| 1 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 2 | M&L PCC (1:3:6) type-C2withusing 40 mm graded crushed stoneaggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 3 | Demolition unreinforeced Concrete of any description and in any position not otherwise specifically provided for complete all as directed. |
| 4 | M&L PCC (1:2:4) type-B2withusing 40 mm graded crushed stoneaggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 5 | M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 6 | S&F MS work for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 7 | M&L TMT bar 10 mm diaand over, cut to length, bent to shape required, including cranking, hooking ends as in chain link fencing complete all as specified and as directed. |
| 8 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 9 | M&L preparation new iron and steel surfaces of any description, not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 10 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, Diameter of neck 5-10mm complete all as specified and directed. |
| 11 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed |
| 12 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed |
| 13 | Supply only chain link MS galvanized fencing 4mm dia and size as ordered, complete all as specified and as directed. |
| 14 | S&F Concertina coil 610mm dia, precoated with black anti-corrosive paint (weight 8Kg per coil expandable 6-8 mtr strech), short barb length 11+ 1mm thickness of tape 0.5mm, dia of spring core wire 2.6mm fixed on angle iron frames including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pin etc complete all as directed. |
| 15 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed. |
| 16 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6complete all as specified and directed. |
| 17 | M&L Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and smooth without using extra cement complete all as specified and as directed. |
| 18 | M&Lpreperation of new plastered surfaces and applying Two coats of cement base paint over a coat of primercomplete all as specified and directed. |
| 19 | Supply and install Window Air Conditioner unit complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR, complete all as specified and as directed. |
| 20 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 21 | S&F discharge copper pipe line heavy duty 3/8\" diaand flair nuts from indoor to outdoor unit of split AC 1.5 TRcapacity including Foam insulation, necessary clamping complete all as directed. |
| 22 | M&L Cutting openings, through brick wall (one brick thick) for fixing of window type Air Conditioner, providing second class hard wood frame (sectional size not less than 50mmx50mm),providing 2 coats of syntheic enamel paint over a coat of primer, on wooden frame, size as per AC modelincluding fair finish of side walls in cement mortar (1:6) and finishing the surfaces as per existing finishes, removing debries from the site complete all as specified and as directed. |
| 23 | S&F AC socket with MCB, DP 25 Amps, starter switch and socket with plug Top and indicator complete all as specified and directed. |
| 24 | M&L surface point wiring for One socket outlet 05/06 Amps point on independent board point complete controlled by Switch socket combination 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 25 | S&F Switch Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed. |
| 26 | S&F heavy duty wall mounted turbo air circulator metal blade fan, 400mm sweep, 230 Volts, with all fixing accessories such as nuts, bolts etc. as required dully clamped on wall complete all as specified and directed |