| 1 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500 mm |
| 2 | Labour for laying 150 mm to 200 mm boulder soling including rough dressing hand packing and ramming down small pieces in the interstics including rolling and preparing the bed to proper level and filling up all joints with sandy clay or earth. |
| 3 | Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 4 | (II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. VarietyIn ground floor(a) 1:3:6 proportion |
| 5 | Rubble masonry in cemen t(1:6) with hard dressed stones from approved quarries and clean, coarse and washed sand including carriage of all materials to site. (b) In Fine dressed work in Building(i) In Ground Floor |
| 6 | Ordinary Cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree |
| 7 | Plum concrete work with 40% cement concrete with 30 mm down graded stone metal and 60% stone boulder of size 150mm and above,placed in position as directed excluding shuttering if any. |
| 8 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel SAIL/TATA/RINL |
| 10 | 125mm. thickbrickworkwith1st class bricks incementmortar (1:4) inground floor. |
| 11 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screw sand lugs in ground floor.(Add extra @1% for each addl. floor upto 4th floor and @1.25% for each addl. floor above 4th floor)i) Grill weighing above 10Kg/sqmtr and upto 16 Kg./sq.mtr |
| 12 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968&IS: 1161-1998 ................................... all incidental chages such as electricity charges, labour insurance charges etc. i) For trusses spanning up to 12.00 m |
| 13 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS1038-1975 and manufactured from rolled steel sections conforming to IS7452-1974 with non-friction projecting type, boxtype hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete(1:2:4) with stone chips 20 mm down cutting holes andmending good damages to match with existing surface complete in all respect excluding glazing. (b)Openablesteelwindowsasper ISsizeswithsidehungshuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only] |
| 14 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local. |
| 15 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 16 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(b) 40mm X 6mm, 200mm Length |
| 17 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S.205/66) and fitted and fixed with cadmium plated screws:(v) 100 x 63 x 3.2mm |
| 18 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iii) 100mm long x 10mm dia. Bolt |
| 19 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(i) 250mm x 16mm dia bolt. |
| 20 | Anodised aliminiumD-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(iv) 125 mm grip x 10 mm dia rod. |
| 21 | Anodised aliminiumD-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(vi) 150 mm grip x 10 mm dia rod. |
| 22 | Plaster(towall, floor, ceilingetc.)withsandandcementmortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (a) 20 mm thick plaster |
| 23 | Plaster(towall, floor, ceilingetc.)withsandandcementmortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (b) 15 mm thick plaster |
| 24 | Neat cement punningabout 1.5mmthick inwall, dado,window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 25 | Acrylic Distemper to interior wall, ceiling with acoatofsolventbased interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats |
| 26 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification (iii) Two coats. |
| 27 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 28 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :With super gloss (hi-gloss) (iv) Two coats (with any shade except white) |
| 29 | (a)Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces b ysand papering etc. |
| 30 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) (iv) Two coats (with any shade except white) |
| 31 | Supplying best Indian sheet glass panes set inputty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick |
| 32 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete. A) UPVC PIPES ii) 110mm Dia |
| 33 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete.B) UPVC Fittings:c) Bend 87.5 degree (ii) 110 mm. Dia. |
| 34 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete.B) UPVC Fittings:d) Shoe (ii) 110 mm. Dia. |
| 35 | Galvanised corrugated iron sheet work (excluding the supporting framework) fitted and fixed with 10mm. dia J or L hook-bolts, limpet and bitumen washer sand putty complete with 150mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) (GCI sheet to be supplied by contractor) (i) In Roof: a) With 0.60 mm thick sheet |
| 36 | Galvanised iron sheet eaves gutter fitted and fixed with necessary 50mm X 6mm M.S flat bar clamps bent todesign, bolts, nuts, washers etc. complete.Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (a) 225 mm. wide gutter |
| 37 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)(A) 300 mm lapping each way(a) With 0.60 mm sheet Please Enable Macros to View BoQ information |