Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc., and stacking within 50 m lead of area 3 Sq.m and below complete all as specified and directed. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc., and stacking within 50 m lead of area beyond 3 Sq.m complete all as specified and directed. |
| 3 | Providing and fixing factory made UPVC white colour fixed glazed windows / ventilators comprising of UPVC multi-chambered frame and mullion (wherever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion |
| 4 | welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc., after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Glazing, paneling to be paid for separately) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 5 | Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriatedimension (area upto 0.75 sqm.). |
| 6 | Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white |
| 7 | powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kgs), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc., profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc., after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Glazing, paneling to be paid for separately) |
| 8 | Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof S.S wire mesh (two Nos. glazed & one No. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension (area of window below 1.75 sqm). |
| 9 | Providing and fixing factory made UPVC white colour casement / casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (wherever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc., profile of frame & sash shall be mitred cut and fusion |
| 10 | welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc., after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Glazing, paneling to be paid for separately) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) |
| 11 | made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (area of window upto 2.50 sqm). |
| 12 | Providing and fixing powder coated aluminium frame (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 & IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural |
| 13 | drawings and the directions of Engineer-in-Charge. (Glazing, paneling to be paid for separately) for fixed portion. |
| 14 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc., with EPDM rubber / neoprene gasket etc., complete as per the architectural drawings and the directions of Engineer-in-Charge (cost of aluminium snap beading shall be paid in basic item) with float glass panes of 4.0 mm thickness complete all as specified and directed. |
| 15 | Providing and fixing powder coated aluminium for shutters of door, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required powder coated aluminium (minimum thickness of powder coating 50 microns) complete all as specified and directed. |
| 16 | Providing and fixing factory made UPVC door frame, made of uPVC extruded sections of size 65 mm x 55 mm with wall thickness 2.0 mm (+ 0.2 mm), corners of the door frame to be miltred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of size 28 mm x 30 mm having wall thickness 2 mm (+ 0.2 mm), including providing and fixing 03 Nos. of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners all as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 17 | Providing and fixing to existing door frames 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59 x 24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20 x 20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100 x 24 mm and 2 mm (± 0.2 mm) wall |
| 18 | thickness, fixed to the shutter styles by means of plastic / galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 19 | Providing and fixing factory made single extruded frame size 65 x 100 mm WPC (Wood Polymer Composite) solid door / window / Ceosetory windows & other frames / chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body thread star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to |
| 20 | spread of flame of class \"A\" category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position with M.S hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S hold fast / lugs shall be paid for separately).Note: For WPC solid door / window frames, minus 5 mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 21 | Providing and fixing factory made single extruded 35 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class \"A\" category with property of being termite / borer proof, water / moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 |
| 22 | microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as per direction of Engineer-in-Charge.Note: Stainless steel butt hinges shall be paid separately. |
| 23 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc., complete 150 x 10 mm complete all as specified and directed. |
| 24 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc., complete 100 x 10 mm complete all as specified and directed. |
| 25 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc., complete 125 mm complete all as specified and directed. |
| 26 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc., complete 100 mm complete all as specified and directed. |
| 27 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc., complete 300 x 16 mm complete all as specified and directed. |
| 28 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc., complete 250 x 16 mm complete all as specified and directed. |
| 29 | Providing and fixing ISI marked MS pressed butt hinges bright finished with necessary screws etc., complete 100 x 58 x 1.90 mm complete all as specified and directed. |
| 30 | Providing and fixing ISI marked MS pressed butt hinges bright finished with necessary screws etc., complete 75 x 47 x 1.70 mm complete all as specified and directed. |
| 31 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS:3564, embossed on the body, door weight upto 36 kgs to 80 kgs and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc., complete all as specified and directed. |
| 32 | Providing and fixing aluminium hanging floor door stopper ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc., single rubber stopper complete all as specified and directed. |
| 33 | Providing and fixing brass curtain rods 20 mm diameter of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc., wherever necessary complete all as specified and directed. |
| 34 | Dismantling 15 to 40 mm dia GI pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. |
| 35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 15mm nominal dia pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge concealed work, including cutting chases and making good the walls etc., complete all as specified and directed. |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 20mm nominal dia pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge concealed work, including cutting chases and making good the walls etc., complete all as specified and directed. |
| 37 | Dismantling CI or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 100 mm dia pipe metre 64.30 complete all as specified and directed. |
| 38 | S&F, (SWR) PVC pipes 110 mm dia single socketed in any length with rubber ring joints laid under floor or on walls fixed as soil waste / vent pipes including taking up or down existing PVC / CI pipes and connections complete all as specified and directed. |
| 39 | Dismantling CI or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 75 to 80 mm dia pipe complete all as specified and directed. |
| 40 | S&F, (SWR) PVC pipes 75 mm dia single socketed in any length with solvent cement joints laid under floor or on walls fixed as soil waste / vent pipes including taking up or down existing PVC pipes and connections complete all as specified and directed. |
| 41 | S&F, PVC (SWR) bends any radius, 75 mm bore with / without access door complete all as specified and directed. |
| 42 | S&F, PVC (SWR) floor trap with and including, plain / single hole chromium plated grating including jointing to waste pipe with solvent cement, 75 mm dia complete all as specified and directed. |
| 43 | S&F, PVC (SWR) bends any radius, 110 mm bore with / without access door complete all as specified and directed. |
| 44 | S&F, 75 mm dia outlet cast iron nahani trap with grating as fixed in repairs complete all as specified and directed. |
| 45 | Dismantling WC pan of all sizes including disposal of dismantled materials including malba complete all as specified and directed. |
| 46 | Providing and fixing white vitreous china pedestal type water closet (European type WC pan) with seat and lid, 10 litres low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required WC pan with ISI marked white solid plastic seat and lid complete all as specified and directed. |
| 47 | Providing and fixing water closet squatting pan (Indian type WC pan) with 100 mm sand cast iron P or S trap, 10 litres low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : white vitreous china orissa pattern WC pan of size 580 x 440 mm with integral type foot rests complete all as specified and directed. |
| 48 | Vitreous china urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe of size 580 x 380 x 350 mm including painting of fittings and cutting and making good the walls and floors wherever required as per the direction of Engineer-in-Charge. |
| 49 | Providing and fixing wash basin on granite platform, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china wash basin size 630 x 450 mm with single 15 mm CP brass pillar taps complete all as specified and directed. |
| 50 | Providing and fixing stainless steel \"A\" ISI:304 (18/8) kitchen sink with drain board of size 510 x 1040 mm bowl depth 250 mm as per IS:13983 with CI brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required complete all as specified and directed. |
| 51 | Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete 32 mm dia flexible pipe complete all as specified and directed. |
| 52 | Providing and fixing CP brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore complete all as specified and directed. |
| 53 | Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 : 15 mm nominal bore complete all as specified and directed. |
| 54 | Providing and fixing CP brass angle valve 15 mm bore complete all as specified and directed. |
| 55 | Providing and fixing CP brass shower rose with 15 or 20 mm inlet 100 mm diameter complete all as specified and directed. |
| 56 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length and 15 mm nominal bore complete all as specified and directed. |
| 57 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete all as specified and directed. |
| 58 | S&F, health faucet, brass body with 1 mtr SS braided rubber hose pipe and wall hook complete all as specified and directed. |
| 59 | Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws complete 300 mm weighing not less than 330 gms complete all as specified and directed. |
| 60 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms complete all as specified and directed. |
| 61 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing rectangular shape 453 x 357 mm complete all as specified and directed. |
| 62 | Disconnecting damaged overhead / terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level complete all as specified and directed. |
| 63 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, 1000 litres capacity, IS:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed. |
| 64 | Providing and fixing ball valve (brass) of approved quality, high or low pressure with plastic floats 25 mm nominal bore complete all as specified and directed. |
| 65 | Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end) 20 mm nominal bore complete all as specified and directed. |
| 66 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead, nominal concrete 1:3:6 or richer mix (including equivalent design mix) complete all as specified and directed. |
| 67 | Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) of specified grade, 75 mm thick, excluding the cost of centering and shuttering - all work upto plinth level, as in paving / plinth protection laid in panels, finished even and smooth without using extra cement complete all as specified and directed. |
| 68 | Demolishing cement concrete for floor manually / by mechanical means including disposal of material within 50 metres lead, nominal concrete 1:3:6 or richer mix (including equivalent design mix) complete all as specified and directed. |
| 69 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 70 | Providing and laying glazed vitrified tiles matt / anti skid finish size of tile 600 x 600 mm sqm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved brand & manufacturer in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 71 | Providing and laying glazed vitrified floor tiles polished finish size of tile 600 x 600 mm sqm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved brand & manufacturer in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 72 | Providing and laying vitrified floor tiles size of tile 600 x 600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments complete all as specified and directed. |
| 73 | Providing and laying 25 mm second class teak wooden planking, tongued and grooved in flooring including fixing with iron screws complete all as specified and directed. |
| 74 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 75 | Providing and fixing 18 mm thick granite stone slab colour black, cherry / ruby red gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc., complete at all levels complete all as specified and directed. |
| 76 | M&L for Kota stone slab flooring 20 mm thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed. |
| 77 | M&L for Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete all as specified and directed. |
| 78 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 meters lead, nominal concrete or leaner mix (including equivalent design mix) complete all as specified and directed. |
| 79 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 80 | M&L for Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc., on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) light shade pigment using white cement complete all as specified and directed. |
| 81 | Remove the existing APP membrane treatment totally and clean the surface thoroughly and then check any structural defects or cracks complete all as specified and directed. |
| 82 | M&L for Poly Urethane based water proofing treatment to existing RCC roof slab with the following specifications: -i) Cleaning the existing surface by mechanical means to make it free from any bituminous residue / dirt, oil and grease all as directed by Engineer-in-Charge.ii) M&L for cracks treatment by cutting open cracks and cleaning it from dirt, loose materials and filling with Polyurethane based sealant with and including application of PU based primer all as directed by Engineer-in-Charge. |
| 83 | iii) M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC compound) in three coats including one coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by Engineer-in-Charge.Note: Properties of Poly urethane based chemical shallconform to following technical parameters: -a) Highly elastic.b) UV resistance.c) Adhesion to concrete > 1N/Sqmm.d) Tensile strength-not less than 2.0 N/Sqmm for free film elongation not less than 300%.e) Solid content by weight not less than 60%. |
| 84 | f) Air / Water permeability BSEN 12390 at 5 bar-72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.00 mm.g) Accelerated weathering (ASTM 453) Pass 1000 hours.h) Reaction to fire - Non inflammable. |
| 85 | Demolishing brick in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 86 | Providing and laying factory made precast concrete solid blocks of 200 mm thickness of grade M-10 made of C&D waste from approved manufacturer in superstructure above plinth level upto floor V level in cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed. |
| 87 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 88 | M&L for 12 mm cement plaster of mix 1:4 (1 cement : 4 fine sand) complete all as specified and directed. |
| 89 | M&L for 12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand) complete all as specified and directed. |
| 90 | M&L for 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) complete all as specified and directed. |
| 91 | Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers 50 kgs cement used in the mix complete all as specified and directed. |
| 92 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches complete all as specified and directed. |
| 93 | Distempering with 1st quality acrylic distemper (ready mix) having VOC content less than 50 gm per ltr, of approved manufacturer and of required shade and colour as per manufacturer\"s specification one or more coats on old work complete all as specified and directed. |
| 94 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two coats) over and including water thinnable priming coat with cement primer complete all as specified and directed. |
| 95 | M&L for complete removal of existing treatment and finishing walls with 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives. New work (two coats applied @ 1.43 litre/10 sqm) over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified and directed. |
| 96 | M&L for complete removal of existing treatment and finishing walls with acrylic smooth exterior paint of required shade having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives : old work (two coats applied @ 1.67 litre/10 sqm) on existing cement paint surface complete all as specified and directed. |
| 97 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two coats on new work complete all as specified and directed. |
| 98 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) complete all as specified and directed. |
| 99 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead thickness above 10 mm upto 25 mm complete all as specified and directed. |
| 100 | Supply and fixing, 15 mm beveled tegular with suprafine 15mm T grid channels and accessories complete. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥ 85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 Pt - 6 &7) in module size of 600 x 600 x 15 mm, suitable for Green Building application with Recycled content of 66% GW & 74% RW. The tile shall be laid on suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm cross tees with a web height of 32 mm and a load carrying capacity of 7.5 |
| 101 | Kgs/Sqm with a minimum pull out strength of 100 kgs. The T sections have a galvanizing of 90 grams per Sqm and need to be installed with suspension system and necessary angle complete all as specified and directed. |
| 102 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead complete all as specified and directed. |
| 103 | Providing and supplying ‘Wall Paneling’ Supply and fixing acoustic wall panelling with tuck and track PVC profiles with suitable 50 mm infill and finishing with 2 shade stretch fabric system with square edges made of fibre glass substrate 25 mm thick and wrapped on the front side with an acoustically transparent and classified for fire reaction class A as per ASTM E-84, fabric with an option of colors - Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut & Shell as per the choice of the Architect of size 600 x 600 mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using wall panel impalers and necessary aluminium frame work supplied by M/s Armstrong Industries |
| 104 | India Pvt Ltd and construction adhesives as per the instructions laid down by the manufacturer complete all as specified and directed. |
| 105 | Providing and fixing cupboard shutter with 19 mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS-710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc., with auto closing spring loaded hinges (hydraulic type) complete all as specified and directed. |
| 106 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc., double strip (horizontal type) complete all as specified and directed. |
| 107 | Dismantling roofing including ridges, hips, valleys and gutter etc., and stacking the material within 50 metres lead of : asbestos cement sheet complete all as specified and directed. |
| 108 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS:14871) roofing upto any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia GI plain and bitumen washers or with self drilling fastener and EPDM washers etc., (excluding the cost of purlins, rafters and trussers), including cutting sheets to size and shape wherever required complete all as specified and directed. |
| 109 | M&L for steel work in built up tubular (round, square or rectangular hollow tubes) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc., hot finished welded type tubes complete all as specified and directed. |
| 110 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two coats on new work complete all as specified and directed. |
| 111 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding |
| 112 | the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed. |
| 113 | Demolishing stone rubble masonry in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 114 | M&L for random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed. |
| 115 | M&L for providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., upto floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 116 | Demolishing RCC work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 117 | Providing and placing in position precast reinforced cement concrete waffle units, square or rectangular, as per design and shape for floors and roofs in 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 10 mm nominal size derived from natural sources), including flush or deep ruled pointing at joints in cement mortar 1:2 (1 cement : 2 fine sand), form work in precasting, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement for slabs and similar complete all as specified and directed. |
| 118 | Steel reinforcement for RCC work including straightening, cutting, bending, placing, in position and binding all complete above plinth level thermo-mechanically treated bars of grade Fe-500 D or more complete all as specified and directed. |
| 119 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with |
| 120 | suitable arrangement as per approval of Engineer-in-Charge (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) complete all as specified and directed. |
| 121 | S&F in position alphabetical letters in Hindi or English and signs arrows etc, made of stainless steel sheet of grade SS-304 L of thickness 1.00 mm and fixing to MS sheet cladding with necessary fixing arrangements size of each letter upto 45 cm in height and thickness of letter 40 mm so as give a shape of 3D complete all as specified and directed. |
| 122 | Taking down carefully old and unserviceable aluminium point wiring for light / fan / socket or power point complete including fittings such as switches, ceiling rose, pendants, regulators, sockets, bell, distribution boards and MCB\"s etc., and making good disturbed surface of walls, floors etc., to match with the existing surface complete all as specified and directed. |
| 123 | Point wiring for light / fan / exhaust / wall mounted fan point with 2 x 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface / concealed medium class PVC conduit 25 mm dia with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc., as required complete all as specified and directed. |
| 124 | Point wiring for 5 Amps socket outlet point on independent board with 2 x 1.5 sq mm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS-694 marked with multistranded copper conductors and earth continuity wire with similar 1 x 1.5 sq mm cable (including connecting to earth dolly) drawn through and single core cable in surface / recessed medium class PVC conduit as required at site complete all as specified and directed. |
| 125 | Wiring for circuit / submain wiring alongwith earth wire with the size of2 x 1.5 aq.mm + 1 x 1.5 sq.mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 126 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket, connection etc., as required atsite (for independent & same board 5 Amps power plug) complete all as specified and directed. |
| 127 | Wiring for circuit alongwith earth wire with the size of wire 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 128 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modular socket, connection etc., as required at site (for 15/16 power plug / socket) complete all as specified and directed. |
| 129 | S&F, 3 pin, 5 A ceiling rose on the existing junction box / wooden block including connections etc., as required complete all as specified and directed. |
| 130 | S&F, LED light fitting 20 W surface and wall mounted LED batten with aluminium housing & integrated electronic driver 20 W with one no LED tube, including connecting up with three core flexible copper conductor of suitable size complete all as specified and directed. |
| 131 | S&F, LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220v AC decorative type with driver holder and LED Lamp including connecting up with three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 132 | S&F in replacement of building security light fitting LED 36 W, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection, system lumen : 120lm/w, dimension 320 x 135 x 52 and impact resistance of IK-07 with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to suitable shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS clamps of size 40 x 5 mm - 02 Nos, nuts, bolts and washers on wall including removing unserviceable security lights any type and size complete all as specified and directed. |
| 133 | Taking out existing old unserviceable flood lights any type and size andS&F, LED flood light fitting 70 watts, 140 V - 270 V, 50Hz AC outdoor type with high pressure die cast aluminium housing with top opening service and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, light source high efficiency long life LED package modules on MCPCB with LED lumen efficacy of >140 lumen per watt, electronic driver powered by built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open / short circuit protection, phase to |
| 134 | phase protection, over voltage protection, 10 kV surge protection, surge voltage protection & other safety tests as per IS:15885 Part-2/Sec13 completed to driver with superior finish with top maintainable driver compartment complete with the fittings with two pairs of necessary nuts and bolts with washers with suitable packing (GI pipe light grade 32/40 mm bore) arrangement to fixing with wall / bracket complete all as specified and directed. |
| 135 | S&F, recessed mounting LEDluminaire having power consumption not more than 80W and light output not less than 10000 lumens with system efficacy > 125 lumen/Watt. Luminaire housing shall made of corrosion proof LM6 grade pressure die cast aluminum body with integrated PC lens cover with IP-65, IK-07 protection. The luminaire should be having minimum 50000 burning hours (L70B50) with CRI ≥ 70 and co-related color temperature (CCT) of 5700K. |
| 136 | The luminaire should have 4KV surge protection integrated in driver with 90% driver efficiency, PF ≥ 0.95 and operating voltage range 120-270V high voltage cutoff @ 325 ± 15V with auto restart feature and total harmonic distortion THD ≤ 10%. The luminaire and driver shall be separately BIS approved of same make equivalent to Philips / Osram / Lighting Technologies. LM80, LM79, type test certificate and BIS certificate need to be submitted. |
| 137 | S&F, 6 watt (2 way) wall lights suitable for wall decorative items having aluminium housing / body material, efficacy (lm/W): 70lm/W, Silica Lens glass type, 45 degree beam angle of LED 75 & product outer dimension: 175 x 41 complete all as specified and directed. |
| 138 | Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetics enamel paint of approved brand and manufacture to give shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required complete all as specified and directed. |
| 139 | Numbering of ceiling fan / exhaust fan / wall mount fan with suitable enamel paint as required complete all as specified and directed. |
| 140 | S&F, electronic ceiling fan regulator, modular type 2 module stepped type heavy duty suitable to work on 230 volts complete all as specified and directed. |
| 141 | Taking down carefully exhaust fans of sweep 300/450 mm from any height and of any make and sweep including disconnecting the cable from ceiling rose and shifting to store for servicing and removing the old painting and providing new painting to exhaust fans complete with synthetic enamel Grey paint by spraying using machine including filling cavities with filler one coat after cleaning all dust and refixing the same in original position including necessary electrical connection making the surface in good finishes complete all as specified and directed. |
| 142 | Taking down carefully wall mounted fan from any height and of any make / any sweep including disconnecting the cable from ceiling rose and shifting to store carry out servicing, greasing, oiling and painting of wall mounted fan complete apply two coats of synthetic enamel paint by spray painting using necessary machine including filling the cavities with filler one coat after cleaning all dust and refixing the same after servicing / repair including replacement of necessary nut bolts as specified and directed.Note: Rewinding of burnt motor with copper wire will be measured and paid separately under respective items of Schedule. |
| 143 | M&L for carry out rewinding of wall mount fan motor of any size, dismantling wall mount fan, removing of old burnt winding, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size / gauge including class \"B\" insulation, varnishing heating etc., changing the fan capacitor with suitable size compatible with the existing model, reassembling and testing, refixing the same in original position complete all as specified and directed. |
| 144 | S&F, air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed. |
| 145 | Supply, installation, testing & commissioning of 1200 mm sweep BEE 5 Star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation : B, 03 Nos. blades, 30 cm long down rod, 02 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 210 Cum/Min, 350 RPM (tolerance as per IS:374-2019). THD less 10% remote or electronic regulator units for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rises = 75 degree C (max), insulation resistance more than 2 mega ohms suitable for 230V Hz, single phase AC supply, earthing etc., complete all as specified and directed. |
| 146 | S&F, exhaust fan 230 Volt 50 Hz single phase AC supply, 300 mm sweep with louver complete withmetal body powder coated with protective steel bird guard on wall includingprovision of 3 core 1.0 Sq mm cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor complete all as specified and directed. |
| 147 | Taking down old unserviceable TPN DB any type and size and S&F, vertical TPN DB for MCCB incomer, metal double door, 415 V, three phase 4 way ready to use DBs provided with neutral bar, mechanical impact strength IK-09, insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for MCCB\"s upto 125 Amps as I/C (Frame 1) and MCBs (TP/SP) as outgoing, IP 43 protection, module Optium F2 + 4 + 4 + 4, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed. |
| 148 | Taking down old unserviceable MCB DB any type and size and S&F, MCB distribution board horizontal type, three pole and neutral 6 way double door sheet steel, 415 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, din bar, interconnections, powder painted including earthing etc., as required complete all as specified and directed. |
| 149 | Taking down old unserviceable MCB DB any type and size and S&F, MCB distribution board horizontal type, three pole and neutral 4 way double door sheet steel, 415 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, din bar, interconnections, powder painted including earthing etc., as required complete all as specified and directed. |
| 150 | Providing and fixing 100 A and breaking capacity 30 KA, four poleMCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panels, making connections etc., as required complete all as specified and directed. |
| 151 | S&F, 63 Amps triple pole & neutral rating, 240/415V, 10KA \"C\" curve, miniature circuit breaker suitable for inductive load of triple pole and neutral in the existing MCB DB complete with connections, testing & commissioning etc., as required complete all as specified and directed. |
| 152 | S&F, 63 Amps triple pole rating, 240/415V, 10KA \"C\" curve, miniature circuit breaker suitable for inductive load of triple pole and neutral in the existing MCB DB complete with connections, testing & commissioning etc., as required complete all as specified and directed. |
| 153 | S&F, 5 A to 32 A single pole rating, 240/415V, 10KA \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing & commissioning etc., as required complete all as specified and directed. |
| 154 | Wiring for circuit / submain wiring alongwith earth wire with the size of 2 x 6 sq.mm + 2 x 6 sq.mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required (for VTPN to DB TPN) complete all as specified and directed. |
| 155 | M&L for earthing complete with G.I earth plate 600mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long with charcoal / coke and salt as required complete all as specified and directed. |
| 156 | M&L for KWH meter board only made of sheet metal board made from 2 mm thick CRCA sheet with door having locking arrangement with keys and duly powder coated suitable for provision of KWH meter three phase - 01 No for community hall including cutting chasing in wall and fixing and making good as per existing surface complete including removing old box complete all as specified and directed. Note: (i) The cost is for only fabricating and fixing at site.(ii) Refixing of old electric meter is included in quoted rate including minor repairs if required.(iii) Labour cost of electrician / helper / fitter included with connection of wires. |
| 157 | M&L for wiring for circuit alongwith earth wire with the size of wire 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 158 | S&F of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modular socket, connection etc., as required atsite complete all as specified and directed (for 16/15 power plug / socket). |
| 159 | Supply, installation, testing & commissioning of Networkable 2 Loops microprocessor based 2 wire fault tolerant loop with optional redundant network module, each loop shall have the capability of connecting 126 devices. The fire alarm control panel shall have built in degrade mode function. The panel should have inbuilt TCP/IP communication for panel program and remote monitoring option through LAN or WAN communication. The panel shall be able to give location of all fire and more fire / fault and isolation conditions of addressable units via. the address codes. |
| 160 | The panel shall have the capacity of storing upto 2000 events. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common alarm, fault and monitored sounder output. The panel shall have a 8 x 40 characters LCD display with resolution of 256 x 112 pixels and analog output, external / inbuilt printer to log all fire or fault events complete in all respects. The panel should have protection category of IP-30. Also the panel should have the option to operate in manned and unmanned mode. |
| 161 | The panel shall have a built in power supply and battery charger alongwithmaintenance free 12 AH, 2 x 12 volts SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and as per specifications and duly approved by UL/FM. |
| 162 | Supply, installation, testing & commissioning of intelligent addressable manual call point suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP-44 and extra acceesories as required, duly approved by UL/FM. |
| 163 | Supply, installation, testing & commissioning of intelligent addressable loop powered / external powered sounder cum beacon with base, able to provide an output of 99dBA at 1m, peak light output of at least 3.2cd and shall have 11 programmable tones, 3 volume settings selectable from the panel and fully synchronized with other sounders and shall have the ability to switch between one tone for alert and one tone for evacuation shall have protection category of IP-42 and duly approved by UL/FM. |
| 164 | Supply, installation, connection, testing & commissioning of intelligent analog addressable photoelectric type smoke detector and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air currents. Detector should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP-40 and duly approved by EN54/LPCB/VDS/FM. |
| 165 | Supply, installation, testing & commissioning of intelligent analog addressable beam detector having the coverage distance ranging from 5-100m. The transmitter and receiver shall be combined in a single housing. Detector shall communicate 3 danger levels for differentiated alarm activation. Detector should have the protection category of IP66 and duly approved byUL/FM. |
| 166 | Supply, laying, testing & commissioning of 3 core x 1.5 Sq.mm cable, armoured screened FRLS twin twisted PVC insulated copper cable ISI alongwith all accessories required for complete installation, making terminations etc., where required complete all as specified and directed. |
| 167 | Supply, installation, testing & commissioning of addressable input module with inbuilt isolator and shall have the LED indication for normal, fault, test & activation. The module shall have the option for configuration as fail safe operation and duly approved by UL/FM. |
| 168 | Supply, installation, testing & commissioning of analog addressable type active loop repeater (loop power / external power) fire terminal, Backlite LCD display 6 x 40 characters display having controls for reset, mute, accept, silence alarms and self test with programmable free keys and duly approved by UL/FM. |
| 169 | M&L for sub main wiring with 2 runs single core 4 Sqmm PVC insulated unsheathed multistranded, FRLScopper conductor cable in recessed / surface medium class PVC conduit and its accessories and connecting terminals to DBs / switch board including providing 1 run of 4 sqmm PVC insulated unsheathed multi stranded FRLS copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. |
| 170 | S&F, 20A 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosure plug top alongwith 20A \"C\" curve SP, MCB in sheet steel enclosure on surface or in recess with chained metal cover for socket outlet and complete with connections, testing & commissioning etc., as required complete all as specified and directed. |
| 171 | S&F, voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed. |
| 172 | S&F, water cooler fully stainless steelelectric driven (single phase), having approx storage capacity of 120 litres and nominal cooling capacity of 60 litres per hour complete all as specified and directed. |
| 173 | Supply, installation, testing & commissioning of VRV/VRF TOP discharge 20 HP VRV X TOP DISCHARGE TYPE OUTDOOR Unit - suitable to operate at 48°C ambient temperature comprising of variable hermetic inverter compressors, (full inverter compressor / multiple compressors per module) matching air cooled condenser with copper tubes and aluminium fins duly covered by anti-corrosion and hydrophilic resin film. |
| 174 | Combination of inverter hermetic scroll compressors suitable for operation on R-410A, complete with high / low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, protective devices for electrical and electronics components, fusible plugs, fuses, cabling etc., and suitable for operation on 360V~415V~3Ph~50Hz A.C. supply. |
| 175 | Supply, erection, testing & commissioning of VRV/VRF X indoor units 1 TR Hi wall type IDU, complete with low-noise centrifugal fan, cooling coil, filter, insulated drain pan, protective devices for electrical and electronic components and electronic expansion valve with wireless remote control unit standby sequential basis complete all as specified and directed. |
| 176 | All as per Sl item No 154 here-in-before but 2 TR Hi wall type IDU with wireless remote. |
| 177 | All as per Sl item No 154 here-in-before but 4 TR round flow cassette type IDU with wireless remote. |
| 178 | All as per Sl item No 154 here-in-before but 8.5 TR High Static Ducted IDU wired remote. |
| 179 | Supply & install, REFNET Header / Branches / Panel (Y/T) joints for indoor units & outdoor unit suitable for refrigerant pipe of any sizes as per manufactures recommendation complete all as specified and directed. |
| 180 | Supply, installation & testing of hard drawn copper refrigerant piping with insulation (suction copper pipe) with suitable size thick class \"O\" nitrile rubber, UV treatment (coating) for exposed refrigerant piping insulation complete all as required at site as per specifications complete all as specified and directed. |
| 181 | Supply, installation & testing of hard drawn copper refrigerant piping with insulation (discharge copper pipe) with suitable size thick class \"O\" nitrile rubber, UV treatment (coating) for exposed refrigerant piping insulation complete all as required at site as per specifications complete all as specified and directed. |
| 182 | Supply, laying, connecting & testing flexible PVC insulated multistranded 1100 V grade copper conductor unarmoured cable of size 1.5 sq mm 2 core including electrical grade PVC conduit 20 mm (for communication between IDU to IDU and outdoor unit) complete all as specified and directed. |
| 183 | Supply, install, test & commissioning of CPVC drain pipe of suitable size connecting the drain lines from the indoor units connected to nearest drain at ground level through PVC pipe with U-trap, 9mm thick round nitrile rubber insulation supported on suitable clamps / supports etc., including chasing, drilling, concealing and making good the same on walls etc., complete all as specified and directed. |
| 184 | Supply, fill & charge Refrigerant Gas R410a during commissioning in addition to default gas in the compressor including vacuum complete all as specified and directed. |
| 185 | Supply, fabrication, installation & balancing of GSS supply rectangular ducting 24g complete with all fittings such as Reducers, Tee bends, Takeoffs, Suspension, Hi-Tech supporting for plenum, ducts etc., complete as required for the air conditioning application. |
| 186 | Supply, fabrication, installation & balancing of GSS supply rectangular ducting 22g complete with all fittings such as Reducers, Tee bends, Takeoffs, Suspension, Hi-Tech supporting for plenum, ducts etc., complete as required for the air conditioning application. |
| 187 | Supply, installing & testing of acoustic insulation of ducts with nitrile rubber and sound proof sheets closed cell elastomeric foam insulation. |
| 188 | Supply, installing & testing of thermal insulation of ducts with nitrile rubber. |
| 189 | Supply, installing & testing of acoustic insulation of ducts with nitrile rubber and sound proof sheets closed cell elastomeric foam insulation. |
| 190 | Canvas connection of fire retardant quality for connecting indoor unit to ducting / plenum for Mid Static ductables. |
| 191 | M&L for sub main wiring with 2 runs single core 4 Sqmm PVC insulated unsheathed multistranded, FRLS copper conductor cable in recessed / surface medium class PVC conduit and its accessories and connecting terminals to DBs / switch board including providing 1 run of 4 sqmm PVC insulated unsheathed multi stranded FRLS copper cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 192 | Supply, installing, testing & commissioning, factory made and tested LT panel board, outdoor type, platform mounted suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 400Amps rating [03(P)+01(N)] installed on porcelain insulators. The panel shall be dust and vermin proof, IP-56 class protection and made of 3.15 mm CRCA / MS sheet and 50 x 50 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type with aprons for cable entry and fixing 02 Nos. danger notice plate of size 20 x 15cm with letter, figures and |
| 193 | conventional skull bones in signal red colour and fixed front & back door LT panel etc., with voltage and danger indicated in Hindi & English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is as per site requirement including connections of all outgoing / incoming existing cables of size by drawing / digging out cable from loops in trenches / ducts outside the building inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size |
| 194 | aluminium lugs for terminal connections of cables, necessary PCC foundation / brick with plastering to the cable duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint complete all as specified and directed Engineer-in-Charge. The scope of work includes the following items:Note: LT panel board should be as per IS/ICE 61439-Part-I & II type test certificates panel builder should submit all certificates before executing the job. |
| 195 | (I) Incoming:(i) MCCB 250 Amps, 4 pole, Breaking capacity 25KA, 415V, 50Hz, AC supply, microprocessor based release for over current, short circuit and earth fault - 01 No. alongwith spreader terminals.(ii) Ammeter Digital type, CT operated 0-400A range - 01 Set (with selector switch and CT).(iii) Volt Meter Digital type 0-500 V range - 01 No (with selector switch).(iv) Indicating lamp LED type 240 V 50 HZ AC supply set of three colour (RYB) - 01 set. |
| 196 | (II) Outgoing:(i) MCCB 40 Amps, 4 pole, Breaking capacity 25KA, 415V, 50Hz, AC supply, microprocessor based release for over current, short circuit and earth fault - 04 Nos alongwith spreader terminals.(ii) Ammeter digital type, CT operated 0-400A range - 04 sets (with selector switch and CT).(iii) Volt meter digital type 0-500 V range - 04 Nos (with selector switch).(iv) Indication lamp LED type 240 V 50 HZ AC supply one set of twocolour (Red & Green for ON/OFF indication of MCCB) - 04 sets. |
| 197 | M&L for plate earthing for sub station equipments complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 1.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 2.25 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of |
| 198 | equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20 mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate excavation & earth work and cover complete all specified all as specified and directed. |
| 199 | Providing and fixing 25 mm x 5 mm G.I strip on surface or in recess for connection as required complete all as specified and directed. |
| 200 | Supply, installing, testing & commissioning of LT indoor type factory made LT panel for extending the existing LT panel board at LT substation (near multipurpose hall) with 2.0 mm thick CRCA sheet factory made indoor type totally enclosed weather dust and vermin proof as per IS, CPRI approved with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 350 Amps suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system with necessary supporting insulators so as to match with the existing LT panel board / distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of |
| 201 | existing panel / bus bar including necessary supporting frame / channel fix through existing cable trench from ground with comprising of the following: -(a) MCCB 250 Amps, 36KA, Ics-100% of Icu (SC/OC/EF) - 01 No.(b) Provision for outgoing cable of size upto 185 sq mm from the extended portion of LT distribution panel. |
| 202 | Supply, installing, testing & commissioning, factory made and tested LT panel (KIOSK) 100mm x 900 x 500mm size indoor type, platform mounted suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminum bus bars 400Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2mm CRCA sheet and 40 x 40 x 4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & back opening type with aprons for cable entry and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white of size 20 x 15cm with |
| 203 | letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc., with voltage and danger indicated in Hindi & English with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 15 cm above the ground level complete all as specified and directed including connections of all outgoing / incoming existing cables by drawing / digging out cable from loops in trenches out side the building inclusive of necessary excavation and earth work |
| 204 | as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, necessary brick foundation with plastering to the panel board, all outgoing feeders shall be connected by cable through suitable size gland plate / glands and the various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and complete all as specified and as directed Engineer-in-Charge. The scope of work includes the following: -(I) Incoming:(i) MCCB 4 Pole, 250A, microprocessor based breaking capacity 36 KA, 415 V, 50 Hz with EF, OL, SC, protection - 01 No alongwith spreader terminals. |
| 205 | (ii) Digital voltmeter 0-500 volts with selector switch - 01 No.(iii) Digital Amp meter 0-300 Amps with selector switch & CT - 01 No.(II) Outgoing:(i) MCCB 4 pole, 125 Amps, microprocessor based breaking capacity 25 KA, 415 V, 50 Hz with EF, OL, SC, protection - 03 Nos alongwith spreader terminals.(ii) MCB TPN 32 Amps \"C\" curve - 01 No. |
| 206 | S&F, 29 watt new generation contemporary designer, Post top Lantern with cable 0.45 m without plug having housing material aluminum die cast, energy saving, environmental friendly, long life aesthetically designed with symmetric light distribution, mounting device Post-top for diameter 60 mm and limited upward light component with higher power LEDs with IP-65 degree protection, individual LEDs must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 86.21 lm/W, (minimum lumen output of luminarie should be 2,500 lumen), Color rendering index (CRI) 70 and Correlated Color Temperature (Nom) 4000 K, the luminarie should have Surge Protection |
| 207 | (common / differential) 4/2 kV, Luminous flux tolerance + 10, Power Factor (Fraction) 0.9, input Voltage 220 to 240, should be provided complete all as specified and directed by Engineer-in-Charge. |
| 208 | Supply, excavation, jointing & lay pipe galvanized, “heavy class”, including fittings, 60 mm dia for mounting Post-top lantern light with height upto 1.5 - 4 RM including PCC 1:4:8 protection with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade for Post Lantern lights complete all as specified and directed by Engineer-in-Charge. |
| 209 | Supply, laying & testing, PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade (for Post top Lantern lights from proposed from junction box) complete all as specified and directed. |
| 210 | S&F, replacement of transparent cover outside type junction box for Post Lantern lights for garden lightingof size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 04 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (dust and power jet proof according to IEC 60529), shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II) made of halogen and silica free recyclable material, UV resistant |
| 211 | having high grade gasket made of polyurethane with copper bus bar 25 x 5 mm - 04 strip, 01 No. MCB SP 6 Amps with locking arrangement and 02 Nos M-40 size cable gland and one M-32 size gland suitable upto 10 Sqmm cable and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt etc., complete all as specified and directed. |
| 212 | Supply, laying, jointing, testing & commissioning LT underground cables, 10 Sqmm 3 core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed.Note: Rate quoted includes terminal lugs / road cutting / wall cutting / floor cutting and making good damaged portion matching with existing surface with all existing finishes. |
| 213 | Supply, laying, jointing, testing & commissioning LT underground cables, 25 Sqmm 4 core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. |
| 214 | Supply, laying, jointing, testing & commissioning LT underground cables, 120 Sqmm 3.5 core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. |
| 215 | Supply, laying, jointing, testing & commissioning LT underground cables, 185 Sqmm 3.5 core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. |
| 216 | Excavation in trenches not exceeding 1.5 mtr deep and 1.5 mtr width as in hard / dense soil complete all as specified and directed.Note: NO JCB excavation is permitted for earth work. |
| 217 | Returning filling including leveling watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed. |
| 218 | Removal of surface soil to a distance not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 219 | M&L for river washed and screened, dry sand for filling in trenches below 8 cm laid before laying of cable and 15 cm sand cable laid after laying the cable andaround underground cables for cushioning of cables complete all as specified and directed. |
| 220 | M&L for laying old size bricks, common burnt clay building bricks sub class \"B\" designation 75 complete all as specified and directed. |
| 221 | M&L for road cutting / removing the hard standing / cutting floor inside the substation / E/M installations / path for laying of cables of any size complete all as specified and directed. |
| 222 | M&L for PCC 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) complete as in foundations mass concrete, fillings complete all as specified and directed. |
| 223 | Supply & laying, galvanised steel tubing, 50 mm bore, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles / walls (with required size flat iron clamp bolts, nuts & washers) pipes complete all as specified and directed. |
| 224 | S&F in repairs earth continuity conductor or main earthing lead of galvanised iron strip of size 25 x 5 mm, fixed on wall / inside the cable trench with supporting insulator fixed on wall / trench from existing earth test point complete all as specified and directed. |
| 225 | Earth work in excavation by mechanical means (hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m all kind of soils complete all as specified and directed. |
| 226 | Dismantling of old S.W pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps complete all as specified and directed. |
| 227 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W pipes including bed concrete as per standard design : 150 mm diameter RCC pipe complete all as specified and directed. |
| 228 | Providing and laying non-pressure NP2 class (light duty) RCC pipes 150 mm dia with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints complete all as specified and directed. |
| 229 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement mortar 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain complete all as specified and directed. |
| 230 | Dismantling of manhole including RCC top slab, CI cover with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-Charge : rectangular manhole 90 x 80 cm and 45 cm deep complete all as specified and directed. |
| 231 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : inside size 90 x 80 cm and 45 cm deep including CI cover with frame |
| 232 | (light duty) 455 x 610 mm internal dimensions, total weight of cover and frame to be not less than 38 kgs (weight of cover 23 kgs and weight of frame 15 kgs) : with common burnt clay with sewer bricks conforming to IS complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail