| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 3 | Dismantling timber scantlings 40 Sqcm and over in any position in framed work complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 6 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 or other cuting plates complete all as specified and directed. |
| 7 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | All as per Sl item No. 7.00above but except sheeting complete all as specified and directed. |
| 9 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 10 | M&L 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roof, walls etc. fixed with L-T type or J-type or cranked hook bolts etc. complete all as specified and directed. |
| 11 | All as per Sl item no 10.00 above but except sheet. |
| 12 | M & L Asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with \"J\" type hook bolts etc. complete all as specified and directed. |
| 13 | M&L 2nd class hard wood scantling clean sawn, timber fixed for purlins, posts, rafters etc. complete all as specified and directed. |
| 14 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed. |
| 15 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm, using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer\"s complete all as specified and directed. |
| 16 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 17 | M&L for providing and fixing gypsum board 10 mm, thick in ceiling fixed with screws as per manufacturer instruction complete all as specified and directed. |
| 18 | M&L for 4 mm thick nonAsbestos fibre cement designer building boards, fixed or laid/inserted totimber/GI/Aluminium framework with screws (if fixed in ceiling flat or sloping) complete all as specified and directed. |
| 19 | M&L for preparation of new ceiling surfaces and applying two coat of oil bound distemper complete all as specified and as directed. |
| 20 | Dismantling boarding, any description, fixed in any position with nail complete all as specified and directed. |
| 21 | M&L forsecond class hardwood Weather boarding,clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 22 | Fixing onlysencond class hardwood Weather boarding,clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 23 | M&LPreparing new surfaces of wood of any description not otherwise described over 10cm width or girth and applying two coats ofsynthetic enamelpaint over a coat of pink primer complete all as specified and directed. |
| 24 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed. |
| 25 | Dismantling old brocken floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premices complete all as specified and directed. |
| 26 | Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level complete all as specified and directed. |
| 27 | M&L forVitrified Ceramic tiles light shade 8 to 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 28 | M&L forVitrified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM (1:4) complete all as specified and as directed. |
| 29 | M&L forfor non skid joint free coloured ceramic tlle 7 to 8 mm thick (square or rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white/coloured cement to match with and incluiding 15 mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 30 | M&L for joint free non skid colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in, skirting, dado, etc incl 10mm thick rendering in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. |
| 31 | M&L coloured ceramic glazed tiles 375x250x7mm/ 450x300x7mm thick as in dado/skirtingetc including 10 mm thick rendering in CM 1:3, set & jointed in neat cement slurry & pointed in white or coloured cement slurry & pointed in white or coloured cement complete all as specified and directed. |
| 32 | M&L for joint free non skid colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. |
| 33 | M&L PCC 1:2:4 type B-0(using 12.5mm graded crushed stone aggregate)in levelling course etc complete all as specified and directed. |
| 34 | M/L for PCC (1:5:10) type E2 using 40mm graded brick aggregate as in sunken portion, sub base, etc complete all as directed at site. |
| 35 | M&L Rendering 10 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound@ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smoothwithout using extra cement over roof / sunken slab /wall complete all as specified and directedNOTE : Water proofing liquid will be measured and paid seperately |
| 36 | Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm in sunken portion including cleaning of surfaces complete all as specified and directed. |
| 37 | S&F 50mm bore tubes light grade galvanised with all fittings laid in flooras in spout pipe, etc complete all as specified and directed. |
| 38 | Taking up or down steel tubing and connection of 15 mm bore complete all as specified and directed at site |
| 39 | All as per Sl item No. 38.00 above but for 20 mm dia bore pipe |
| 40 | All as per Sl item No. 38.00 above but for 25 mm dia bore pipe |
| 41 | Supplying and laying of CPVC pipes of outer dia 16mmSDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 42 | All as per Sl item No. 41.00 above but size of 20 mm dia |
| 43 | All as per Sl item No. 41.00 above but size of 25 mm dia |
| 44 | Refixing old steel tubing and connections of 15mm or 20mmin new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. |
| 45 | Refixing old steel tubing and connections of 25mmin new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. |
| 46 | Disconnecting existing water tanks of capacity exceeding 250 Ltr but not exceeding 500 Ltr setting aside (or lowering if required) for repairs, leaning, etc. and hoisting if required reconnecting and re-fixing in positioncomplete all as specified and as directed. |
| 47 | Disconnecting existing water tanks of capacity exceeding 500 Ltr but not exceeding 1000 Ltr setting aside (or lowering if required) for repairs, leaning, etc. and hoisting if required reconnecting and re-fixing in positioncomplete all as specified and as directed. |
| 48 | S&F in repair 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I, screwed for iron/cpvcpipe and fixed complete all as specified and directed. |
| 49 | S&F in repair 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I, screwed for iron/cpvcpipe and fixed complete all as specified and directed. |
| 50 | S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron/cpvc pipe and fixed. (Minimum weight-210gms) complete all as specified and directed. |
| 51 | S&F 25mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight--455gms) complete all as specified and directed. |
| 52 | S&F in repair for 10 ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed. |
| 53 | S & F in repair for PVCconnection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed. |
| 54 | S&F in repair 15mm dia angle stop valves cast copper alloy faney type,chromium plated complete all as specified and directed |
| 55 | S&Fin repair for Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed. |
| 56 | S & F in repair, 15mm borebib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 57 | S & F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipecomplete all as specified and directed. |
| 58 | S&F in repairs for shower rose chromium plated with or without swivel joints 125 mm dia complete all as specified and directed. |
| 59 | S&F in repair vitrious china wash basin, white flat back size 550 x 400 mmincluding waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waiste pipe fitted complete all as specified and directed. |
| 60 | S&F vitreous china squatting pan ORRISA Pattern of size 580x 440mm white with integral foot rest complete (excluding cistern and flush pipe) with provn of lime concrete including backing joints complete all as specified and directed at site. |
| 61 | S&F in repair Vitreous china wash down water closet pan ( pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including P or S trap, sheet cover ofwhite colour complete all as specified and directed. |
| 62 | S&Fhealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections complete all as specified & directed. |
| 63 | S&Fin repairs 15mmdia pillar tap cost copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without letered \"Hot or Cold\" high pressure with long screwed shanks & fly nuts screwed for iron pipe etc complete all as specified and directed. |
| 64 | Supply and fix shelf 450mm longof PTMT fixed with and incl chromium plated brass screws and wooden /plastic cleats (minimum weight 300 grams) complete all as specified and directed. |
| 65 | S&F CP towel rail, 20mm dia, D type,60cm long complete all as specified and directed. |
| 66 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etccomplete all as specified and directed. |
| 67 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 68 | M&L brick work with sub class \"B\" brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 complete all as specified and directed. |
| 69 | M & L for rendering 10 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 70 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) withusingWPC on wall finishing the surfaces even and fair without using extra cement in two separate coats (10mm thick backing coat and 5mm thick finishing coat. Finishing coat shall be mixed with water proofing compound as manufacturer instructions) complete all as specified and directed. Note : WPC shall be measured seperately. |
| 71 | M&L for 5 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 72 | Supply only water proofing compound (liquid),ISI marked complete all as specified and directed. |
| 73 | M&L for preparation of newly plastered surface and applying two coat of oil bound distemper over a coat of alkali resistant primer including two coat of wall care putty complete all as specified and as directed. |
| 74 | M&L for preparation of newly plastered surface of ceiling and applying two coat of oil bound distemperover a coat of alkali resistant primer complete all as specified and as directed. |
| 75 | M&L for preparation of newly plastered surface and applying two coat ofAcrylic Smooth exterior paint of required shade (Camouflage) appliedover and including priming coat of exterior primercomplete all as specified and directed. |
| 76 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins, heads, shoes, bends, swan-necks, etc. including removing from site complete all as specified and directed. |
| 77 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 78 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. |
| 79 | S&F PVC (SWR) bends 110 mm bore of any radius all as specified & directed. |
| 80 | S&F PVC (SWR) bends 75 mm bore of any radius all as specified & directed. |
| 81 | S&F PVC (SWR) junction single (singleT) equal or unequal110mm bore provided with access door all as specified & directed. |
| 82 | S&F 110 mm bore PVC (SWR) vent cowl complete all as specified & directed. |
| 83 | S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement complete all as specified & directed. |
| 84 | S&F 110mm dia PVC (SWR)WC connector with lip ring complete all as specified & directed. |
| 85 | Taking down aluminium doors shutters only (area exc 1.0 sqm but not exc 2.0 sqm each)and dismantling all members and reassembling the same with and including new screws, new rubber gasket,new aluminium beads & cleats of existing make and also refixing the handles & mortice locks in existing position with and including new screws including refixing the door shutters in same opening complete all as specified & directed. |