| 1 | Civil work: |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.(CSI No. 15.7.1) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.(CSI 2.6.1) |
| 4 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.(CSI NO. 2.25(A)) |
| 5 | 4 cm thick 1::2:4 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC (OLD CSI 12.04) |
| 6 | Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost), coarse sand and cement in proportion of 12:6:1 in foundations and under floors, including cost of all labour, materials, T&P etc required for proper completion of work.(CSI NO. 29.1) |
| 7 | Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. CSI NO. 6.18) |
| 8 | Brick work in superstucture with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. CSI NO. 6.19) |
| 9 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(CSI 10.2) |
| 10 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI 4.2.2) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers(CSI 5.9.5) |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.(CSI NO. 6.13.2) |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars(CS I 5.22.1) |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI 4.1.2) |
| 15 | P/F fully Anodized aluminium fixed glazing with HINDALCO or equivalent extruded standard sections14gauge (2.41mm thick) of various cross sections and joints mitred and jointed as shown in drawing including providing & fixing 5.5 mm thick toughened glass with Neoprene beading & aluminium glazing clips all around. The minimum thickness of anodizing on all aluminium sections should be 20 microns with a (+) 2 microns tolerance . The rate should include the cost of fixing the aluminum frame on Teak wood frame or finished wall (RB/RCC/Masonry) surface by means of 80 mm long approved counter sunk screws provided at 500 mm c/c or part there of starting from 100 mm above the bottom in vertical member and 100 mm from both the ends of horizontal top and bottom member excluding cost of Teak frame but including cost of all other material, labour, tools & plants etc. complete. (OLD CSI No. 8.52) |
| 16 | Providing & fixing 5.5 mm thick glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :(CSI NO. 10.30.2) |
| 17 | Same as above item No. 8.52 but for openable window portion as shown in drawings, including cost of Aluminium hinges and all other fittings like concealed tower bolts handles etc of approved quality and including cost of all other material, labour, tools & plants etc. complete. (OLD CSI No. 8.53) |
| 18 | Same as in item No. 8.52 but for openable gate/door portion as shown in drawings including cost of hinges and Aluminium fittings like tower bolts, handles, stoppers, push plates, brass body with brass component 6 levers cocealed lock etc of heavy & approved quality and including cost of all other material, labour, tools & plants etc. complete. (OLD CSI No. 8.54) |
| 19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(CSI 13.80) |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.(CSI 13.41.1) |
| 21 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (CSI 13.45.1) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (CSI 13.62.1) |
| 23 | Providing and fixing on wall face unplasticised Rigid 110 mm diameter PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(CSI 12.41.2) |
| 24 | Providing and fixing on wall face unplasticised Rigid 75mm diameter PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(CSI 12.41.1) |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C(CSI NO. 28.3) |
| 26 | Wiring point for plug with 1 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 134-C) |
| 27 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD 1139) |
| 28 | Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD 216-C) |
| 29 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.(NSI) |
| 30 | 12 mm cement plaster of mix :1:6 (1 cement: 6 course sand) external plastic are for height upto 10m from ground level in less otherwise stated.(CSI 13.4.2) |
| 31 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 32 | S&F of 6 Amp to 32 Amp. MCB (10 KA) (PWD C.S.I. No. 1011-CAT B) |
| 33 | S&F of 63 Amp. DP MCB (10 KA) C Curve. (PWD C.S.I. No. 1002-CAT B) |
| 34 | S&F of 63 Amp. DP ISOLATOR. (PWD C.S.I. No. 1005-CAT B) |
| 35 | Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.(OLD CSI No. 28.39) |
| 36 | S/R of regulator for ceiling fan of GEC or equivalent make including cost of all labour material, T&P etc. required for proper completion of the work. ( CSI 22.60b) |
| 37 | Engaging of One no Beldar for misc. work such like shifting of Almirah,Furniture etc.as per required of site (CSI NO. 1.2+10%CP) |
| 38 | Supply and wiring of 4 number 10 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy gauge rigid steel conduit concealedin wall ,with two number 10 SWG copper earth continnuity wire including matching colour wash etc , complete in all respect. (PWD 273-B) |
| 39 | Supply and wiring of 2 number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit concealedin wall ,with two number 10 SWG copper earth continnuity wire including matching colour wash etc , complete in all respect. (PWD 217-B) Please Enable Macros to View BoQ information |