Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Main Building |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) all complete. |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil : |
| 4 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 8 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level including curing, excluding the cost of centring, shuttering, and finishing.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) all complete. |
| 9 | Providing and laying chisel dressed Devri Stone (Ashler/ Green/ Grey)/Cornice/Moulding local stone of required size with 50 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing One face dressed Rough chisel dressed incl. necessary plaster incl. all carriages etc complete |
| 10 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet all complete. |
| 11 | Providing and fixing of 0.50mm thick colour coated Hi-rib G.S sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, incl. a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto any pitch in horizontal/ vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including hips, ridges, valleys all complete Red Colour. |
| 12 | Providing, hosting and fixing trusses/ purlins/ rafters/post-plates or like components incl. cost of screws etc complete Popular Wood complete in all respects. |
| 13 | Providing and fixing of ornamental second class Kashmiri Local Deodar wooded eaves boarding 300x30mm (nominal size) with required carving as per the approved/available pattern and design (Including cost of nails,polish with sealer over prepared base/finishing) to be approved by EIC. Finishing work to be approved by EIC. |
| 14 | Providing and fixing of KHATAM BANDI ceiling of first class kashmiri local budloo/fir wood incl. the cost of frame work , Heritage pattern and design to be appoved by EIC Pahal Gardan |
| 15 | Providing and fixing of 10mm thick commericial plywood incl. cost of nails/screws all complete job (Frame work shall be paid seperately). |
| 16 | Providing & fixing of 12 mm thick Nordic pine wall wooden Panelling(T&G)/tiles/as per the required design over the walls incl. cost of necessary fitting, scfrews etc including polishing with PU glossy polish with base sealer as per the directions at site complete job |
| 17 | French spirit polishing, Two or more coats on new works including a coat of wood fille all complete. |
| 18 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to thedumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand) all complete. |
| 19 | Stone work (machine cut edges) for wall lining/cornice/moulding etc. (veneer work) upto 10 m height, backing filled with a grout of average 12 mm thick cement mortar 1:3 ( 1cement: 3 coarse sand) including pointing in white cement mortar 1:2 ( 1 White cement: 2 stone dust) with an admixture of pigment matching the stone shade and curing complete.White sand stone - Exposed face machine cut and table rubbed with rough backing.(20-30mm thick) all complete as per directions of EIC. |
| 20 | Stone/tile adhesive for fixing of tiles and stone cladding all complete. |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood all complete. |
| 22 | Providing and fixing 35 mm glazed shutters for doors, windows and clerestory windows using 5 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws and fitting like tower bolt, handles etc all job complete. First class kail wood all complete. |
| 23 | Providing and fixing 35 mm wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws and fitting like tower bolt, handles etc all job complete as per direction of Engineer-in-charge . First class kail wood all complete. |
| 24 | Providing and fixing 35 mm panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, including panelling and fitting like tower bolt, handles etc and carving designing on the door all job complete, all complete as per direction of Engineer-in-charge:First class Kail wood all complete. |
| 25 | Applying Pu polish on new wood works including wood filler coat if required. |
| 26 | Dismantling wood work in frames, trusses, purlins and rafters upto 10meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above. |
| 27 | Carriage of Material: Sand for an avg. lead of 15 Kms |
| 28 | Stone Agg. for an avg. lead of 15 Kms |
| 29 | Shiv Temple and Hawan Kund |
| 30 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 31 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 32 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete. |
| 33 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete. |
| 34 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level including curing, excluding the cost of centring, shuttering, and finishing.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) all complete. |
| 35 | Providing and laying of GSB under Floors including , watering , ramming,dressing in layers incl. all leads, lifts, carriage etc all complete |
| 36 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. (kit-Ply/Steel Plates). |
| 38 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level all complete. |
| 39 | Tile brick masonry with common burnt clay tile bricks of class designation 10 in foundation and plinth including curing complete in: Cement mortar 1:4 (1 cement : 4 coarse sand) all complete. |
| 40 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate all complete. |
| 41 | Providing and laying chisel dressed Devri Stone (Ashler/ Green/ Grey)/Cornice/moulding local stone of required size with 50 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing One face dressed Rough chisel dressed incl. necessary plaster incl. all carriages etc complete |
| 42 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
| 43 | Providing and fixing 35 mm glazed shutters for doors, windows and clerestory windows using 5 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws and fitting like tower bolt, handles etc all job complete. First class kail wood. |
| 44 | Providing and fixing 35 mm wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws and fitting like tower bolt, handles etc all job complete as per direction of Engineer-in-charge . First class kail wood |
| 45 | Providing and fixing 35 mm panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, including panelling and fitting like tower bolt, handles etc and carving designing on the door all job complete, all complete as per direction of Engineer-in-charge:First class Kail wood |
| 46 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and paint all complete.Welded |
| 47 | Providing 0.50mm thick colour coated Hi-rib G.S. profile sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including hips, ridges , valleys all complete. Red Colour |
| 48 | Providing and fixing of Ornamental Second class Kashmiri local Deodar wooded eaves boarding 300x30 mm (nominal size) with required carving as per the approved/available pattern and design (including cost of nails, cost of PU polish with sealer over prepared base) to be approved by Engineer-in-charge. |
| 49 | Providing and fixing of KHATAM BANDI ceiling of first class Kashmiri Local budloo wood including the cost of frame work , Heritage pattern and design to be approved by Engineer-in-charge. (Pahal Garden) all complete. |
| 50 | French spirit polishing, Two or more coats on new works including a coat of wood fille all complete. |
| 51 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer and paint, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes all complete. |
| 52 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) all complete. |
| 53 | Stone work (machine cut edges) for wall lining/cornice/moulding etc. (veneer work) upto 10 m height, backing filled with a grout of average 12 mm thick cement mortar 1:3 ( 1cement: 3 coarse sand) including pointing in white cement mortar 1:2 ( 1 White cement: 2 stone dust) with an admixture of pigment matching the stone shade and curing complete.White sand stone - Exposed face machine cut and table rubbed with rough backing. (20-30mm thick) all complete. |
| 54 | Stone/tile adhesive for fixing of tiles and stone cladding all complete. |
| 55 | Carriage of Material:Sand for an avg. lead of 15 Kms |
| 56 | Stone Agg. for an avg. lead of 15 Kms |
| 57 | Bricks for an avg. lead of 50 Kms |
| 58 | Compound Wall and Path |
| 59 | Dismantling steel work in single sections and CGI sheets of compound wall including dismembering and stacking within 50 meters lead. |
| 60 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 61 | Providing and laying in position reinforced cement concrete 1:1.5:3 (1 Cement: 1.5 coarse sand: 3 graded Stone aggregate 20mm nominal size) excluding cost of centering, shuttering, finishing and reinforcement. All work upto plinth level all complete. |
| 62 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more all complete. |
| 63 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level all complete. |
| 64 | Providing and fixing scaffolding system of bamboo sticks on the exterior side of building/ structure, upto 25 mtrs height above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, and maintaining it in a serviceable condition of execution of work of cleaning and/ or pointing and/or applying chemical and removing it their after the scaffolding system shall be stiffened with bracings, runners connecting with the building etc. where ever required. if feasible, for inspection of work at required location with essential safety features for the work men etc, complete as per directions and approval of Engineer-in-charge. |
| 65 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) all complete. |
| 66 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 67 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) all complete. |
| 68 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) all complete. |
| 69 | Providing and laying chisel dressed Devri Stone (Ashler/ Green/ Grey)/Cornice/moulding local stone of required size with 50 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing One face dressed Rough chisel dressed incl. necessary plaster incl. all carriages etc complete |
| 70 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position andapplying a priming coat of approved steel primer and paint, including welding and bolted with special shaped washers etc. complete Hot finished welded type tubes all complete. |
| 71 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm with some drawings of 3D all complete. |
| 72 | Excavating, supplying and filling of local earth (including royalty and cost of earth) by mechanical transport upto a lead of 10 kms also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc incl. 11 Km avg. lead Finished work to be measured all complete. |
| 73 | Providing and fixing concertina coil over the fencing including all necessary items and fixtures allowed till the rounds may be mentioned in one RM all complete. |
| 74 | Information boards of required size regarding temple name or any other information all complete. |
| 75 | Washrooms |
| 76 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 77 | 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 fine sand) all complete. |
| 78 | Providing and fixing Ist quality ceramic glazed wall tiles of approved make, in all colours, shades(of 7-8 mm thick of different sizes) as approved by Engineer- in-Charge, in walls, skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade incl. all carriages etc complete. |
| 79 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown all complete. |
| 80 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 81 | P/F of following PVC pipes/ Fittings of approved brand ( Prince Type- B ) including trenching and refilling all fittings/fixtures etc all complete. |
| 82 | 100 mm dia Pipe |
| 83 | 100 mm plain bend |
| 84 | 100mm Door tee |
| 85 | 100mm Collar |
| 86 | 100mm Floor Trap |
| 87 | 45' 100 mm bend |
| 88 | P-Trap 100 mm |
| 89 | 100 mm Plane Tee |
| 90 | 100-75 mm Reducer |
| 91 | 75 mm dia Pipe |
| 92 | 75 mm plain bend |
| 93 | 75 mm Door bend |
| 94 | 75 mm Plain/Door Tee |
| 95 | 75 mm Collar |
| 96 | P/F of following PPR pipes/ Fittings of approved brand Prince, Reliance, Vectus or equivalent ( heavy duty) including trenching and refilling all complete. |
| 97 | 16 mm Pipe Nominal dia |
| 98 | 32 mm dia pipe Nominal Dia |
| 99 | 32 mm stop cock |
| 100 | 15 mm stop cock |
| 101 | 15 mm Tee |
| 102 | 15 mm Elbow |
| 103 | 15 mm Socket |
| 104 | 15 mm male adopter |
| 105 | 15 mm female adopter |
| 106 | 15 mm tanky nipple and ball value |
| 107 | 32 mm male adopter |
| 108 | 32 mm female adopter |
| 109 | 32 mm Tee |
| 110 | 32 mm elbow |
| 111 | 32 mm Socket |
| 112 | P/F of following C.P fittings of approved brand and make (Parko/Hindware/Jaquar ) or equavallent including all complete. |
| 113 | Bib Cock |
| 114 | Angle Valve |
| 115 | C.P Gattings |
| 116 | Towel Ring 200mm dia |
| 117 | PVC Connection 450mm long |
| 118 | Looking Mirror 1'-6\\"x2'-0\\" with frame |
| 119 | Glass Shelf |
| 120 | Towel Rod 600mm long |
| 121 | Soap Case stainless steel |
| 122 | Wall Mixer of approved make |
| 123 | Basin Mixer of approved make |
| 124 | PVC Waste Pipe 32mm dia |
| 125 | Wash Basin with Padestal |
| 126 | Providing and fixing 50 liter capacity water heater Gyser of approved brand of Venus/ Recold/ Jaquar/ Hindware / cera or equivalent brand including its fixing at desired position complete in all respects as per directions of Incharge Engineer.. |
| 127 | P/F of Stainless Steel W.C ( Indian Type/European type) including P or S Trap , PVC Flushing Cistern and Stainless steel bend of approved brand like Hindware, Cera, Hindusten or equavallent all complete. |
| 128 | Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete popular wood |
| 129 | Providing corrugated G. S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 incl. ridges/hips/valleys( Red Colour). |
| 130 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank all fittings/fixtures etc complete. |
| 131 | providing manholes in cement concrete along with manhole cover of required sizes all job complete |
| 132 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan,including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 133 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) all complete. |
| 134 | Dry random rubble masonry with hard stone in foundation and plinth:With bond stone all complete. |
| 135 | Providing/supplying and filling of nallah boulders for back filling incl. all leads, lifts, carriages etc complete. |
| 136 | Carraige of material:- Sand/Stone agg. For an avg. lead of 15 Kms. |
| 137 | Stones for av avg. lead of 10 Kms |
| 138 | Electric Part (Pedestrian Walkway) |
| 139 | Providing and Laying RCC Foundation for Cast iron/MS composite ornamental Bollard 900mm (as per Approved sample/Drawing enclosed) as per drawing attached with Following Procedure & as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR .(Foundation work to be laid as per drawing)A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surfacecomplete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with MT bars Including straightening, cutting, bending, placing inposition and binding/welding together with bolts & Bars all complete.E) Centring and shuttering including strutting, propping etc. and removal of form work for Footing andF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEMG) Providing and Laying Reinforce cement Concrete of M-25 grade In Footing and Pedestal includingCuring the foundation for 7 days. |
| 140 | Supply/Fixing/Testing and Commissioning of Cast iron/MS composite ornamental Bollard 900mm (as per Approved sample/Drawing enclosed) having provision at bottom for built in gear box fitted with PVC 4 way connector of suitable amp. The bollard shall be powder coated painted to be approved color from compitent authority,confirming as per enclosed drawing /image of Dwarka/Karara Mujasame/Equivalent Make & Shall be approved by Department before Supplying. |
| 141 | Wiring in 1.5 Sq. mm 3-Core flexible, PVC insulated, round sheathed and annealed bare multi stranded copper conductor withstand voltage up to 1.1 KV of Polycab/Havells/RR-Kabel/Salzer/Finolex/Paraflex/Equivalent Make for service connection wires from bottom to top of the pole. (Complete in all respects). |
| 142 | Supply/Fixing/Testing and Commissioning of 6 Amp to 10 Amp Rating ,240v,*C* Curve 10K,SP Miniature Circuit Breaker suitable for inductive load and to be fitted in existing poles Complete with connections.(L&T/Siemens/ Legrand/ABB /Havells/BCH/Equivalent Make) |
| 143 | Supply/Fixing of 63 Amp of adquate size 4-Way in and 4-Way out Terminal Block/Connector Bottle/Pin type depending upon site conditions of standard make. |
| 144 | Supply/Fixing and Crimping of 16/25/35/50 Sq. mm aluminium lugs,cable thimbles at termination of the cables/ends including providing of insulation tapes. |
| 145 | Supply/Laying/Testing and Commissioning of following Al armored XLPE Insulated,PVC cable Havells/Polycab/RR-Kabel/KEI/Paramount/Equivalent Make. Including Supply/Laying of HDPE Pipe of required size, ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. |
| 146 | 4-Core 10 mm sq. |
| 147 | 4-Core 16 mm sq. |
| 148 | Design,Supply, Installation, Testing and Commissioning of CPRI Approved Main LT Control Double Door panel Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel. The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Multifunctional meter, R/Y/B Phase-indicators etc & angle iron stand painted in black colour of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects with following:-Incoming: 63 Amp-4 pole,25k-36kA MCCB with extended terminals Adjustable Thermal & Fixed Magnetic LK/ABB/Legrand/Simens Make =01 No & 100 Amp Suitable Al. Bus bar=01 SetOutgoing: 1) 32 Amp 4 pole TPN MCB of ABB/LK/Legrand/Schneider/Equivalent make as approved. =02 No.2) 163 Amp 4-Pole,415V Contactor = 01No. of ABB/LK/Legrand/Schneider/Equivalent make as approved. 3) Digital Astronimical Timer of GIC Make Specified as Below:* LCD Display with Green backlight* Precise time programming for Astro / Daily /Weekly / Pulse / Cyclic switching* Latitude / Longitude Database for 45 Countries and 280 cities* Settable Latitude / Longitude precise to the minute with time zone* Sunrise/Sunset or Twilight rise/set trigger modes * Ease of Day selection in Weekly programming* 50 ON/OFF programs, 10 Holiday Programs * Settable DST feature & Password protection* 16A Single and Dual relay outputs * Two Separate Relay outputs with independent Programming* 12/24 Hour Display Format * 6 Years Battery reserve * Simple Reset & Manual Override* Service/Load hours measurementPanel shall have provision for MCB’S/entry of cables from the bottom as required. |
| 149 | Main Power Supply |
| 150 | Supply/Laying/Testing and Commissioning of 3.5 Core 50 mm sq. Al armored XLPE Insulated,PVC cable Havells/RR-Kabel/KEI/Paramount/Equivalent Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01.5 Feet below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. The job further includes cost of Road cut and refilling of same with cement concrete where required.(From AVR Panel to Located Point) |
| 151 | Providing of Earthing Complete by GI Pipe 40mm 3 mtr long through GI Strip 25x3mm for Panels/Poles |
| 152 | CPRI Approved Main LT Control Double Door panel Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel with angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter . The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, R/Y/B Phase-indicators etc with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with following:-(1) Normal Incoming:100 Amp TPN MCCB 36kA with extended terminals Adjustable Thermal & Fixed Magnetic with ROH of Legrand/Siemens/ABB//LK make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set, Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set(2) Generator Incomer:63/100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set(3) Bypass Switch:3-Phase, Four Pole 63-100 Amp,415V Ac,50Hz with ROH Bypass Switch Havells/Seimens/LK/ABB Make for bypassing 15 KVA AVR.(4) Outgoing:(1) 200 Amp TPN Bus bar Al Strips = 1(2) 63 Amps TPN MCB (16 KA) of Legrand / Siemens/ ABB /Schinder /LK make = 02 No.(3) 63 Amps TPN MCCB (25-36 KA) of Legrand / Siemens/ ABB /Schinder /LK make = 02 No.The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing. |
| 153 | Internal Electrification for Temple |
| 154 | Wiring for Light point/Exhaust/Wall Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Anchor/Salzer/Havells/Paraflex Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 155 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 156 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Anchor/Salzer/Havells/Paraflex Make) |
| 157 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output) |
| 158 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make) |
| 159 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 160 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer /Havells/Paraflex Make) & shall be approved before execution of work. |
| 161 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 162 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 163 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH/Equivalent Make) |
| 164 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH/Equivalent Make) |
| 165 | 25-32Amp. |
| 166 | 40Amp. |
| 167 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make) |
| 168 | 8 way , Double door |
| 169 | Supply/Installation/Testing and Commissioning of IP-65/68 Homogenous LED Strip (Warm Type) Warm light with following Specifications: Input Wattage: 08-10W / Mtr,Input Voltage: 220 - 240VAC,Input Frequency: 50 Hz, Input Current (Max): 50mA, Power Factor:. > 0.95,Surge Protection:2.5KV, High Voltage Protection:300V,HI-POT:1.5KV,IP Rating:IP 65/68,Working Temperature:-10°C to 50°C, LED:Bridgelux,Lumen Maintenance:70% After 50000 BH,Rated CCT: 3000K, 4000K, 6500K,Rated CRI:> 80,System Efficacy:100lm/W,Housing:Silicon Pipe covers the LED Strip Light of Philips/Wioro/Jaguar/Surya/Equivalent Make & Shall be approved not less than by SDO. |
| 170 | Supply/Fixing/Testing and Commissioning of of Adoptor (CV DRIVER LED STRINGS 12 V 2 A IP44-66) of Philips/Wioro/Jaguar/Surya/Equivalent Make & Shall be approved not less than by SDO. |
| 171 | Supply and fixing of 18 Watt LED Powder coated die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 105 < 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2520 lumens with minimum system efficacy of 140 lumen/watt .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Wipro/Halonix/Surya/Equivalent make. |
| 172 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient/Halonix/Equivalent Make. |
| 173 | Supply/Installation/Testing and Commissioning of Wall Fan 400-900mm Sweep of USHA/Halonix/Polycab/Orient /Anchor/Equivalent Make.(5-Star) |
| 174 | Supply/Installation/Testing/Commissioning of 02-03KVA/24V Pure Sinewave Solar Inverter With ISOT Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 02 No. of 200Ah,12V Tubular battery (with 36 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Havells/Luminious/EXIDE/AMRON/Microtex Make. |
| 175 | Highmast Lighting |
| 176 | \\"Supply and Erection of 08/09 Mtr Galvanized Iron pole with galvanizing done in single dippine. (Average coating. thickness Minimum 65 Microns) continuously tapered poles having Octagonal / circular erose sectione designed to withstand the maximum wind speed as per Is 875, The pole shaft shall he made from shear steel (47 Steel Conforming to grade 536510) and Confirming to BS&N 1002, and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with tha rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing.Technical Specification:- 1) No. Of Section 1 NO. 2) No of sides 8 NOS. 3) Base plate size 200-225 X 200-225 MM 4) Base plate thickness 12 MM. 5) Base plate hole PCD 200-225 MM. 6) No of holes 4 NOS. 7) Hole dia 24 MM / SLOTTED 8) Size of door opening 250 MM. 9) Pole section length 6000 MM. 10) Pole section Theckness 3 MM. 11) Bottom Dia ( Outer ) 130 MM. 12) Top Dia ( Outer ) 70 MM. 13) Foundation Bolt Length 500-550 MM. 14) Foundation Bolt Dia 20 MM. 15) Wind Speed 180 Km / Hr. 16) Dimension Tolerance As Per BSEN 40. 17) Material Tolerance As Per IS 1852 - 1985. 18) Shaft Material Type As Per BSEN 10025 S 355 Or Equivalent. 19) Base Plate Type As Per IS 2062. 20) Foundation Bolt Type As Per IS 1367 Gr. 6.8. 21) Material Protection Hot Dip Galvanized. 22) Zinc Coating Thickness 65 Microns. 23) Galvanizing Type AS PER ISO 1461 : 1999. 24) Finishing Type As Per IS 11759 - 198. The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 Sq.mm stud type connector (4 nos) inside the pole at door opening for cable connection (Utkarsh/Valmont/BPP/Surya/Equivalent Make. Also includes Supply/Fixing of 8 SWG G.I wire run over the cable length properly earthed with main earthing pit/grid (Standard make) |
| 177 | Design/Supply/Fixing of one way Convex Shape Type G.I Bracket & shall hold 04 No. of flood Lights of 200Watt Each & to be approved before Designing & Supplying, as per site requirement on approval of site Incharge. |
| 178 | Providing and Laying RCC Foundation for 08/09 Mtr Octagonal Poles)(2'x2'x4') as per drawing attached Following Procedure & Al as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with MT bars Including straightening, cutting, bending, placing inposition and binding all complete.E) Centring and shuttering including strutting, propping etc. and removal of form work for Footing andF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEMG) Providing and Laying Reinforce cement Concrete of M-25 grade In Footing and Pedestal includingCuring the foundation for 7 days. |
| 179 | Supply/Installation/Testing and Commissioning of IK08 IP-66 protected high power 180-200Watt.LED flood light system with single piece Pressure die cast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate (System lumen efficacy ≥125 and <135 lm/Watt). LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @›=300 V AC and Auto resetting Safety Power Factor >0.95, THD(1) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10K external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. connection wires. Approved Make: Wipro/Philips/Trilux/Jaquar/Crompton/Surya/Equivalent Make. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail