| 1 | Supply of 1 Loop Analogue Addressable Fire Alarm Control Panel expandable upto 2 Loop, loop current 500 mA maximum per loop, dual flash based microprocessor, supports to connect 240 addressable devices one each loop via fully digital communication protocol, equipped with a white backlit display (240x64 pixel resolution) graphical LCD Display with at least 6 lines of information, 200 fire zones (soft zones), fully programmable via alphanumeric keypad or configuration software, dedicated USB and RS-232 serial port for direct or PC connection. 5500 events storage, loop current 500 mA, panel shall be equipped with in-built multi-meter for live monitoring of loop current, earth voltage, loop voltage etc., installer\"s logo application, can be networked to compatible addressable panels and repeater panels by adding a network card, features battery charger status and temperature, supports programmable cause/effect on outputs, panel housing meets IP30 ingress protection classification |
| 2 | Supply of Intelligent Analogue Optical Smoke Detector with advanced optical chamber and smoke inlet design to provide resistance to entry of dust to provide immunity to false alarms, programmable multiple smoke sensitivity level setting, bi-directional in built short circuit isolator to protect against cable faults, dual bi-colour LED\"s with 360° view of status, auto-addressable/electronically addressed, utilizes fully digital communication addressable protocol with high noise rejection. Approval by LPCB for EN-54-7 & EN 54-17 standard |
| 3 | Supply of Intelligent Analogue Class-P Heat Detector with two thermal sensitivity level, the two level corresponds to rate-of-rise (ROR) A1R Class (most sensitive) and Class BS (least sensitive), thermal alarm threshold for ROR AIR Class 58°C and BS Class 78°C, bi-directional in-built short circuit isolator to protect against cable faults, dual bi-colour LED\"s with 360° view of status, auto addressable/electronically addressed, utilizes fully digital communication addressable protocol with high noise rejection. Approved by LPCB for EN 54-5 & EN 54-17 standard |
| 4 | Supply of Standard Detector Base for mounting the compatible addressable detector |
| 5 | Supply of Wireless intelligent Single Channel Input Module for monitoring of third party equipment/external devices switched NO/NC status and transmitting the status Signal control panel through translator/ expander modules, input circuit is fully monitored, 7 operating frequency channels for bi-directional wireless communication with compatible translator/expander module, operating wireless frequency 865 MHz, maximum radiated power 5 dBm (3mW), communication range of max 200 meter in open space, two bi-colour (Red/Green) LED\"s provided for functional and battery level status indication, provided with dual lithium batteries (primary and secondary power source). IP 65 Rated Approved by LPCB for EN 54-18, and EN 54-25 standard |
| 6 | Supply of Intelligent Sounder Interface Module allows to connect conventional Sounder or Sounder Beacon to addressable loop, with in-built short circuit isolator, allows for two stage alarm capability, addressed through auto and manual options. Approved by LPCB for EN 54-17 & EN 54-18 standard, |
| 7 | Supply of Conventional Wall Sounder with Beacon for providing Audible and Visual Alarms in response to the output signal from the control panel, 32 selectable tone and adjustable sound level, maximum output volume @ 1M distance 100 dB(A), output tone frequency range 440 Hz to 2900 Hz, Visual alarm device output frequency 0.5 Hz, Approved by LPCB for EN 54-3 standard |
| 8 | Supply of Wireless Intelligent Photo-Electric (Optical) Smoke Detector with advanced dual path optical chamber design, optimized performance utilizing internal algorithm, programmable three sensitivity levels/settings (High, Normal, and Low), 7 operating frequency channels for bi-directional wireless communication with compatible translator/expander module, operating wireless frequency 865 MHz, maximum radiated power 14 dBm (25mW), communication range of max. 200 meter in open space, two tri-colour (Red/Amber/Green) LED\"s provided for functional and battery level status indication, support magnet test or aerosol based tester, dual trap/filter to prevent entry if insects and dust particles, provided with dual lithium batteries (primary and secondary power source). Approved by LPCB for EN 54-7 and EN 54-25 standard |
| 9 | Supply of Wireless Heat (Thermal) Detector with heat/thermal sensor for optimized and far performance utilizing internal algorithm, thermal sensor alarm temperature 58 C class A1RROR) or 78 C (Class BS High Temperature), programmable multiple activity level, 7operating frequency channels for bi-directional wireless communication with compatible translator/expander module, operating wireless frequency 865MHz, maximum radiated power14 dBm (25mW), communication range max 200 meter in open space, two tri-colour (Red/Amber/Green) LED\"s provided for functional and battery level status indication, support magnet test or aerosol based dual trap/filter to prevent entry of insects and dust particles, provided with dual lithium batteries (primary and secondary power source). Approved by LPCB EN 54-5, EN 54-25 standard |
| 10 | Supply of Translator module, shall allow addressable loop communication to 32 field devices, system devices can be configured through translator module or loop powered, two orthogonal antennas for safe and reliable wireless communication, shall have high wireless transmission range with wireless field devices of max 150 meter in open space, maximum radiated power 5dBm (3mW), enabled with ating frequency channels for bi-directional wireless communication, operating frequency range 865MHz, IP 65 rated. Approved by LPCB for EN 54-18 and EN 54-25 standard |
| 11 | Supply of Wireless Expander module to enhance/boost wireless communication range of the Translator module, enables communication between 32 wireless field devices and translator module, system devices can be configured through translator module or software, powered through auxiliary power supply, two orthogonal antennas for safe and reliable wireless communication, shall have high wireless transmission range with wireless field devices of max. 150 meter in open space, maximum radiated power 5dBm (3mW), enabled with 7 operating frequency channels for bidirectional wireless communication, operating frequency range 865MHz, IP 65 rated. Approved by LPCB for EN 54-18 and EN 54-25 standard |
| 12 | Suppy of Single Loop Driver Card designed for use with compatible analogue addressable panels, provides control and connection/communication to maximum 240 addessable device per loop |
| 13 | Supply of Intelligent Analogue Manual Call Point with resettable operating element,with in-built bidirectional short circuit isolator. Bi-colour LED for local indication of device status, single action operation, reset to normal condition using special reset key, clearly visible alarm flag in the activated state. Approved by LCPB for EN 54-11 standard. |
| 14 | Supply of 24V DC 3A Switching mode power supply unit with PWM controller and MOSFET based design. Input voltage 180-265V AC, frequency 45-60 Hz, provided with transient surge protection (Varistor) |
| 15 | Supply of Mounting Accessories like back box for detectors, devices & cable glands, etc. |
| 16 | Fireray One infrared beam smoke detector 50M range comprising provided with 1 Reflective prism. UL listed |
| 17 | Long Range Kit 3 additional reflectors to extend Fireray One range to 120m. UL listed |
| 18 | Supply of 2C x 1.5 Sq.mm PVC insulated copper conductor armoured cable |
| 19 | Wall mounted automatic Fire extinguisher using two heat sensing quartzoid bulb with valves for detection & extinguishing of fires, Wall Mounted Automatic Fire Extinguisher Powder Based (as per IS 4308) Automatic, Mild Steel, Hose Length 500 millimeter, Quartzoid bulbs temperature rating 68 degree Celsius, Pressure Testing-PED Certificate/CE Marking to PED 2014/68/EU, Annexure 3 (Module H) from EU Notified Body. Capacity 6 KG ABC Automatic Wall Mounted Fire extinguisher |
| 20 | Stored Pressure Water Mist Based Bs En Standard Based Portable Fire Extinguishers, Conformity to Standard EN 3-7+ A1: 2007 & EN 3-8:2006 with latest amendment, Weight of Filled Portable Fire Extinguisher (kg)10.438, Suitable for Class -A fire ratings as per EN 3-7 13A, Fire Rating for Class -F 75F, Operating Temperature (-30° C< N >=60\"C), Warranty for the Complete Product 5 year, Operating Temperature (+5° C to +60° C), Service Pressure 15 bar, Burst Pressure 112 bar, Minimum Discharge Time (seconds) required as per EN Standard12 second, Shelf Life (Life Cycle) of the Fire Extinguisher 10 Years, Marine Equipment Directive (MED) Approved CE Certification from EU Notified body CF Identification Number of the Notified body (Must Declare) CE 1128 of Test Report from Central Govt./NABL/ILAC accredited lab to prove to conformity to specification Test Report No 1329b, Issue:04, Test Report Date Name of the Lab BRE Global Ltd. Stored Pressure Water Mist Based Fire extinguisher 6 litre Capacity |
| 21 | High Pressure Water Mist & CAFS, Capacity 50 Litre. trolley, (As per EN 1866 1:2007-08) working Pressure 31 Bar, Air Bottle Capacity 6 Litre 300 Bar Pressure, Approved By PESO Petroleum and explosive safety organization), Fire extinction suitability with standard AFFF 6% confirming to IS 4989 or UL 162 standards Class - A Fires, Class - B Fires, Polar Solvent Fires, Live Electrical fires 1000 V as peR EN 3-7:2004+A1:2007/ Tested for 35 KV Certification from NABL accredited Lab and any Central Govt. Lab. (tested in Indian condition) as per EN 1866-1:2007-08. Test report shall be enclosed along with the offer, The product should be PED certified to PED 2014/68/EU, ANNEX III (MODULE H) the supplier should have a license from PESO for refilling & storage of high pressure gas cylinders. Water Mist & CAF High Pressure 50 Litre. Trolley Please Enable Macros to View BoQ information |