| Sl. No. | Item Description |
| 1 | Building work:Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each complete all as specified. |
| 2 | Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm butnot exceeding 4.0 Sq.m each complete all as specified. |
| 3 | Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified. |
| 4 | S&F Factory made double riveted WPC (wood polymer composite) solid door frames/chowkat of size 65x125 mm of virgin PVC Polymer of K value 58-60(Suspension Grade) calcium carbonate and natural fibres (wood/powder/rice husk/wheat husk ) and non toxicadditives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threated star heads SS screw having minimum frame density of 750 kg/cum screw withdrawal strenght of 2200 N (face) and 1100 N (Edge)proof, water/moisture proo, minimum compressive strenght of 58 N/mm2, modules of elasticity 900 N/mm2 and serestance to spread of flame of Class A category with property of being termite/borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 5 | S&F Factory made singleriveted WPC (wood polymer composite) solid door frames/chowkat of size 65x100mm of virgin PVC Polymer of K value 58-60(Suspension Grade) calcium carbonate and natural fibres (wood/powder/rice husk/wheat husk ) and non toxicadditives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threated star heads SS screw having minimum frame density of 750 kg/cum screw withdrawal strenght of 2200 N (face) and 1100 N (Edge)proof, water/moisture proo, minimum compressive strenght of 58 N/mm2, modules of elasticity 900 N/mm2 and serestance to spread of flame of Class A category with property of being termite/borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 6 | S & F 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solidflush SKELTON door shuttercomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistur proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hingesshall be paid separately) |
| 7 | S&F 30mm thick molded WPC wire mesh factory made 1005 decorative type, moulded,panel door shutter prepare to receive Mesh, gauze etc (single or two panel Including wire mesh(confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 650kg/cum manufactured by an ISO : 9001-2015 certified company.The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capasity. |
| 8 | S & F Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified. |
| 9 | S & F 250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified. |
| 10 | S & F 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified. |
| 11 | S & F Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified. |
| 12 | S & F 300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified. |
| 13 | S&Ffabricating coloured powder coated(minimum thickness of powder coating 50 micron) aluminium frame work door,windows , ventilators,with one or more rebates sections of approved tint as requiredincluding beading,cleat, screws,fasteners, plugs, for fixing with wall/ceiling columns/beams etccomplete all as specified and directed. |
| 14 | S&F aluminium coloured power coated door/ window(minimum thicknessof powder coating 50 micron) (sliding type)/ventilator shutterswithout sash bar alu section weighing 0.55 kg/m including necessary locking arrangement, guide wheels, joining cleats, glazing clips rubber packing anodised alu snap beading screws etc complete all as specified and directed. |
| 15 | S&F 4.8 mm thick plain or tinted glass, ordinary quality including rubber gasket for packing and fixed to aluminium Ventilator/window/ incl necessary cutting / moulding and chamferrring of edges for service window/counters complete all as specified and directed. |
| 16 | S & F for galvanised Stainless steel wire cloth of0.36mm dia wire and average width of aperture 1.4mm & fixed with tacks of stainless steel wire staples,etc complete all as specified and as directed. |
| 17 | Supply and fix7 mm thick aluminium coloured power coated grill of Deco Grill pattern DG 104, fixed in aluminium windows / ventilators, etc.including necessary aluminium channels in openings of windows / ventilators, complete all as specified and as directed. |
| 18 | S&F for Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick inDouble rebate windows in which both glazed shutter andflymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutterand wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each,PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm .Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screwsafter drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. |
| 19 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed |
| 20 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm With Semi perforated 12mm thick micro tegular edged or 1 0 mmthick square edgedof approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of85% (minimum) to be laid in truehorizontal level suspended on inter locking metal T-Grid of hot dippedgalvanized iron section of 0.33mm thick(galvanized @ 120 grams per sqmincluding both sides) comprising of main T runners of size 15 x 32 mm of length3000mm,cross-T of size 15x 32mm oflength 1200mm and secondary intermediate cross-T of size 15 x 32 mmof length 600mm to form grid module of size 600x 600mm , suspended fromceiling using galvanized mild steel items(galvanizing @ 80 grams per sqm) i.e50mm long, 8mm outer diameter M-6dash fasteners, 6mm dia fully threadedhanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm.Galvanised iron perimeter wall angle ofsize 24x 24x0.40mm of length 3000 mmto be fixed on periphery wall I partitionwith the help of plastic rawl plugs at 450mm center to center and 40mm long drywall wood screws. The work shall becarried out as per specifications, drawingand as per directions of the Engineer-in Charge. |
| 21 | Material & Labour in repair for providing ‘E’ board ceiling as in repair, 4 mm thickwith GI framed work with main tee of size 24 x 28.5 mm made out of PGI sheet 0.3 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and wall angles 24x24x0.45 mm powder coated for ceiling, ceiling board 60cmx60cmx4.00mm thick, suspended with GI wire 2 run of 2 mm dia & upto 2 M average length with adjustable device complete incl plugging in brick/stone wall with steel rawl plug & 600 mm C/C. Ceiling board shall be pressed to the ceiling tee), complete all as specified and directed incl making good all the disturbed portion complete all as specified and directed |
| 22 | S&F in repair for stainless steel, 25 mm dia and 1.2 mm thick curtain rod with and including fixing SS bracketsand decorative type stainless steel knobs both side of each rod, complete all as specified and directedNote- Measurement will be taken between end points of Knobs |
| 23 | S&F 18 mm thick with min density 600 Kg/cu.m LEAD FREE PVC Celuka ply of single side rigid laminate of approved color and other side plain white colour fixed with ss screws ans solvent cement/ adhesive to make kitchen cabinet shutters complete as per manufacturer’s instructions complete all as specified and directed |
| 24 | S&F 6mm thick with min density 600 Kg/cu.m LEAD FREE PVC Celuka ply of single side rigid laminate of approved color and other side plain white colour fixed with ss screws ans solvent cement/ adhesive to make kitchen cabinet shutterscomplete as per manufacturer’s instructions complete all as specified and directed |
| 25 | S&F 15mm Continuous (piano) hinges,mild steel, bright finish or electrogalvanised for kitchen cabinet shutters complete in all respect and fixed in position all as specified |
| 26 | S&F D-type cabinet handles premium quality, stainless steel 304/gloss chrome/SN finished150mm long matt finished complete fixed in position all as specified. |
| 27 | Demolition of brickwork or stone boulder masonrybuilt in mud mortar including all quoins, arches, pillars etc complete all as specified. |
| 28 | M&L brick work withfly ash bricks , usingold sizebricks, straight or curvedon plan exc 6 m meanradius built in cement mortar1:6 upto height of 10m including necessary scaffolding arrangement complete all as specified. |
| 29 | M&L forburnt clay, brick work withsub class\"B\" bricks (but except brick) , usingold sizebricks, straight or curvedon plan exc 6 m meanradius built in cement mortar1:6 upto height of 10m including necessary scaffolding arrangement complete all as specified. |
| 30 | M & L for walling of random rubble stone masonry, un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed. |
| 31 | M & L for walling of random rubble stone masonry (but except stone), un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed. |
| 32 | Extra over stone walling for hammer dressing to faces of stone and dressing of faced beds and joints as specified for RR walling uncoursed or brought upto courseshammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40mm for lime or sand stone complete all as specified and directed. |
| 33 | M&L for raised pointing to RR or Polygon rubble uncoursed or brought upto course in cement mortar 1:4 complete all as specified and directed. |
| 34 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified. |
| 35 | M&L for glazed ceramic coloured tiles(Matte/Gloss Finish) of size not less than 450x300x7 mm thick as on vertical surfaces such as wall set and jointed in neat cement slurry and pointed with coloured cement to match over 10 mm thick backing coat on fair faces of brick work in CM 1:4 complete all as specified and as directed. Note: Pattern/Texture and Finish of wall Tile is selected by Engr-in - charge. |
| 36 | M& Lfor Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade oftiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified. |
| 37 | M&L for scratch & Jointfree Glazed(Porcelain) Vitrified Tiles(GVT)/Polished Glazed Vitrified Tiles(PGVT) 9mm-10mm thick (square or rectangular) area of each tile exceeding 0.18sqmbut not exceeding 0.36 sqm ie size 600x600mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified and as directed.Note : 1.Size and pattern/texture of GVT(Matt Finish)/PGVT(Glossy Finish) must be decide by Engr in charge2.Glazed Coating on GVT/PGVT must not be less than 1mm. |
| 38 | M&L for scratch & Jointfree Glazed(Porcelain) Vitrified Tiles(GVT)/Polished Glazed Vitrified Tiles(PGVT) 9mm-10mm thick (square or rectangular) area of each tile exceeding 0.18sqmbut not exceeding 0.36 sqm ie size 600x600mm in skirting/ vertical portion etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat on brick work in CM 1:4 asin skirting complete all as specified and as directed.Note : 1.Size and pattern/texture of GVT(Matt Finish)/PGVT(Glossy Finish) must be decide by Engr in charge2.Glazed Coating on GVT/PGVT must not be less than 1mm. |
| 39 | M&L for scratch & Jointfree Glazed(Porcelain) Vitrified Tiles(GVT)/Polished Glazed Vitrified Tiles(PGVT) 9mm-10mm thick (square or rectangular) area of each tile exceeding 0.36sqmbut not exceeding 0.72 sqm ie size 600x1200mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified and as directed.Note : 1.Size and pattern/texture of GVT(Matt Finish)/PGVT(Glossy Finish) must be decide by Engr in charge2.Glazed Coating on GVT/PGVT must not be less than 1mm. |
| 40 | M&L for scratch & Jointfree Glazed(Porcelain) Vitrified Tiles(GVT)/Polished Glazed Vitrified Tiles(PGVT) 9mm-10mm thick (square or rectangular) area of each tile exceeding 0.36sqmbut not exceeding 0.72 sqm ie size 600x1200mm as in skirting/ vertical portion etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat on brick work in CM 1:4as in skirting complete all as specified and as directed.Note : 1.Size and pattern/texture of GVT(Matt Finish)/PGVT(Glossy Finish) must be decide by Engr in charge2.Glazed Coating on GVT/PGVT must not be less than 1mm. |
| 41 | Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified and as directed. |
| 42 | M&Lfor 20 mm thickGranite slab work(table rubbed and polish) of approved quality ofrequired sizein Floor,Wall, Platform ,steps/riser and like beddedand jointed in greycement slurry and pointed with coloured cement(1:2) usig marble dustwith admixture of pigment to match the shade of granite stonelaid over and including 20 mm thick screed bed in CM (1:6) complete allas specified anddirected. |
| 43 | M&L for60mm thick factory made chamfered edge cement concrete paver block of M-35 gradeas in footparth orlight traffic parking etc, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sandall as specified and as directed. Note: Shape/size,colour design/pattern of interlocking paver block is selected by Engr-in - charge. |
| 44 | M&Lfor chequered cement concrete tiles with grey cementand pigment of size 30cmX30cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 20 mm thick screed bed in CM 1:6complete all as specified and directed. |
| 45 | M & Lfor machine cut kota stone slab inflooring of floor/steps 18-20 mm thick laid over and including 20mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing & and polishing complete all as specified and as directed. |
| 46 | M&L grinding & wax polishing to mirror finish to old kota stone slab flooring & steps, mixed with pigment to match the shade of slab complete all as specified and directed. |
| 47 | Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land all asspecified and as directed . |
| 48 | M& L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate, including finishing surface of concrete topping even and rough complete all as specified. |
| 49 | M&L for 75mm thickPCC1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor etccomplete all as specified and directed |
| 50 | M & L for 75mm thick cement concrete 1:3:6 type C1, with using 20mm graded stone aggregateas in floor/ plinth protection finish the surface even and smooth shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter inlength, joint of 6 mm wide and 10 mm deep shall be povided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all as specified and as directed. |
| 51 | Taking down cement plaster of any description including raking outjoints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM. complete all as specified and directed. |
| 52 | Material & labour for Rendering 10 mm thick CM 1:6on brick or concrete surfaces finished even & smooth without using extra cement complete all asspecified and directed. |
| 53 | M & L for Rendering 15 mm thick in two layer (top layer 5mm thick in CM 1:4 mixed with WPC over 10mm thick in CM 1:6) WPC mixed as permanufacturer\"s instructions on brick or concrete surfaces and finishing surfaceseven & fair without using extra cement complete all asspecified and directed. |
| 54 | M&L preparation of newly plastered surface of External wallto remove the dent with wall care putty and to make the surface even and smooth by grinding or rubbing with sand paper and applying Two or more coats of 100% Premium acrylic emulsion paintover priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.Note- Putty shall be measured and paid seperately. |
| 55 | M&L for preparation of newly plastered surface of internal wall by application of 1mm thick wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. |
| 56 | M&L preparation of oldsurface of External wallto remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying Two or more coats of 100% Premium acrylic emulsion paint over apriming coat of exterior primer applied @ 0.90 litre/ 10 sqm, over one coat ofputty complete all as directed.Note- Putty shall be measured and paid seperately. |
| 57 | Material & Labour for preparation of old surface of internal walland applying two coats of oil emulsion distemperoverputty (if required) make the surface even and smooth of all as specified and prescribed by manufacturer of paint and all as directed.Note- Putty shall be measured and paid seperately. |
| 58 | M&L for 1mm thickAcrylic/Water Proof Wall Putty & surface finished even and smooth with sand paper completeall as specified and directed |
| 59 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins etc. under 40 sq. cm in section in un-framed work complete all as specified and directed. |
| 60 | Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, includingNainital or similar pattern roof coverings complete all as specified and as directed. |
| 61 | S&F 0.50mm thick (including coated thickness) pre-colourpre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa asin roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self tapping screws including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 62 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ ridge, valey gutter fixed with self tapping screws with min 150mm end lap or as per manufacturer instructioncomplete all as specified and directed. |
| 63 | M&L infor MS steelHollow ,Joist, channel, angle,tee or tubular Sectionwork in tubular trusses, purlins, rafter, tubuler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4923-2017 andIS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 64 | S&F mild steel framed work as in grills, gratings etc with ends of bars shouldered and riveted or forged into spikes, framed guard bars, barred iron doors etc, conforming to Fe-290, Gde-E-165 all as specified and directed |
| 65 | Preparation of newlysteel surfaces, of any description, over 10 cm width or girth, and applying Two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed |
| 66 | M&L for second class hard wood as in scantling, fixed in framed work clean sawnincluding dismantling of timber scantling 40 sqcm and above in section in any position, framed work complete all as specified and directed |
| 67 | S&F for 20 mm thick 2nd class hard wood boarding planed one side with butt joints and fixed with nails as in roofs, ceiling partition fascia, barge soffit etc (except flooring and skirting) including dismantling boarding, any description, fixed in any position with nailscomplete all as specified and directed |
| 68 | Preparation of new wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 69 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes (6 Kg / Sqcm pressure rating) (single socketed in any length with rubber ringjointsfixed to walls including demolition of existingpipe complete all as specified and directed. |
| 70 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes , single socketed in any length with rubber ring joints r fixed to wall including demolition of existing PVC pipe complete all as specified and directed. |
| 71 | S&F 75mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed |
| 72 | S&F PVC (SWR) junction single, (Single T) equal or unequal 75 mm bore with access door complete all as specified and directed |
| 73 | S&F PVC (SWR) junction single, (Single T) equal or unequal 110 mm bore with access door complete all as specified and directed |
| 74 | S&FPVC (SWR) bend any radius 110 mm borecomplete all as specified and directed |
| 75 | S&FPVC (SWR) bend any radius 75 mm borecomplete all as specified and directed |
| 76 | S&FPVC vent cowls 110 mm complete all as specified and directed |
| 77 | S&F 500 ltr capacity \"ISI\" marked rotational moulded polyethylenewater storage tanks triplelayered white (cylindrical vertical with closed top) hoisted and fixed in position and including 20 mm dia ball float valves high pressure of PTMT with epoxy coated aluminium rod and high density plasttic ball screwed for iron pipe and fixed (Minimum weight 20mm dia -455gms) including dismantling of water tanks complete all as specified and directed |
| 78 | S&F 1000 ltr capacity \"ISI\" marked rotational moulded polyethylenewater storage tanks triplelayered white (cylindrical vertical with closed top) hoisted and fixed in position and including 20 mm dia ball float valves high pressure of PTMT with epoxy coated aluminium rod and high density plasttic ball screwed for iron pipe and fixed (Minimum weight 20mm dia - 455gms) including dismantling of water tanks complete all as specified and directed |
| 79 | S&F in repairvitreous china squatting pan \"orissa pattern 580 mmX 440 mm white with integral foot rests (excluding flushing cistern and flushing pipe but incl fixing with 110mm \"P\" or \"S\" trap complete all as specified and directed |
| 80 | S&F in repair white /colour vitreous china wash down water closet pedestalpattern \"P\" or \"S\" trap type excluding flushing cistern and flush pipes complete all as specified and directed |
| 81 | S&F Vitreous china wash hand basin with pedestal in repair ,white ,flat back of size 550x400mm including cutting for pinning in ends, pair of cast iron brackets and provision of PVC solid typewaste pipe 32mm of adequate length , waste coupling32mm dia of bress chromium plated half or full threaded, complete all as specified and as directed. |
| 82 | S & F in repair vitreous china wash basin white (table top) of size490x400x145 mm including 32mm brass CP waste coupling complete all as specified and as directed . |
| 83 | S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), lowlevel , white, with inlet ball valve, float and handle including brackets and 32 mm flush pipe suitable for IWC/EWC of polyethylene of low or high density |
| 84 | S&F in repair PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed in repairs complete all as specified. |
| 85 | S&F 15 mm bore Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including taking down steel tubing all as specified. |
| 86 | S&F 20mm bore Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs,unions etc.) including taking down steel tubing all as specified. |
| 87 | S&F in repair 15mm Bib tap fancy type cast copper chromium plated alloy with capstan handle quarter turn screwed down screwed for iron pipe or for brass ferrule and fixed. |
| 88 | S&F in repair fancy type chromium plated 15mm boretwo way Bib cock cast copper alloy with crutch or capstan handle, quarter turn screwed for iron pipe or brass ferrule etc complete all as specified and as directed. |
| 89 | S&Fin repair Stop Angle valve cast copper alloy chromium plated15mm dia, screwed down, high pressure with capstan handle, quarter turn screwed both ends for iron pipes or for unions and fixed ,complete all as specified. |
| 90 | S&F in repair CP brass health faucet with 1m flexible tube and wall hook complete all as specified and directed. |
| 91 | S&F in repair CP overhead shower 100mm round/Square shape single flow (ABS body chromium plated with gray face plate) with rubit cleaning systemfixed in 15mm bore of pipe complete all as specified and directed . |
| 92 | S&F 15mm dia brass CP wall mixer with provisionfor over head showerfor mixing hot and cold water screwed down for iron pipe and fixed including taking down existing bib tap complete all as specified and directed. |
| 93 | S&F 15mm dia chromium plated central hole wash hand basin mixer without PWS with 450mm BRAIDED HOUSE hosescrewed down high pressure screwed for iron pipe including taking down existing piller tap completed all as specified and directed . |
| 94 | S&F in repair 6mm thick Frameless beveled edge mirror of selected quality glassfixed with CP screw and CP washer and other required fixing arrangement complete all as specified and directed.Note- 1.Size/Shape of Mirror will be decided by Engr in Charge. |
| 95 | S&F in repair kitchensink with drainage board made of stainless steel 1.0 mm thick in kitchen with plug , washer and waste including or including fixing cantilever cast iron bracket and connecting union to pipes over all size 915x460 mm bowl size 410x330x160 mm including taking out unserviceable kitchen sinkcomplete all as specified and as directed. |
| 96 | S&F as in repair stainless steel kitchen plate rack of size (900x600x250mm) inch of minimum thickness 0.8mmincluding necessary drilling, fixing with screw, plugs in kitchen etc complete all as specified and directed |
| 97 | S&F in repair CP Brass Tubular towel rail 20mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and directed. |
| 98 | S&F in repair corner glass shelf 5 mm thick, 200mm size min,(with bracket) all as specified and directed. |
| 99 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg)as in roof padding to receive roof treatment including demolition of cement concrete (unreinforced) in roof/terraceincluding existing roof treatment of any description complete all as specified and directed. |
| 100 | M&L for rendering 10 mm thick in cement mortar 1:3on roof surface including mixed with WPC as per manufacturer\"s instruction\"s and finishing the surfaces even and smooth without using extra cementcomplete all as specified and directed.Note :- WPC shall be measured and paid for separately as supply only under respective item of sch \"A\". |
| 101 | Supply Only Liquiid WPC |
| 102 | M&L laying water proofing treatment to non-accessibleroof slabwith APP based modified polymeric membrane as per manufacturer’s instructions including with following course of description below :- (a)Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.(b) Providing APP based 3 layer polymeric membrane minimum weighing 3 .0Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer\"s instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membranceNote : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessibleroof slab for double storeyed.The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.) |
| 103 | M & L for red stone slab 18 mm to 20 mm thick dressed true and square in one lengthnot less than 60 cm and n. exc 120 cm in plinth protection / hardstanding over and including 20 mm thick screed bed in cm 1:4complete all as specified and directed. |
| 104 | S& F Eye Hole for Main Door - 200 Degree Wide Magic Eye viewer for Safety Constructed from durable solid brass material, of size 4.5 X 3.5 X 3.5 cm complete all as specified and directed. |
| 105 | S& F stainless steel finger pull type oval shape of min size 16.1x5.5x4.7 cm, min wt 140 gm key lock door safety chain, door security guard for complete all as specified and directed. |
| 106 | Earth work in excavation in trenches not exc 1.5 m wide and not exc 1.5m depth for foundation etc or for shafts, wells, manholes, pier holes etc. not exc 10 Sqm on plan and not exc 1.5m depth and getting out in soft/ disintergrated soil complete all as specified and directed. |
| 107 | Demolition and breaking updrain pipe (SGSW )of 150 mm nominal bore laid in trenches, set & jointed in cement morter, incl necessary earth work, all as specified and directed. |
| 108 | M & L Cement concrete 1:3:6 type C-2 Concrete bed to 150mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 109 | M&L 150 mm Salt-glazed stone ware drain pipes laid in trenches and jointed as specified and directed. |
| 110 | Demolition of reinforced cement concrete in ground floor not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land all asspecified and as directed . |
| 111 | M&L for RCC type B-1, 1:2:4 (20 mm graded BT stone aggregate) in precast as in small coverslab,manholes and soak well cover slab etc set in cement mortar (1:4) etc with and incl necessary form works as directed and fixed complete all asspecified and directe.(Note:-Reinforcement shall be measured & paid separately). |
| 112 | M & L RCC ( nominal mix ) type B1, 1:2:4 (20 mm graded agg) as in beams/slab, cantilevers, bressumers, lintels over 1.5 m span complete all as specified. |
| 113 | M&L use and waste of form worktoside and soffits of floor or roof beams, litels flat rough finished complete all as specified. |
| 114 | M&L for TMT bar 10 mm andover cut to length, bend to shape required including cranking, bending spirally for hoopings for cols, hooking ends and binding with ad including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified. |
| 115 | M&L for TMT bar 5mm dia and over upto and including 10mm dia cut to length, bend to shape required including cranking, bending spirally for hoopings for cols, hooking ends and binding with ad including mild steel wire (annealed) not less than 0.9 mm dia. in stirrups, spacers and binders complete all as specified. |
| 116 | M&L cement concrete1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and directed. |
| 117 | M&L for PCC 1:2:4 type B1 (Using 20mm graded agg) as in coping etc including necesarry form works complete all as specified and as directed. |
| 118 | Dismantling post or strut embeded in concrete( wood/steel/RCC) any section embeded in concrete including taking out embeded portion and making good all as directed & specified |
| 119 | Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out inHard/Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed by Engr in Charge. |
| 120 | M & L for PCC 1:2:4 type B2 using 40 mm graded aggregate as in foundation ,post, etc complete all as specified and directed by Engr in Charge. |
| 121 | Dismantling of Fencing wire mesh ay any type complete all as specified and directed by Engr in Charge. |
| 122 | Fixing only chain link fencing including line wires, including provision of binding wire. complete all as specified and directed by Engr in Charge. |
| 123 | Supply only Chain link MS galvanisd fencing complete all as specified and directed by Engr in Charge. |
| 124 | S&F Galvanised 2 strand steel barbed wire(Type A1,IS278) 2.5mm dia barbed with 2.5mm dia barbs at 75mm spacings and straining and fixing to angle iron portion with 6mm dia nibs including, securing or tying at crossings complete all as specified and directed by Engr in Charge. |
| 125 | S & Fof11 to 15mm dia of neck MS Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n ex 5cm long etc complete all as specified anddirected. |
| 126 | S&F posts and struts in fencing including cutting tops to shape as directed , drilling holes , notching for wire , etc , flat iron fillets ( for securing wire mesh etc ) including all necessary drilling , bolting riveting etc and similar work confirmingto Fe-290 Gde E-165 Complete all as specified and directed. |
| 127 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 128 | S & F MS framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to Fe-290 Gde E-165complete all as specified and as directed. |
| 129 | Preparation of newlysteel surfaces, of any description, n ex 10 cm width or girth, and applying Two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed |
| 130 | S&FMS roundbar fixed to chain link fening including weilding of bar with fencing wire complete all as specified and directed. |
| 131 | Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed. |
| 132 | Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed rigid PVC conduit(ISI marked) ,duly cutting chases & concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia(Color coding of wires shall be Phase, neutral and earth wire all as specified ) including metal flush box made of GI sheet and white cover with making good the disturbs surfaces of wall/floor/ceiling complete all as specified and directed for the following.Note: Flush box and cover plate should be of same make all as approved for switches/sockets. |
| 133 | One light/fan/bell point controlled by one No modular type switch 6 Amps single pole one way |
| 134 | One 3 pin 6 Amps socket outlet on same board controlled by one, one way 6 Amps modular switch. |
| 135 | One socket outlet 5/3 pin 6 Amps controlled by one modular switch on independent board. |
| 136 | All as per item No 4 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor1100 V grade PVC insulated FRLSH but unsheathed single core for16 Amps power point on independent board and 2.5 sqmm FRLSH cable as earthwire. |
| 137 | S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzcomplete all as specified and directed. |
| 138 | Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 Hz complete all as specified and directed. |
| 139 | Supply and fixModular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. |
| 140 | Supply and fixModular Socket outlet, 16A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. |
| 141 | S&F Modular Bell push 6A, 2 module, 240 volts ISI marked complete all as specified and directed. |
| 142 | Supply and fixModular white cover Plate with frame for housing of Modular Swiches/ Sockets of 6/16 Amps, 3 module ISI marked complete all as specified and directed. |
| 143 | Supply and fixModular white cover Plate with frame for housing of Modular Swiches/ Sockets of 6/16 Amps, 6 module ISI marked complete all as specified and directed. |
| 144 | Supply and fixing bell ding dong AC volts single pole, complete all as specified & directed. |
| 145 | S&F in repair Lamp holder insulated body with back plate, suitable for Batten fittings complete all as specified & directed. |
| 146 | S & F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for \"B-22 type to fix on batten holder complete all as specified and directed. |
| 147 | S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as speccified and directed |
| 148 | S&F MCB DB SPN 8 way, 240 volts in sheet steel enclosure.double door type including taking down old DB complete all as specified and directed. |
| 149 | S&F MCB DB SPN 6 way 240 volts in sheet steel enclosure.double door type including taking down old DB complete all as specified and directed. |
| 150 | S&F MCB DB TPN 4 way 415 V rated copper busbar in sheet steel enclosure,double door type,complete all as specified and as directed. |
| 151 | S&F MCB , SP, AC, 240 volts of 06 to 32Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 152 | S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 153 | S&F MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 154 | S& F in replacement LED tube light fittings 10 watts, 230 volts, 2 feet long complete with all accessories internally pre-wired and including connecting up with twisted flexible cable of 0.75 Sqmm copper coductor form ceiling rose to light fittings complete allas directed and specified. |
| 155 | S& F in replacement LED tube light fittings 20 watts, 230 volts, 4 feet long complete with all accessories internally pre-wired and including connecting up with twisted flexible cable of 0.75 Sqmm copper coductor form ceiling rose to light fittings complete allas directed and specified. |
| 156 | S&F 36 Watt,LED Panel 2X2 Feet environmentalfriendly, fully diffused, using engineering grade aluminum diffuser, new generation, aesthetically designed, CRCAhousing, ultramodern recess mounting luminaire with high brightness SMD LEDsas light source, suitablefor Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.90, thd<15%, CCT 6500K,with separate electronic driver ceiling light 36W including connectingup with twin core twisted flexible copperconductorcable with suitable size of 230V, 50HZ allas specified & directed. |
| 157 | Supply and fixLEDWall Bracket light fitting (Bldg Security light) 30W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape and appropriate length including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete all as specified and directed. |
| 158 | S&F sub main wiringtwo single core6 Sqmm PVC insulated, unsheathed, stranded copper conductor cable(FRLSH) 1100Volts grade drawn in & including rigid PVC Conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sqmm PVC insualted unsheathed copper conductor cable (FRLSH) as earth wire andwire connected with main earth dolly including removing old submain, cutting chases and making good disturbed portion complete all as specified and directed. Note : Two runs of phase, neutral wire and one run of earth wire and PVC conduit will be measured as one RM or one length. |
| 159 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4mm GI Wirecheck nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 160 | S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter,AC single phase 230/240 Volt ,50HZ,RPM 1200,Copper winding of250 mm sweep with blades, frame and louvers complete including making holeand making good the disturbed sufaces of wall all complete all as specified and directed. Note:- Old Exhaust fan deposit at MES Store Yard. |
| 161 | S&F Exhaust fan made of steel body ,AC single phase 230/240 Volt ,50HZ, Copper winding of size 300 mm sweep with blades, frame and louvers complete all as specified and directed. Note:- Old Exhaust fan deposit at MES Store Yard. |
| 162 | S&F Exhaust fan made of steel body ,AC single phase 230/240 Volt ,50HZ, Copper winding of size 450 mm sweep with blades, frame and louvers complete all as specified and directed. Note:- Old Exhaust fan deposit at MES Store Yard. |
| 163 | Supply and installation of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass coating inside the tank alongwith heating element with anticorrosive magnesium anode, NRV, thermostat, indicator and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with G.I. hexagonal adapters/ nuts on both side for inlet (cold water supply) & outlet (hot water supply) and including provision ofwall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed. Make :- Havells, Bajaj, JaquarNote:- Old Geyser deposit at MES Store Yard. |
| 164 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 4mm dia galvanised iron or steel wire. |
| 165 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed having canopy, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 240 Amps for each phase and 120 Amps for neutral including interconnection of all switch gears, fixed on DMC insulators and provision of extension. |
| 166 | (Incoming) (a)MCCB 160 Amp, 415 Volts, 04 Pole 50Hz, 25 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 200 Amps digital type with built in selector switch, CTs ofratio 200/5A , 5va class 1.0 = 01 set. c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d)Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 167 | (Outgoing) Consist of separate compartment for each MCCB.-(a)MCCB 80 Amp, 415 Volts, 04 Pole 50Hz, 16 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos.(b) MCB TPN 63 Amp, 415 Volts, 04 Pole 50Hz, 10 KA- 03 Nos |
| 168 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power UG cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of folowign sizescomplete as specified and directed. |
| 169 | 10 Sqmm 4 core |
| 170 | 16 Sqmm 4 core |
| 171 | 25 Sqmm 3.5 Core |
| 172 | 35 Sqmm 3.5 core |
| 173 | Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding1.5m in depth forlaying UG cable/foundation etc complete all as specified and directed. |
| 174 | Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed. |
| 175 | Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtrand depositing where directedat a level not exc 1.5 mtrabove the starting point complete all as specified and directed. |
| 176 | M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid sepetarely under relevent item of Sch A. |
| 177 | M&L for cable protection bricks common burnt clay sub class B designation 75 for protection of UG Cable laid in trenches complete all as specified and directed. |
| 178 | Supply, fixing, laying, jointing & testing of galvanised iron water tubing \"light grade\" conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed for the 50 mm bore pipes. |
| 179 | Taking up/down of old U/S Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 16 Sqmm size all as specified and directed. |
| 180 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25x4mm GI Stripcheck nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail