| 1 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:For thickness of tiles 25mm to 40mm. |
| 3 | Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead: |
| 4 | Dismantling wooden boards in lining of walls and partition excluding supporting members but including stacking within 50 meter lead:Thickness above 10mm up to 25mm |
| 5 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: |
| 6 | Replacement of stone Chajja with sriwan in damaged portion as per existing thickness and width in CM 1 : 3 with removal of old damaged pieces of chajja including top plaster of chajja and bottom pointing in CM 1 : 3 with scoffolding upto Ground floor level as per direction of Engineer in charge |
| 7 | Add Extra for each additional floor |
| 8 | Providing and fixing double scaffolding system on the exterior side, upto five story made with 4\\" wooden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. The scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of EI.The lavation area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding.Note : This item to be used for maintence work judicially |
| 9 | Cement plaster 1:3 under old stone slabs with admixture (gur,nails,binding wire to mesh and scraping scales & dressing joints of slabs complete.Proofing upto 25 mm thickness. |
| 10 | Face lifting (Doba Wash) with washing of stones by (1:20) acid & water solution, rubbing by brush, washing by clear water, pointing of damaged grooves & doba washing with good quality lime water and painting of doors, windows, ventilators upto all height & lead including all scaffolding and T&P etc. complete as per instructions and direction of Engineer-in-charge. |
| 11 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :25 mm thick. |
| 12 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with (Bevelled Tegular) EDGE TILES WITH 15 mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99% NRC 0.5, Light Reflectance _>85%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600 x 600 x 16 mm, suitable for Green Building application, with Recycled content of 32 %. The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/Sqm minimum pull out strength of 100 kgs. Silhouette, |
| 13 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with (Bevelled Tegular) EDGE TILES WITH 15 mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99% NRC 0.5, Light Reflectance _>85%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600 x 600 x 16 mm, suitable for Green Building application, with Recycled content of 32 %. The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/Sqm minimum pull out strength of 100 kgs. Silhouette, |
| 14 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with (Bevelled Tegular) EDGE TILES WITH 15 mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99% NRC 0.5, Light Reflectance _>85%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600 x 600 x 16 mm, suitable for Green Building application, with Recycled content of 32 %. The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/Sqm minimum pull out strength of 100 kgs. Silhouette, |
| 15 | Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : |
| 16 | Providing and fixing external grade board solid core Double leaf flush door shutters ISI 2202-67 marked using Phenol formal, dehydreresin in glue both sides with approved steel fittings complete as per Annexure ‘A’ Decorative Teak veener one side 35 mm thick shutter |
| 17 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 18 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 19 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 20 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 21 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) |
| 22 | Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 23 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 24 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 25 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 26 | Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Deep groove pointing |
| 27 | Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand): Flush/ Ruled pointing |
| 28 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 29 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South (Red)Above 3601 Cm2 Slabs |
| 30 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 31 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work Please Enable Macros to View BoQ information |