| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish complete all as specified and directed. |
| 2 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 3 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tilesincluding 15 mm thick screed bed in cement mortor 1:4complete all as specified and directed. |
| 4 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal ofdebris and rubbish to a distance complete all as directed by the Engr-in-Charge |
| 5 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 6 | M & L for 75 mm thick, plain cement concrete 1:2:4,type B-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etc complete all as specified and directed. |
| 7 | M & L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey pigment cement and pigments including over 20mm thick screed bed in CM 1:6,complete all as specified and directed. |
| 8 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 9 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 979 grade St.-240 complete all as specified and directed. |
| 10 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 11 | M & L for Preparation of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 12 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 13 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 14 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 15 | Demolition of brick work or stone / boulder masonry, concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish complete as directed by the Engr-in-Charge. |
| 16 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate),block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and including setting in mortar 1:4 complete all as specified and directed. |
| 17 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 18 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 19 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 20 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets/ snap grid frame etc complete all as specified and directed. |
| 21 | S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturer\"s instructions including 4 mm thick non asbestos E-board, HSPC, designer fixed to framecomplete all as specified and directed by the Engr-in-Charge. |
| 22 | S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 23 | Taking down shutters of any descriptionexc 2 sqm each complete all as specified and directed. |
| 24 | S & F 35 mm thick, Flush shutters, solid core construction, with block board core and plywood both face panels, commercial type on both sides complete all as specified and directed. |
| 25 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 26 | S & F 300 mmAluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt complete all as specified and directed. |
| 27 | S & F 100mm long, Butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 28 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 29 | S & F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 30 | S & F 30 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed. |
| 31 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 32 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 33 | S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i)Thickness of aluminium section shall not be less than 1.5 mm). |
| 34 | S & F 3 mm thick, sheet glass,ordinary quality and glazing with oil puttyin square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 35 | M & L for preparation of old treated surfaces of cement bonded particle/asbestos sheet as in roof covering/wall over 10cm girth or width by cleaning if any removing rust and making good with red best putty where required and applying one coat of synthetic enamel paint on wall and ceiling old surfaces , complete all as specified and directed. |
| 36 | S & F 24 mm outer dia, stainless steel, curtain rail/rod, heavy duty, minimum 1mm wall thick including brackets, side holder and rings etc fixed to /wall etc complete all as specified and directed.(Note: (i) Stainless steel decorative finials and stainless steel brackets shall be provided for each leangth of curtain rail/rod and cost of the same shall deemed to be included in the unit quoated rate. (ii) Length of of curtain rail/rod shall only be measured for payments) |
| 37 | M & L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 38 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tilesincluding 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 39 | M & L for 100mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etc complete all as specified and directed. |
| 40 | M&L Sand filling under floors or in foundations including watering and consolidation and including spreading & well ramming in layers not exc 25 cm complete all as specified and directed. |
| 41 | M & L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment, complete all as specified and directed. |
| 42 | M & Lfor plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as inin roof kerbs or mud stops, rounded or chamfered on edges,complete all as specified and directed. |
| 43 | S&F in repairs second class hard-wood clean sawn as in scantlings timber framed and fixed, complete all as specified and directed. |
| 44 | S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 45 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and disposal ofdebris and rubbish to a distance complete all as directed. |
| 46 | M & L for Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in landing, cover slabs (for man holes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed.(Note: Reinforcement shall be measured and paid seperately) |
| 47 | S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 48 | Taking down shutters of any descriptionexc 1 sqm but n. exc 2 Sqm each complete all as specified and directed. |
| 49 | S & FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed. |
| 50 | S & F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specifiedcomplete all as specified and directed. |
| 51 | S & F 125 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 52 | S & F 75mm long, Butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 53 | S & F 125 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 54 | S & F vitreous China wash down water closet pan (pedestal pattern), white, with PVC (SWR) \"P\" or \"S\" trap including connection to outgoing drain andflushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 55 | S & F vitreous China wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, 32mm dia, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed. |
| 56 | S & F in repair 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 57 | S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white,with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 58 | S & F 15mm bore, bib taps, fancy type, long body with wall flange cast copper alloy, chromium plated with handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 59 | S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered \"Hot or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 60 | S & F in repairs, 15 mm bore, Stop valves,cast copper alloy,fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 61 | S & F 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed. |
| 62 | Supply, laying, connection and testing, 20mm bore, cPVC pipes SDR 13.5 pipes & plain cPVC SDR 11 fittings on walls/ceiling or laying in floors, etc and including taking up or down un- serviceable pipes complete all as specified and directed. |
| 63 | Supply, laying, connection and testing, 25mm bore, cPVC pipes SDR 13.5 pipes & plain cPVC SDR 11 fittings on walls/ceiling or laying in floors, etc and including taking up or down un- serviceable pipes complete all as specified and directed. |
| 64 | S & F in repairs 1000 litres capacityrotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position and including 20 mm bore,Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight - 210 gms) complete all as specified and directed. |
| 65 | S & F 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 66 | S & F in repairs, Coloured, Toilet paper holder of vitreous china, box type fixed to wall with chromium plated brass screw complete all as specified and directed. |
| 67 | S & F 125 mm size, shower rose, with shower arm, brass chromium plated, swival type, complete all as specified and directed. |
| 68 | S & F 15 mm bore, Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) with all accessories complete all as specified and directed. |
| 69 | S & F 20 mm bore, Brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and directed. |
| 70 | S & F cast iron floor trap 100mm diameter of outlet with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 71 | S & F 110 mm bore, PVC (SWR),Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc including taking down old unserviceable pipes, completeall as specified and directed. |
| 72 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 73 | S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal with access door, jointing with solvent cement ,complete all as specified and directed. |
| 74 | S & F 75mm bore, PVC (SWR),Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc including taking down old unserviceable pipes, completeall as specified and directed. |
| 75 | S & F 75mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 76 | S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal with access door, jointing with solvent cement ,complete all as specified and directed. |
| 77 | S & F 100 mm bore, PVC (SWR) vent cowl complete all as specified and directed. |
| 78 | S & F in repair stainless steel Grating, 100mm dia with or without waste hole fixed with white cement complete all as specified and as directed. |
| 79 | S & F in repair jet spray with connection pipe 15mm bore dia, brass chromium plated and suitable for wash down water closet pan (pedestal pattern) complete all as specified and as directed. |
| 80 | S & FCompound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and directed. |
| 81 | Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified anddirected. |
| 82 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 83 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 84 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 85 | M & Lfor Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 86 | M & L for use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all asspecified and directed. |
| 87 | M & Lfor Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, etc complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 88 | M & L for use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all asspecified and directed. |
| 89 | S & F high strength TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 90 | M & L for Writing letters or figures (Block ,Roman, Italicor Indian) n. exc 30 cm height with synthetic enamel paint complete all as specified and directed. |
| 91 | M & L for preparation of newly plastered and concrete surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 92 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 93 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 94 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 95 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 96 | M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 97 | All as per item No. 96 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 98 | All as per item No. 96 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 99 | All as per item No. 96 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 100 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 101 | S & F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 102 | S & F Switch socket combination 2 in 1, 3 pin, 6 Amp, flush type, universal complete all as specified and as directed. |
| 103 | S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. |
| 104 | S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 105 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 106 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. |
| 107 | S & F 2ftx2ft recessed mounting, LED panel light fittings, 40 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. |
| 108 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specifiedand directed. |
| 109 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. |
| 110 | S & F LED Bulb, 15 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. |
| 111 | Taking down and dismantling the ceiling fan/exhaust fan of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required and re-fixing fan in its existing position complete all as specified and directed. Note : (i) The cleaning, servicing, oiling, rubber seal, greasing and lubricating of ceiling fans has to be carried at site itself and expdr cost deemed to be inclided in qupted rates. (ii) Cost of hanging hook/extended MS pipe/rod if required to be fixed properly deemed to be included in the quoted rates. |
| 112 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection, IK 09complete all as specified and as directed. |
| 113 | S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed |
| 114 | S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed |
| 115 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed. |
| 116 | S & F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 117 | S & F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed. |
| 118 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor 16 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed. |
| 119 | S & F in repair Street light bracket arm of length not less than 60 cm made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp 40x5mm of suitable length, nuts, bolts & washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 120 | M & L Sub main wiring with two runs of 4.0 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn throughincluding PVC Casing capping of suitable size with all accesories and fittings,fixed to wall/ceiling etc including4.0 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete all as specified and as directed. (Note : Two run cables and one run of earth wire and one run of casing capping will be measured as one length.) |
| 121 | S & FLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specifiedand directed. |
| 122 | S & F sheet metal enclosurewith socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed. |
| 123 | S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09complete all as specified and as directed. |
| 124 | S & F MCB SPN 40A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed |
| 125 | S & F Exhaust fan, 250 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls complete all as specified and directed |