| Sl. No. | Item Description |
| 1 | Surface excavation in any type of soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed. |
| 2 | Excavation over areas, n exc 1.5 m deep and getting out for foundation in any type of soil and getting out complete all as specified and directed. |
| 3 | M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in benching, water troughs and the like including necessary form work, complete all as specified & directed. |
| 5 | M&L PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in wall of surface channel and drain, complete all as specified & directed. |
| 6 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl forms, moulds etc. complete all as specified and directed. |
| 7 | M&L Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8type D-2 using 40mm graded stone aggregate, and tested,for 100mm dia bore pipes allas per SSR Part-I specifications, complete all as specified and directed. |
| 8 | M&L Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed. |
| 9 | S&F 150mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer\"s instructions and as directed. (Bedding/Haunching and earthwork paid separately under respective items of schedule) |
| 10 | M&L Cutting salt-glazed stoneware drain pipe in position new drains (internal dia of pipe 100mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 11 | M&L RCC M-25 (design mix) as in foundation ,including rafts, footing foundation beams, plinth beams for columns. etccomplete all as specified and directed. |
| 12 | M&L RCC M-25 (design mix) as Chajjas and similer work complete all as specified and as directed. |
| 13 | M&L RCC M-25 (design mix) as Columns,pillars, piers,posts and struts and similer work complete all as specified and as directed. |
| 14 | M&L RCC M-25 (Design mix) in Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and directed. |
| 15 | M&L RCC M-25 (Designe mix) inRoof slab, shelves, landing slabsupported on wall/column and the like etc complete as required complete all as specified and directed. |
| 16 | M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, all as specified and as directed. |
| 17 | Returning & filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 18 | Removal of excavated material N.exc 50 mtr and depositing where directed at level not exc 1.5 m from starting point complete all as specified. |
| 19 | M&L Formwork to sides of concrete foundation, footings bases of columns, raft and raft beams, plinth beams and similae work vertical or to batter complete with Rough finishedflat surfaces complete all as specified. |
| 20 | M&L Form work to side pillars, post, strust, pier, columns and similar works squar or rectangular roughfinishedflat surfaces to concrete. Complete all as specified and directed. |
| 21 | M&L Form work to sides andsoffits of floor or roof beams , haunchings, girders , bressummers, lintels, cantilevers, shelves including sup- posts, overhangs, etc. also splays between floors and beams, etc including rough finished to concrete surfaces complete all as specified and directed. |
| 22 | M&L Form work to chajjas, chullah hoods, troughs and similar works incl edges etccomplete all as specified and directed. |
| 23 | M&L Form work to soffit of suspended slab such as roof slab not exc 20 0 mm thick horizontal or slopinf flate including fair finished to concrete surfaces. |
| 24 | M&L TMT bar 10 mm dia and over , cut to length, bend to as required including cranking, bending an binding with annealed wire not less than 0.9 mm dia complete all as specified and directed. |
| 25 | M&L TMT steel bars5 mm dia and overupto and including 10 mm dia in stirrups, spacers and binders in reinforcement, cut to length, bend to as required including cranking, bending an binding with annealed wire not less than 0.9 mm dia complete all as specified and directed. |
| 26 | M&L Rendering 15 mm thickonfair faces of brick/concrete surfaces in cement plaster 1:4, by using liquid water proofing compound finished even and smooth without using extra cement, complete, all as specified and as directed. (WPC measured and paid separately) |
| 27 | M&L Rendering 10 mm thick on internal surfaces of in cm 1:6, finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L rendering 5 mm thick in cm 1:3 on ceiling/soffit, finished even and smooth without sing extra cement complete all as specified and directed. |
| 29 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 30 | M&L for capilary rise treatment of walls as following :-Base coat: Berger HS Latex plus (or equivalent)Consumption base coat: 0.3 kg/m2Second and Third coat: Latex sheild 2K (or equivalent)Consumption top coat: 3 kg/m2System requirements: density: 2.00 kg/ltrCompressive strength: 0.5 N/mm2 Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"EF\" on page no. 103of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 31 | M&L Hard core of gauge n.exc. 63 mm, deosited spread and levelled in layers n.exc. 15 cm thickusing broken stone or boulders, watered and rammed to a true surfaces complete all as specified and directed. |
| 32 | M&L PCC 1:4:8 type D2, 75 mm thick , using 40 mm graded stone aggregate s in sub base of floor complete all as specified and directed. |
| 33 | M&L 75 mm thick PCC1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in plinth protectionfinished even and smooth without using extra cementcomplete all as specified and directed. |
| 34 | M&L PCC 1:3:6 type C2, 75 mm thick , using 40 mm graded stone aggregate s in sub base of floor complete all as specified and directed. |
| 35 | M&L Vitrified coloured tiles, light shadeof size 600mm x 600mm x 9 to 10 mm thick, asin floors etc bedded & jointed in neat cement slurry over and including15 mm thick screed bedincement mortar 1:4 and pointed inwhite or coloured cement to match the colour of tiles, completeall as specified and directed. |
| 36 | M&L Vitrified coloured tiles, light shade 600mm x 600mm x 9 to 10mm thick,on vertical surfacessuch as skirting / dado etc bedded & jointed in neat cement slurry over and including 10mm thick backing coat of cement mortar 1:4 and pointed in white or coloured cement to match the colour of tiles,complete all asspecified and directed. |
| 37 | M&L Non skid ceramic coloured tile 400 x 400 x 7mm thick as in floors set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and as directed. |
| 38 | M&L Glazed ceramic coloured tiles 450 x 300 x 7mm thick as in vertical surfaces over and including 10mm thickbacking layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the tile colour, shade, pattern & laying of tiles etc. shall be all as specified and as directed. |
| 39 | S & F Granite 18-20 mm thick (of any type) work (table rubbed and polished) in steps, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade complete all as specified and directed. |
| 40 | M&L Aluminium anodised powder coated frame for door, window, ventilator with one or more rebates including joints clite for fixing etc complete all as specified. (Minium thickness of power coating 50 micron) complete all as specified and directed. |
| 41 | M&L Aluminium anodised powder coated door/window/ventilator shutter, sliding type/ hung type, made out of aluminium sheet/section (section- 20620 & 20847) including necessary jointing cleats, glazing clips, rubber packing, suitable handle 1 No\"s in each shutter, tower bolt, hinges 110mm long, anodised aluminium snap beading screws, complete all as specified and directed.Note : Sheet glass to be fitted will be measured and paid separately. |
| 42 | M&L Anodised aluminium power coated (minimum thickness 50 micron) designer grill of 5-6mm dia of mesh size 50X50mm centre to centre with 25mm flat as per sample kept in GEs office including aluminium beading complete all as specified and directed. |
| 43 | M&L Sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or wooden beads, in square n exc. 0.5 Sq m each pane, complete all as specified and directed. |
| 44 | M&L 5 mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square n.exc 0.5 sqm each complete all as specified and directed. |
| 45 | M&L for plain 10-12 mm thick toughened glass side hung door/partition with stainless steel handle (25mmx300mm)02 Nos for each shutter, floor spring hinges 04 nos and necessay joining cleats, beadings or frame and fittings of stainless steel as specified and directed. |
| 46 | S &F Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelaminated sheet & edges will be painted to match with prelam sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed. |
| 47 | Supply and fixingin frame with suitable size and 3 Nos of butt hinges Factory made solid PVC moulded door shutter, 28 to 30mm thick (style) with 2, 4, or 6 raised panel design with 2mm thock moulded prelaminated PVC sheet on front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site. all as per specification and drawing complete all as specified and as directed. |
| 48 | M&L Butt hinges, medium weight, cold rolled mild steel, welded to steel frame work of 100mm size complete all as specified and as directed. |
| 49 | M&L 125mm size aluminium handle fabricated type anodized all as specified and as directed. |
| 50 | S&F 125 mmlong Aluminium, anodized, barrel tower bolts of extruded sectioncomplete all as specified and as directed. |
| 51 | S&F Rotational moulded polythelene water storage tank double Layered (cyclinderical vertical with closed top) hoisted and fixed in position of 1000 Ltrs capacity all as specified and as directed. |
| 52 | S&F Ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete of 20mm bore dia all as specified and as directed. |
| 53 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15 mm, complete all as specified and directed. |
| 54 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, complete all as specified and directed. |
| 55 | S&FStop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 20mm bore, complete, fixed in repairs, complete all as specified and directed. |
| 56 | S&F75 mm PVC pipes single socketed, in any length, laid in trenches or in floors complete all as specified and directed. |
| 57 | S&F 100 mmPVC pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 58 | S&F100 mm PVC( SWR ) bends (any radius) with oval access doors. Make ISI marked complete all as specified and directed. |
| 59 | S&F 75 mm PVC( SWR ) bends (any radius) with oval access doors. Make ISI marked complete all as specified and directed. |
| 60 | S&F 100 mm PVC( SWR )Single T (any radius) with oval access doors. Make ISI marked complete all as specified and directed. |
| 61 | S&F 75 mm PVC( SWR ) floor trop , plainwithgrating including jointing with solvent cementcomplete all as specified and directed. |
| 62 | S&F 100mm PVC (SWR) vent cowl complete all as specified and directed. |
| 63 | S&F one piecewash down water closet pan, white (EWC) 650x345x720 including duroplast slim soft close seat cover and jet, flushing system and necessary fittings etc and fixed in position complete all as specified and directed. |
| 64 | S&F Vitreous china wash basin (table top) white flat back size 580x450 mm incl 32 mm chromium plated bottle trap excluding taps waste chain and plug and porcelain stopper but including brackets, complete all as specified and directed. |
| 65 | S & F fancy type chromium plated with long shank and cup,Angle stop valvecast copper alloy, with capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixed complete all as specified and directed. |
| 66 | S&FPVC connection 15mm size with PTMTnuts of length 450 mm longcomplete,all as specified and as directed. |
| 67 | S&F Tubular towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between Hangs, complete all as specified and directed. |
| 68 | S&F 1200x900x6 mm bevelled edge mirror of selected quality glass, fixed with stainless steel bolts & nuts, all as specified and as directed. |
| 69 | S&F Fancy type Brass CP wash hand basinmixer for mixing hot & cold water, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unionscomplete all as specified and directed. |
| 70 | S&F Hand shower (Health faucet) brass chromium plated with 1 meter long easy flex tube in chrome finish and wall hook, complete all as specified and directed. |
| 71 | S&F Toilet paper holder of vitreous china, fixed to walls with chromium plated (CP) brass screws fixed in repairs complete, all as specified and directed. |
| 72 | S&F Stainless steel grating of 125mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, fixed in repairs, complete all as specified & directed. |
| 73 | S&F Suspended false ceiling system using E grid suspended ceiling grid system Grid size 600mm x 600mm with and including G.I frame work of main runners 38mm x 24 mm , cross tee 28mm x 24mm and wall angle 24mm x 24mm hot diped galvanised steel with zinc coating not less than 120 gm/ sqm using 4mm thick high pressure steam cured fibre cement pre primed textured variant E board classic ISI marked IS-14862-2000 to be placed in grid of E grid suspended ceiling grid system duly suspended by 6 mm dia gi bar hangers from existing purlins to roof with butterfly clips complete allas specified and directed. |
| 74 | M&L for preparation of newly plastered surface of walls/ceiling including corners and applying two coats ofdistemper oil emulsion over applying of 1 mm thick wall care putty finish wall surface even & smooth all as specified and directed. |
| 75 | Meterial and labour for preparation of newly plasstered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay echnology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specification, Anti Algal properties in Two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instruction applied over one coat 1\"1 ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airlesspray machine of paint application with a flow speed of inium 1 ltr per minute having a pressure of 300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed Make : Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total/ Asian Paint Apex Ultima/ JK Maximo Ultra. Notes for smart periodicals (a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) the contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator before quoting the bids and submit the same alongwith tender & other Documents as mentioned in NIT (c) Cost of scaffolding at any height shal be included in thequoted rate. (d) Preparation of plastered or unplastered surface of removal of existing treatment by scrappigng of walls, chajjas, ceiling, fins, fascias, parapets etc shall be done by using mechanial sander with internal dust extraction system for clean environment certified by the manufacturer. After the prepartaion of surface written approval shall be obtained from GE before applying primer and further tratment/ coat. Bldg wise stage passing register shall be maintained. (e) Finishes ie cement based paint, acrylic water based exterior grade primer, premium acrylic smooth exterior emulsion etc to walls, ceiing, chajjas, fins, fascias, parapets etc shall be applied using airles spray technology and capable of operating single spray gun with a suitable hose length. the spray machine should be of are putted majufacturer with pro-guard technology and capability of traking pressure as well as paint and primer usage. (f) This equipment shall be certified by approved manufacturer. (g) The accessories for applying the finishes shall be spray in hard to reach areas ad penetration of finishes on the surface so as to achieve uniform appication and quality surface finish. Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"AB\" on page no. 95of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 76 | M&L for Home Sheild PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied water-proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97 a waterproofing and heat reflecting system having following key performace properties : 1. UV resistant, prevent yellowing and weathering2. Highly elastic upto 350% and crack bridging3. Excellent adhesion on porous and non-porous substrates4. Tensile strength > 10 N/mm2 with Geo Textile fleece5. Soler reflective Index(SRI) more then 109-111 ASTM E 1980-11 System :First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent)Coverage :0.2kg/m2 (with 50 % dilution of water)Reinforcement : Geotextile 40 gsmSecond coat : Home sheildroofkoat (or equivalent)Consumption : 0.5 kg/m2Third coat : HS PU roofkoat (or equivalent)Consumption : 0.8 kg/m2 System buildup-1.5kg/sqm with geotextile of 40 gsmFor accessible roof, tiles with scred/ adhesive may be fixed thereafter.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"CD\" on page no. 99 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 77 | S&F mild steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connectedto common rafters and running rail and guides for sliding doors; fixedwithangle cleats or other connecting plates Fe 410-W(Gde E- 250) quality A complete all as specified and directed. |
| 78 | S&F prepainted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self taping screws complete all as specified and directed. |
| 79 | S&F prepainted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self taping screws as spd. |
| 80 | M&L for point wiring for one light point / fan point / bell point controlled by one-way switch with 1.5 sqmm FRLS PVC insulated, unsheathed, single core, multi-stranded copper conductor cable, 1100 volts grade, drawn through and including concealed rigid PVC conduit (medium grade) of suitable diameter, laid during roof casting and wall construction, with 1.5 sqmm FRLS copper conductor cable as earth continuity wire connected to common earth dolly, terminated in and including modular type pressed steel sunken box (wall thickness not less than 1.22 mm up to 200 × 300 mm and 1.63 mm for larger sizes) with 3 mm thick modular polycarbonate cover plate suitable for mounting modular switches/sockets/regulators etc., including cutting chases if & where required, making good disturbed surfaces with cement mortar (1:3), finishing to match existing surface complete, all as specified and as directed by the Engineer-in-Charge. |
| 81 | All as per item no-1 above but for one Exhaust fan point controled by one piano switchcomplete, all as specified and as directed |
| 82 | All as per ser item No 1 hereinbefore but for one 3 pin socket outlet 5 Amp Same. |
| 83 | All as per ser item No 1 hereinbefore but for one 3 pin socket outlet 5 Amp independent. |
| 84 | All as per Item no 1 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wirecomplete, all as specified and as directed |
| 85 | All as per Item no 1 here-in-before but for one Metal clad switch socket outlet for AC/Geyser connection, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. (For geyser & ACs) |
| 86 | S&F one way 6 Amps, 230 Volts modular switch, ISI marked, single module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 87 | S&F one way 16 Amps, 230 Volts modular switch, ISI marked, single module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 88 | S&F 5 Amps, 230 Volts, 3-pin modular socket outlet, ISI marked, 2 module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 89 | S&F 5A/16A universal type, 230 Volts, 5-pin modular socket outlet, ISI marked, 2 module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 90 | Supply and fixing of sheet metal enclosure housing single pole and neutral switch socket outlet with two-pin and earth plug and socket, complete with one single pole MCB up to 20 Amps, suitable for 240 Volts, including all necessary internal wiring, connections and testing on completion, complete, all as specified and directed |
| 91 | Supply and fixof Ceiling rose surface bakelite three terminals 240 volts complete, all as specified and as directed. |
| 92 | Supply, installation, testing and commissioning of LED mirror light, 10 W, suitable for mounting above wash basin mirror, of slim decorative design with aluminium / MS body and acrylic diffuser, cool white / warm white (3000K–6500K), CRI ≥ 80, power factor ≥ 0.90, flicker-free driver, operating voltage 180–260 V AC, and rated life of minimum 25,000–50,000 burning hours, complete with all necessary fixtures, internal wiring connections, accessories and commissioning at site complete, all as specified and as directed.Note : Model and variant of approved make shall be selected and approved by the GE. |
| 93 | S&FLED tube light fitting 20/22 watts, 220 volts AC ,6500K Colour temp, length 4 ft appx, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Note : Model and variant of approved make shall be selected and approved by the GE. |
| 94 | Supply, Installation, Testing and Commissioning of 36W LED Panel Light, 2’x2’, recessed type suitable for modular false ceiling (600x600 mm). Fixture shall be aluminium housing with glare-free diffuser, system wattage 36W ±10%, cool white (5700K–6500K), PF ≥0.95, CRI ≥80, efficiency ≥100 lm/W, flicker-free driver, surge protection ≥2.5 kV, THD ≤10%, operating voltage 140–270V AC, IP20 rating, and minimum 50,000 hours service life (L70). Complete with all required accessories and commissioning at site complete, all as specified and as directed.. (At junction of old to new Bldg)Note : Model and variant of approved make shall be selected and approved by the GE. |
| 95 | S&F bulk head light fitting LED 10 Watt, 230 Volts, IP65 weather proof, energy efficient, die-cast aluminium body with polycarbonate diffuser, complete with necessary terminal block, gasket, hardware and connection with flexible copper conductor cable including fixing on wall/ceiling with suitable screws and rawl plugs all as specified and directed.Note : Model and variant of approved make shall be selected and approved by the Engineer-in-Charge. |
| 96 | Supply and fix IP 66 Integral LED security light luminaire 35 W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & heat resistanttoughned glass ,efficacy 110 lumens/watt, external 10KV,440 volt SPD and inbuilt 4KV , IP 67 potted isolated driver with operating range 902V to 340V AC .CCT 5700K,LED life -1 lakh burning hours,fixture should withstand 320 volt upto 48 hrs , Auto cut off >320 volts & restart,440 Volt sustainupto 8 hrs,NABL Acreddited LM79 report including GI pipe 40mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable sizecomplete all as specified and as directed. |
| 97 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 10 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 10 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (from TPN to SPN) |
| 98 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (For security light & 2X2 panel) |
| 99 | S&F energy-efficient ceiling fan, 1200 mm sweep, complete with blades, downrod, with in-built electronic speed controller and remote control and all standard accessories, 230 V single-phase operation, BLDC (Brushless Direct Current) motor type, 5-Star BEE rated, delivering minimum air flow of 210 CFM and service value not less than 6.0, including electrical connections, testing and commissioning, all as specified and directedNote : Make and model of approved make to be selected and approved by the GE. |
| 100 | S&F exhaust fan steal body of 300 mm sweep, 230 V, complete with blades, frame, louver/shutter and all standard accessories, including cutting of wall to required size, fixing the fan in position with proper mounting arrangement, making connections from ceiling rose , and making good the disturbed wall surface with cement mortar/finishing to match the existing surface, testing and commissioning, all as specified and directed.Note : Make and model of approved make to be selected and approved by the GE. |
| 101 | Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 35 Sqmm, 4 core including making electrical connection with thimbles complete all as specified. |
| 102 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specifed. |
| 103 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified. |
| 104 | Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified. |
| 105 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid. |
| 106 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified. |
| 107 | Supplying and laying GI tubing light grade of size 40 mm bore for cable protection complete all as specified. |
| 108 | S&F TPN vertical type distribution board, 4-way, double door, 415 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory-wired for three phase and neutral, complete with 200 Amps rated busbar, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB in position, reinstating the surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed. |
| 109 | S&F SPN distribution board, 8-way, double door, 240 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory wired for single phase and neutral, complete with 200 Amps rated busbar, suitable for incoming MCB/Isolator up to 63 Amps and outgoing MCBs as required, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB, reinstating the wall surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed |
| 110 | S&F SPN distribution board, 4-way, double door, 240 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory wired for single phase and neutral, complete with 200 Amps rated busbar, suitable for incoming MCB/Isolator up to 63 Amps and outgoing MCBs as required, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB, reinstating the wall surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed |
| 111 | S&F TPN MCB 40–100 Amps, 415 Volts, 10 kA breaking capacity, B-curve, ISI marked, conforming to IS/IEC 60898-1, suitable for three-phase four-wire system, fixed in distribution board with necessary connections including phase, neutral and earth, complete with testing on completion, all as specified and directed. |
| 112 | S&FMCB SP of rating 6 to 32 Amps, 240 Volts, 10 kA breaking capacity, C-curve, ISI marked, conforming to IS/IEC 60898, fixed in DB with necessary connections, testing on completion, all as specified and directed |
| 113 | S&F SPN MCB 40-63 Amps, 240 Volts, 10 kA breaking capacity, C-curve, ISI marked, conforming to IS/IEC 60898, fixed inDB with necessary connections and testing on completion, all as specified and directed |
| 114 | Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion. (For TPN DB) |
| 115 | Supply & laying Mild steel galvanised iron water tubing of size 25 mm borewith screwed & socket joints, medium grade, galvanised, with all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches through new routes or under roads including taking down of old water tubing of same size, complete , all as specified and asdirected. |
| 116 | Mild steel galvanised iron water tubing, 20 mm bore, with screwed & socket joints, medium grade, with all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to wall upto 12 metre height and ceiling or laid in trenches/under floors including taking down of old water tubing of same size, complete all as specified and directed. |
| 117 | Supply and Fix gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for pipe dia 20 mmcomplete all as specified and directed. |
| 118 | Supply and Fix gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for pipe dia 25 mmcomplete all as specified and directed. |
| 119 | Cutting into existing water supply main of any size up to 50 mm bore and providing 25 mm bore branch connection, including insertion of unequal tee, jointing, testing and making good, complete, all as specified and as directed. |