Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Note: 1. The rates for the civil, sanitary Items are b PWD integrated BSR 2022 & Elect. Items are based o PWD BSR 2022 Elect. (All Raj.).2. In case of any typographical error, the relevant code for specification & BSR for rates shall be final.3. The contents of RPWA 100 shall form the essential & integral part of this G-Schedule. |
| 2 | Part-A Civil Works |
| 3 | Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : Allkinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 5 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50Mtr.: All kinds of soil |
| 6 | Pipes cables etc. not exceeding 80mm dia |
| 7 | Pipes cables, etc. exceeding 80mm dia but notexceeding 300mm dia. |
| 8 | Pipes, cables etc. exceeding 300mm dia but notexceeding 600mm dia. |
| 9 | Add extra for excavating trench for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 Mtr. but notexceeding 3 Mtr. |
| 10 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering includinglead up to 50 meter and with all lift. |
| 11 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift upto 1.5 Mtr. : All kinds of soil |
| 12 | Anti-termite treatment of existing floor and wall using Imidacloprid 30.5% EC non repellent, odorless, low dose, environimentally safe Termiticide with rapid action non corrosive stain free, by injecting the emulsion as per specification and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area. The pesticide emulsion of imidacloprid 30.5% EC mixed with water in the ration of 1:474 will be pumped by a motorized spray pump specified manner. The net floor and wall area treatedwill be measured for payment. |
| 13 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering andshuttering - All work up to plinth level. |
| 14 | M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 15 | M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 16 | Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete asper specification 50mm thick. |
| 17 | Providing & fixing precast cement concrete coping1 : 2 : 4 mix 50mm thick complete as per specification : |
| 18 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix |
| 19 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix |
| 20 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 21 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strapbeam, raft , bases of columns etc. |
| 22 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floorfive level for : |
| 23 | Walls (any thickness) including attached pilasters, buttresses plinth and stringcourse. |
| 24 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam,plinth beam etc. |
| 25 | Columns, pillars, posts and struts etc. |
| 26 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treatedbars (Conforming of relevent IS code) |
| 27 | Rebarring work in old R.C.C structures including making bore hole to adjust required bar diameter and filling a good quality filler to provide a tensil strength as per requirement and fix the Bar to the sactionincluding cost of bars. |
| 28 | 10 mm bar |
| 29 | 12 mm bar |
| 30 | 16 mm bar |
| 31 | 20mm bar |
| 32 | 25mm bar |
| 33 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1 : 6 (1cement : 6 coarse sand) |
| 34 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 35 | Add extra providing and placing in position 2 Nos.,6mm Ø M.S. bar at every third course of half brick masonry . |
| 36 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 37 | Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade. |
| 38 | Providing dab stone over Chajjas duly fixed in cementsand mortar 1:6 complete : |
| 39 | 80mm thick. |
| 40 | 50mm thick. |
| 41 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 withmachine cut edges : |
| 42 | Sand or other approved stone 25mm thick. |
| 43 | Sand or other approved stone 50mm thick. |
| 44 | Kota stone minimum 30mm thick. |
| 45 | Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar1:4 : |
| 46 | Upto 15 cm. thick. |
| 47 | Above 15 cm. thick. |
| 48 | Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishingcomplete. |
| 49 | Makrana 'Adanga'. Above 3601 Cm2 Slabs |
| 50 | Rajnagar 1st quality/Ageria with light spots. Above3601 Cm2 Slabs |
| 51 | Keseriaji/ Abu Ambaji (Green Marble) Above 3601Cm2 Slabs |
| 52 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab includinggrinding, rubbing and polishing complete. |
| 53 | Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour)Above 3601 Cm2 Slabs |
| 54 | South (Red) Above 3601 Cm2 Slabs |
| 55 | South Zed Black Above 3601 Cm2 Slabs |
| 56 | Rajasthan Black Above 3601 Cm2 Slabs |
| 57 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved byEngineer-in-Charge. |
| 58 | Marble work |
| 59 | Full Edge moulding |
| 60 | Half Edge moulding |
| 61 | Granite/Kota Stone Work |
| 62 | Full Edge moulding |
| 63 | Half Edge moulding |
| 64 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesiveincluding cleaning etc. complete |
| 65 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing andpolishing of cut edges etc. complete |
| 66 | Extra for Mirror polishing on marble work where everrequired to give high gloss finish complete. |
| 67 | Extra in marble/other flooring work for upto 50 mm wide strip of Green/White/ Jaisalmer stone in flooringwork as per direction of Engineer in Charge |
| 68 | Providing and fixing cramps of required size & shape in RCC/ CC backing with cement mortar 1:2 ( 1 cement :2 coarse sand) including drilling necessaryhole in stones and embedding the cramp in the hole . |
| 69 | Gun Metal cramp |
| 70 | Stainless steel cramps |
| 71 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS:15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls andpillar). |
| 72 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS: 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed1:4). |
| 73 | Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finishedtiles. |
| 74 | Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 75 | Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finishedtiles. |
| 76 | Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 77 | Providing and fixing 75 mm wide Decorative Border in different shades and in all coloures in glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shadecomplete. |
| 78 | P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etccomplete size 600 mm X 600 mm |
| 79 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick- set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, inaverage 3mm thickness instead of cement mortar. |
| 80 | P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc completeSize 600mm x 600mm |
| 81 | Providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter V type including machine polishing to groove to give high gloss finish etc. complete as per designapproved by engineer in charge |
| 82 | P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints withwhite cement and matching pigment etc complete. |
| 83 | size 600 mm X 600 mm |
| 84 | size 600 mm X 1200mm |
| 85 | P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints withwhite cement and matching pigment etc complete. |
| 86 | size 600 mm X 600mm |
| 87 | size 800 mm X 800mm |
| 88 | size 1000 mm X 1000mm |
| 89 | size 600 mm X 1200mm |
| 90 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying apriming coat of approved steel primer all complete. |
| 91 | Add Extra if I/rail section is used |
| 92 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primerall complete: |
| 93 | Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paidextra) with priming coat of red oxide. |
| 94 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication withpriming coat of red oxide |
| 95 | Extra if square,rectangular hollow tubelar sectionsare used or grill made by flats only |
| 96 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (Tobe measured and paid as per outer dimension). |
| 97 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured forpayment). |
| 98 | Providing & fixing ball bearing for rolling shutters |
| 99 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coatsof anit-corrosive red oxide primer paint |
| 100 | Add extra for double leaf shutters. |
| 101 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required Partly fixed and partly openable [ fixed area not to exceed33%] |
| 102 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at notexceeding 150mm distance. |
| 103 | Providing and fixing Square bars or other flat weldedto window, ventilatiors etc. |
| 104 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in allrespect as per direction of Engineer-in –charge |
| 105 | Window openable. |
| 106 | Window fixed. |
| 107 | Extra for additional shutter in pipe section windowswith wire gauge 14 mesh x 24 gauge |
| 108 | Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size 50mm x50mm x 3.15mm |
| 109 | Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost ofMS angle, CC block shall be paid extra) |
| 110 | Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding framework) of size. |
| 111 | Welded mesh 25 mmx 25 mm x 2.1 mm |
| 112 | Expended metal size 20-25 mm size 18SWG |
| 113 | Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer InCharge |
| 114 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, with ceiling pointing in cement sand mortar 1 : 3 complete as per specification andinstruction of Engineer In Charge |
| 115 | Add extra for subsequent story |
| 116 | Grading roof for water proofing treatment with waterproffing compound |
| 117 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) |
| 118 | Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 119 | Cement mortar 1:4 (1cement : 4 coarse sand) |
| 120 | Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machine complete on20 mm thick bed of cement sand mortar 1 : 4. |
| 121 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations.(a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS. 2645 over the RCC slab including cleaning the surface before treatment.(b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4 (1 cement :4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs. |
| 122 | (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300xmm square(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.With average thickness of 120mm and minimumthickness at khurra as 65 mm. |
| 123 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standarddesign : |
| 124 | Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out letcomplete. |
| 125 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 126 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented,textured or smooth as specified. |
| 127 | 3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.) |
| 128 | 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) |
| 129 | Dry brick on edge flooring in required pattern with bricks of class designation 75 on a bed of 12 mm mud mortar including filling joints with River sandcomplete. |
| 130 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excludingthe cost of nosing of steps etc. complete. |
| 131 | 40mm thick with 20mm thick nominal sizeaggregate. |
| 132 | 75mm thick with 20mm thick nominal sizeaggregate. |
| 133 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4coarse sand) Dark shade using ordinary cement. |
| 134 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarsesand) |
| 135 | For area of each slab from 901 to 2000 Sq.Cm : |
| 136 | For area of each slab from 2001 to 5000 Sq.Cm |
| 137 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, includingrubbing and polishing complete |
| 138 | For area of each slab upto 2001 Sqcm |
| 139 | For area of each slab from 2001 to 5000 Sqcm |
| 140 | Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with jointthickness up to 15 mm complete in all respects : |
| 141 | Random rubble dry stone Kharanja under floor. |
| 142 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (PrecastC.C. kerb stone shall be approved by Engineerin-charge). |
| 143 | Providing and laying M30 grade controlled cement concrete pavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with 20/25 mm stone aggregate (crusher broken) including anti-skid textured finish to required camber/ super elevation and grade including curing etc. as per specification with cement concrete M-30 grade including cost of Steel frame work for sides of C.C. pavement consisting of M. S. channels flats and angles with required steel pegs ( some of them may left embedded in concrete/ including providing framework) |
| 144 | Extra for vacuum processed concrete including costof equipments labour etc. |
| 145 | Cutting of construction joint/ longitudinal joint 4 to 6mm. wide using mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealing compound in groove including costof sealing compound. |
| 146 | 25 mm depth |
| 147 | 50 mm depth |
| 148 | 75 mm depth |
| 149 | 100 mm depth |
| 150 | 25mm thick wooden planking, tongued and grooved in flooring including fixing with iron screws complete (Lower frame to be paid extra) with :First class Teakwood. |
| 151 | Providing and Fixing Cushion Vinyl/Fully flexible Vinyl Flooring confirming to I.S.-3462 Flooring of approved make with fibre base using rubber base adhesivesincluding rolling with light wooden roller complete : |
| 152 | 1.0 mm thick. |
| 153 | 1.5 mm thick. |
| 154 | 2.0 mm thick. |
| 155 | Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 ofIS 15658:2006 |
| 156 | Category A Denated units to key into each other onfour faces zigzag shape as per IRC SP 63:2004 |
| 157 | Category ‘B’ Denated only two side like I,Z,T shapeetc. as per IRC SP 63:2004 |
| 158 | Category ‘C’not denated on any it’s faces like Hexagon, Rectangular, square shape as per IRC SP63:2004 |
| 159 | Providing & Laying Tactile tile (for vision impaired persons is standard of size 300x300x20mm and confirming to IS 1231 of 1980 (Re affirmed in 2006) in all colours & sheds further product should confirm ASTM 303 for shad resistance and DIN51099 for colour fastness etc. laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 course sand) in all shapes & patterns including grouting the joint which white cement mixer) will matching pigments etc complete is per direction of Engineer-in-charges.Grade M 30 |
| 160 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. completefine finish : |
| 161 | 25 mm thick. |
| 162 | 20mm thick . |
| 163 | 12mm thick . |
| 164 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete finefinish : |
| 165 | 25 mm thick |
| 166 | 20mm thick. |
| 167 | 12mm thick. |
| 168 | 6 mm thick cement plaster to ceiling of mix 1:3(1cement : 3-fine sand) |
| 169 | Making grooves as per design in plaster 10mm to20mm wide. |
| 170 | Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as perapproved design |
| 171 | 12 mm thick plain cement mortar bands in cementmortar 1:4 (1 cement : 4 fine sand) Raised Band |
| 172 | Providing & Laying POP moulding & beading in ceiling including nailing & scafollding etc. complete ofsize : |
| 173 | 25mm x 12mm |
| 174 | 25mm x 25 mm |
| 175 | Providing & Laying POP Cornice of required design & pattern in ceiling including nailing &scafollding etc. complete with fine finishing of size: |
| 176 | 50mm x 50mm |
| 177 | 65mm x 65mm |
| 178 | 75mm x 75mm |
| 179 | Pointing on stone masonry in cement sandmortar 1:3 (1 cement : 3 sand) : |
| 180 | Flush / Ruled/ Struck or weathered pointing. |
| 181 | Raised and cut pointing. |
| 182 | Deep groove pointing |
| 183 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1cement : 4 coarse sand) |
| 184 | Repair to stone masonary in cement sand mortar 1:6with old and new stone. |
| 185 | Repair to brick masonary in cement sand mortar 1:6with new brick. |
| 186 | Cement plaster 1:3 under old stone slabs with admixture (gur,nails,binding wire to mesh andscraping scales & dressing joints of slabs complete. |
| 187 | Proofing upto 25 mm thickness. |
| 188 | Proofing above 25 mm thickness& upto 60 mmthickness |
| 189 | Patch repair to cement concrete floor including digging out old floor in regular shape and removal ofrubbish curing etc. complete in all respects. |
| 190 | Making holes in stone masonry wall upto 450 mm x450 mm size and making good in CM 1:6. |
| 191 | Grinding of existing floor with |
| 192 | 60, 80, 120 and 360 No. Carborundum stoneincluding cost of wax polishing complete : |
| 193 | 120 and 360 No. Carborundum stone includingcost of wax polishing complete : |
| 194 | Add extra for mirror polishing on existing marble work/ Kota stone flooring work where ever required to givehigh gloss finish complete. |
| 195 | Providing and fixing double scaffolding system on the exterior side, upto five story made with 4\\" wooden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. The scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of EI.The lavation area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding.Note : This item to be used for maintence workjudicially |
| 196 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of weldingmeachine and TP etc complete |
| 197 | L/C for fixing of GI/AC sheet include. Cutting jhiri and repair , cutting of sheet , fixing of sheet with J or Lhook and bitumen washer as per direction of EI |
| 198 | Repair of rolling shutter with replacement of shutter spring incl. removal of old spring in the existing rollingshutter incld. Cost of new spring |
| 199 | Repair of rolling shutter with using any material such as bend repair , tightening of spring,bolt and screwetc complete |
| 200 | Refebrication work with existing steel work including cutting, welding & refebrication as per requirement with fixing at site complete as per direction ofEngineer In charge |
| 201 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 infollowing steps :- |
| 202 | Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary andgetting dried. |
| 203 | Applying Epoxy primer on the exposed steel bars. |
| 204 | Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steelbars with brush. |
| 205 | Speading dry cement mortar 1 : 2 mix over epoxytreated wet surface and allow it to dry for one day. |
| 206 | Plastering the surface with cement sand mortar 1 : 3upto depth of 30mm complete. |
| 207 | Cure the plastered surface for 15 days, All workincluding scaffolding etc. complete in all respect. |
| 208 | Replacement of stone Chajja with sriwan in damaged portion as per existing thickness and width in CM 1 : 3 with removal of old damaged pieces of chajja including top plaster of chajja and bottom pointing in CM 1 : 3 with scoffolding upto Ground floor level asper direction of Engineer in charge |
| 209 | Repair to damaged cement plaster of stone chajja with CM 1 : 3 of required thickness on top & bottom as per existing pattern and making patta etc complete up to three floor level as per direction of Engineer incharge including all necessary scoffolding etc |
| 210 | Making of hole in R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cuttingmachine complete as per direction of EI |
| 211 | From diameter 100mm to 150mm |
| 212 | Diameter above 150mm |
| 213 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 214 | 1: 3: 6 or richer mix. |
| 215 | 1: 4: 8 or leaner mix. |
| 216 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as perdirection of Engineer-in-charge. |
| 217 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C.or R.B. work) as per direction of Engineer-in-charge |
| 218 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge Incement mortar. |
| 219 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-chargeIn cement mortar. |
| 220 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meterslead: |
| 221 | Of area 3 square meter and below. |
| 222 | Of area exceeding 3 square meter. |
| 223 | Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50meters lead: |
| 224 | Of area 3 square meter and below. |
| 225 | Of area exceeding 3 square meter. |
| 226 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meterlead: |
| 227 | For thickness of tiles 10mm to 25mm. |
| 228 | For thickness of tiles 25mm to 40mm. |
| 229 | Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within50 meters lead. |
| 230 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meterlead of: |
| 231 | G.I. Sheet. |
| 232 | Asbestos Sheet. |
| 233 | Dismantling tar felt over roofing complete including stacking of serviceable material and disposal ofunserviceable material within 50-meter lead. |
| 234 | Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposalof unserviceable materials within 50 metres lead : |
| 235 | Upto 1.44 Sqm |
| 236 | Above 1.44 Sqm to 2.52 Sqm |
| 237 | Above 2.52 Sqm to 3.84 Sqm |
| 238 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposalof rubbish to the dumping ground within 50 meter lead. |
| 239 | Making of hole (width up to 150 mm) in R.C.C. slab/wall/beams by power driven drilling machinecomplete as per direction of EI |
| 240 | upto 150mm thick |
| 241 | above 150 mm thick |
| 242 | Supplying and applying bituminous solution primer onroofs or on wall surface at 0.24 litre per sqm. |
| 243 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick |
| 244 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick |
| 245 | Supplying and providing of two components poly sulphide sealant containing solid contents, confirming to standard specification and approved compatible primer, for priming vertical faces prior to application of poly sulphide sealant including all labour charges for sealing of expansion joints after drill mixing of two components sealing compound. Cleaning and preparation of expansion joint using wire brush sand papering with emery paper and filing with suitable mechanical means. The work includes racking and cleaning of joints, sticking, debonding tape on bottom of joint, applying primer on edges, using masking tape on edges, providing of sealant and removal of masking tape immediately after providing sealant injoint. |
| 246 | To vertical joint between RCC columns, bricks & stone masonry in size 40 mm width and 12 mm depth, including providing back up material(Thermocol foam) if required. |
| 247 | To joints in flooring, as per drawing with first layer of poly sulphide sealant in size 20 mm width and 10 mm depth over PE Foam and then providing polyethylene foam back up rod 25 mm dia size and finally providing another layer of poly sulphide sealant in size 20 mm width and 10 mm depth over P.E. back up rod as per application procedure and direction of Engineer-in-charge. |
| 248 | Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows andventilator frames of approved quarry : |
| 249 | Size 100x 75mm |
| 250 | Size 125 x 100mm |
| 251 | Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames ofapproved quarry: |
| 252 | Size 100 x 75mm. |
| 253 | Size 125 x 100mm |
| 254 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum upto 12mts with all scaffolding. |
| 255 | Suppy of Beldar |
| 256 | Carriage of Building Rubbish Stone metal (Grit and ballast etc.) including loading and unloading with leadof 20km. |
| 257 | Part-B Joinary Works |
| 258 | Diluting and injecting by hand operated pressure pumps chemical Emulsion timber ground treatment [TCGT] in ratio 1: 2 as per manufacturers specification for POST CONSTRUCTIONAL Anti-termite treatment (as per IS 6313) part - III 1971 as amended from time to time) (excluding the cost of chemical emulsion) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 |
| 259 | Providing and fixing fully panelled/partly panelled/ double leaf shutter frames for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on bothfaces complete 30 mm thick 30 mm thick |
| 260 | Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling forpanelled and glazed shutter 25 mm to 40 mm thick |
| 261 | Wood panel grade I Ghana wood grade I |
| 262 | IS 710- 1976 marked 12 mm thick commerical ply |
| 263 | IS 710- 1976 marked 12mm thick Teak ply BWR bothside |
| 264 | SS wire gauge 14 mesh x 24 gauge |
| 265 | 5 mm float glass |
| 266 | 6 mm thick glass |
| 267 | 10 mm thick glass |
| 268 | 12 mm thick glass |
| 269 | Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall bemeasured). |
| 270 | Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall bemeasured). |
| 271 | Add extra for etching work in glass work as per direction of engineer incharge (Area of opening for glass panes excluding portion inside rebate shall bemeasured) |
| 272 | 5 mm float glass |
| 273 | 6 mm thick glass |
| 274 | 12 mm thick glass |
| 275 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure'A' : |
| 276 | 30 mm thick .Commercial Veneer both side |
| 277 | 35 mm thick .Commercial Veneer both side |
| 278 | 35 mm thick .Decorative teak veneer both side |
| 279 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured)Over item no. 8.13. |
| 280 | Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter tobe measured). |
| 281 | Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification anddrawing using : |
| 282 | ISI 6 mm teak ply one side BWR |
| 283 | ISI 9 mm teak ply one side BWR |
| 284 | 12mm thick Acoustical Board |
| 285 | Providing and fixing 50 mm thick resin bounded glass wool 32 kg/cum density wrapped in julities cloth bag(box type) and held in position using chicken mesh |
| 286 | Providing and fixing Hassian cloth of approved colour and texture over soft wood frame glass wool & fibreglass tissue paper |
| 287 | Providing and fixing Nigeria / Ghana /Ivory Coast Teak wood grade-I mouldings and beadings in doorsand windows size :- |
| 288 | 50x12 mm |
| 289 | 50x20 mm |
| 290 | 25x12 mm |
| 291 | 25x20 mm |
| 292 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessarycomplete: |
| 293 | 12 mm |
| 294 | 20 mm |
| 295 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment withnecessary accessories and screws etc. complete. |
| 296 | Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of wood in scantling of section 50X25mm fixed with nails and GI wire to existing surface complete as per direction ofEI |
| 297 | Providing and Fixing Bamboo Zafari/Fencing consisting of superior quality 25mm dia Solid Bamboo placed vertically & fixed together with 3 Nos Horizontal running members of wood in scantling of section size 50x40mm and fixed with nut and bolt to existing surface/angle post as per direction given by Engineer-in-charge |
| 298 | Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50mm(base and height) |
| 299 | Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction ofEngineer-in-charge. |
| 300 | Providing and fixing Almirah lock (50 to 70 mm size )of approved make without pair of handles for door with necessary screws etc complete as per direction ofEngineer-in-charge. |
| 301 | Providing & Fixing of ward robe shutters made out of 19mm thick BWP block board ISI of superior quality make with following details Front side finishing with 1mm thick superior quality mica approved make and 0.8mm thick approved shade mica in the inner side. Covering with teak wood beading 25x12mm all the sides of shutter & 35x12mm on outer frame for making good the wall joint including heavy brass S.S. fittings (Handle 200mm 2 Nos., Tower Bolt 150mm 2 Nos., Brass Lock 1 Nos., Magnetic Catcher 2 Nos., Brass Hinges 75x40x2.5 mm 6 Nos., SS Hanger Rod 20mm dia) complete as per drawing and design approved byEngineer in Charge. |
| 302 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nailscomplete as per approved by engineer in charge. |
| 303 | 0.6mm thick mica |
| 304 | 0.8mm thick mica |
| 305 | Providing & Fixing decorative veneer of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer incharge. |
| 306 | 4.0mm thick veneer |
| 307 | 6.0mm thick veneer |
| 308 | Providing and fixing S.S. Rod 30mm dia (304 grade,16SWG) including brackets fixed with C.P. brass screws and rawl plugs, etc., wherever necessary complete two side central all fittings. |
| 309 | Providing & Fixing BWR ISI marked 19 mm board of approved make for making wardrobe/shelves and other furniture with fevicol & nails complete as perapproved by engineer in charge. |
| 310 | Providing & Fixing Commercial Ply as per IS 710 : 1976 BWR of approved make for making wardrobe/shelves and other furniture with fevicol & nails complete as per approved by engineer incharge. |
| 311 | 18 mm thick |
| 312 | 12 mm thick |
| 313 | 6 mm thick |
| 314 | Providing & Fixing telescopic channel of approved make for drawers with screws complete as perapproved by engineer in charge. |
| 315 | 300mm long |
| 316 | 400mm long |
| 317 | 450mm long. |
| 318 | 500mm long |
| 319 | 600mm long |
| 320 | Providing & Fixing drawer handle of approved make for drawers with screws complete as per approved byengineer in charge. |
| 321 | 100mm long |
| 322 | 150mm long |
| 323 | Providing & Fixing drawer lock of approved make for drawers with screws complete as per approved byengineer in charge. |
| 324 | Providing and fixing aluminum work for doors,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing andpaneling to be paid for separately). |
| 325 | For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS: 1868. (Minimum anodic coating of grade AC 15,Anodizing to be got done from approved Anodizer) |
| 326 | For fixed portion Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 327 | For fixed portion Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) |
| 328 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approvedAnodizer) |
| 329 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Powder coating aluminum ( minimum thickness of powder coating 50micron) |
| 330 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum ( minimum thickness of powdercoating 50 micron) |
| 331 | Extra for shutters of sliding aluminum windows |
| 332 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approvedAnodizer) |
| 333 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Powder coating aluminum ( minimum thickness of powder coating 50micron) |
| 334 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum ( minimum thickness of powdercoating 50 micron) |
| 335 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors,windows shutters and partition frames with C.P. brass/ stainless steel screws etc. complete as per architectural drawings and direction of engineer-in- charge. |
| 336 | Pre-laminated particle board with decorative lamination on one side and balancing laminationon other side. |
| 337 | Prelaminated particle board with decorative laminationon both sides. |
| 338 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- in-charge.(Cost of aluminium snap beading shall bepaid in basic item.) |
| 339 | With glass panes of 4.0 mm thickness ( weight notless than 10.0 kg/sqm) as per IS : 2835. |
| 340 | With float glass panes of 5.0 mm thickness ( weightnot less than 13.50 kg/sqm) |
| 341 | With float glass panes of 8 mm thickness |
| 342 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates withbrass pivot and single piece M.S. |
| 343 | With stainless steel cover plate |
| 344 | With brass cover plate |
| 345 | Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-chargecomplete. |
| 346 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors includingnecessary cutting and making good etc. complete. |
| 347 | Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per directionof Engineer-in-charge |
| 348 | Anodized (AC 15 ) aluminium |
| 349 | Powder coated minimum thickness 50 micronaluminium |
| 350 | Polyester powder coated minimum thickness 50micron aluminium . |
| 351 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in allrespect as per direction of engineer in charge. |
| 352 | Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be gotdone from approved Anodizer) |
| 353 | Powder coating aluminum ( minimum thickness ofpowder coating 50 micron) |
| 354 | Polyester Powder coating aluminum ( minimumthickness of powder coating 50 micron) |
| 355 | S&f fixed wire gauge of stainless steel of 14 mesh x24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift withscafolding. |
| 356 | Providing and fixing vertical Blinds, headrail shall be oriented aluminum alloy 50 mm wide x 18 mm high the thickness shall be 1.2 mm. Control unit shall be made of high grade polymer and shall be housed in side the headrail, which shall transfer motion from chain tilter to tilt rod. Chain tilter shall be made of plastic bead of diameter 4.5 mm through which 2 mm thick polyester code passes. Tilt rod shall be extruded aluminum having 3 key ways. Runner shall be moulded plastic and shall have to plastic wheels mounted on plastic axles to enable runner to slide unhindered in headrail. Luver shall be made of fabric100 mm colour fast and shall have protective scotchgard coating to resist stains and dust. Bottom mechanism consist bottom weight made of powder coated galvanized steel for maximum corrosion resistance. The bottom weight shall be attached withbottom. |
| 357 | Providing and fixing Horizontal blinds /Venation blind shall be cold rolled formed U shape 23 mm high x 25 mm wide with flanged edges. It shall be made of heavy gaze 0.56 mm galvanized steel, Slates shall be made of virgin Al. alloy (having 3.5 – 4.5% of Mg. Content of width 25 mm. The slat shall have dust guard paint coating, the chord lock shall be of thick tomized steel and shall be securely attach in the head rail. It shall provide locking arrangement of the cord. Tilt rod shall be made of galvanized steel it shall have a D shaped with an average cross section with diameter of 6 mm to achieve minimum torsionaldeflection. |
| 358 | Providing and fixing Drapery rod shall be made of 20 gauge cold rolled steel strip, which is electrical resistance welded. The section will be available 25.4 mm diameter the section shall be coated with acid resistance polymer finish shall made from ABS material in nearest matching colour of rod. The ring shall be made from ABS material in nearest matchingcolour to rod. Brackets made of galvanized steel. |
| 359 | Providing and fixing sun control film, thickness of film1 Mil Visible Light Transmittance 4-24% & Solar Energy Transmittance 42-51% & Total solar Energy rejection 37-43%of approved colour and shade , complete in all respect , at all level , as directed byengineer- in -charge. |
| 360 | Providing and fixing factory made of uPVC Extruded section having an overall dimension as below (tolerance+/-1mm) with wall thickness 2.0mm+/- 0.2mm,corners of the door frame to be mitred and welded of plastic ,galvanized brackets and stain less steel screws.The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19x19mm and 1mm+/-0.1mm wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge. |
| 361 | Extruded section profile size 48x40 mm |
| 362 | Extruded section profile size 42x50 mm |
| 363 | Providing and fixing to existing door frames 30mm thick factory made polyvinyl chloride (PVC) door shutter made of stiles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2mm +/- 0.2mm with inbuilt decorative moulding edging on one side. The stiles and rails mitred and joined and the corners by means of M.S.galvanized/plastic brackets of size 75x220 mm having wall thickness 1.0mmand stainless steel screws. The stiles of the shutter reinforced by inserting galvanized M.S.tube of size 25x20 mm and 1mm +/- 0.1mm wall thickness. The lock rail made up of „H‟ section, a uPVC hollow section of size 100x30 mm and 2mm +/- 0.2mm wall thickness fixed to the shutter stiles by means of plastic/galvanized M.S.tube „U‟ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 610mm,having overall thickness of 20mm and 1mm+/- 0.1mm wall thickness.The panels filled vertically and tie bar at two places byinserting horizontally 6mm galvanized M.S.rod and fastened with nuts and washers.complete as per manufacturer‟s specification and direction of Engineer- in-charge.(For W.C.and bathroom door shutter) |
| 364 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. |
| 365 | Providing and fixing to existing door frames. |
| 366 | 30mm thick factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes of19 gauge thickness and size of 19mm x 19mm for stiles and 15 mm x15mm , top & bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC „C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together withsolvent cement adhesive. An additional 5mm thick |
| 367 | 30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC „C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thickPVC strip of 20mm width is to be stuck on the interior |
| 368 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 50mmx48mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in allrespect as per direction of engineer in charge. |
| 369 | Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be gotdone from approved Anodizer) |
| 370 | Powder coating aluminum ( minimum thickness ofpowder coating 50 micron) |
| 371 | Polyester Powder coating aluminum ( minimumthickness of powder coating 50 micron) |
| 372 | Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi- chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather sealgaskets alongwith 6mm thick ISI make plain float |
| 373 | Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi- chamber construction, Laminated (colour) finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of laminated ( colour) having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weatherseal gaskets alongwith 6mm thick ISI make plain float |
| 374 | Providing and fixing of UPVC casement openable windows (outward / inward): Outer Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction, White in finish, duly reinforced with 1.5mm thick GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have co- extruded with EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter: The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inwardopenable window shall be made of size 60w x 77h mm |
| 375 | Providing and fixing of UPVC casement openable windows (outward / inward): Outer Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction in Laminated (colour) finish, duly reinforced with 1.5mm thick GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have co-extruded with EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter: The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inward openable window shall be made of size 60w x 77h mm Extruded 3 box multi-chamber UPVC Window profile section of laminated( colour) having outer wall thickness of 2.25mm (+/- 0.2mm) provided withreinforcement of 1.5mm thick GI section duly mitered |
| 376 | Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of2.75mm (+/- 0.2mm) provided with reinforcement of2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazingbead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets |
| 377 | Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have co-extruded EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of laminated( colour) having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVCglazing |
| 378 | Providing and Fixing Aluminium composite panel of approved make 3mm thick with 0.5mm thick skin & PVDF coated approved shade for wall panelling. Main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. Stainless steel screw to be used to fix the ACP panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in allrespect as approved by Engineer-in-charge. |
| 379 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.). |
| 380 | Grade 304 |
| 381 | Grade 204 |
| 382 | Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction andsample approved by engineer-in-charge. |
| 383 | Providing & Fixing Aluminium composite panel of indo bond/euro/flexi bond of equivalent made 3mm that with 0.5mm thick skin& PVDF coated of approved shads for toilet door in double layer in Aluminium frame complete in all respect as per sample approvedby Engineer in Charges. |
| 384 | Removing aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directedby Engineer-in-charge. |
| 385 | Providing and Fixing powder coated aluminium angle corners of size 75 x 75 x 6mm over extruded/exposed corners of walls/colom etc. fixed with glazing tape on all four sides including filling of all inside edges of 6mm thickness with weather silicone sealant by backer rod of approved quality to make it completely air tight and water tight over the surface as per dirctionof Engineer-in-charge. |
| 386 | Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of20mm and 30mm long, the perimeter of ceiling fixed to |
| 387 | Providing and fixing calcium silicate board false ceiling at all heights including providing and fixing of frame work made of special sections power pressed fromM.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the calcium silicate board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mmcentre to centre with 25mm long drive-all screws @ |
| 388 | Providing and fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture as per direction of Engineer-in-charge of size 595 X 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm) consisting of main „T‟ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.33 mm thick (minimum) sheet, 1200mm centre to centre, and cross„T‟ of size 24X32mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main „T‟ at 600mm centre to centre to form a grid of 1200X600mm and secondary cross ‟T‟ of length 600mm and size 24X32mm made out of 0.33 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting......on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edgedcalcium silicate ceiling tiles of approved texture in the |
| 389 | Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clipsspaced at 1200mm center to center along main T, |
| 390 | Providing and fixing tiled false ceiling of approved materials of size 595X595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24X38 mm made from 0.30 mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24X25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200X600 mm and secondary cross “T” of length 600 mm and size 24X25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200X600 mm panel to form grids of 600X600 mm and wall angle of size 24X24X0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 X 37 X 25 X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanizedbutterfly level clips of size 85 X 30 X 0.8 mm spaced at |
| 391 | Providing & Fixing of Mineral Fibre Anti Bacterial Suspended Ceiling System with (Bevelled Tegular) EDGE TILES WITH 15 mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 95% Light Reflectance 90%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600 x 600 x 15 mm with Anti Microbial coating on the face of the tile, suitable for Green Building application, with Recycled content of 34 % The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2 & minimum pull out strength of 100 kgs. Silhouette, Main Runners & Cross Tees to have mitred ends & \\"birdsmouth\\" notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with suspension system of make. The Tile & Grid system used together should carry a 10 year warranty. INSTALLATION :- To comprise main runner spaced at 1200 mm centres securely fixed to the structural soffitusing suspension system (Specifications below) at |
| 392 | Renewing glass panes,with putty and nails wherevernecessary |
| 393 | Float glass panes of thickness 4 mm |
| 394 | Float glass panes of thickness 5 mm |
| 395 | Renewing glass panes with wooden fillets wherevernecessary : |
| 396 | 4mm thick plain glass panes. |
| 397 | 5mm thick plain glass panes. |
| 398 | Supplying and fixing new wooden fillets wherevernecessary: 2nd class teak wood fillets |
| 399 | Labour charges for repair to door / window without using any material such as applying randha (finishing)tightening of bolts & screw etc. |
| 400 | Repair of door, window shutters including cost ofmaterial and labour for change of damaged : |
| 401 | Style / rail of teak wood 30mm thick/ AluminiumSection |
| 402 | 4\\"wide |
| 403 | 6\\" wide |
| 404 | Panel by |
| 405 | Shuttering Ply - 9mm thick (Commercial) |
| 406 | Wire Gauge 14 mesh x 24 gauge |
| 407 | Plain Glass Panes 4mm thick |
| 408 | Aldrop of mild Steel |
| 409 | 12\\" long x12mm dia |
| 410 | 8\\" long x 10mm dia |
| 411 | Stopper of Aluminium with |
| 412 | Single Rubber Gutka |
| 413 | Double Rubber Gutka |
| 414 | Door Springs of mild Steel |
| 415 | Steel Hinges |
| 416 | For Wooden Chowkhat 3\\" size. |
| 417 | For Wooden Chowkhat 4\\" size |
| 418 | For Stone Chowkhat ,4\\"size |
| 419 | Mild Steel Tower Bolt 6\\" long |
| 420 | Steel Locking Bolt |
| 421 | Steel Handle 6\\" size |
| 422 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to matchthe colour / shade of wall treatment. |
| 423 | Non-asbestos fibre cement board 6 mm thick as perIS:14862. 1 |
| 424 | Aluminum fluted strips 2 mm thick |
| 425 | Acrylic sheet 5 mm thick |
| 426 | Part-C Painting Works |
| 427 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (forcolour changing only) |
| 428 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 429 | Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in allrespect. |
| 430 | Old work (One or more coats ) |
| 431 | Finishing wall with water proofing cement paint of approved brand and manufacture and or requiredshade to give an even shade including all scaffolding: |
| 432 | New work (Two or more coats applied @ 3.84 kg/10sqm). |
| 433 | Old work (One or more coats). |
| 434 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safetyprovision |
| 435 | Roller Finish av. thickness 400 to 500 microns. |
| 436 | Trowel Finish av. thickness 1000 to 1200 microns. |
| 437 | Applying priming coat : With ready mix pink or gray primer of approved brand and manufacture on woodwork hard and soft wood. |
| 438 | Varnishing with varnish of approved brand andmanufacture : |
| 439 | Two or more coats glue sizing with copal varnish overan under coat of flatting varnish. |
| 440 | Two or more coats glue sizing with spar varnish or anunder coat of flatting varnish. |
| 441 | French sprit polishing : |
| 442 | Two or more coats on new work including a coat ofwood filler. |
| 443 | One or more coats on old work. |
| 444 | Providing and applying Melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc completein all respect: |
| 445 | New Surface |
| 446 | Old Surface |
| 447 | Providing and applying superior quality emulsion for wall painting with Velvet touch/Royal paint etc of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in allrespect as per direction of Engineer-in-charge. |
| 448 | New Work Three or More coat |
| 449 | Old Work Analysis |
| 450 | Wall painting with Royal Play paint with various types of designs as approved of approved brand and manufacture to give an even shade including all scaffalding.Two or more coats on New work including preparation of base with primer, putty lippy etc. Complete in allrespect. |
| 451 | Face lifting (Doba Wash) with washing of stones by (1:20) acid & water solution, rubbing by brush, washing by clear water, pointing of damaged grooves & doba washing with good quality lime water and painting of doors, windows, ventilators upto all height & lead including all scaffolding and T&P etc. complete as per instructions and direction of Engineer-in-charge. |
| 452 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 453 | Two or more coats on new work |
| 454 | One or more coats on old work. |
| 455 | Providing and applying white cement based putty over plastered surface to prepare the surface even andsmooth complete |
| 456 | New Plastered Surface (three or more coats) |
| 457 | Old Plastered Surface (two or more coats) |
| 458 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding andsafety provision |
| 459 | New Work |
| 460 | Old Work |
| 461 | Applying one coat of Cement primer of approved brand and manufacture on wall surface including allscaffolding: |
| 462 | Part-D Sanitary Works |
| 463 | P. & F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excludingthe pair of foot rest.) |
| 464 | Size 450mm. |
| 465 | Size 510 mm |
| 466 | Size 580mm |
| 467 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and makinggood the wall and floor: |
| 468 | Size 530x410mm. |
| 469 | Size 580x440mm. |
| 470 | P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trapincluding cutting and making good the wall and floor |
| 471 | P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the walland floor |
| 472 | P & F Universal (anglo-Indian type) white glazed vitreous china W.C. pan 1st quality (IS 2556 Marked ) with P or S trap including cutting and making good thewall and floor. |
| 473 | P & F European type white glazed vitreous china 1st quality W.C. (IS : 2556 Mark) including cutting andmaking good the wall and floor |
| 474 | Wall Mounting |
| 475 | Wall Mounting (extended) |
| 476 | Wall Mounting (syphonic) |
| 477 | P & F water closet Seat Covers with brass hingescomplete : |
| 478 | Solid PVC (IS 2548 marked) grade-I Black for EWC. |
| 479 | -do- White. |
| 480 | -do- Coloured. |
| 481 | -do- White. |
| 482 | -do- Coloured. |
| 483 | P & F C.P. lugs for toilet seat cover. |
| 484 | Labour charges for removing W.C. pan (any type) of all sizes with care including all necessary fittings P orS trap. |
| 485 | P & F White glazed Conversion Bend for W.C. from Ptrap to S trap. . |
| 486 | P & F vitreous china P trap of approved quality |
| 487 | Add extra if C.I.P trap is used in place of Vitreouschina P trap for W.C. |
| 488 | P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings includingcutting and making good the wall and floor. |
| 489 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings,concealed iron brackets or screws etc complete. |
| 490 | Flat Back (small) size 456x355x265mm. |
| 491 | Flat Back (large) or half stall size 610x400x80mm. |
| 492 | Mini stall size 455x385x350mm. |
| 493 | P & F W.V.C. Urinal Partition Plate of approved standard make of size 630x315mm including makinggood the wall. |
| 494 | P&F Marble Urinal Partition slab both sides polished ofapproved design cut from marble size 900x600mm. |
| 495 | Makrana II quality marble having light spots |
| 496 | Makrana `Albeta` Marble having light streaks. |
| 497 | Makrana `Adanga` or Raj Nagar 1St Quality White orAndhi Indo-Italian marble. |
| 498 | P & F W.V.C. Half-Round Channel of approved make in C.M. 1:3, joints finished in white cementof: |
| 499 | Size 100mm dia. |
| 500 | Size 150mm dia. |
| 501 | P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & makinggood the floor: |
| 502 | Size 450x350mm |
| 503 | Labour charges for removing and refixing of urinals (all type & sizes) including all necessaryfittings. |
| 504 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting andmaking good the wall: |
| 505 | WVC with C.P. brass bend. |
| 506 | PVC with PVC bend as per IS : 7231 . |
| 507 | PVC with PVC bend and superior internal fittings asper IS : 7231 . |
| 508 | WVC for symphonic EWC. |
| 509 | PVC with CP brass long band as per IS : 7231 . |
| 510 | P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphon with copper tube, C.I. brackets complete including cuttingand making good the wall. |
| 511 | WVC (as per IS : 2556) 10 litres. |
| 512 | Deduct if plastic syphon is used. |
| 513 | P & F Flush Pipe of approved make with completefittings for high level flushing cistern: |
| 514 | G.I. `B` class (Concealed) 25mm. |
| 515 | G.I. `B` class (Concealed) 32 mm. |
| 516 | PVC exposed (heavy) 32mm. |
| 517 | GI (Sheet) hot galvanized exposed (10 litres). |
| 518 | P & F WVC (10 litres) low-level flushing cistern withcover. |
| 519 | P & F WVC (10 litres) low-level flushing cistern coveronly |
| 520 | P & F WVC syphon with plunger plate only. |
| 521 | P & F WVC Auto cistern with cover only. |
| 522 | P & F WVC Auto cistern cover only. |
| 523 | P & F C.P. brass Urinal Flush Pipe set completewith flanged brackets of approved make. |
| 524 | For 4 Urinals |
| 525 | For 3 Urinals |
| 526 | For 2 Urinals |
| 527 | For 1 Urinal |
| 528 | P & F C.P. brass Urinal Spreader for stall urinal ofapproved make. |
| 529 | P & F Synthetic (PTMT) Urinal Spreader for stallurinal of approved make. |
| 530 | P & F C.P. brass Doom Waste Coupling 32 mm dia. |
| 531 | P & F C.P. brass Doom Waste Coupling 40 mm dia. |
| 532 | P & F Plastic Syphon of approved make for automaticflush tank. |
| 533 | P & F Copper tube Syphon for auto flush tank. |
| 534 | Removing and re-fixing of wash hand basin includingall necessary fittings. |
| 535 | P & F metal brackets duly painted including cutting &making good the wall. |
| 536 | P & F C.P. Brass flush Valve with C.P. flush bend ofapproved make. |
| 537 | Lever type with Elbow 32 mm dia |
| 538 | Push type with Elbow 32 mm dia |
| 539 | Concealed type for 115 mm thick wall |
| 540 | Concealed type for 230 mm thick wall |
| 541 | Economy model 25 mm dia. |
| 542 | Economy model 32 mm dia. |
| 543 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting& making good the wall : |
| 544 | Size 450 mm x 300 mm |
| 545 | Size 510 mm x 400 mm |
| 546 | Size 550 mm x 400 mm |
| 547 | Size 580 mm x 450 mm |
| 548 | Size 610 mm x 510 mm |
| 549 | Size 400 mm x 400 mm or 450 mm x 390 mm Corner |
| 550 | 460 dia for counter top |
| 551 | Size 550 mm x 400 mm dia for counter top |
| 552 | Size 630 mm x 500 mm dia for counter top |
| 553 | Add extra for using 25mm GI waste pipe instead ofPVC waste pipe |
| 554 | P & F Terrazzo (Mosaic) wash hand basin with supporting brackets waste coupling and PVC waste pipe complete, including painting of brackets makinggood the walls: |
| 555 | 450 mm x 280 mm |
| 556 | 550 mm x 400 mm |
| 557 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling,C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting andmaking good the wall & floor : |
| 558 | Fire clay glazed kitchen sink (I.S 771-1985 Marked)size 600 x 450 x 250mm. |
| 559 | Fire clay glazed kitchen sink (I.S 771-1985 Marked)size 600 x 450 x 200 mm. |
| 560 | WVC Lab sink (IS:2556 mark) size 530 x 430 x 180mm |
| 561 | WVC Lab sink (IS:2556 mark) size 500 x 350 x 150mm |
| 562 | WVC Lab sink (IS:2556 mark) size 450 x 300 x 150mm |
| 563 | Mosaic fine polished kitchen sink size 600 x 450 x200mm. |
| 564 | Mosaic fine polished kitchen sink size 450 x 450 x200mm. |
| 565 | Mosaic fine polished kitchen sink size 600 x 450 x200 mm with 600 x 450mm drain board |
| 566 | 1.0 mm thick stainless steel AISI -304 & IS 13983- 1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. |
| 567 | Overall size Bowl size |
| 568 | (inches) (inches) |
| 569 | 18 x 16 x 6 16x14x6 |
| 570 | 22 x 18 x 7 20x16x7 |
| 571 | 24 x 18 x 8 20x16x8 |
| 572 | 37 x 18 x 7 17x15x7 (with drain board) |
| 573 | 45 x 20 x 8 20x16x8 (with drain board) |
| 574 | P & F Drain Board of approved make with C.I. brackets duly painted complete including cutting &making good the wall: |
| 575 | WVC (I.S.: 2556 Mark) size 530 x 450mm |
| 576 | Mosaic fine polished size 600 x 450 |
| 577 | P & F 1st quality WVC pedestal for wash basin. |
| 578 | MISCELLANEOUS |
| 579 | P & F Bottle Trap of approved make : |
| 580 | C.P Brass 32 mm |
| 581 | C.P Brass 40 mm |
| 582 | Synthetic Material (PTMT)32 mm |
| 583 | Synthetic Material (PTMT)42 mm |
| 584 | P.V.C |
| 585 | P& F waste Coulping with fittings of approved quality/make: |
| 586 | C.P Brass 32 mm dia |
| 587 | C.P Brass 40 mm dia |
| 588 | C.P. Brass 50 mm dia |
| 589 | SS 125 mm |
| 590 | P& F waste Pipe with all fitting |
| 591 | P.V.C with C.P nut 32 mm |
| 592 | P.V.C with PVC nut 32 mm |
| 593 | P.V.C. with C.P. nut 40 mm dia |
| 594 | G.I(B class) 32mm |
| 595 | G.I(B class) 40 mm |
| 596 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to woodenscrews & washers. |
| 597 | Size 600 x 450mm x 4 mm thick |
| 598 | Other sizes |
| 599 | For other quality mirrors from approved makemirrors deduct 30% |
| 600 | P & F Looking Mirrors with P.V.C. frame of approvedmake as per direction of Engineer-in-charge |
| 601 | Size 500x400mm |
| 602 | Oval shape 450x350 mm |
| 603 | Round 500mm dia |
| 604 | For other quality mirrors from approved makemirrors deduct 30% |
| 605 | P & F Toilet Shelf of approved quality/make: |
| 606 | W.V.C. (I.S.: 2556 Mark) Size 300mm |
| 607 | W.V.C. (I.S.: 2556 Mark) Size 550 mm |
| 608 | Synthetic Material with tumbler of approvedquality/make size 470 x 114 x 36mm |
| 609 | Hard Plastic of approved make as per direction of EI of size590x140mm |
| 610 | Acrylic shelf on C.P. brass casted brackets & guard rail of approved make as per direction of EI of size550x125mm |
| 611 | Glass Shelf with edges rounded off Anodised Aluminium angle frame & C.P. brass brackets & guardrail size 600x120mm |
| 612 | P & F Towel Rail or Ring of approved quality/make: |
| 613 | C.P. brass Towel Rail elbow type with concealedscrews size 450mm (Heavy duty). |
| 614 | C.P. brass Towel Rail elbow type with concealedscrews size 600 mm (Heavy duty). |
| 615 | C.P. brass towel rail with brackets 450 x 20mm. |
| 616 | C.P. brass towel rail with brackets 600 x 20mm. |
| 617 | Synthetic Material(PTMT) of approved quality/makesize 525 x90 x 75mm |
| 618 | Synthetic Material(PTMT) of approved quality/makesize 675 x90 x 75mm |
| 619 | WVC (1stquality, IS2556 Marked) of approved make.Recessed towel Hanger size 108 x 108mm. |
| 620 | C.P. Brass Towel Ring revolving type |
| 621 | Synthetic Material (PTMT) Towel Ring of approvedquality/make. |
| 622 | P & F Grating of approved quality/make: |
| 623 | Stainless Steel Sheet size 125mm dia. |
| 624 | Stainless Steel Sheet size 125mm dia. Heavy Qualityof approved make |
| 625 | Synthetic Material(PTMT) of approved quality/makesize 125mm dia. |
| 626 | (-do-) 150mm dia. |
| 627 | (-do-) Square 150 x 150 x 8mm. (Anti Cockroach) |
| 628 | C.P. brass with frame (Heavy) & superior quality size125mm dia. |
| 629 | (-do-) Light & superior quality size 125mm dia |
| 630 | Cast Iron. |
| 631 | P & F Liquid Soap Container with brackets completeof approved make: |
| 632 | C.P. brass |
| 633 | Synthetic Material of approved quality/make: |
| 634 | P & F Tooth Paste & Brush Holder of approvedquality/make: |
| 635 | C.P. brass |
| 636 | C.P. brass (Heavy and Superior quality) |
| 637 | Stainless Steel |
| 638 | P & F Toilet Paper Holder with rod of approvedquality/make: |
| 639 | C.P. brass |
| 640 | C.P. brass heavy & Superior quality. |
| 641 | WVC (1stquality, IS 2556 Marked) recessed size150x150mm. |
| 642 | (-do-) exposed (-do-) |
| 643 | P & F Soap Dish or Tray of approved quality/make |
| 644 | C.P. brass |
| 645 | C.P. brass heavy and superior quality. |
| 646 | WVC (1st Quality, IS 2556 Marked) recessed size150 x 150 mm. |
| 647 | (-do-) 200 x100mm. |
| 648 | (-do-) Soap tray 170mm. |
| 649 | (-do-) Soap Dish 380mm. |
| 650 | P & F Twin- peg of approved quality / make |
| 651 | C.P. brass |
| 652 | C.P. brass (heavy)Superior quality |
| 653 | Acrylic |
| 654 | P & F Shower arm 15mm dia of approvedquality/make. |
| 655 | C.P.brass heavy & superior quality 150mmProjection. |
| 656 | (-do-) size 220mm(-do-) |
| 657 | (-do-) size 300mm.(-do-) |
| 658 | (-do-) size 370mm.(-do-) |
| 659 | P & F Bath Shower of approved quality/make. |
| 660 | C.P. brass fixed. |
| 661 | C.P. brass of Heavy & superior quality 150mm. |
| 662 | C.P. brass of Heavy & superior quality, revolving withadjustable key 150mm. |
| 663 | P & F Extension Pipe for bib cocks of approvedquality/make. |
| 664 | C.P. brass of Heavy & Superior quality 50x15mm |
| 665 | (-do-) 100 X 15mm. |
| 666 | (-do-) 150 X 15mm. |
| 667 | P & F Acrylic Toilet accessories set consisting of Towel rail, shelf, towel ring, soap dish, paste & brushholder & twin peg of approved quality/make. |
| 668 | Labour Charges for removing WVC pan: |
| 669 | Indian/Orissa pan |
| 670 | European W.C. |
| 671 | Flushing cistern |
| 672 | P & F Jet spray for water closet with C.P. CopperTube flange of approved make. |
| 673 | Providing & fixing C.P.flange for 15mm dia taps. |
| 674 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to code IS : 15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding thecost of cement plaster on walls and pillar). |
| 675 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to code IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete(including the cost of cement mortar bed 1:4). |
| 676 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction ofEnginner-in-Charge |
| 677 | P & F C.P. brass Urinal Spreader for Large Urinal of heavy duty of approved make as per direction ofEnginner-in-Charge |
| 678 | Removing & Re fixing of P.V.C. Cistern fittings (Syphon, Ball cock & Handle Set) complete as perdirection of Enginner-in-Charge |
| 679 | Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-chargeincluding cutting and making good the wall and floor. |
| 680 | W.C. orissa pan with 100 mm vitreous china P or Strap (Size 580x440 mm.) |
| 681 | Universal (anglo-Indian type) with P or S trap |
| 682 | Wall Mounting European type W.C. |
| 683 | Double Syphonic European W.C. with mountedW.V.C. flushing cistern of 10 litre capacity complete with all necessary internal fittings with Hydraulic seatcover. |
| 684 | Providing & Fixing premium qulaity WVC Urinal with PVC waste pipe, dome couplings, concealed ironbrackets or screws etc. complete. |
| 685 | Flat Back (small) size 440x265x315 mm. |
| 686 | Flat Back (large) or half stall size 590x375x390 mm. |
| 687 | Providing & Fixing premium qulaity W.V.C. UrinalPartition plate of size 630x315 mm |
| 688 | Providing & Fixing premium qulaity WVC Wash basin with C.I. brackets duly painted & 32 mm C.P. brass waste coupling of approved make with PVC wastepipe complete |
| 689 | Size 550 mm x 400 mm |
| 690 | Size 550 mm x 400 mm dia for counter top. |
| 691 | P & F Premiumquality water closet Seat Covers with brass hinges complete Solid PVC (ISI marked) grade-IWhite for EWC. |
| 692 | P & F Premium quality Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make as per Engineer-in-charge with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and makinggood the wall : |
| 693 | P&F Looking Mirror 5mm thick of approved make with ornamental frame size 50x12 with 6mm Ply Board onBack Side Complete as per approved sample |
| 694 | Supply of Hydraulic Seat Cover for Europeon WC ofsuperior quality approved make in white Colour |
| 695 | Providing & Fixing chair for wall hung W.C. |
| 696 | Providing & Fixing Concealed cistern with Floor mounting frame and flush plate of superior quality andapproved sample by Engineer-in-charge. |
| 697 | Providing and fixing new spindle for Bib cock/pillar cock for repairing purpose to solve leakage and properfunctioning of tap. |
| 698 | Providing & Fixing premium quality Toilet corner Glass Shelf size 225x225mm with C.P. brass brackets &guard rail edges rounded of SS frame |
| 699 | Providing & Fixing premium quality waste coupling 32mm half thread as per approved by Engineer inCharge. |
| 700 | Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe& wall flange as per approved by Engineer in Charge. |
| 701 | P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls andfloors: |
| 702 | Exposed on wall |
| 703 | 15 mm dia nominal bore |
| 704 | 'A' Class |
| 705 | B' Class |
| 706 | 20mm dia nominal bore |
| 707 | 'A' Class |
| 708 | 'B' Class |
| 709 | 25mm dia nominal bore |
| 710 | 'A' Class |
| 711 | 'B' Class |
| 712 | 32mm dia nominal bore |
| 713 | 'A' Class |
| 714 | 'B' Class |
| 715 | 40mm dia nominal bore |
| 716 | 'A' Class |
| 717 | 'B' Class |
| 718 | 50mm dia nominal bore |
| 719 | 'A' Class |
| 720 | 'B' Class |
| 721 | 65mm dia nominal bore |
| 722 | 'A' Class |
| 723 | 'B' Class |
| 724 | 80mm dia nominal bore |
| 725 | 'A' Class |
| 726 | B' Class |
| 727 | Concealed pipe in wall including painting withanticorrosive bitumen paint |
| 728 | 15 mm dia nominal bore |
| 729 | 'A' Class |
| 730 | B' Class |
| 731 | 20mm dia nominal bore |
| 732 | 'A' Class |
| 733 | 'B' Class |
| 734 | 25mm dia nominal bore |
| 735 | A' Class |
| 736 | B' Class |
| 737 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching &refilling earth etc. |
| 738 | 15mm dia nominal bore |
| 739 | 'A' Class |
| 740 | 'B' Class |
| 741 | 20mm dia nominal bore |
| 742 | 'A' Class |
| 743 | 'B' Class |
| 744 | 25mm dia nominal bore |
| 745 | 'A' Class |
| 746 | 'B' Class |
| 747 | 32mm dia nominal bore |
| 748 | 'A' Class |
| 749 | 'B' Class |
| 750 | 40mm dia nominal bore |
| 751 | 'A' Class |
| 752 | 'B' Class |
| 753 | 50mm dia nominal bore |
| 754 | 'A' Class |
| 755 | 'B' Class |
| 756 | 65mm dia nominal bore |
| 757 | 'A' Class |
| 758 | 'B' Class |
| 759 | 80mm dia nominal bore |
| 760 | 'A' Class |
| 761 | 'B' Class |
| 762 | 100mm dia nominal bore |
| 763 | 'A' Class |
| 764 | B' Class |
| 765 | 125mm dia nominal bore |
| 766 | 'A' Class |
| 767 | 'B' Class |
| 768 | Making connection of G.I. distribution branch with G.I.main including all fitting. |
| 769 | Upto 25mm dia |
| 770 | Beyond 25mm & upto 100mm dia |
| 771 | Fixing water meter (IS: 779 mark) and stop cock inG.I. pipe line including making chamber of approved size excluding cost of water meter & stop cock. |
| 772 | P & F water meter (IS : 779 mark) of approved make. |
| 773 | 15mm dia |
| 774 | 20mm dia |
| 775 | 25 mm dia |
| 776 | The rates are for ISI marked item. |
| 777 | If the items are Non- ISI marked, reduce the rate by25%. |
| 778 | P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superiorquality and approved make: |
| 779 | C.P. Pillar cock, 15 mm dia nominal bore |
| 780 | C.P. Pillar cock Elbow action, 15 mmnominal bore. |
| 781 | C.P. Pillar cock fancy type ,15mmnominal bore. |
| 782 | C.P. Pillar cock, Swan-neck with casted spout, 15mmnominal bore. |
| 783 | C.P. Pillar cock, high-neck, 15 mm nominal bore. |
| 784 | Synthetic Material (PTMT) Pillar cock of approvedquality / make 15mm nominal bore. |
| 785 | P & F Bib Cock (IS : 8931 Mark), Superior quality ofapproved make: |
| 786 | Brass 400 gm,15mm nominal bore. |
| 787 | P.V.C.heavy duty, 15mm nominal bore. |
| 788 | C.P. Brass bib cock,15mm nominal bore. |
| 789 | (-do-) Long body, 15mm nominal bore weight not lessthan 690 gm |
| 790 | (-do-) Long nose, 15mm nominal bore weight not lessthan 810 gm |
| 791 | (-do-) Elbow-action, 15mm nominal bore. |
| 792 | Synthetic Material(PTMT) bib cock of approvedquality/ make, nominal bore, 15mm, 86 mm long. |
| 793 | (-do-) Fancy Type, 122 mm long. |
| 794 | (-do-) Long Body, 175 mm long |
| 795 | P & F Stop Cock (IS :8931 Mark), superior quality &of approved make: |
| 796 | Brass 400 gm. 15mm nominal bore. |
| 797 | (-do-) 750 gm. 20 mm nominal bore. |
| 798 | (-do-) 1350gm. 25 mm nominal bore. |
| 799 | C.P. Brass 15mm nominal bore. |
| 800 | (-do-) Concealed Stop Cock 15mm. |
| 801 | Synthetic material (PTMT) stop cock of approvedquality/make 15mm. |
| 802 | (-do-) Concealed stop cock 15mm |
| 803 | P & F Sink Cocks of superior quality & approved made: |
| 804 | C.P. Sink cock swinging spout 15mm. |
| 805 | (-do-) Casted Spout 15 mm. |
| 806 | P & F Push Cock superior quality, of approved make |
| 807 | C.P. Brass 15 mm. |
| 808 | Synthetic Material (PTMT) push cock of approvedquality/make 15mm. |
| 809 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C.Ball complete : |
| 810 | Brass wt. Not less than 300 gm,15mm. |
| 811 | Brass wt.Not less than 400 gm, 20mm. |
| 812 | (-do-) wt.Not less than 600 gm, 25mm. |
| 813 | (-do-) wt.Not less than 800 gm, 32mm. |
| 814 | (-do-) wt.Not less than 1000 gm 40mm.: |
| 815 | (-do-) wt.Not less than 1200 gm 50mm. |
| 816 | Synthetic material (PTMT) of approved make 15mmnominal size. |
| 817 | (-do-) 20 mm nominal size. |
| 818 | (-do-) 25 mm nominal size. |
| 819 | (-do-) 50 mm nominal size. |
| 820 | P & F Inlet Connection (Angle Valves) Superiorquality, of approved make, for Wash basin, Gyser etc. |
| 821 | C.P. Inlet connection 15mm.Brass (IS : 8931 marked) |
| 822 | ---do--- with 37 cm long pipe and nut. |
| 823 | ---do--- with 60 cm long thread and nut |
| 824 | Synthetic Material (PTMT) Inlet connection ofapproved quality/make 15 mm nominal size. |
| 825 | P & F 15 mm. Dia Connection Pipe of approvedquality/make : |
| 826 | PVC pipe with C.P. Brass nuts upto length, 300mm |
| 827 | (-do-) upto length 370mm |
| 828 | (-do-) 450mm. |
| 829 | (-do-) 600mm. |
| 830 | CP Brass Pipe with CP Brass nuts upto length300mm. |
| 831 | (-do-) 370mm. |
| 832 | (-do-) 450mm. |
| 833 | (-do-) 600mm. |
| 834 | P & F Flush Cock / Flush Valve (IS: 9758 Mark) for WC of approved quality make : |
| 835 | CP brass push type 15mm nominal bore. |
| 836 | (-do-) 20mm nominal bore. |
| 837 | (-do-)exposed 25mm nominal bore. |
| 838 | (-do-) 32mm nominal bore. |
| 839 | (-do-) concealed 25mm nominal bore. |
| 840 | (-do-) concealed 32mm nominal bore. |
| 841 | (-do-) Half-turn exposed 25mm nominal bore. |
| 842 | (-do-) Concealed 25mm nominal bore. |
| 843 | Brass / Gun metal Half-turn wt. 1 Kg. of approvedquality / make, 25mm nominal bore. |
| 844 | CP Brass flush valve 32mm nominal bore |
| 845 | P & F Full-way Valve (IS:778 Mark) or wheel valve ofapproved make : |
| 846 | Gun-metal 15mm nominal bore. |
| 847 | (-do-) 20mm nominal bore. |
| 848 | (-do-) 25mm nominal bore. |
| 849 | (-do-) 32mm nominal bore. |
| 850 | (-do-) 40mm nominal bore. |
| 851 | (-do-) 50mm nominal bore. |
| 852 | (-do-) 65mm nominal bore. |
| 853 | (-do-) 80mm nominal bore. |
| 854 | (-do-)100 mm dia nominal bore |
| 855 | P & F Gun-metal Non-return Valve or Check Valve (IS: 778 Make) of approved make, superior quality: |
| 856 | 15mm nominal bore. |
| 857 | Horizontal |
| 858 | Vertical |
| 859 | 20mm nominal bore. |
| 860 | Horizontal |
| 861 | Vertical |
| 862 | 25mm nominal bore. |
| 863 | Horizontal |
| 864 | Vertical |
| 865 | 32mm nominal bore. |
| 866 | Horizontal |
| 867 | Vertical |
| 868 | 40mm nominal bore. |
| 869 | Horizontal |
| 870 | Vertical |
| 871 | 50mm nominal bore. |
| 872 | Horizontal |
| 873 | Vertical |
| 874 | 32mm nominal bore. |
| 875 | P & F Oxidised Gas Taps, Bench-type of superiorquality and approved make: |
| 876 | One way |
| 877 | Two way |
| 878 | Three way |
| 879 | Four way |
| 880 | P & F Chromium plated Swan-neck LaboratoryCock of approved quality / make: |
| 881 | One way |
| 882 | Two way |
| 883 | Three way |
| 884 | Four way |
| 885 | P & F Spouts of superior quality and approved make: |
| 886 | C.P. brass spout |
| 887 | (-do-) Extra heavy with flange. |
| 888 | P & F Mixing Range (15mm) |
| 889 | C.P. One hole/close hole basin mixer with castedspout. |
| 890 | (-do-) with swinging spout casted. |
| 891 | C.P. sink mixer with swinging spout J-pipe. |
| 892 | (-do-) With casted spout. |
| 893 | C.P. valve mixer non-telephonic type. |
| 894 | C.P. wall mixer telephonic type crutch & telephonicshower. |
| 895 | (-do-) without crutch & telephonic shower. |
| 896 | C.P. Bath-tub mixer without telephonic shower butwith crutch. |
| 897 | C.P. Surgical basin mixer elbow action. |
| 898 | (-do-) with shower (wall type) |
| 899 | P & F Divertors of superior quality and approvedmake: |
| 900 | C.P. brass Tip-tone divertor bath spout with mixingvalve. |
| 901 | (-do-) Three way (-do-) |
| 902 | (-do-) Two way with 22Cm. Pipe flange |
| 903 | P & F foot valve of superior quality and approvedmake with fittings : |
| 904 | Brass 25 mm. |
| 905 | CI 50 mm |
| 906 | CI 65 mm |
| 907 | CI 80 mm |
| 908 | CI 100 mm |
| 909 | P & F Precast R.C.C. Water Storage Tank with R.C.C. cover 25mm thick and 15 Cm. Long G.I. over-flow pipe including making connections etc. & hoisting upto1M. ht. From ground level having: |
| 910 | 340 litres water capacity size 90 x 75 x 60 Cm. |
| 911 | 270 litres water capacity size 90 x 60 x 60 Cm. |
| 912 | Hoisting Charges of precast R.C.C. water storage tankon each floor : |
| 913 | 340 litres water capacity. |
| 914 | 270 litres water capacity. |
| 915 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, includingmaking connection etc., complete of approved design: |
| 916 | 200 litres capacity. |
| 917 | 300 (-do-) |
| 918 | 500 (-do-) |
| 919 | 750 (-do-) |
| 920 | 1000 (-do-) |
| 921 | 2000 (-do-) |
| 922 | 3000(-do-) |
| 923 | 5000(-do-) |
| 924 | Hoisting Charges for each floor : |
| 925 | For items 2.26.1 to 2.26.4 |
| 926 | For items 2.26.5 to 2.26.8 |
| 927 | Providing and fixing Bitumen Paint Coating over G.I.Pipes Complete as per Specifications. – |
| 928 | 15 mm dia |
| 929 | 20 mm dia |
| 930 | 25 mm dia |
| 931 | 40 mm dia |
| 932 | Supply & fixing G.I. Union ISI marked in G.I. pipe lineas required complete in all respect of size : |
| 933 | 15mm dia nominal bore |
| 934 | 20mm dia nominal bore |
| 935 | 25mm dia nominal bore |
| 936 | 32mm dia nominal bore |
| 937 | 40mm dia nominal bore |
| 938 | 50mm dia nominal bore |
| 939 | 65mm dia nominal bore |
| 940 | 80mm dia nominal bore |
| 941 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge |
| 942 | Pillar Cock 15 mm nominal size |
| 943 | Swan neck pillar cock 15 mm nominal size |
| 944 | Bib Cock with long thread 15 mm nominal size |
| 945 | Long body Bib Cock 15 mm nominal size |
| 946 | Two way Bib Cock 15 mm nominal size |
| 947 | Angular stop cock with long thread 15 mm nominalsize |
| 948 | Stop cock long thread |
| 949 | Stop cock with reduced body |
| 950 | Concealed stop cock 15 mm nominal size |
| 951 | Sink cock with swinging casted spout (table mounted )15 mm nominal size |
| 952 | Single lever wash basin mixer with 450 mm longcopper connection pipe |
| 953 | Central hole basin mixer |
| 954 | Wall mixer 3 in 1 system with provision of tetephonicbath shower with bend pipe |
| 955 | 600 mm long towel rail |
| 956 | Revolving type towel ring |
| 957 | Soap dish |
| 958 | Double coat hook |
| 959 | 190 mm rain shower |
| 960 | Shower arm |
| 961 | Paper holder |
| 962 | Hand shower with 8 mm dia 1 mt long PVC tube &wall hook complete |
| 963 | Health focet (Premium heavy Quality) as approved byEngineer-in-Charge |
| 964 | Jet Spray (Premium heavy Quality) as approved byEngineer-in-Charge |
| 965 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction ofEngineer in Charge. (Internal work Exposed on wall) |
| 966 | 15 mm nominal size |
| 967 | 20mm nominal size |
| 968 | 25 mm nominal size |
| 969 | 32mm nominal size |
| 970 | 40 mm nominal size |
| 971 | 50 mm nominal size |
| 972 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the wallsetc.,) |
| 973 | 15 mm nominal size |
| 974 | 20mm nominal size |
| 975 | 25 mm nominal size |
| 976 | 32mm nominal size |
| 977 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). |
| 978 | 15 mm nominal size |
| 979 | 20mm nominal size |
| 980 | 25 mm nominal size |
| 981 | 32mm nominal size |
| 982 | 40 mm nominal size |
| 983 | 50 mm nominal size |
| 984 | Providing and fixing Premium quality Towel rack 600mm long 260mm wide with lower hangers CP Brass fittings of approved make as per direction ofEngineer-in-charge |
| 985 | Labour Charges for Removing & Refixing the water Storage Tank of all sizes and including all Necessary fitting complete in all respect as per approved sampleand direction of engineer in charge. |
| 986 | Providing and fixing premium quality Angular stop cock 15mm with wall flange complete as per sampleapproved by Engineer in charge |
| 987 | Providing and fixing premium quality Two way Bib cock 15mm with wall flange complete as per sampleapproved by Engineer in charge |
| 988 | Providing and fixing superior quality PVC Tank Covercomplete as per approved by Engineer In Charge |
| 989 | 300 Lt. capacity |
| 990 | 500 Lt. capacity |
| 991 | Above 500 Lt. capacity |
| 992 | Providing & fixing C.I. Saddle pieces 100mm dia with nut & bolt & washer & Rubber Gasket complete as perdirection of engineer in charge |
| 993 | Supply and installation of Premium quality sluice valve 100mm dia including all fittings as per approved byEngineer in charge. |
| 994 | Providing Laying Jointing DI Pipe (Ductile iron pipe) of 100 mm dia ISI marked K-7 grade as per IS : 5329- 2000 with internal cement mortar lining for potable water with rubber ring (EPDM/ SBR) Joints per IS : 5382-1985 complete including Hydraulic testing &commissioning as per Technical Specification. |
| 995 | P&F Sluice valve of approved code IS 14846 : 2000make |
| 996 | 100 mm dia nominal bore |
| 997 | 75 mm dia nominal bore |
| 998 | P&F Divertors in water supply lines for walls, washbasin etc |
| 999 | P & F of Water Spout Superior Quality of approvemake. |
| 1000 | P&F Sink Mixture of (Adjustable or Non Adjustable)Superior quality Swan Neck. |
| 1001 | Providing Laying & jointing glazed S.W. pipes grade`A` (IS;651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1, excavation & refilling of earth in all types of soil upto 1.2m depth,S.W. fittings, including testing of joints etc, complete. |
| 1002 | 100mm dia |
| 1003 | 150mm dia |
| 1004 | 200mm dia |
| 1005 | 230mm dia |
| 1006 | 250mm dia |
| 1007 | 300mm dia |
| 1008 | 400mm dia |
| 1009 | If grade `AA S.W. pipes (IS:651 mark) are used thenadd 5% |
| 1010 | Deduct 5% if jointing is done in CM 1:3. |
| 1011 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete (Width W= Diameter of pipe inCm+30 Cm.)( Excluding cost of pipe) |
| 1012 | 100mm dia S.W. pipe |
| 1013 | 150mm dia S.W. pipe |
| 1014 | 200mm dia S.W. pipe |
| 1015 | 230mm dia S.W. pipe |
| 1016 | 250mm dia S.W. pipe |
| 1017 | 300mm dia S.W. pipe |
| 1018 | 350mm dia S.W. pipe |
| 1019 | 400mm dia S.W. pipe |
| 1020 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe.(Excluding cost of pipe) |
| 1021 | 100mm dia S.W. pipe |
| 1022 | 150mm dia S.W. pipe |
| 1023 | 200mm dia S.W. pipe |
| 1024 | 230mm dia S.W. pipe |
| 1025 | 250mm dia S.W. pipe |
| 1026 | 300mm dia S.W. pipe |
| 1027 | 350mm dia S.W. pipe |
| 1028 | 400mm dia S.W. pipe |
| 1029 | Providing & fixing S.W. square mouth Gully trap `A` grade (IS 651-1992 marked) of approved make &design in existing man-hole. |
| 1030 | Size 100 X 100mm |
| 1031 | Size 150 X 100mm |
| 1032 | Size 225 X 150mm |
| 1033 | P & F Square-mouth gully trap `A` grade (IS 651-1992:marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. |
| 1034 | Trap size 150 X 100mm, ferrow cement cover withframe, Internal Chamber size 300 X 300mm. |
| 1035 | Trap size 225 X 150 mm, ferrow cement cover withframe Internal Chamber size 450 X 450mm. |
| 1036 | P & F S.W. Master Trap (Inter-cepting) `A` grade (I.S.:651 marked) of approved quality/make |
| 1037 | 100mm dia |
| 1038 | 150mm dia |
| 1039 | Labour charges for Removing S.W. pipes including breaking of joints & bed concrete, stacking of useful material at site within 50 mtr. Lead and disposal ofunserviceable material within 0.5 Km. lead: |
| 1040 | 100 & 150mm dia pipe |
| 1041 | 200, 230 & 250mm dia pipe |
| 1042 | 300mm dia pipe |
| 1043 | 350mm dia pipe |
| 1044 | 400mm dia pipe |
| 1045 | R.C.C. NON PRESSURE PIPES |
| 1046 | Providing, Laying & Jointing R.C.C. class NP-2 Non- Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint includingtesting of joints etc. complete : |
| 1047 | 100mm dia Internal |
| 1048 | 150mm dia Internal |
| 1049 | 200mm dia Internal |
| 1050 | 250mm dia Internal |
| 1051 | 300mm dia Internal |
| 1052 | 450mm dia Internal |
| 1053 | 500mm dia Internal |
| 1054 | 600mm dia Internal |
| 1055 | 700 mm dia Internal |
| 1056 | 800 mm dia Internal |
| 1057 | 900 mm dia Internal |
| 1058 | Deduct 20 % for Non ISI marked pipes of all size |
| 1059 | SAND-CAST IRON SOIL, WATER & RAIN WATERPIPES. |
| 1060 | P & F Sand-cast Iron (S.C.I.) Pipe (IS : 1729mark) of approved make in wall or in floor with M.S. holder bat clamps in 10 X 10 X 10 Cm. M-15 grade concrete blocks, joints filled with CM 1:4 with spun yarnincluding cutting holes and making good the wall: |
| 1061 | 50mm dia |
| 1062 | 75mm dia |
| 1063 | 100mm dia |
| 1064 | 150mm dia |
| 1065 | Add extra for Lead caulked joints (IS:782-1978) insand cast iron pipes/spun- |
| 1066 | 75mm dia, 0.88 Kg. Pig lead |
| 1067 | 100mm dia, 0.98 Kg. Pig lead |
| 1068 | 150mm dia, 1.48 Kg. Pig lead |
| 1069 | P &F S.C.I. Fittings (IS : 1729 mark) in CM 1:4 withspun yarn. |
| 1070 | 50mm w/o door |
| 1071 | Socket |
| 1072 | Cowel |
| 1073 | 75 mm w/o door |
| 1074 | Offset |
| 1075 | Socket |
| 1076 | D/door Y-Tee |
| 1077 | Cowel |
| 1078 | Door Cross |
| 1079 | 100mm-do- |
| 1080 | Offset |
| 1081 | Socket |
| 1082 | D/door Y-Tee |
| 1083 | Cowel |
| 1084 | Door Cross |
| 1085 | 150mm w/o door |
| 1086 | Socket |
| 1087 | Cowel |
| 1088 | 50mm with door |
| 1089 | 75mm-do- |
| 1090 | 100mm-do- |
| 1091 | 150mm-do- |
| 1092 | P & F Sand –cast Floor Trap (Nahni) of (IS:1729 mark) of approved quality/make with socket down or hinged grating including cutting and making good thefloor. |
| 1093 | Size 100 x 100mm |
| 1094 | Size 100 x 75mm |
| 1095 | Size 100 x 50mm |
| 1096 | P & F Sand-cast Iron `P` or `S` Trap (IS:1729 make)of approved make. |
| 1097 | Labour charges for making connection of sewer linethrough main hole. |
| 1098 | Labour charges for removing C.I./A.C. pipes of all sizes including accessories with care and stacking ofuseful material. |
| 1099 | RIGID PVC PIPE |
| 1100 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg./Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 1101 | 63 mm dia |
| 1102 | 75 mm dia |
| 1103 | 110 mm dia |
| 1104 | 160 mm dia |
| 1105 | Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation oftrenches etc. |
| 1106 | PVC pipe 110 mm dia |
| 1107 | PVC pipe 160 mm dia |
| 1108 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe withsolvent cement rubber ring and lubricant: |
| 1109 | Coupler (socket) |
| 1110 | 75mm dia |
| 1111 | 110mm dia |
| 1112 | 160 mm dia |
| 1113 | Reducer 110 X 75 mm |
| 1114 | 75mm dia |
| 1115 | 110mm dia |
| 1116 | 160 mm dia |
| 1117 | Plain Tee |
| 1118 | 75mm dia |
| 1119 | 110mm dia |
| 1120 | 160 mm dia |
| 1121 | Door Tee |
| 1122 | 75mm dia |
| 1123 | 110mm dia |
| 1124 | 160 mm dia |
| 1125 | Door 'Y' |
| 1126 | 75mm dia |
| 1127 | 110mm dia |
| 1128 | 160 mm dia |
| 1129 | Double 'Y' |
| 1130 | 75mm dia |
| 1131 | 110mm dia |
| 1132 | 160 mm dia |
| 1133 | Double Door 'Y' |
| 1134 | 75mm dia |
| 1135 | 110mm dia |
| 1136 | 160 mm dia |
| 1137 | Bend 45 |
| 1138 | 75mm dia |
| 1139 | 110mm dia |
| 1140 | 160 mm dia |
| 1141 | Bend 87 .5 |
| 1142 | 75mm dia |
| 1143 | 110mm dia |
| 1144 | 160 mm dia |
| 1145 | Door Bend (Top Side) |
| 1146 | 75mm dia |
| 1147 | 110mm dia |
| 1148 | 160 mm dia |
| 1149 | Door Bend (Left & Right) |
| 1150 | 75mm dia |
| 1151 | 110mm dia |
| 1152 | 160 mm dia |
| 1153 | Vent Cowel |
| 1154 | 75mm dia |
| 1155 | 110mm dia |
| 1156 | 160 mm dia |
| 1157 | Socket plug |
| 1158 | 75mm dia |
| 1159 | 110mm dia |
| 1160 | 160 mm dia |
| 1161 | Door Cap |
| 1162 | 75mm dia |
| 1163 | 110mm dia |
| 1164 | 160 mm dia |
| 1165 | Pipe Clip |
| 1166 | 75mm dia |
| 1167 | 110mm dia |
| 1168 | 160 mm dia |
| 1169 | W.C. connector with lipring |
| 1170 | 110mm dia |
| 1171 | W.C. connector bent type |
| 1172 | 110mm dia |
| 1173 | Plain floor trap |
| 1174 | 110mm dia |
| 1175 | Multi floor trap |
| 1176 | 110mm dia |
| 1177 | height Raiser |
| 1178 | 110mm dia |
| 1179 | Top Tile& straine |
| 1180 | 110mm dia |
| 1181 | Top Tile only |
| 1182 | 110mm dia |
| 1183 | P- Trap |
| 1184 | 110mm dia |
| 1185 | Q- Trap |
| 1186 | 110mm dia |
| 1187 | S- trap |
| 1188 | 110mm dia |
| 1189 | Ring fitting |
| 1190 | 110mm dia |
| 1191 | Gully trap |
| 1192 | 110mm dia |
| 1193 | Raising manhole cover and frames slab to required level including dismantling existing slab and making good the damage as required (raising depth ofmanhole masonry to be paid separately). |
| 1194 | Rectangular manhole 90x60 cm |
| 1195 | Rectangular manhole 150x120 cm |
| 1196 | Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplusearth within 50 mtr. lead. |
| 1197 | Depth up to 0.5 M |
| 1198 | Add extra over item 3.19.1 for every additional 0.10mdepth above 0.5 m depth. |
| 1199 | Deduct in Item No 3.19.1 for manhole with brick work230 mm thick in place of 300 mm thick stone masonry |
| 1200 | Construction of Man hole, in all types of soil, inner size1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplusearth within 50 mtr. lead as per design : |
| 1201 | Depth up to 1.5 M |
| 1202 | Add extra over item 3.20.1 for every additional 0.10mdepth above 1.5 m depth . |
| 1203 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M- 15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within alead of 50 mtr. |
| 1204 | Inside size 300 X 300 mm depth upto 0.5 M Cementcover with frame. |
| 1205 | Deduct for using brick work 230 mm thick in place of300 mm thick stone masonry |
| 1206 | -do- size 450 x 450mm depth upto 0.5 M Cementcover with frame |
| 1207 | Deduct for using brick work 230 mm thick in place of300 mm thick stone masonry |
| 1208 | -do- size 600 x 450mm depth upto 0.5 M Cementcover with frame. |
| 1209 | Deduct for using brick work 230 mm thick in place of300 mm thick stone masonry |
| 1210 | -do- depth upto 0.5 M to 1.0 M –do- |
| 1211 | Deduct for using brick work 230 mm thick in place of300 mm thick stone masonry |
| 1212 | Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within alead of 50 mtr.: |
| 1213 | Size 300 Cm. dia outside & 300 Cm. depth . |
| 1214 | -do- & 240 Cm. Depth. |
| 1215 | Size 240 Cm. dia outside & 240 Cm. depth. |
| 1216 | Construction of soakage Trench in all types of soil with 300 mm thick dry stone masonry, 80 mm thick stone slab covering, jointing of slab in CM 1:3 Ralthal, Kharanja, 40 mm thick M-15grade C.C. flooring earthwork etc. complete as per approved drawingincluding disposal of earth within a lead of 50 Mtr.: |
| 1217 | Top width 180Cm., bottom width 90Cm. & depth240Cm. |
| 1218 | -do- 240 Cm., -do- 150Cm. & depth 300 Cm |
| 1219 | Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplusearth within a lead of 50 mtr . |
| 1220 | Inner dia 90 Cm & 10 to 12 Mtr deep. |
| 1221 | Inner dia 60 Cm & 10 to 12 Mtr deep. |
| 1222 | Labour charges for construction of Soakage well of 90 Cm. dia (Earth –work & its disposal ,with in a lead of0.5 Km .only ). |
| 1223 | Add extra if Soakage Well is filled with dry stones. |
| 1224 | Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplusearth within a lead of 50 mtr:- |
| 1225 | Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shutteringcomplete in all respect. |
| 1226 | Size 230 x110 x150 cm.(for 20 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shutteringcomplete in all respect. |
| 1227 | Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shutteringcomplete in all respect. |
| 1228 | Add or subtract proportionately for every 0.5 M increase or decrease in Length -12.5% Breadth &Depth -18 % each |
| 1229 | Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking outsewage including cleaning of site. |
| 1230 | Add extra if R.C.C slab of designed thickness & reinforcement is provided on manhole in place of stone slab( Actual area of R.C.C slab to bemeasured). |
| 1231 | P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded inwall & 10 cms. projected out complete. |
| 1232 | Supplying and fixing C.I. Cover with frame, C.I.gratings for chambers & man holes. |
| 1233 | Supplying and fixing Ferro- cement cover with C.I.frame for chambers & man holes of size. |
| 1234 | 450mm dia, 5Kg. C.I. frame to with stand 3 MT center point load & minimum unfractured load of 1 MT. (Lightduty). |
| 1235 | 500mm dia 12 Kg.-do-15 MT centre point load(medium duty). |
| 1236 | 500mm dia 22 Kg.-do-22 MT centre point load (Heavyduty). |
| 1237 | 500mm dia 25 Kg.-do-70 MT centre point load sealtype (Heavy duty.) |
| 1238 | Rectangular shape 600 x 450 mm, to withstand 3 MT center point load & minimum unfractured load of1 MT. (Light duty). |
| 1239 | Supplying & Fixing R.C.C. Manholes covers withframe of approved make (Light duty). |
| 1240 | Size 500mm dia (Double seal) |
| 1241 | Size 450mm dia |
| 1242 | Size 400mm dia |
| 1243 | Size 600 X 600mm (Double seal) |
| 1244 | Size 600 X 450mm |
| 1245 | Size 450 X 450mm |
| 1246 | Size 300 X 300mm |
| 1247 | Size 250 X 250mm |
| 1248 | Size 180 X 180mm |
| 1249 | Construction of Open Surface Drain with 112mm thick brick masonry in CM 1:4,110mm thick base concrete 1:5:10, 37mm thick M-15 grade C.C. flooring ,12mm 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earthcomplete as per approved design/drawing: |
| 1250 | 112mm drain,225mm Av. depth |
| 1251 | 150mm drain,225mm Av. depth |
| 1252 | 250mm drain,300mm Av. depth |
| 1253 | Construction of open Drain with 112mm thick brick masonry in CM 1:4 Semi circular S.W. glazed channel (confirming to IS Standards) fixed with cement mortar 1:1 over a bed of 100mm thick C.C. 1:5:10, filling of edged with M-15 grade C.C. flooring, 12mm cement plaster 1:4, over all exposed faces, excavation & disposal of earth with in a lead of 50 mtr complete asper approved drawings : |
| 1254 | 112 mm drain,225mm Av. depth width 10 Cm S.W.glazed channel. |
| 1255 | 150 mm drain,225mm Av. depth width 15 Cm S.W.glazed channel. |
| 1256 | 250 mm drain,225mm Av. depth width 25 Cm S.W.glazed channel. |
| 1257 | Extra For additional 5 Cm. Average depth of drain ofall sizes. |
| 1258 | P & F precast dense cement concrete (Vibro-pressed) drain section Block of different size as per approved drawing and design and strength as per IS code 2185 part I of grade 'D' (5.00mm2) proper quality of additive/admixture like plasticizer etc. added to produce high quality and durable drain section Blocks of 'L' shape 'U' shape etc. as per approved design and drawing complete with fixing and joining in C.M.1:4 in proper grade and level complete in all respect including earth work and disposal of surplus earth within 0.5 Km. lead. (cost of Steel/ welded mesh etc.shall be paid extra). |
| 1259 | 40mm thick |
| 1260 | Upto 60mm thick |
| 1261 | Upto 80mm thick |
| 1262 | Construction of Cement Concrete Chamber125mm dia. |
| 1263 | C.P. Brass grating |
| 1264 | C.P. Brass doom grating |
| 1265 | C.I. Grating |
| 1266 | Stainless Steel Sheet Grating |
| 1267 | Construction of Cement Concrete Chamber 125mm dia on depressed floor upto 45cm height from floorwith : |
| 1268 | C.P. Brass grating |
| 1269 | C.P. doom grating |
| 1270 | C.I. Grating |
| 1271 | Stainless Steel Sheet Grating |
| 1272 | SPUN-CENTRIFUGALLY CAST IRON SOIL WATERPIPES:- |
| 1273 | Providing & fixing Spun –Centrifugally cast Iron Pipes (IS : 3989 Mark ) of Approved make in wall or in floor with M.S. Holder bat clamps in 10 X 10 X10 Cm. M-15 Grade concrete blocks, joints filled with CM 1:4 with spun yarn including cutting holes and making good thewall:- |
| 1274 | 75 mm dia |
| 1275 | 100 mm dia |
| 1276 | 150 mm dia |
| 1277 | Providing & fixing Spun –Centrifugally cast Iron Pipesfitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn. |
| 1278 | 75mm w/o door |
| 1279 | Offset |
| 1280 | Socket |
| 1281 | D/Door Y-Tee |
| 1282 | Door Cross |
| 1283 | Cowel |
| 1284 | 100 mm –do- |
| 1285 | Offset |
| 1286 | Socket |
| 1287 | D/Door Y-Tee |
| 1288 | Door Cross |
| 1289 | Cowel |
| 1290 | 150 mm –do- |
| 1291 | Socket |
| 1292 | D/Door Y-Tee |
| 1293 | Door Cross |
| 1294 | Cowel |
| 1295 | 75mm with door |
| 1296 | Door Cross |
| 1297 | 100mm with door |
| 1298 | Door Cross |
| 1299 | 150mm with door |
| 1300 | Door Cross |
| 1301 | Providing and Fixing Spun –Cast Iron floor trap (Nahani) of (IS :3989 Mark ) approved quality / make with socket down or hinged grating including cuttingand making good the floor :- |
| 1302 | Size 100 x 100 mm |
| 1303 | Size 100 x 75 mm |
| 1304 | Add 10% extra Over Item No. 3.41 if the pipes are laidunder suspended condition under the roof. |
| 1305 | UPVC SOIL WASTE & RAIN WATER (SWR ) PIPES |
| 1306 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) ofapproved quality /make |
| 1307 | 75 mm dia |
| 1308 | 110 mm dia |
| 1309 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) ofapproved quality /make |
| 1310 | Coupler |
| 1311 | 75mm dia |
| 1312 | 110mm dia |
| 1313 | Repair Coupler |
| 1314 | 75mm dia |
| 1315 | 110mm dia |
| 1316 | Single Push Fit Coupler |
| 1317 | 75mm dia |
| 1318 | 110mm dia |
| 1319 | Bend 87.5 Dg. |
| 1320 | 75mm dia |
| 1321 | 110mm dia |
| 1322 | Bend 45 Dg. |
| 1323 | 75mm dia |
| 1324 | 110mm dia |
| 1325 | Door Bend 87.5 Dg. |
| 1326 | 75mm dia |
| 1327 | 110mm dia |
| 1328 | Single 'Y' |
| 1329 | 75mm dia |
| 1330 | 110mm dia |
| 1331 | Single 'Y' with Door |
| 1332 | 75mm dia |
| 1333 | 110mm dia |
| 1334 | Double 'Y' |
| 1335 | 75mm dia |
| 1336 | 110mm dia |
| 1337 | Double 'Y' with Door |
| 1338 | 75mm dia |
| 1339 | 110mm dia |
| 1340 | Socket Plug |
| 1341 | 75mm dia |
| 1342 | 110mm dia |
| 1343 | Pipe Clip |
| 1344 | 75mm dia |
| 1345 | 110mm dia |
| 1346 | Double tee with Door |
| 1347 | 75mm dia |
| 1348 | 110mm dia |
| 1349 | W.C. Connector |
| 1350 | 110mm dia |
| 1351 | W.C. Connector (Bend) with ring |
| 1352 | 110mm dia |
| 1353 | Single Tee |
| 1354 | 75mm dia |
| 1355 | 110mm dia |
| 1356 | Single Tee with Door |
| 1357 | 75mm dia |
| 1358 | 110mm dia |
| 1359 | Double Tee (4 Ways) |
| 1360 | 75mm dia |
| 1361 | 110mm dia |
| 1362 | Multi floor trap |
| 1363 | 110mm dia |
| 1364 | Offset |
| 1365 | 110mm dia |
| 1366 | Extra Square Jali |
| 1367 | 110mm dia |
| 1368 | Extra Round Jali |
| 1369 | 110mm dia |
| 1370 | Extra 4 SWR Ring |
| 1371 | 75mm dia |
| 1372 | 110mm dia |
| 1373 | Gully Trap |
| 1374 | 110mm dia |
| 1375 | Nahni Trap with Jali 4” |
| 1376 | 110mm dia |
| 1377 | Nahni Trap without Jali 4” |
| 1378 | 110mm dia |
| 1379 | Nahni Trap with Jali 3” |
| 1380 | 75 mm dia |
| 1381 | Nahni Trap without Jali 3” |
| 1382 | 75 mm dia |
| 1383 | Vent Cowel |
| 1384 | 75 mm |
| 1385 | Vent Cowel |
| 1386 | 110mm dia |
| 1387 | Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn 100mm w/o door as per direction of Engineer-in-Charge. |
| 1388 | P Trap of standard size |
| 1389 | Long P Trap (900mm) |
| 1390 | Long P Bend |
| 1391 | Long Floor Trap (600mm) |
| 1392 | Removing & Re fixing of S.C.I. Pipe and Spun Pipe with C.I.clip as per direction of Engineer-in-Charge offollowing diameters :- |
| 1393 | 100mm dia |
| 1394 | 150mm dia |
| 1395 | Cleaning of sewer line of various sizes as per requirement at site of different sizes including 100mm,150mm & 225mm dia of Stoneware pipe asper direction of Engineer-in-Charge. |
| 1396 | Cleaning of C.I. Pipe Line of various sizse as per requirement at site of different sizes including 100mm,150mm & 225mm dia of C.I.Pipes as perdirection of Engineer-in-Charge. |
| 1397 | Repairing of Cement Concrete Chambers of different size as per requirement at site and as per direction ofEngineer-in-charge. |
| 1398 | Providing & fixing Hubless Spun –Centrifugally cast Iron Pipes (IS : 15905 Mark ) of Approved make in wall or in floor with M.S. Holder bat clamps in 10 X 10 X10 Cm. M-15 Grade concrete blocks, joints filled with CM 1:4 with spun yarn including cutting holes andmaking good the wall:- |
| 1399 | 75 mm dia |
| 1400 | 100 mm dia |
| 1401 | 150 mm dia |
| 1402 | Providing & fixing Hubless Spun –Centrifugally cast Iron Pipes fitting (IS : 15905 Mark ) in CM 1:4 withspun Yarn. |
| 1403 | 75mm w/o door |
| 1404 | Offset (130mm) |
| 1405 | Shielded (SS) Coupling (With EPDM Rubber) |
| 1406 | D/Door Y-Tee |
| 1407 | Cowel |
| 1408 | 100mm W/o door |
| 1409 | Ofset (130mm) |
| 1410 | Shielded (SS) Coupling (With EPDM Rubber) |
| 1411 | D/Door Y-Tee |
| 1412 | Cowel |
| 1413 | 150mm W/o door |
| 1414 | Shielded (SS) Coupling (With EPDM Rubber) |
| 1415 | D/Door Y-Tee |
| 1416 | Cowel |
| 1417 | 75mm with door, bend |
| 1418 | 100mm with door |
| 1419 | Mechanised Cleaning of sewer line of diameter upto 200mm with the help of trolley mounted electrical driven machine having flexible steel springs of length 20ft. Each which are rotated with the help of electricmotor and clutch assembly. |
| 1420 | Mechanised sewer line Cleaning upto diameter 100mm with the help of PU coated glass fibre rodmounted on a wheel with brush attachment. |
| 1421 | Mechanised Cleaning and desilting of manhole/sewer line chambers With the help of mechanical bucketwhich gets open and close through levers. |
| 1422 | depth upto 0.5 mtr. |
| 1423 | Depth upto 1.0 mtr. |
| 1424 | Depth upto 2.0 mtr. |
| 1425 | Depth upto 3.0 mtr. |
| 1426 | Depth upto 5.0 mtr. |
| 1427 | Suplying and Fixing Ductile iron Man Hole Covers/storm water grating and gratingwith frame of various sizes weight and types and load bearing capacity as per EN -124 ,superior quality or equivalent, comlete as per Direction of Engineer Incharge. |
| 1428 | Providing and fixing circular air tight composite resin (FRP) manhole cover without frame of approved brand with grade designation C-250 HD as per EN-124 standard. Manhole Cover shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing in existing manhole frame etc. complete in all respectas directed by Engineer in Charge. |
| 1429 | Internal dia 0.56m |
| 1430 | Providing and fixing circular air tight composite resin (FRP) manhole cover without frame of approved brand with grade designation D-400 EHD as per EN-124 standard. Manhole Cover shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing in existing manhole frame etc. complete in all respectas directed by Engineer in Charge. |
| 1431 | Internal dia 0.56m |
| 1432 | Providing and fixing circular air tight composite resin (FRP) manhole cover with frame of approved brand with grade designation C-250 HD as per EN-124 standard. Manhole Cover & Frame shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing with M-20 concrete etc. complete in all respect asdirected by Engineer in Charge. |
| 1433 | Internal dia 0.56m |
| 1434 | Internal dia 0.60m |
| 1435 | Providing and fixing circular air tight composite resin (FRP) manhole cover with frame of approved brand with grade designation D-400 EHD as per EN-124 standard. Manhole Cover & Frame shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing with M-20 concrete etc. complete in all respect asdirected by Engineer in Charge. |
| 1436 | Internal dia 0.56m |
| 1437 | Internal dia 0.60m |
| 1438 | Providing and fixing rectangular air tight composite resin (FRP) Manhole Cover with frame of approved brand with grade designation C-250 HD as per EN- 124 standard. Manhole Cover & Frame shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing with M-20 concrete etc. complete in all respect asdirected by Engineer in Charge. |
| 1439 | Internal Size 0.45 m x 0.60 m |
| 1440 | Internal Size 0.45 m x 0.90 m |
| 1441 | Internal Size 0.60 m x 0.90 m |
| 1442 | Internal Size 0.90 mx 1.20 m |
| 1443 | Providing and fixing rectangular air tight composite resin (FRP) Manhole Cover with frame of approved brand with grade designation D-400 EHD as per EN- 124 standard. Manhole Cover & Frame shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing with M-20 concrete etc. complete in all respect asdirected by Engineer in Charge. |
| 1444 | Internal Size 0.45 m x 0.60 m |
| 1445 | Internal Size 0.45 m x 0.90 m |
| 1446 | Internal Size 0.60 m x 0.90 m |
| 1447 | Internal Size 0.90 mx 1.20 m |
| 1448 | Providing and fixing rectangular air tight composite resin (FRP) Grating with frame of approved brand with grade designation C-250 HD as per EN-124 standard. Grating with & Frame shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of 1.9mm after the application of 2/3 test load in five continuous application as per EN- 124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN- 124 standard including fixing with M-20 concrete etc. completein all respect as directed by Engineer inCharge. |
| 1449 | Internal Size 0.45 m x 0.45 m |
| 1450 | Internal Size 0.50 m x 0.60 m |
| 1451 | Internal Size 0.60 m x 0.75 m |
| 1452 | Internal Size 0.90 m x 0.60 m |
| 1453 | Internal Size 0.90 m x 0.90 m |
| 1454 | Internal Size 1.20 m x 0.60 m |
| 1455 | Providing and fixing rectangular air tight composite resin (FRP) Grating with frame of approved brand with grade designation D-400 EHD as per EN-124 standard. Grating & Frame shall have top abrasion resistant layer conforming to IS-15658:2006 and permissible permanent set value of1.9mm after the application of 2/3 test load in five continuous application as per EN-124, the testing shall be performed in fully equipped and NABL certified test lab with random batch test (2% of lot size) as per testing procedure stated in EN-124 standard including fixing with M-20 concrete etc. complete in all respect as directed byEngineer in Charge. |
| 1456 | Internal Size 0.45 m x 0.45 m |
| 1457 | Internal Size 0.50 m x 0.60 m |
| 1458 | Internal Size 0.60 m x 0.75 m |
| 1459 | Internal Size 0.90 m x 0.60 m |
| 1460 | Internal Size 0.90 m x 0.90 m |
| 1461 | Internal Size 1.20 m x 0.60 m |
| 1462 | Carriage of Building Rubbish Stone metal (Grit and ballast etc.) including loading and unloading with leadof 20km. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail