| 1 | Earth work in exacavation in foundations in ordinary soil (loam clay or sand) including lift upto 1.5 m and lead upto 30 mt. & including filling, watering and ramming of excavated earth into the trenches or into the space between building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 mt. from the foundation trenches. |
| 2 | Filling of earth in plinth in 20cm layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge.. |
| 3 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8.00Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work . |
| 4 | Cement Concrete with 4 cm gauge approved stone ballast approved coarse sand cement in the proportion of 8:4:1 including supply of all material T&P etc. required for proper completion of work |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m. |
| 6 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Plinth Beam / Lintel supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, T & P etc. required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 7 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, T & P etc. required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 8 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Lintel Beam supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, T & P etc. required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 9 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Footing supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, T & P etc. required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 10 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Column supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, T & P etc. required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 11 | TMT Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 12 | M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, T & P etc required for proper completion of the work. |
| 13 | M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus above but in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. |
| 14 | Class- 150 (Non Modular brick work tn 1:4 cement and coarse sand in foundation and plinth including supply of N materials, labour and T&P etc. required fo proper completion of the work. (Coarse Sand not less than 2.25 FM) in superstructure, 115 mm wide |
| 15 | Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apieceof cloth lightly soaked in kerosene oil |
| 16 | 15 mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand. |
| 17 | 12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and / or rounded angles not exceeding 80 mm in girth and finished even and smooth No. extra for mixing any additive. 1 cement : 6 Course sand |
| 18 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. 1 cement : 6 Course sand |
| 19 | Making grooves 10 to 12 mm wide x am deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 20 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 21 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with afloating coat Providing and laying vitrified floor tiles withou lean concrete in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.of neat cement on the rough side of single or half brickwall. |
| 22 | Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. |
| 23 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. (A) Door / windows & Staircase grill. |
| 24 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. (B)Z-Section windows ( Openable) |
| 25 | Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately |
| 26 | Hold fast |
| 27 | Fixing of Door, windows / ventilators chaukhats in position.(a) Door chaukhats |
| 28 | Fixing of Door, windows / ventilators chaukhats in position.(b) Window chaukhats |
| 29 | Fixing of Door, windows / ventilators chaukhats in position. (c) Ventilator chaukhats |
| 30 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick Single leaf |
| 31 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. |
| 32 | Providing stainless steel sliding bolts 16 mm dia with nuts and 300 mm long. (i) stainless steel |
| 33 | Providing stainless steel tower bolt with 10 mm dia and screw. (i) 300 mm long |
| 34 | Providing stainless steel door handles with screws 100 mm long. |
| 35 | Providing and fixing unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 36 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm |
| 37 | Bend 87.5° 110 mm bend |
| 38 | Shoe (Plain) 110 mm Shoe |
| 39 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 40 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 41 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 42 | Same as item no. 16 above but for wooden painting. |
| 43 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Ground floor |
| 44 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. Ground floor |
| 45 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) Ground floor |
| 46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Ground floor |
| 47 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying after surface preparation, first layer of slurry of cement @0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm |
| 48 | Providing & fixing glass panes with putty and glazing clipsin steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 49 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 50 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :(A) Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :(B)Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 52 | COST FOR ELECTRICAL WORKS (AS PER ESTIMATE) |
| 53 | COST OF PLUMBING WORKS (AS PER ESTIMATE) |
| 54 | COST OF SITE DOVELOPMENT (AS PER ESTIMATE) Please Enable Macros to View BoQ information |