| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil/Boulders. |
| 2 | Providing and laying of stone soling/ GSB Nallah Muck /Quarry Muck or 2nd class sand in foundation treches/inside plinth including ramming, dressing and watering all complete job as per direction of Engineer Incharge at Site. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal) crushed. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 10 | Foundations, footings, bases of columns etc. for mass concrete. |
| 11 | Lintel, beams, plinth beams, girders, slab, bressumers and cantilevers. |
| 12 | Suspended floors, roofs, landings, balconies and access platforms. |
| 13 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. including all cost and carriage complete job |
| 14 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand). |
| 15 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 16 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate. |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners KD/Silver wood). including all cost and carriage complete job |
| 18 | Providing and fixing glazed shutters for doors, windows and clerestory windows using ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. KD kail wood |
| 19 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes |
| 20 | Distempering with dry distemper of approved brand and manufacture (twoor more coats) and of required shade on new work, over and includingwater thinnable priming coat to give an even shade |
| 21 | Finishing walls with water proofing cement paint of required shade onNew work (two or more coats applied @ 3.84 kg/10sqm) |
| 22 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 100x10mm |
| 23 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete.150x10mm |
| 24 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992with necessary screws etc. complete :100 mm |
| 25 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992with necessary screws etc. complete : 125 mm |
| 26 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with nuts and screws etc. complete : 250x16 mm |
| 27 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 28 | Providing and fixing with High rib colour profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks, fixed with polymer coated Jor L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)including the cost of purlins, rafters including ridges/valley/hips 0.50mm thick |
| 29 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 31 | Supplying , laying, testing as commissioning of 25mm dia PVC high class unbreackable heavy duty conduits to be laid in RCC slab and walls inculding cutting the walls making good the same including cost of accessories like bends and heavy gauge sheet steel deep junction all complete job as per direction of Engineer Incharge at site |
| 32 | Lighting point One Lighting point shall incl. wiring for lighting points in 1.5 Sq.mm PVC insulated Copper wire & 2.5 Sq.mm PVC insulated multi-strand Copper wire for lighting Sub-mains, 6 Amp one way switch, 2 mm thick PVC conduit / Channel with bends, Junction boxes etc, 6 Amp S Pole MCB, 10 Amp DP MCB, 2 way DB for Housing MCB and Hyle Sheet with wooden box recessed in walls with accessories |
| 33 | Heating points One Heating point shall incl. wiring for heating points in 2.5 Sq.mm PVC insulated Multi-Strand Copper wire & 4 Sq.mm PVC insulated multi-strand Copper wire for heating Sub-mains, 16 Amp switch socket combined, 2 mm thick PVC conduit/Channel with bends, Junction boxes etc, 10 Amp S Pole MCB, 2 way DB for Housing MCB and Hylem Sheet with wooden box recessed in walls with accessories. |
| 34 | Fan points One Fan point shall incl. wiring for Lighting points in 1.5 Sq.mm PVC insulated Multi-Strand Copper wire, 1200 mm ceiling fan/225 mm exhaust fan with ceiling roses & PVC Square block, 350 Watts electronic fan dimmer, 2 mm thick PVC conduit / Channel with bends, Junction boxes etc, 6 Amp S Pole MCB, 10 Amp DP MCB, 2 way DB for Housing MCB for lighting circuits and Hylem Sheet with wooden box recessed in walls with accessories |
| 35 | Carriage of materials by Mechanical Transport including loading, unloading and stacking complete job: |
| 36 | Sand lead upto 30 km. |
| 37 | Stone aggregate upto 30 km. |
| 38 | Bricks upto 75 km. |
| 39 | Taking of Geo Tag Photographs of size 125mmx250mm before execution, during execution and after execution of work (04 No. Each Pre, Post, After execution) to be submitted with the bill complete job. (Geo Tag Photographs showing Name of Work, Location and Longitude/ Latitude).(Pre, Post, After execution). Please Enable Macros to View BoQ information |