPE - BOTTOM SIDEAs per Single line diagram |
| 270 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.CANTEEN POWER PANELAs per Single line diagram |
| 271 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.CANTEEN UPS PANELAs per Single line diagram |
| 272 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.CANTEEN HVAC PANEL - OUTDOOR TYPEAs per Single line diagram |
| 273 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.CANTEEN TERRACE PLUMBING PANEL - OUTDOOR TYPEAs per Single line diagram |
| 274 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.PLUMBING+STP PANELAs per Single line diagram |
| 275 | ELW 05.00 DG Set with AMF panelSupplying, installation, testing and commissioning of DG set of 2 # 500 KVA with approximate 602 BHP engine with enclouser & suitable alternator complete with all necessary fuel piping,Aluminium cladding, exhaust piping, control panel, Auto synchronizing, auto load sharing AMF Panel, silencer & its piping, Acoustic silencer, Alternator cable termination box suitable for Aluminium cables,initial battery charging,base frame, battery and charger complete in all respect. Scope also includes preparing necessary drawing submitting to authorities, getting their approval / sanction and final certificate including NOC from pollution board(if required) to energize the D G Set . (Rate Includes 2 Nos. of 500 kVA Dg sets, 2 Nos. Control & AMF Panels and 1 No. of Auto synchronizing Panel etc. -Please refer Specification for Auto Sycn. Panel) |
| 276 | ELW 06.00 Distribution BoardDISTRIBUTION BOARD Supplying, assembling, grouting, levelling, installation, Connecting testing and commissioning of D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement.Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) with 8 way PPI kit |
| 277 | Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way SPN D.B.) |
| 278 | Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 4 SPMCB as outgoing per phase (i.e. 8 way SPN D.B.) |
| 279 | Supplying, erecting, testing and commissioning of SPN D.B. suitable for outdoor mounting IP 65 with space for DPMCB as incoming and 2 SPMCB as outgoing (i.e. 4 way SPN D.B.) equivalent to Hensel make cat No.. KV 7104 |
| 280 | MCB 's and its AccessoriesSupplying, Assembling, levelling, connecting testing and commissioning of following MCB / ELMCB / MCCB etc in boards as specified in above items.Miniature circuit breaker single pole 1A to 32A. suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark. |
| 281 | 16A /20A / 25A / 32 A DP RCCB (30mA) |
| 282 | 16A /20A / 25A / 32A DP RCBO(RCCB+MCB) (30mA) |
| 283 | 40 A FP RCBO(RCCB+MCB) (300mA) |
| 284 | 6-32 A FP MCB |
| 285 | 40A FP MCB |
| 286 | 63A FP MCB |
| 287 | SITC of Blank Plates |
| 288 | Caution Board :SITC of Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B. |
| 289 | ELW 07.00 MV CablingSupply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.240 Sq.mm x 3.5C Al. Cable |
| 290 | Supply, testing and Layingand commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.150 Sq.mm x 3.5C Al. Cable |
| 291 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.95 Sq.mm x 3.5C Al. Cable |
| 292 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.70 Sq.mm x 3.5C Al. Cable |
| 293 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.35 Sq.mm x 3.5C Al. Cable |
| 294 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.10 Sq.mm x 4C CU. Cable |
| 295 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.6 Sq.mm x 4c CU. Cable |
| 296 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.4 Sq.mm x 4c CU. Cable |
| 297 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.2.5 Sq.mm x 4c CU. Cable |
| 298 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.10 Sq.mm x 3c CU. Cable |
| 299 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.6 Sq.mm x 3c CU. Cable |
| 300 | Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.4 Sq.mm x 3c CU. Cable |
| 301 | ELW 08.00 Cable TerminationSITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:240 Sq.mm x 3.5C Al. Cable |
| 302 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:150 Sq.mm x 3.5C Al. Cable |
| 303 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:95 Sq.mm x 3.5C Al. Cable |
| 304 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:70 Sq.mm x 3.5C Al. Cable |
| 305 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:35 Sq.mm x 3.5C Al. Cable |
| 306 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:10 Sq.mm x 4C CU. Cable |
| 307 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:6 Sq.mm x 4C CU. Cable |
| 308 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:4 Sq.mm x 4C CU. Cable |
| 309 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:2.5 Sq.mm x 4C CU. Cable |
| 310 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:10 Sq.mm x 3c CU. Cable |
| 311 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:6 Sq.mm x 3c CU. Cable |
| 312 | SITC of Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:4 Sq.mm x 3c CU. Cable |
| 313 | ELW 09.00 Cable TraySupply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :150 x 100 made out of 2 mm thick ladder type |
| 314 | Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :300 x 100 made out of 2 mm thick ladder type |
| 315 | Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :450 x 100 made out of 2 mm thick ladder type |
| 316 | Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :600 x 100 made out of 2 mm thick ladder type |
| 317 | Supply, Installation, testing and commissioning of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :750 x 100 made out of 2 mm thick ladder type |
| 318 | Supply, Installation, testing and commissioning of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :150 x 100 made out of 2 mm thick perforated type |
| 319 | Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc. |
| 320 | ELW 10.00 Internal WiringWITH MODULAR TYPE SWITCHESWiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board.The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as underFor Light Points /fan point/ wall fan / 6A 3 Pin Plug- DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth- SB to on board Point - 1.5 sqmm for Phase & Neutral & EarthFor 6A Plug point.- 1.5 sqmm for Phase, Neutral & EarthFor 6/10/16A general purpose plug point- 2.5 sqmm for Phase, Neutral & 1.5 sqmm EarthFor 16A plug point for A/C and Geyser- 4 Sqmm for Phase, Neutral & 2.5 sqmm EarthFor 20/32A plug point- 6 sqmm for Phases, Neutral & 4 sqmm EarthNo zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted.One light point controlled by one single way 6 A switch. |
| 321 | Loop light point to be controlled from same switch.(Looping from first point) |
| 322 | One light point controlled by two, two way 6 A switch |
| 323 | One ceiling fan outlet point controlled by one 6 A switch and hum free electronic type step regulator and cast iron fan box. |
| 324 | One 6 A x 5 pin 250 Volt universal socket outlet point controlled by one 6 A switch located on switch board. |
| 325 | 6 A x 5 pin 250 Volt universal switched socket outlet point at convenient location. |
| 326 | 6/16 A x 250 V switch socket point on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB. |
| 327 | Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location. |
| 328 | SITC computer power supply point with 2 nos of 6 amp 5 pin socket with 1 no. of 6/16 Amp. socket with 1 no 16 A Switch with indicator & wiring of computer point will be done through 2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1 nos. of 1.5 sq.mm.as earth wire. .( This cost includes the wiring from DB to Computer point.) |
| 329 | 20 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 2 module legrand make Cat no.56661 or equivalent but without cost of wiring and piping. |
| 330 | 32 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56669 or equivalent but without cost of wiring and piping. |
| 331 | 32 A x 415 V plug & socket with interlocked switched socket, FP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56674 or equivalent but without cost of wiring and piping. |
| 332 | METAL CLAD SWITCJH SOCKETSITC of Metal Clad Switch Socket with 10A SP MCB (2P+E) |
| 333 | SITC of Metal Clad Switch Socket with 20A DP MCB (2P+E) |
| 334 | SITC of Metal Clad Switch Socket with 20A FP ELMCB (2P+E) |
| 335 | SITC of Metal Clad Switch Socket with 32A FP ELMCB (P+E) |
| 336 | MAINSSITC of mains with 4 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories. |
| 337 | SITC of mains with 2 nos. of 4 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. |
| 338 | SITC of mains with 2 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. |
| 339 | SITC of mains with 2 nos. of 2.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. |
| 340 | ELW 11.00Light Fixtures and FansSupplying and erecting, testing and commissioning of 18W LED recessed Mounted Down Lighter -Make Wipro (18W MOLIS LD06-221-XXX-57-XX) or equivalent as per apporved make list. |
| 341 | Supplying and erecting, testing and commissioning of 12W LED recessed Mounted Down Lighter -Make Wipro (12W MOLIS LD06-151-XXX-57-XX) or equivalent as per apporved make list. |
| 342 | Supplying and erecting, testing and commissioning of 33W LED Recessed Mounted Circular Down Lighter -Make Wipro (MOLIS LD06-301-XXX-57-XX) or equivalent as per apporved make list. |
| 343 | Supplying and erecting, testing and commissioning of 1x10W 600mm LED Surface Mounted indoor Linear smart Bright Battern Lights Fittings -Make Phillips ( BN021) or equivalent as per apporved make list. |
| 344 | Supplying and erecting, testing and commissioning of 1x20W 1200mm LED Surface Mounted indoor Linear smart Bright Battern Lights Fittings -Make Phillips ( BN021C) or equivalent as per apporved make list. |
| 345 | Supplying and erecting, testing and commissioning of 18WLED Surface Mounted Down Lighter -Make Crompton (LCDSPLN-R-18-CDL) or equivalent as per apporved make list. |
| 346 | Supplying and erecting, testing and commissioning of 26W Circular LED Surface Mounted indoor Lights Fittings with High Efficency Translucence Diffuser -Make Wipro ( MOLIS LD06-301-XXX-57WSM) or equivalent as per apporved make list. |
| 347 | Supplying and erecting, testing and commissioning of 25W Cylindrical LED Surface Mounted indoor Lights Fittings with High Efficency Translucence Diffuser -Make K-LITE CYLIN ID-7346 or equivalent as per apporved make list. |
| 348 | Supplying and erecting, testing and commissioning of 38W 650mm dia LED Hanging Light Point Type Vela Round 1250 direct/indirect -Make XAL or equilavent (iO-71-260 38 W) ( 4000K) |
| 349 | Supplying and erecting, testing and commissioning of 20W LED Surface Mounted Industrial Corroson proof Fixture Ip 65 -Make Crompton (IPFC111LT8-16 1X 20W) or equivalent as per apporved make list. |
| 350 | Supplying and erecting, testing and commissioning of 40W LED Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton (IPFC112LT8-16 2X 20W) or equivalent as per apporved make list. |
| 351 | Supplying and erecting, testing and commissioning of 10W LED Wall Mounted Bulk head Light -Crompton (Type-STUD-LBHP-10-CDL) or equivalent as per apporved make list. |
| 352 | Supplying and erecting, testing and commissioning of 21W 4' Feet LED Surface / Recessed / Suspended Mounted indoor Channel Linear Lights Fittings with diffuser-Make Philips make Channel RC780B LED 26S-6500PSU W6L120ODSI or equivalent as per apporved make list. |
| 353 | Supplying and erecting, testing and commissioning of 46W 8' Feet LED Surface / Recessed / Suspended Mounted indoor Channel Linear Lights Fittings with diffuser-Make Philips make Channel RC780B LED 52S-6500PSU W6L240ODSI or equivalent as per apporved make list. |
| 354 | Supplying and erecting, testing and commissioning of 60W 8' Feet LED Surface / Recessed / Suspended Mounted indoor Channel Linear Lights Fittings with diffuser-Make SP760P LED 52S-6500PSU W6L240ODSI or equivalent as per apporved make list. |
| 355 | SITC of Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 900 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing |
| 356 | SITC of Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing |
| 357 | SITC of 19/20mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/O. 2 flat 3 core flexible wire with ear thing. |
| 358 | Supplying and erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM. (E)450 mm dai 1400 RPM (CAT-2) |
| 359 | SITC of suitable M.S. louver shutter of the Exhaust fan. |
| 360 | ELW 12.00 EarthingSupplying, installing, testing & commissioning of Maintenance Free Chemical Earthing System consisting of (A) Copper Bonded Earth Rod of 3 Mtr x 5/8\\" size using earth enhancing compound of 25 Kg & termination clamp. Complete in all respect with all reuqired accessories. |
| 361 | Earth wire/strips :Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with :a) Fixing accessories.b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link |
| 362 | SITC of No.8 gauge bare cu. earth wire Complete in all respect with all reuqired accessories. |
| 363 | ELW 13.00 Miscellaneous PVC PIPESSupplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia with GI pulling wire. |
| 364 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia with GI pulling wire. |
| 365 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia. |
| 366 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia. |
| 367 | DWC PIPESProviding & laying. DWC pipe for cable to be laid 90 cms. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original.(A) 50 mm dia |
| 368 | Providing & laying. DWC pipe for cable to be laid 90 cms. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original.(B) 90 mm dia |
| 369 | Providing & laying. DWC pipe for cable to be laid 90 cms. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original.(A) 120 mm dia |
| 370 | ELW 14.00Fire StopperSITC of Fire stop mortar system , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document (as per IFC Guidelines) prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer guidelines and UL system test certificates or approved EJ document. . |
| 371 | SITC of rodent and termite proof Fire Barriers on both sides of wall ( Composite Sheet) system for 2 hours fire rating when tested in accordance with ASTM E 814/UL 1479 standards. The small gaps left around the penetrants should be closed with Intumescent sealant , or with Fire rated Moldable Putty , which should be soft & moldable to any shape, to give complete L Rating. This system is to seal all fire rated vertical in wall made of concrete, masonry, metal, gypsum partition, after passing service lines like cables/cable bundles, cable trays etc. The system shall be UL listed & classified and product shall bear the UL & FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer's guidelines and UL system test certificates or approved EJ document. |
| 372 | SITC of Provide expanding firestop foam on both sides of wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal/ vertical openings in floors / wall or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundlesThe system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. The system shall be UL listed & classified and product shall bear the UL & FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document (as per IFC Guidelines) prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer.Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer's guidelines and UL system test certificates or approved EJ document. |
| 373 | SITC of intumescent based coating on cables/bunch cables & cable tray for at least 1 mtr in every 14 mtrs for horizontal runs and to entire length of vertical runs . The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. Firestop installation shall be done by manufacturer's Accredited Firestop Speciality Contractor (HAFSC) and in accordance with manufacturer's guidelines . |
| 374 | SITC of Pre-formed block CFS BL made from intumescent polyurethane material for temporary or permanent firestop sealing around cables, cable bundles and conduits. The system shall be UL listed & classified and product shall bear the UL & FM approval logo on the packing. If none of UL test certificate comply with actual application, an EJ document (as per IFC Guidelines) prepared by a qualified personnel and based on nearest third party tested & approved systems like UL test certificates & in accordance with IFC guidelines shall be producted by manufacturer. Firestop installation shall be done by Hilti Accredited Firestop Speciality Contractor (HAFSC) and in accordance with Hilti guidelines and UL system test certificates or approved EJ document. |
| 375 | ELW 15.00 Lighitning ProtectionAir termination SystemSupply, Installation, Testing & Commissioning of 8mm Aluminum Solid Round Conductor for building terrace as a horizontal air terminal as per required LPL and should be tested for electrical resistivity, Tensile strength, Yield strength, % elongation, salt spray & humidity test to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 with all accessories like of Stainless steel Parapet Conductor Holder, Flat roof Conductor Holder, Stainless Steel cross connector, Expansion Piece with connector at every 20mtr of horizontal airterminal to compensate the expansion, Straight connector etc. |
| 376 | Supply, Installation, Testing & Commissioning of 2 metre Vertical Airterminal of dia 16-10 mm with Complete Support of Concrete Base(370mm dia) and Air Terminal Conductor joining Clip selected as per angle of protection chart to meet the requirement of IS/IEC 62305 .Tested for Electrical ,Mechanical and Chemical as per IEC 62561. VAT 2 with mounting accessories on flat surface (includes - VAT 2 + interception tip + Base support stone + air terminal joining clip & stainless Steel Earthing stud with connector & D-Clamp for interconnecting ELPS and structral down conductors) CAPE Type :VATF 2 (Article No. 401 420) |
| 377 | Supply, Installation, Testing & Commissioning of 3 metre Vertical Airterminal of dia 16-10 mm with Complete Support of wall clamp selected as per angle of protection chart to meet the requirement of IS/IEC 62305 .Tested for Electrical ,Mechanical and Chemical as per IEC 62561. VAT 3 with mounting accessories on parapet wall surface (includes - VAT 3 + interception tip + 2 no of wall clamps+connecting point & stainless Steel Earthing stud with connector & D-Clamp for interconnecting ELPS and structral down conductors) CAPE Type :VATW 3 (Article No. 404 430) |
| 378 | Supply, Installation, Testing & Commissioning of 4 metre Vertical Airterminal of dia 16-10 mm with Complete Support of Concrete Base(370mm dia) and Air Terminal Conductor joining Clip selected as per angle of protection chart to meet the requirement of IS/IEC 62305 .Tested for Electrical ,Mechanical and Chemical as per IEC 62561. VAT 4 with mounting accessories on flat surface (includes - VAT 4 + interception tip + Base support stone + air terminal joining clip & stainless Steel Earthing stud with connector & D-Clamp for interconnecting ELPS and structral down conductors) CAPE Type: VATF4 (Article No. 401 440) |
| 379 | Down Conductor SystemSupply, Installation, Testing & Commissioning of 10 mm copper bonded Round steel solid Conductor for Down conductor meet the requirements of IS/ IEC 62305 and IEC 62561-2 with Bonding clamp/Rebar Hook for interconnecting 10mm-18mm round conductor and stainless steel straight connector at every 3.5M.CAPE Type No. SRC 10 – CU (Article No. 400 010) |
| 380 | Earthing SystemSupply, Installation, Testing & Commissioning of 10 mm copper bonded Round steel solid Conductor for ring earthing meet the requirements with installation of welding. of IS/ IEC 62305 and IEC 62561-2 CAPE Type No. SRC 10 – CU (Article No. 400 010) |
| 381 | ELW 16.00 UPSSupply , Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 6KVA UPS 1 ph in 1 ph out for balance load |
| 382 | Supply , Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 5KVA UPS 1 ph in 1 ph out for balance load |
| 383 | Supply , Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. Supply, Installation, Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 2KVA UPS 1 ph in 1 ph out for balance load |
| 384 | ELW 17.00 SOLAR SYSTEMSOLAR PLANTDesign, Engineering, Supply, Installation, Testing & Commissioning of 30 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting Fabrication along with all cables, hardware, nuts, bolts etc. |
| 385 | 4.00 ELV SYSTEMSSec.1.0 Telephone and Data NetworkingProviding and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed.25 mmas per technical specification etc. as required. |
| 386 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed.40 mmas per technical specification etc. as required. |
| 387 | Tag Blocks - Multipair Telephone Cable TerminationSupply & fixing of 50 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing. as per technical specification etc. as required. |
| 388 | Supply & fixing of 100 pair MDF unit with required modules in a fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock, provision for earthing. as per technical specification etc. as required. |
| 389 | Cabling - Multipair CablesSupplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections.(b) Armoured. (Jelly Filled)(3) Fifty Pairs.as per technical specification etc. as required. |
| 390 | Telephone / Data Networking CablingSupplying & erecting approved make LAN cable of following size in existing pipe as per direction.[C] CAT - 6as per technical specification etc. as required. |
| 391 | Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge.(8) Modem Jack for Computer Open RJ-45.Cat. III.as per technical specification etc. as required. |
| 392 | Supplying, installation, testing and commissioning of UTP CAT6 24 ports capacity gigaspeed patch panel, all ports loaded with individual RJ-45 IOs. as per technical specification etc. as required. |
| 393 | Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 7 feet as per technical specification etc. as required. |
| 394 | Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 3 feet as per technical specification etc. as required. |
| 395 | Data Networking - Fiber Optic Cable and ComponentsSupplying, installation, testing and commissioning of outdoor 6 core armoured single mode fiber optic cable for outdoor connectivity where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available etc. as per technical specification etc. as required. |
| 396 | Supplying, installation, testing and commissioning of 19\\" rack mounting type fiber shelf for assembly/termination of minimum 24 cores of singlemode ofc cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable etc. as required. Any blank adaptor positions must be suitably masked for restricting dust entry etc. as per technical specification etc. as required. |
| 397 | Supplying, installation, testing and commissioning of 19\\" rack mounting type fiber shelf for assembly/termination of minimum 12 cores of singlemode ofc cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable etc. as required. Any blank adaptor positions must be suitably masked for restricting dust entry etc. as per technical specification etc. as required. |
| 398 | Supplying, Splicing , testing and commissioning of LC type single mode pre-terminated pigtail 1mtr as per tender specification etc. as per technical specification etc. as required. |
| 399 | Supplying, Installation, testing and commissioning of LC-LC single mode duplex fiber optic patch cord 1mtr. as per technical specification etc. as required. |
| 400 | Networking Enclosures & AccessoriesSupply, Installation, Testing & Commissioning of 15U (600W X 550D)MM Wall mount closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with shelf. Casters & 2 nos vertical power strip with std etc. as per technical specification etc. as required. |
| 401 | Supplying, installation, testing and commissioning of 24U (600W X 600D)MM Floor mount closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with shelf as required . Casters & 2 nos vertical power strip with std,. as per technical specification etc. as required. |
| 402 | TYPE-2Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, minimum 2 SFP+ ports. as per technical specification etc. as required. |
| 403 | TYPE-3Supplying, installation, testing and commissioning of Layer 2 Fully manageable networking switch, 24 # 10/100/1000Tx ports, minimum 2 SFP+ ports as per technical specification etc. as required. |
| 404 | Supplying, installation, testing and commissioning of 10G SFP+ Single mode transceiver, 1310nm, 2Km, LC connector, inclusive of any hardware such as modules for populating SM-LC transceivers as per technical specification etc. as required. |
| 405 | Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with 802.11a/n/ac (5 GHz) and 802.11g/n (2.4GHz) concurrent operation with MIMO support 3x3, 3 spatial streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port, as per technical specification etc. as required. |
| 406 | Supplying, installtion, testing and commissioning of Room Wireless access point 802.11ac (2x2) Wave 2, with internal omni-directional antennas, 1 x 10/100/1000 Base-T with PoE In ( 802.3af/at ) port 4 x 10/100/1000 Base-T ports, with required licenses to compatible with Wireless controller as per technical specification etc. as required. |
| 407 | Supply, Installation, Testing and Commissioning of IP Phone with display as per tender specification etc. as required. |
| 408 | Supplying & erecting push button type telephone instrument having speaker phone Caller ID & hands free dialling system & 30 memories with display system (a) Single line |
| 409 | Sec.2.0 Video Survelance/CCTV SystemSupply, Installation, Testing & Commissioning of Vandal reistant True Day Night Veri-Focal Dome Camera 2MP, Full HD, 1/2.8 type CMOS image sensor, 2.8 -12mm motorized focus lens, Aperture Ratio F1.8, Wide Dynamic Range - 120dB, H.265 / H.264 & MJPEG dual-stream encoding, 25/30fps@1080P (1920 ×1080), IR LEDs length minimum 20 m, Motion Detection , Tampering ,Defocus detection , Hallway view ,Micro SD Card - 128GB capacity, IP66 rated, IK 10 and as per technical Specification ,The Camera must be UL Listed. as per technical specification etc. as required. |
| 410 | Supply, Installation, Testing & Commissioning of True Day Night Bullet Camera 2MP, Full HD, 1/2.8 type CMOS image sensor, Autoiris Varifocal lens 2.8 - 12mm motorized focus lens , Aperture Ratio F1.4, Wide Dynamic Range - 120dB, H.265 / H.264 & MJPEG dual-stream encoding, 25/30fps@1080P (1920 ×1080), IR LEDs length minimum 30 m, Motion Detection , Tampering ,Defocus detection , Hallway View, Micro SD Card - 128GB capacity, IP66 rated, IK 10 as per technical specification The Camera must be UL Listed, as per technical specification etc. as required. |
| 411 | Supply, Installation, Testing & Commissioning of Vandal Resistant PTZ Network Cameras ,IR with 350 Mtrs Viewing Distance 30 X Optical Zoom,camera with 1/1.9\\" sensor, 2MP, Full HD(1080p) @60fps WDR off or @15fps WDR on, H.265/H.264/MJPEG, 120dB WDR, Auto Tracking, true D/N, ,Edge Analytics - Auto Tracking, Virtual Perimeter, Entry/Exit Detection, Tampering,SD/SDHC/SDXC memory slot, 24VAC, IP66, IK10 .including all mounting accessories.The Camera must be UL Listed, as per technical specification etc. as required. |
| 412 | Supplying, installation, testing and commissioning of Client PC - Industry standard Intel based platform computer system. Intel Core i7 latest generation, 4 GB of RAM DDR3 ,1 TB SATA II hard drive for OS and VMS applications, NVidia card 1 GB graphics card , 1600 x 1200 or higher screen resolution, 1 X 1000Mbps ethernet network interface card ,16x DVD+/- RW Drive alongwith appropriate licenced Operating System, licenced applications suites from OEM and application licences as per the technical specifications etc. as required. |
| 413 | Supply installation testing and commissioning of 55\\" Full HD LED Video wall display, 3.5 mm bezel to bezel, 500 Cd/m2 brightness, DVI-D Loop out-Daisy chain, DVI- D IN X 1, VGA X 1, HDMI X 2, DVI-I Out x 1, LAN, with required mounting bracket as per site requirement. as per technical specification etc. as required. |
| 414 | Sec.3.0 Fire Detection & Alarm & Digital EVAC SystemSupplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Irrespective of whether or not mentioned in the boq, all necessary interfaces - such as hardware and software - for interconnecting all fire alarm panels at site shall be provided in the system(s).Two Loop Panel |
| 415 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 416 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. as per technical specification etc. as required. |
| 417 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. as per technical specification etc. as required. |
| 418 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. as per technical specification etc. as required. |
| 419 | Supplying, installation, testing & commissioning of addressable fire control / Monitor module complete as required. as per technical specification etc. as required. |
| 420 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. as per technical specification etc. as required. |
| 421 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. as per technical specification etc. as required. |
| 422 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Single pair, 2-core, 1.5 sqmm, For FAS & PA System |
| 423 | Sec.4.0 Access Control System“Providing & erecting approved make Fingerprint and card based premium Door controller with LCD and Keypad having following features.”(A) Optical Fingerprint and card based Reader (Card personality Module not included) “(B) Dot – Matrix LCD and Touch sense Keypad “(C) Built-in interfaces like door lock, door sense exit Reader, Exit switch, Ethernet RS485, Aux Input & aux output port “(D) 5000 Events, access Control, Time Attendance, Tamper Detection “(E) 4 LEDS and Buzzer” |
| 424 | Sec.5.0 Cable TV Distribution SystemProviding following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge.(4) TV Co-axial Socket outlet.Cat. III. |
| 425 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (b) RG – 6. |
| 426 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG – 11. |
| 427 | 05-FIRE FIGHTING WORKSupply, Installation, Testing and Commissioning of Electric driven Terrace pump suitable for automatic operation and consisting of following: complete in all respect as required.a) Horizontal, centrifugal, end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 900 lpm at 40m.head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards.c) Common Base plat for Pump and motor and coupling, coupling guard, vibration pad, cables and other accessories as required for complete installation of pump set. |
| 428 | Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pump consisting (Terrace pump - for 900 lpm)(a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price.(b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling.(d) interlocking of pressure switch with pumpsMajor component of panel are as under :MCB with DOL starterSingle phasing preventorWith push buttonOn,off, trip indication lampSpace heater with thermostateCooling exhaust fan |
| 429 | Supply, Installation, Testing and Commissioning of 150 mm dia Pressure Gauge of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of stainless steel 316 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete as required. |
| 430 | M.S. Above Ground PipeProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia. |
| 431 | M.S. Above Ground PipeProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia. |
| 432 | M.S. Above Ground PipeProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia |
| 433 | M.S. Under Ground PipeProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and laying underground including one coat of anticorrosive primer and wrapping material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process,overlap shall be maintained at 15mm as per specifications complete as required:100 mm dia. |
| 434 | M.S. Under Ground PipeProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and laying underground including one coat of anticorrosive primer and wrapping material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process,overlap shall be maintained at 15mm as per specifications complete as required:80 mm dia |
| 435 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm diaholes with stainless steel flange.100 mm dia. |
| 436 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia. |
| 437 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia. |
| 438 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI markedconforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 439 | Supply, Installation, Testing and Commissioning of Fire Hose Cabinet of size 750mmx600mx250mm fabricated from 18 swg thick MS sheet with 6mm thick glazed hinged type centre opening doors having locking arrangement suitable for accommodating 2 nos RRL hose pipes, 1 no. nozzle, branch pipe & painting with two coats of anti-corrosive primer and two coats of approved red enamel paint etc. complete as required. |
| 440 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal |
| 441 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required :Gun metal |
| 442 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired.1)20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 125852)20 mm nominal internal dia gun metal globe valve & nozzle.3)Drum and brackets for fixing the equipmets on wall.4)Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 443 | Providing and fixing standard fireman Axe with heavy duty insulated rubber handle as per IS: 926 with clamps. |
| 444 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. forsuitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe |
| 445 | Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser) |
| 446 | Supply, installation, testing and commissioning of Pump on/off Remote switches to each internal hydrant valve with required accessories. |
| 447 | Supply, installation, testing and commissioning of XLPE insulated copper armoured Cable from each Pump on/off switches to Panel with all necessary accessories. Size: 4 core x 2.5 sq. mm |
| 448 | Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. For 4.5 Kg Capacity |
| 449 | Supply, installation, testing and commissioning of ABC type 6 kg Fire Extinguisher confirm to IS:15683, with ISI marked / TAC approved fitted with required accessories including wall suspension brackets. |
| 450 | Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes:Fire Equipment: 4\\" x 12\\" |
| 451 | Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes:In case of Fire, do not use lift, use staircase: 8\\" x 8\\" |
| 452 | Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes:Fire Exit: 4\\" x 12\\" |
| 453 | Getting Approval/NOC of Fire protection system from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority. |
| 454 | 06-HVAC WORKSSUB HEAD 'MW-01' - MACHINERYSupply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 455 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 456 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 457 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 458 | INDOOR UNIT-CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System2.8 TR |
| 459 | INDOOR UNIT-CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System2.4 TR |
| 460 | INDOOR UNIT-CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System2.0 TR |
| 461 | INDOOR UNIT-CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System1.6 TR |
| 462 | In-door units INDOOR UNIT-HIGH WALL TYPESupply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.65 TR |
| 463 | In-door units INDOOR UNIT-HIGH WALL TYPESupply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.3 TR |
| 464 | In-door units INDOOR UNIT-HIGH WALL TYPESupply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1 TR |
| 465 | Central Control System(B) Central wired Remote Control System |
| 466 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(A) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 467 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(B) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 468 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(C.) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 469 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(D) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 470 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(E) 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 471 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(F) 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 472 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(G) 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 473 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(H) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 474 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(I) 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 475 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(J) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 476 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(K) 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 477 | COPPER REFRIGERANT PIPINGSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required :(L) 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 478 | Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments.(A) 2C X 1.5 Sq mm Shielded Armoured |
| 479 | SUB HEAD 'MW-02' - AIR MOVING EQUIPMENTSDesign, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor Mounted / Loft Mounted type Treated Fresh Air Units as specified below; Double Skinned with inner & powder coated outer skin of 0.6 mm PUF Sandwitched insulated sectionalized construction construction Comprising of Fan section with Fan section with best efficiency Centrifugal Fan driven by suitable pole Eff - 1 TEFC Motor with Drive Package driven by IP55 / 4P TEFC Fan Motor, fire resistant flexible fan outlet connection, The AHU shall comprise filter section with 10 micron pre filter, Cooling coil section with DX Coil Section complete with Copper tube 13 FPI AL finned 8R deep DX cooling Coils, SS 304 condensate drain pan duly insulated with 15 mm thick cross linked polymer Nitrile rubber insulation, supply air side damper & fire retardant canvass connection, necessary vibration isolation arrangement by providing spring isolators ; Motor selection to suit the below capacity for each AHU rating by AC Vendor including transmission losses. ; Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual, Status contacts for remote operation through Operating Panels, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested, UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, Temp Edit facility / Digital Temp Display) ; Prices to include dispatch of AHU in Semi-knocked down condition, assembly at site and lifting / shifting to actual locations as per layouts; Performance to be complied - common for below AHUs: Fan Exit velocity<=1800 FPM; Coil Face Velocity=500 FPM max; Filter Face=400 FPM max; dB<=60 at 1 M distance; Price shall be complete with electrical Starters for each AHU matching the motor ratings and as specified above / with AHU Kit / with alluminium anodized duct dampers for supply, return & Fresh air / Trap door / Vibration Isolators; AHU dimensions, configuration (single-tier / double-tier, top discharge / side discharge), pipe connection side & door side shall be tailor made as per final layout and space constraints. No extra claim shall be payable for such customisation; Schedule below shows.13.0 TR / 2050 CFM @ 65 mm Static Capacity for 16 HP (16 HP ODU ) |
| 480 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.1000 CFM / 40mm Static Pressure for Toilet |
| 481 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.2250 CFM / 65mm Static Pressure for Toilet |
| 482 | Floor / Loft Mounted Dry Scrubber for Kitchen ExhaustDesign, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Floor / Loft mounted cabinet type Scrubber unit with DIDW Backward curved Centrifugal fan as per specification with drive & drive package of following capacities. The unit shall be with Starter panel.7000 CFM / 50mm Static Pressure for Kitchen |
| 483 | Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity.1600 CFM / 50mm Static Pressure for Wash & Garbage Area, Dirty Dish Collection |
| 484 | Supply installation testing and commissioning of Air Washer.GI Powder coated double skinned sandwitch insulated Sectionalized Fresh Air Units; shall have Fan Section having backward curved centrifugal fan+ suitable Pole TEFC motor + drive package, Washer section with Cell deck / equivalent air wash long life cooling pad media including manufacturer supplied water distribution pad system with 2 pass PVC eliminators, manifold, Fraction HP Pumps with motor, recirculation GI / PVC piping with valves, fittings / MS corrossion proof painted Storage Sump with overflow, makeup, drain & quickfill with Ball & Float Valve assembly / Intake Filter section of 20 micron with Intake Louvers, supply side GI Dampers & canvass connections, complete with starter panel for blower fan & pump including associated outgoing cabling; Unit shall have 90% air wash efficiency & 400 FPM face velocity with 10 mm WC drop across cooling media; motor shall be selected for following fan ratings w.r.t minimum 60% volumetric efficiency; units to be mounted on vibration isolation serrated rubber pads and completely leak proof construction.Supply installation testing and commissioning of wall mounted IP 55 protection electrical starter panel for Humidifier Fan motor / Pump motors as composite unit including overload and short circuit protection, auto-manual provision, duly internally wired and tested; price shall include 10 rmt power cable of suitable size/rating from Panel upto Fan motor and Pump motors6800 CFM / 50mm Static Pressure for Kitchen |
| 485 | Supply, Installation, Testing & Commissioning of ceiling suspended type Inline Fresh Air Fan, as per specifications :1100 CFM / 25mm Static Pressure |
| 486 | Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors with VFD & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested.8000 CFM / 25mm Static Pressure for STP |
| 487 | SUB HEAD 'MW-03' - DUCTING, GRILLS, DIFFUSER AND INSULATIONSupply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(A) Thickness 0.63 mm sheet (22 Gauge) |
| 488 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(B) Thickness 0.80 mm sheet (20 Gauge) |
| 489 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(C.) Thickness 1.00 mm sheet (18 Gauge) |
| 490 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(D) Thickness 1.25 mm sheet ( 16 Gauge) |
| 491 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(A) Thickness 0.63 mm sheet (22 Gauge) |
| 492 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(B) Thickness 0.80 mm sheet (20 Gauge) |
| 493 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(C.) Thickness 1.00 mm sheet (18 Gauge) |
| 494 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(D) Thickness 1.25 mm sheet ( 16 Gauge) |
| 495 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
| 496 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers complete as per specifications and size & shape as per site requirement and approved design. |
| 497 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as per specifications and size & shape as per site requirement and approved design. |
| 498 | Supplying, fixing testing commissioning of supply air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core and size & shape as per site requirement and approved design. |
| 499 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.(A) Fire damper |
| 500 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.(B) Actuator |
| 501 | Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. |
| 502 | Supply & Installation of Under Deck Insulation with Class ‘O’ Nitrile Rubber with tough Aluminum foil facing & as per detail specifications -20mm |
| 503 | Supply & Installation of Under Deck Insulation with Class ‘O’ Nitrile Rubber with tough Aluminum foil facing & as per detail specifications -25mm |
| 504 | SUB HEAD 'MW-04' - Miscelleneous worksRigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(A) 50 mm dia. |
| 505 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(B) 40 mm dia. |
| 506 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(C.) 32 mm dia. |
| 507 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(D) 25 mm dia. |
| 508 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.(E) 19 mm dia. |
| 509 | ELEVATOR FOR BUILDING - G + 4Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift having following main features:20 passengers . G + 2 with Rated Speed of 1.5 m/sec - 1.75 m/sec with micro proce/PLC control and ACVVVF. drive, Duplex Control, Machine Room Less (MRL) - PREMIUM CATEGEROY Make : OTIS, Mitshubishi & Schindler Only (Joint Venture will not be allowed) [1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift duty 3 phase 440 V A. C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used.[2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety controls.[3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring shall be of anti skid PVC/Granite with choice of colour of engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. S.S. Hand rail at 900 mm height for all three side. Door must be clear 900 mm centre openable. [4] All landing doors shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside.[5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided.[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided inside the car and at all floors.[7] Full height infra red curtain with multiple criss / crossing light beams shall be provided.[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity.[9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open till excess load is removed.[10] Spring buffers/PU Buffers shall be provided.[11] Car fan with automatic sleep timer shall be provided.[12] Voice annunciater with suitable music shall be provided in lift car. [13] Self diagnostics system for operational and safety parameters shall be provided in control panel.[14] Mechanical over speed governor, door key holes in the floor doors, fireman switch shall be provided.[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the Contractor, along with the other steel structure works, foundations for the machine etc…[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if directed by engineer in charge.[17] Permanent wiring in lift machine room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency. Power supply of 3 phase 440 V shall be made available by department in lift machine room.[18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of lift shall be made by contractor without any extra cost.(granite/marble fixing around all landing door openings are in contractors scope.)[19] Agency has to provide all working drawings and documents and liaison services for obtaining all necessary permission from lift inspector and other authorities.[20] As per statutory requirement of Got. Of Gujarat lift & escalator act 2000, contractor has to provide 1. Car top safety barricade2. Push & talk communication system.3. Fireman's switch operation at Ground Floor |
| 510 | 08-KITCHEN EQUIPMENTS:Providing and installing Platform Trolley (DS01) of size 900 x 600 x 900 as per technical specification |
| 511 | Supplying, installing, testing and commssioning Weighing Scale (DS02) (Floor Model) of 300 kg capacity as per technical specification. |
| 512 | Providing and installing SS Dunnage rack (DS03) of size 1200 x 600 x 300 as per technical specification. |
| 513 | Providing and installing St. Steel Storage Rack (4-Shelves) (MS01) of size 1100 x 550 x 1650 as per technical specification. |
| 514 | Providing and installing Two tire trolley (kitchen utility trolley) (MS02) of size 900 x 500 x 900 as per technical specification |
| 515 | Providing and installing onion potato bin (WT01) of size 1000 x 600 x 1000 as per technical specification. |
| 516 | Supplying, installing, testing and commssioning Potato Peeler (WT02) of 20 KG Capacity as per technical specification. |
| 517 | Supplying, installing, testing and commssioning Pulverizer (WT03) of 3HP Capacity as per technical specification. |
| 518 | Providing and installing Work Table with U/s and splash back (WT04) of size 1200 mm x 600 mm x 850 mm + 150 mm as per technical specification |
| 519 | Supplying, installing, testing and commssioning Dough kneading machine (WT05) of 25kg Capacity as per technical specification. |
| 520 | Supplying, installing, testing and commssioning 2 Door vertical refrigerator (VC01) of 500L Capacity as per technical specification. |
| 521 | Supplying, installing, testing and commssioning 2 Door vertical freezer (VC02) of 500L Capacity as per technical specification. |
| 522 | Providing and installing Work table with sink , u/s and splash back (VC03) of size 1800 x 600 x 850 + 150 as per technical specification. |
| 523 | Providing and installing Work table with u/s and splashback (VC04) of size 1500 x 600 x 850 + 150 as per technical specification. |
| 524 | Providing and installing Work table with sink and splashback (VC05) of size 1100 x 600 x 850 + 150 as per technical specification. |
| 525 | Providing and installing Side table with u/s and splashback (CK01) of size 600 x 750 x 850 + 150 as per technical specification. |
| 526 | Supplying installing, testing and commssioning Single Burner Indian Cooking Range (CK02) of size 600 x 600 x 450 as per technical specification. |
| 527 | Providing and installing Side table with u/s and splashback (CK03) of size 1000 x 750 x 850 + 150 as per technical specification. |
| 528 | Supplying installing, testing and commssioning Kadhai Fryer (CK04) of size 600 x 600 x 750 as per technical specification. |
| 529 | Supplying, installing, testing and commssioning Chapati plate puffer (CK05) of size 1500 x 600 x 850 as per technical specification. |
| 530 | Providing and installing Marble top chapati rolling table (CK06) of size 1800 x 600 x 850 as per technical specification. |
| 531 | Providing and installing Support table with u/s and splash back (CK07) of size 1800 x 600 x 850 + 150 as per technical specification. |
| 532 | Providing and installing Masala Trolley ( 8nos 1/6 GN Pan ) (CK08) of size 850 x 500 x 900 as per technical specification |
| 533 | Providing and installing Dosa Plate (CK09) of size 1000 x 600 x 850 as per technical specification |
| 534 | Providing and installing Side table with u/s and splashback (CK10) of size 600 x 600 x 850 + 150 as per technical specification. |
| 535 | Providing and installing Idli steamer with Boiler plant (CK11) of 120 Idli capacity as per technical specification. |
| 536 | Providing and installing thali counter with service rail and sneeze guard (SR01) of size 1200 x 650 + 300 x 850+450 as per technical specification. |
| 537 | Providing and installing Bain marie with 4Nos hot 1/1 GN pan, 1Nos ambient 1/1 GN pan,service rail and sneeze guard (SR02) of size 2200 x 650 + 300 x 850 + 450 as per technical specification. |
| 538 | Providing and installing Soiled dish table with scraping hole (DW01) of size 2100 x 750 x 900 as per technical specification. |
| 539 | Providing and installing Two sink pre-wash unit (DW02) of size 1800 x 750 x 900 as per technical specification. |
| 540 | Providing and installing Pre-rinse shower (T & S or equivalent make) (DW03) as per technical specification. |
| 541 | Supplying, installing, testing and commssioning Hood type dish washer machine (Electrolux or equivalent make) (DW04) of capacity 80rack/ hr as per technical specification. |
| 542 | Providing and installing Clean dish landing table (DW05) of size 1200 x 750 x 900 as per technical specification. |
| 543 | Providing and installing 4 shelves Clean dish storage rack (DW06) of size 1100 x 550 x 1650 as per technical specification. |
| 544 | Providing and installing Waste bins of 80 Ltr. Capacity (Garbage bin - Nilkamal) (DW07) as per technical specification. |
| 545 | Providing and installing SS Drain trough with perforated basket and pipe gratings (FD01) of size 1200 x 600 x 100 as per technical specification. |
| 546 | Supplying, installing, testing and commssioning Hosereel (FD02) of capacity 15m as per technical specification. |
| 547 | Supplying, installing, testing and commssioning Exhaust Hood with Baffle filter (EX01) of size 1500 x 900 x 500 as per technical specification. |
| 548 | Supplying, installing, testing and commssioning Exhaust Hood with Baffle filter (EX02) of size 750 x 900 x 500 as per technical specification. |
| 549 | Supplying, installing, testing and commssioning Exhaust Hood with Baffle filter (EX03) of size 1000 x 900 x 500 as per technical specification. |
| 550 | Supplying, installing, testing and commssioning Exhaust Hood with Baffle filter (EX04) of size 600 x 900 x 500 as per technical specification. |
| 551 | Supplying and installing GI Ducting for Exhaust Air as per technical specification. |
| 552 | Supplying and installing GI Ducting for Exhaust Air with air grill as per technical specification. |
| 553 | Supplying, installing, testing and commssioning Exhaust air blower of 7000 CFM as per technical specification. |
| 554 | Supplying, installing, testing and commssioning Fresh air blower of 4200 CFM as per technical specification. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail