| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil. |
| 2 | Providing and laying of stone soling (Hand Packed) including ramming, dressing and watering all complete.(Incl. all sorts of carriage). |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal) crushed. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with in 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. As per direction of Engineer Incharge at Site. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 10 | Foundations, footings, bases of columns etc. for mass concrete. |
| 11 | Suspended floors, roofs, landings, balconies and access platforms. |
| 12 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) in superstru cture above plinth level upto floor five level as per direction of Engineer Incharge at site including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 13 | CEMENT PLASTER (IN FINE SAND) 15mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand) Internal |
| 14 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 15 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate. |
| 16 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Kiln seasoned and chemically treated hollock wood |
| 17 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm Thick float glass panes including ISI Marked M.S Pressed butt hinger bright finished of required size with necessary screwa 35mm thick kiln seasoned & chemically treated hollcock wood as per direction of Engineer Incharge at Site. |
| 18 | Providing and fixing float glass panes 3mm thick glass pane ( Weighting not less then 10kg/Sqm |
| 19 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade |
| 20 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm). |
| 21 | Providing and fixing ussing ISI Marka aluminium hardware fittings as per direction of Engineer Incharge at site complete job |
| 22 | L drop with lock |
| 23 | Tower bolt 150mm x 10mm |
| 24 | Tower bolt 100mm x 10mm |
| 25 | Handle 125mm |
| 26 | Handle 100mm |
| 27 | Hooks |
| 28 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded as per direction of Engineer Incharge at site complete job. |
| 29 | Providing and fixing with High rib colour profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks, fixed with polymer coated Jor L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)including the cost of purlins, rafters including ridges/valley/hips 0.50mm thick |
| 30 | Providing and fixing of 12mm thick ply board ceiling in class rooms including cost of nails and 25mm thick wooden cornice but excluding cost of supporting structure as per direction of Engineer incharge at site |
| 31 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed inposition : Kiln seasoned and chemically treated hollock wood |
| 32 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) / steel. Including all cost and carrige complete Job |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 34 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 35 | Lighting point One Lighting point shall incl. wiring for lighting points in 1.5 Sq.mm PVC insulated Copper wire & 2.5 Sq.mm PVC insulated multi-strand Copper wire for lighting Sub-mains, 6 Amp one way switch, 2 mm thick PVC conduit / Channel with bends, Junction boxes etc, 6 Amp S Pole MCB, 10 Amp DP MCB, 2 way DB for Housing MCB and Hyle Sheet with wooden box recessed in walls with accessories |
| 36 | Heating points One Heating point shall incl. wiring for heating points in 2.5 Sq.mm PVC insulated Multi-Strand Copper wire & 4 Sq.mm PVC insulated multi-strand Copper wire for heating Sub-mains, 16 Amp switch socket combined, 2 mm thick PVC conduit/Channel with bends, Junction boxes etc, 10 Amp S Pole MCB, 2 way DB for Housing MCB and Hylem Sheet with wooden box recessed in walls with accessories. |
| 37 | Fan points One Fan point shall incl. wiring for Lighting points in 1.5 Sq.mm PVC insulated Multi-Strand Copper wire, 1200 mm ceiling fan/225 mm exhaust fan with ceiling roses & PVC Square block, 350 Watts electronic fan dimmer, 2 mm thick PVC conduit / Channel with bends, Junction boxes etc, 6 Amp S Pole MCB, 10 Amp DP MCB, 2 way DB for Housing MCB for lighting circuits and Hylem Sheet with wooden box recessed in walls with accessories |
| 38 | Providing, fixing and supplying of service line complete job as per ditection of engineer incharge at site |
| 39 | Providing, fixing and supplying of Control pannel complete job as per ditection of engineer incharge at site |
| 40 | Carriage of materials by Mechanical Transport including loading, unloading and stacking complete job |
| 41 | Sand lead upto 50 km. |
| 42 | Stone aggregate upto 50 km. |
| 43 | Bricks upto 110 km. |
| 44 | Carriage of materials by head load including loading, unloading and stacking complete job |
| 45 | Sand lead upto 0.200 km. |
| 46 | Stone aggregate upto 0.200 km. |
| 47 | Bricks upto 0.200 km. |
| 48 | Taking of Geo Tag Photographs of size 125mmx250mm before execution, during execution and after execution of work (04 No. Each Pre, Post, After execution) to be submitted with the bill complete job. (Geo Tag Photographs showing Name of Work, Location and Longitude/ Latitude).(Pre, Post, After execution). Please Enable Macros to View BoQ information |