Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dispensary BuildingWiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 8 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 9 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 11 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 12 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. |
| 14 | 20 mm |
| 15 | 25 mm |
| 16 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 18 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 19 | Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 8Way (4+24), Double door |
| 20 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 21 | 8 way Double Door |
| 22 | 12 way Double Door |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Supplying and fixing following rating, Double plobe 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 27 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 29 | P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design. |
| 30 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 31 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 32 | 5/6 A switch |
| 33 | 3 pin 5/6 A socket outlet |
| 34 | Telephone socket outlet |
| 35 | TV antenna socket outlet |
| 36 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module |
| 37 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 38 | S/F of Heigh Bay LED Light 100 W IP66 & IK10 O/P upto 155lm/W highly , Crisp uniform and low glare illumination ease of installation with Factory fitted Eye bolt. |
| 39 | S/F pf 36/40 Watt LED batten al housing integrated electronic driver with connection test trial complete. |
| 40 | S/F of 300mm fresh air fan Double ball complete in all respect. |
| 41 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope , copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10% , remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise =75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 42 | S/F of LED 12W recess mounting downlighter robust PDC housing complete in all respect. |
| 43 | S/F of 20W LED Batten with al housing complete in all respect. |
| 44 | S/F of 36W 2x2 LED panel recessed mounted microprismatic diffuser complete with connection etc. as required. |
| 45 | Supply installation testing and commissioning of 400mm wall fan with fastners connection etc as required. |
| 46 | Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivatedBuilding LT Panel as per specification mentioned belowINCOMER 250 A, FP, MCCB ,50 KA - 1 No.OUTGOINGS Outgoing - 125 amp 35/36/38 KA FP MCCB -2no.,Outgoing - 100 amp 30KA FP MCCB-5nos, digital multifuntional meter module complete in all respects. |
| 47 | Providing Gyser (water Heater) 15 Liter Capacity. |
| 48 | S/F single pole blanking plate in the existing MCB DB complete etc. as required. (4 no. /MCBDB) |
| 49 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 50 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. For AC |
| 51 | Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc.as required. |
| 52 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate 2 Module for modular switches in recess including supplying and fixing Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required. |
| 53 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run |
| 54 | S/F of10W LED Batten. |
| 55 | S/F of 10 W LED Bulkhead pressure die cast housing with IP66 and IK09 complete. |
| 56 | Providing and fixing 100 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 57 | Providing and fixing 125 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 58 | S/laying of following aluminium conductor PVC insulated armoured served, sheathed cable 1100v direct in ground including excavation sand cushioniing protective covering and refilling the trench etc as required. |
| 59 | 150sqmm 3.5 core Al |
| 60 | 240sqmm 3.5 core Al |
| 61 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 62 | 3.5 X 150 sqmm |
| 63 | 3.5 X 240 sqmm |
| 64 | Providing, laying and fixing 100mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 65 | S/Laying of 50sqmm 3 1/2 core copper conductor PVC insulated armoured, served, sheathed cable 1100 direct in existing DWC pipe/ etc as required. |
| 66 | S/F of 40 amp/63 amp three pole MCB C Curve existing VTPN DB complete with connections, testing commisioning etc as required. |
| 67 | CAFETERIA |
| 68 | Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 69 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 70 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 71 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 72 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 73 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 74 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 75 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 76 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 77 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 78 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 79 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 80 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 81 | 20 mm |
| 82 | 25 mm |
| 83 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 84 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 85 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 86 | Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 4 Way (4+12), Double door |
| 87 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 88 | 8 way Double Door |
| 89 | 12 way Double Door |
| 90 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 91 | Single pole |
| 92 | Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 93 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 94 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 95 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 96 | P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design. |
| 97 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 98 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 99 | 5/6 A switch |
| 100 | 3 pin 5/6 A socket outlet |
| 101 | Telephone socket outlet |
| 102 | TV antenna socket outlet |
| 103 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module |
| 104 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 105 | S/F of High Bay LED Light 100 W IP66 & IK10 o/p upto 155lm/W highly efficient crisp Uniform and low glare illumination ease of installation with factory fitted eye bolt. |
| 106 | S/F pf 36/40 Watt LED batten al housing integrated electronic driver with connection test trial complete. |
| 107 | S/F of 300mm fresh air fan Double ball complete in all respect. |
| 108 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope , copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10% , remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise =75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 109 | S/F of LED 12W recess mounting downlighter robust PDC housing complete in all respect. |
| 110 | 9 watt decorative wall fitting brushed nickel finish fiture with opal glass diffuser with 9 watt LED lamp b22 base. |
| 111 | S/F of 36W 2x2 LED panel recessed mounted microprismatic diffuser complete with connection etc. as required. |
| 112 | Supply, Installation, Testing and Commissioning of 400mm wall fan with fastners, connection etc. as required. |
| 113 | Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivatedBuilding LT Panel as per specification mentioned belowINCOMER 250 A, FP, MCCB ,50 KA - 1 No.OUTGOINGS Outgoing - 125 amp 35/36/38 KA FP MCCB -2no.,Outgoing - 100 amp 30KA FP MCCB-3nos, digital multifuntional meter module complete in all respects. |
| 114 | Providing Gyser (water Heater) 15 Liter Capacity. |
| 115 | S/F single pole blanking plate in the existing MCB DB complete etc. as required. |
| 116 | Supplying and fixing following rating, Double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 117 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. For AC |
| 118 | Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 119 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate 2 Module for modular switches in recess including supplying and fixing Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required. |
| 120 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run |
| 121 | S/F of10W LED Batten. |
| 122 | S/F of20W LED Batten with al housing complete in all respect. |
| 123 | 10 W LED Bulkhead pressure die cast housing with IP66 and IK09 complete. |
| 124 | Providing and fixing 100 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 125 | Providing and fixing 125 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 126 | S/laying of 150sqmm 3 1/2 core Al aluminium conductor PVC insulated armoured served, sheathed cable 1100v direct in ground including excavation sand cushioniing protective covering and refilling the trench etc as required. |
| 127 | Supplying and making end termination with brass compression gland and aluminium lugs for 3 1/2 X 150 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 128 | Providing, laying and fixing 100mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 129 | S/F of 40 amp/63 amp three pole MCB C Curve existing VTPN DB complete with connections, testing commisioning etc as required. |
| 130 | Office Block-IWiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 131 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 132 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 133 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 134 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 135 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 136 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 137 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 138 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 139 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 140 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 141 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 142 | 20 mm |
| 143 | 25 mm |
| 144 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 145 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 146 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 147 | Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 4 Way (4+12), Double door |
| 148 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double Door |
| 149 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 150 | Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 151 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 152 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 153 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 154 | P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design. |
| 155 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 156 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 157 | 5/6 A switch |
| 158 | 3 pin 5/6 A socket outlet |
| 159 | Telephone socket outlet |
| 160 | TV antenna socket outlet |
| 161 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module |
| 162 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 163 | S/F pf 36/40 Watt LED batten al housing integrated electronic driver with connection test trial complete. |
| 164 | S/F of 300mm fresh air fan Double ball complete in all respect. |
| 165 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope , copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10% , remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise =75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 166 | S/F of LED 12W recess mounting downlighter robust PDC housing complete in all respect. |
| 167 | suply installation testing and commissioning of 400 mm wall fan with fastners connection etc. as required. |
| 168 | Providing Gyser (water Heater) 15 Liter Capacity. Make- jaguar/havells/racold. |
| 169 | S/F single pole blanking plate in the existing MCB DB complete etc. as required. |
| 170 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. |
| 171 | S/F of 10 W LED Bulkhead pressure die cast housing with IP66 and IK09 complete. |
| 172 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. For AC |
| 173 | Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 174 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate 2 Module for modular switches in recess including supplying and fixing Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required. |
| 175 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run |
| 176 | S/F of 20W LED Batten with al housing complete in all respect. |
| 177 | Providing and fixing 100 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 178 | S/F of 40 amp/63 amp three pole MCB C Curve existing VTPN DB complete with connections, testing commisioning etc as required. |
| 179 | Office Block-IIWiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 180 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 181 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 182 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 183 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 184 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 185 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 186 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 187 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 188 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 189 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. |
| 190 | 20 mm |
| 191 | 25 mm |
| 192 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 193 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 194 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 195 | Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 4 Way (4+12), Double door |
| 196 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double Door. |
| 197 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 198 | Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 199 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 200 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 201 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 202 | P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design. |
| 203 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 204 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 205 | 5/6 A switch |
| 206 | 3 pin 5/6 A socket outlet |
| 207 | Telephone socket outlet |
| 208 | TV antenna socket outlet |
| 209 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module |
| 210 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 211 | S/F pf 36/40 Watt LED batten al housing integrated electronic driver with connection test trial complete. |
| 212 | S/F of 300mm fresh air fan Double ball complete in all respect. |
| 213 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope , copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10% , remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise =75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 214 | S/F of LED 12W recess mounting downlighter robust PDC housing complete in all respect. |
| 215 | Providing Gyser (water Heater) 15 Liter Capacity. |
| 216 | S/F single pole blanking plate in the existing MCB DB complete etc. as required. |
| 217 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 218 | S/F of 10 W LED Bulkhead pressure die cast housing with IP66 and IK09 complete. |
| 219 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. For AC |
| 220 | Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 221 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate 2 Module for modular switches in recess including supplying and fixing Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required. |
| 222 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run |
| 223 | S/F of 20W LED Batten with al housing complete in all respect. |
| 224 | Providing and fixing 100 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 225 | S/F of 40 amp/63 amp three pole MCB C Curve existing VTPN DB complete with connections, testing commisioning etc as required. |
| 226 | Fire detection system Supplying, installation, testing & commissioning of intelligent analog addressable multicriteria detector complete with mounting base complete as required. |
| 227 | supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 228 | MANUAL CALL POINTSupplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 229 | HOOTER CUM STROBESupplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 230 | FIRE ALARM CONTROL PANEL.Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. TWO LOOP PANEL |
| 231 | REPEATER PANELSupplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 232 | Supplying and drawing 2X1.5 sqmm sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel/ PVC conduit as required. |
| 233 | Supplying and fixing of 25MM sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 234 | Fire hydrant system Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221 refilling the trench etc. of following sizes complete as required. 150mm dia |
| 235 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 236 | 25mm dia |
| 237 | 80mm dia |
| 238 | 100mm dia |
| 239 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed stainless steel |
| 240 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed stainless steel |
| 241 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 242 | 150mm |
| 243 | 100mm |
| 244 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 245 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 mtrs |
| 246 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) |
| 247 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe |
| 248 | S/F of ABC type fire extinguishers 6 kg MAP 90 complete with initial charges and wall bracket along with supply of all materials and labour for proper completion of work. |
| 249 | S/F of Co2 type fire extinguishers 4.5 kg gas based complete with initial charges and wall bracket along with supply of all materials and labour for proper completion of work.. |
| 250 | Ongrid solar photovoltaic Power PlantSupply, Installation, Testing and Commissioning of ongrid Solar photovoltaic Power Plant conforming to MNRE specifications asamended, consisting of Mono/PolyCrystalline silicon solar cells, netmetering facility, necessary protections, earthing mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330W porabove, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2.Solar Photo voltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power, plants/ systems must be warranted for their output peak watt capacity, which should notbe less than 90% at the end of 10years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800VDC 4wire, 50Hz+/-Input voltage range and 400VAC, three phase, 4wir 2.SHz, output voltage sultable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.) Fixing of Array junction box & Main Junction box with IP65 protection and termination arrang arrangement for incoming and outgoing cable alongwith glands, lugs and other accessories etc. as required.) Lightning and surge voltage protection.) Connections & Interconnections by supplying & fixing required ske XLPE Insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit alongwith supplying & fixing of necessary channel/ conduit lugs and other accessories etc, as required |
| 251 | Split ACSupply installation testing and commissioning 1.8-2.0TR air cooled split ( heaating+cooling) unit with 3 star invertor model. |
| 252 | S/F of 5KVA voltage stablizer with copper winding (range 130V-270V) |
| 253 | supply, Installation, Testing and Commissioning of additional refrigerant piping( two lenths 1/2 & 1/4) duly insulated with 25mm for indoor applications. |
| 254 | supply, Installation, Testing and Commissioning of PVC hard drain piping with fittings. |
| 255 | S/L of 4C x 1.5sq.mm PVC insulated flexible copper cable. |
| 256 | S/L of 3C x 2.5sq.mm PVC insulated flexible copper cable. |
| 257 | S/F of M.S. stand for outdoor Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail