| 1 | RENOVATION OF WTA FOR MAJOR RLI |
| 2 | Earth work in excavation of field trenches as per design section and alignment for laying of pipe lines (PVC, RCC, ACP etc.) upto a depth of 1500 mm all sorts of soils including removing, spreading or stacking extra earth as directed. The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete. |
| 3 | Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as perdirection of Engineer-in-Charge. |
| 4 | i) 140 mm Dia. PVC Pipe |
| 5 | ii)140 mm.OD. |
| 6 | ii)160 mm.OD. |
| 7 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 8 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). |
| 9 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.i) Pakur Variety. |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 11 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(i) Tor steel/Mild Steel |
| 12 | Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.) |
| 13 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] i) 15 mm thick plaster. (With 1:6 cement mortar) |
| 14 | Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 15 | Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. i) (i)(b) 100 mm dia. NB ERW/MS Pipes |
| 16 | Erection, fitting, fixing of set of M S/ G.I. Tripod set fittings for Mini RLI Scheme. (Rate inclusive of transportation from departmental store to work site). |
| 17 | Labour charges for fitting, fixing110 mm. Dia. Alfa-Alfa valve with 160mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete. |
| 18 | Labour charges for fitting, fixing (150 x 140) mm dia M S reducer with 140 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 140 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc. complete. For MINI RLI Scheme (Rate inclusive of transportation from departmental store to work site) |
| 19 | Labour charges for fitting and fixing of 150 & 100 mm dia. Sluice Valve |
| 20 | Supplying, fitting and fixing including transportation of sign board for identifying the exact location of RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C |
| 21 | Supplying 1 m x 0.6 m x 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. |
| 22 | Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge.i) For Mini R.L.I. |
| 23 | Add Extra Carriage @ 4% except Item No 1.01,1.11 & 1.23 |
| 24 | Add GST @ 18% (Item no 1.01 to 1.27) |
| 25 | Add Labour Welfare Cess @ 1% |
| 26 | Please Enable Macros to View BoQ information |