| 1 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50M including all lift, leveling ramming the foundation trenches, removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Providing coarse clan local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per buiding specification and direction of E/I. (Mode of measurement compacted volume) |
| 3 | Providing designation 75-B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing designation 75 B brick work in C.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10mm thick mortar joints, cost of screening, materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 8 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).Total Qty. (A+B+C+D+E+F) |
| 10 | Providing designation 75 B brick work in C.M (1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 11 | Providing 125 mm thick Reinforced designation 75 A brick work in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening, carriage of materials, racking our joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification & direction of E/I. |
| 12 | Providing and fixing fan hok of 16mm dia M.S bar 1 meter long bent of required size and shape, placed in position and fixed in R.C.C slab/beam at the time of casting all compete as per building specification and direction of E/I. (where material is not supplied by deppt.) 1 meter length |
| 13 | Providing 12 mm think, cement plaster (1:6) on inside walls with clean coarse sand of F.M 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification & direction of E/I. |
| 14 | Providing 6 mm think, cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification & direction of E/I. |
| 15 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxea and royalty all complete as per building specification of E/I. |
| 16 | Providing Tor Steel Reinforcement of following dia Rods as per approved design and drawing including carriage of M.S Rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing thethe rods in position all complete as per building specification and direction of E/I (Fe 500) 8 mm dia 50% |
| 17 | 10 mm |
| 18 | 12 mm to 16mm |
| 19 | Providing and fixing pressed steel door frames confirmig to IS: 4351 manufactured form commercial mild steel sheet of 1.25 mm thickness including hinges jomb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by machenical means, adjustable lugs with split end tail to each jamb including steel but hings 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by E/I.Profile - B |
| 20 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame-do-do- with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick plan PVC doors |
| 21 | Supplying, fitting and fixing 35 mm thick solid core type decorative single leaf flush shutter in doors with both side non-decorative veneered with black board core blended with high quality phenol formaldehyde synthetic resin both side commercial veneered of standard make with oxidized iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction E/I. |
| 22 | Providing and fixing factory made P.V.C door frame manufactured by M/s Raj Shri or equivalent of size 50X47 mm with a wall thickness of 5mm made out of extruded 5mm rigid PVC foam sheet mitered at corners ---------- complete as per manufacturers specification and direction of E/I. |
| 23 | Supplying, fitting and fixing fully glazed steel, door, windows or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100x16x3mm M.S lugs fixed in cement concrete (1:2:4) blocks 15x10x10cm, size including cost of oxidised iron fitting, with hinges, handel per steps, catch springs, 3mm thick plain glass panes with Aluminum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I counter sunk machine screw and nuts and applying a coat of red lead paint carriage of work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I. |
| 24 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20x10x2mm at 100mm centres and braced with M.S flat diagonals 20x3mm, with top and bottom rails of T. iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint, carriage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 25 | Supplying, fitting and fixing M.S grill made of 20x6mm M.S flat as per approved design and drawing, properly fabricated with joints continuous filled welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials in not supplied by the deppt.) |
| 26 | Providing G.I pipe hand rails with 40mm G.I pipe of I.T.C or equivalent make properly fitted and fixed in position to rail posts with all necessary accessories and taxes all complete as per building specification and direction of E/I. |
| 27 | Providing and laying polished vitrified floor tiles in different size (thickness to be specified bythe manufacture) with water apsorption less 0.08% and confirming to IS: 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 coarse sand) including grouting the joint with white cement and maching pigment etc.600X600cm. |
| 28 | Providing and laying polished vitrified floor tiles in different size (thickness to be specified bythe manufacture) with water apsorption less 0.08% and confirming to IS: 15622 of approved make in all colours and shades, in skirting, riser of steps over 12 mm bed of cement mortar 1:3 (1 Cement: 3 coarse sand) including grouting the joint with white cement and maching pigment etc.600X600cm. |
| 29 | Providing and fixing 25 mm thixk white makrana marble tiles in risers of step, skirting and pillars of approved quality over 12 mm thick base of cement mortar (1:3) and jointed with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 30 | White \\"A\\" grade white 15x15 cm tiles. In walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush jointed with white cement including rubbing, polishing and cost of curing taxes and royalty all complete as per building specification and direction of E/I. |
| 31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete |
| 32 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all completed as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 33 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumic stone or fine sand paper applying putty wherever required, scaffolding washing of floors and taxes all complete as per building specifications and direction of E/I. |
| 34 | Providing and applying plaster of paris 2 mm thick over plastered surface to prepare surface even & smooth. |
| 35 | Providing applying 2mm thick wall putty on external surface over plastered surface to prepare the surface even and smooth complete |
| 36 | Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade New work (two or more coats applied @ 1.43 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 37 | Providing two coats of synthetic Enamel Paint of approved shade and make over new Wooden surface including preparing the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification and direction of E/I. |
| 38 | Providing Primer one coat of red lead paint of approved make over New Steel Surface including preparing the surface after cleaning removing dirt, rust scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding all taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification). |
| 39 | Providing and fixing on wal face unplasticized rigid P.V.C rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion.(1) single socketed pipes.100 mm diameter |
| 40 | Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.110 mm bend |
| 41 | Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.110 mm shoe |
| 42 | Making plinth protection with Bricks class designation 75 laid on edge in cement mortar (1:6) with 12mm thick bed to cement mortar (1:6) over 75mm bed of dry brick aggregate 40mm nominal size, rammed, consolidated and grouted with fine sand and the top of bricks jointed with cement mortar (1:2) as per direction of E/I |
| 43 | Providing 1.5 mm thick cement punning including curing carriage of water with all leads and lifts as per building specification and dierection of E/I. |
| 44 | Providing 250 mm wide brick drain in cement mortar (1:6) with av 150 mm clear depth and 250 mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 45 | Centering and shuttering including strutting, propping etc. and removal of form for Centering and shuttering including strutting, propping etc. and removal of form for |
| 46 | Suspended floors, roofs, landings, balconies and access platform |
| 47 | Shelves (Cast in situ) |
| 48 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 49 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 50 | Weather shade, Chajjas, corbels etc., including edges |
| 51 | Carrige of Materials:Bricks lead 15 Km |
| 52 | Sand Lead 20 Km |
| 53 | Stone chips Lead 50 Km |
| 54 | Sanitary WorkSupplying fitting and fixing viterous white glazed earthen ware I.W.C of parry/Hindustan of any other I.S.S. approved make 100 mm H.C.I 'P' trap 15 litre C.I pull and let go flushing system of names or other I.S.S Equivalent make complete with all fitting C.I. or C.C brackers 32 mm alkathene/PVC telescopic flush pipe about 2 m long with one brash coupling and clams G/I chain and pull including supplying and fixing a pair of viterous white glazed earthenware ware footrest to be fixed in floor 15 mm C.I. body brass spindle stope cock of weight not less than 50 gms 15mm P.V.C connection pipe 450mm long abd tge exposed pipe and cistern with two coats of approved paint over a coat or red oxied primer etc. all complete as per specification and direction of E/I.580x440mm with 10.00 litre low level PVC Cistern |
| 55 | Providing & fixing salem stainless steel A ISI 304 (18/8) Kitchan sink as per IS 13983 with e.i. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls whereever required 19.10 A 2 2-510x1040 bowl depth 250 mm |
| 56 | Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S approved make supported on pointed C.I. or R.s. (32 M.C.I brass west 15 mm dia C.I body brass spindle cock of approved quality of weight not less than 350 gms 32 mm P.V.C waste pipe 750 mm long with brass coupling at one end and making plumber join etc. all complete as per specification and direction of E/I. |
| 57 | Providing and fixing C.P brass bib cock of approved quality confirming to IS-8931-15 mm dia nominal bore approved brand C.P. fittings |
| 58 | Providing and fixing PTMT extention nipple for water tank pipe, fitting and approved quality and colour, 15mm nominal bore, weighing not less than 32gms |
| 59 | Supplying labour & tools for fixing C.P.V.C. Pipe with red lead and yarn of following normal bore with screwed and socketed joints on walss ceiling and floor including supplying and fitting of wall hooks or pipes clamps, wooden plug cutting pipe of size and threading ends if required etc. all complete as per specification and direction of E/I. (pipe with socket to be supplied department entally free of cost) a. 15 mm nominal bore |
| 60 | b. 20 mm nominal bore |
| 61 | c. 25 mm nomional bore |
| 62 | Supplying & fittings gun metat following valve of approved quality, all complete as per approved design, drawing, building & PHED specification and direction of E/I. 20 mm dia |
| 63 | Providing and fixing brass stop cock of approved quality with taxes, all complete as per approved design, drawing, building & PHED specification and direction of E/I.15 mm dia- |
| 64 | Providing and placing on terrace (at all flor levels) polyethlylene water storage tank ISI: 12701 marked indicating the BIS license No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but with. |
| 65 | Supplying fitting and fixing PVC, pipes with ear of approved make confirming to I.S.I 1729 including supplying nails and bobins short pieces, cutting loose collars lead and yarn for making lead chaulked joints, cutting pipes to size including(a) 110 mm dia |
| 66 | Supplying and fixing PVC fitting of approved make confirming to I.S.S 1729 including supplying and bobins lead and yarm for making lead chaulked joints including earth work or providing scaffolding as the case may be all complete as per specification & direction of E/I. (H) PVC plain Band with ear and door.(i) 110 mm bend |
| 67 | (H) PVC plain Tee 100 mm dia |
| 68 | Provding and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gape for thermal expansion.(i) 100 mm dia door tee |
| 69 | Suppying and materials with labour for construction inspection chamber of designation class 75B brick deep 600x450 mm internal dismention haing 250mm wall thickness in cement morter (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x450mm G.I cover with frame (weight not less than 36Kg) along with P.C.C (1:3:6) in foundation and refilling all complete as per approved design, drawing, building & PHED specification and direction of E/I |
| 70 | Cowel |
| 71 | Steel jali |
| 72 | Floor trap |
| 73 | Pressure asjustable shower with revolving joints |
| 74 | Cost of construction of 1 no. septic tank as per detailed estimate enclosed |
| 75 | WGPVT- Wiring for light/point/fan point/Exhaust fan point/call bell point with 1.5 Sq.mm F.R P.V.C insulated copper conductor cable in surface / recessed P.V.C conduit as required. with piano type switch phenolic laminated sheet M.S Box earthing the point P.V.C insulated copper with 1.5 Sq.mm with taxes all complete as per approved design drawing, building & Electrical specification and direction of E/I.1.1.2-Group-B |
| 76 | 1.1.3-Group-C |
| 77 | PTSWEB- Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required with taxes, all complete as per approved design, drawing, building & Electrical specification and direction of E/I.1.24.1-5/6 amps switch |
| 78 | 1.24.4-3 pin 5/6 amps socket outlet |
| 79 | WGPVCPP2- Wiring for light/power plug wiring with 2x4 sq.mm F.R PVC insulated copper conductor single core cable in surface/ recessed P.V.C conduit along with 1 No. 4 sq mm FR PVC insulated copper wire for loop earthing etc. as required with taxes, all complete as per approved desgin drawing building and electrical specification and direction of E/I. |
| 80 | WGPVCSB- Wiring for sub-main wiring with following size of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit etc. as required with taxes all complete as per approved design, drawing, building & Electrical specification and direction of E/I. 1.7.2-2x2.5 sq. mm earth wire |
| 81 | 1.7.4-2x6 sq mm earth wire |
| 82 | PPACCPT- Supplying and fixing metal box of 180 mm X 100 mmX 60 mm deep (nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required with taxes all complete as per approved design, drawing, building & Electrical specification and direction of E/I. |
| 83 | MCBB- Supplying and fixing 5 amps to 32 amps, rating, 240 volts, ‘L’ series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing the commissioning etc. as required with taxes, all complete as per approved design, drawing, building & Electrical specification and direction of E/I. category B 6/32 amps single pole |
| 84 | 2.11.2- 40 amps single pole and neutral |
| 85 | SPMCBDBCO- Supplying and fixing of following way single pole & neutral, sheet steel, MCB distribution board consumer unit, 240 volts, on surface/ recess, complete with tinned copper bushbars, neutral busbar, earth bar, din bar, hinged front Acrylic cover for the MCB knobs detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as required with taxes, all complete as per approved design, drawing, building & Electrical specification and direction of E/I. (with set RCCb/lsoator)2+8 way- |
| 86 | S/F plug in box supplying, installing, testing & commissioning of TPN plug in box of following capaity on existing overhead busbar system complete with HRC fuse links, electrical interconnecting, earthing etc. As required63 amps |
| 87 | Supplying and fixing following rating TP&N (three phase & neutral) 415 voltsresidual current circuit breaker (RCCB),having a sensitivity current up to 300 milliampers in the MCB DB complete with connections,testing and commissioning ect as required With HRC fuses including grilling holes on the board connection earthing the body etc. as required 2.17.3-63 amps. AP&N |
| 88 | ITC ceiling fanInstallation, testing, and commissioning of resistance type ceilling fan regulator in existing switch box including conection with 1.5 sq.mm FRPVC insulated copper conductor, single core cable earthing the regulator etc, as required. |
| 89 | EARPIPCHAR- Earthing with GI earth pipe 4.5 mtr long 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt etc. As required with taxes, all complete as per approved design, drawing building and Electrical specification and direction of E/I. |
| 90 | EAR8GCUWR Supplying & laying 8 SWG copper wire at 0.50 mtr below ground level for conductor earth elecode including soldering etc. As required with taxes as per approved design, drawing, building and Electrical specification and direction of E/I. |
| 91 | LCFCU - Providing, fitting of lighting conductor finaial made of 25 mm dia 300 mm ling etc as required with taxes all complete as per approved design, drawing, building & electrical specification and direction of E/I. |
| 92 | LCRESS - Riveting sweating and soldering of copper/ GI tape (with another copper/G.I tape base of the finial or any metallic object) as required all complete as per approved design, drawing building & electrical specification and direction of E/I. |
| 93 | LCGITSURH - Providing fitting of G.I tape 20 mm x 3mm thick on paraper or surface of wall for horizontal for lightening conductor all complete as per approved design, drawing, building & electrical specification and direction E/I. |
| 94 | LCGITSURV- Providing fitting of G.I tape 20 mm x 3mm thick on paraper or surface of wal for vertical for lighting conductor all complete as per approved design, drawing buiding & electrical specification and direction of E/I. |
| 95 | Supplying and fixing of 20/22 W tube light fitting single box type with tube |
| 96 | Supplying and fixing of 120W LED Street Light and all acessories etc. |
| 97 | Supplying and fixing Down light 12W |
| 98 | Supplying and fixing ceiling fan 48\\" dia |
| 99 | Drilling of Tube Well in all kinds of soil 125 MM Dia |
| 100 | Drilling beyond 51 to 125 mtr upto 60 mtr below G. L. |
| 101 | Supplying all tools , equipment and labour and doing washing ,flushing and development of drilled tube well |
| 102 | Supplying all tools tackles & lowering of 200 mm UPVC casing pipe etc . All complete as per specification & direction of E/I |
| 103 | Supplying labour and equipment including 200 mm dia G.I.Cap All complete as per specification & direction of E/I |
| 104 | Basic Rate of 32mm G.I. Pipe in 3 mtrs lenth (medium) with seamless socket |
| 105 | Supply Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283 pump shall be suitable |
| 106 | Supplying , Flate flexible submersible cable with ,copper conductor ,PVC insulated and PVC sheathed as per IS 7098 3 core 4 sq. Mm |
| 107 | D. L. O. Starter with SS Enclosure with 380/415 Volt coil as per IS 3914 |
| 108 | Earthwork in excavation in foundation trenches in hard soil (vide classification of soil item-B) and disposal of excavated earth as obtained to a distance up to 50 M. including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 109 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 110 | Providing and laying 80 mm thick paver block of m-30 gradein all complete as per building specification and direction of E/I. |
| 111 | Providing P.C.C.M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 112 | Carriage of materialsA.Sand:-(lead-20 km) |
| 113 | B.stone chips :- (lead -50 km) |
| 114 | C.paver :-(lead -30 km) |
| 115 | Centering and shutteringFdn |
| 116 | G.S.T. @ 18% |
| 117 | Labour Cess @ 1% Please Enable Macros to View BoQ information |